Articles | Volume 22, issue 1
https://doi.org/10.5194/hess-22-819-2018
© Author(s) 2018. This work is distributed under
the Creative Commons Attribution 4.0 License.Technical note: Using distributed temperature sensing for Bowen ratio evaporation measurements
Download
- Final revised paper (published on 30 Jan 2018)
- Preprint (discussion started on 04 Aug 2017)
Interactive discussion
AC: Author comment | RC: Referee comment | SC: Short comment | EC: Editor comment
- Printer-friendly version
- Supplement
-
RC1: 'comment', Anonymous Referee #1, 20 Aug 2017
-
AC1: 'Reply to referee #1', Bart Schilperoort, 27 Sep 2017
-
RC3: 'comment 2', Anonymous Referee #1, 29 Sep 2017
- SC1: 'Reply to comment 2', Bart Schilperoort, 29 Sep 2017
-
RC3: 'comment 2', Anonymous Referee #1, 29 Sep 2017
-
AC1: 'Reply to referee #1', Bart Schilperoort, 27 Sep 2017
-
RC2: 'Using Distributed Temperature Sensing for Bowen ratio evaporation measurements” by Bart Schilperoort et al.', Anonymous Referee #2, 20 Aug 2017
- AC2: 'Reply to referee #2', Bart Schilperoort, 27 Sep 2017
Peer-review completion
AR: Author's response | RR: Referee report | ED: Editor decision
ED: Publish subject to revisions (further review by editor and referees) (21 Oct 2017) by Pierre Gentine
AR by Bart Schilperoort on behalf of the Authors (27 Nov 2017)
Author's response
Manuscript
ED: Publish as is (20 Dec 2017) by Pierre Gentine
AR by Bart Schilperoort on behalf of the Authors (27 Dec 2017)