<?xml version="1.0" encoding="UTF-8"?>
<!DOCTYPE article PUBLIC "-//NLM//DTD Journal Publishing with OASIS Tables v3.0 20080202//EN" "journalpub-oasis3.dtd">
<article xmlns:xlink="http://www.w3.org/1999/xlink" xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:oasis="http://docs.oasis-open.org/ns/oasis-exchange/table" xml:lang="en" dtd-version="3.0"><?xmltex \makeatother\@nolinetrue\makeatletter?><?xmltex \hack{\allowdisplaybreaks}?>
  <front>
    <journal-meta><journal-id journal-id-type="publisher">HESS</journal-id><journal-title-group>
    <journal-title>Hydrology and Earth System Sciences</journal-title>
    <abbrev-journal-title abbrev-type="publisher">HESS</abbrev-journal-title><abbrev-journal-title abbrev-type="nlm-ta">Hydrol. Earth Syst. Sci.</abbrev-journal-title>
  </journal-title-group><issn pub-type="epub">1607-7938</issn><publisher>
    <publisher-name>Copernicus Publications</publisher-name>
    <publisher-loc>Göttingen, Germany</publisher-loc>
  </publisher></journal-meta>
    <article-meta>
      <article-id pub-id-type="doi">10.5194/hess-22-5615-2018</article-id><title-group><article-title>A small-volume multiplexed pumping system for automated,<?xmltex \hack{\break}?> high-frequency water
chemistry measurements in<?xmltex \hack{\break}?> volume-limited applications</article-title><alt-title>Multiplexed pumping system for volume-limited applications</alt-title>
      </title-group><?xmltex \runningtitle{Multiplexed pumping system for volume-limited applications}?><?xmltex \runningauthor{B. M. Maxwell et al.}?>
      <contrib-group>
        <contrib contrib-type="author" corresp="yes" rid="aff1">
          <name><surname>Maxwell</surname><given-names>Bryan M.</given-names></name>
          <email>bmmaxwel@ncsu.edu</email>
        </contrib>
        <contrib contrib-type="author" corresp="no" rid="aff1">
          <name><surname>Birgand</surname><given-names>François</given-names></name>
          
        </contrib>
        <contrib contrib-type="author" corresp="no" rid="aff2">
          <name><surname>Smith</surname><given-names>Brad</given-names></name>
          
        </contrib>
        <contrib contrib-type="author" corresp="no" rid="aff1">
          <name><surname>Aveni-Deforge</surname><given-names>Kyle</given-names></name>
          
        </contrib>
        <aff id="aff1"><label>1</label><institution>Biological and Agricultural Engineering, North Carolina State University, 3110 Faucette Drive, Raleigh, 27695, USA</institution>
        </aff>
        <aff id="aff2"><label>2</label><institution>Sungate Design Group, 905 Jones Franklin Road, Raleigh, 27606, USA</institution>
        </aff>
      </contrib-group>
      <author-notes><corresp id="corr1">Bryan M. Maxwell (bmmaxwel@ncsu.edu)</corresp></author-notes><pub-date><day>30</day><month>October</month><year>2018</year></pub-date>
      
      <volume>22</volume>
      <issue>11</issue>
      <fpage>5615</fpage><lpage>5628</lpage>
      <history>
        <date date-type="received"><day>23</day><month>April</month><year>2018</year></date>
           <date date-type="rev-request"><day>31</day><month>May</month><year>2018</year></date>
           <date date-type="rev-recd"><day>26</day><month>September</month><year>2018</year></date>
           <date date-type="accepted"><day>9</day><month>October</month><year>2018</year></date>
      </history>
      <permissions>
        
        
      <license license-type="open-access"><license-p>This work is licensed under the Creative Commons Attribution 4.0 International License. To view a copy of this licence, visit <ext-link ext-link-type="uri" xlink:href="https://creativecommons.org/licenses/by/4.0/">https://creativecommons.org/licenses/by/4.0/</ext-link></license-p></license></permissions><self-uri xlink:href="https://hess.copernicus.org/articles/22/5615/2018/hess-22-5615-2018.html">This article is available from https://hess.copernicus.org/articles/22/5615/2018/hess-22-5615-2018.html</self-uri><self-uri xlink:href="https://hess.copernicus.org/articles/22/5615/2018/hess-22-5615-2018.pdf">The full text article is available as a PDF file from https://hess.copernicus.org/articles/22/5615/2018/hess-22-5615-2018.pdf</self-uri>
      <abstract>
    <p id="d1e118">An automated multiplexed pumping system (MPS) for high-frequency water
chemistry measurements at multiple locations previously showed the ability to
increase spatial and temporal data resolution and improve understanding of
biogeochemical processes in aquatic environments and at the land–water
interface. The design of the previous system precludes its use in
volume-limited applications in which highly frequent measurements requiring
a large sample volume would significantly affect observed processes. A small-volume MPS was designed to minimize the sample volume while still providing high-frequency data. The system was tested for cross-contamination between
multiple sources, and two applications of the technology are reported. Cross-contamination from multiple sources was shown to be negligible when using
recommended procedures. Short-circuiting of flow in a bioreactor was directly
observed using high-frequency porewater sampling in a well network, and the
small-volume MPS showed high seasonal and spatial variability of nitrate
removal in stream sediments, enhancing data collected from in situ mesocosms.
The results show it is possible to obtain high-frequency data in
volume-limited applications. The technology is most promising at the reach or
transect scale for observing porewater solute dynamics over daily timescales, with data intervals <inline-formula><mml:math id="M1" display="inline"><mml:mrow><mml:mo>&lt;</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:math></inline-formula> h for up to 12 locations.</p>
  </abstract>
    </article-meta>
  </front>
<body>
      

      <?xmltex \hack{\newpage}?>
<sec id="Ch1.S1" sec-type="intro">
  <title>Advancements in high-frequency water quality monitoring</title>
      <p id="d1e140">Recent
UV–VIS field spectrometers provide an opportunity for high-frequency in situ
monitoring to increase the temporal resolution of water quality data. Water
quality has been measured with these instruments by correlating absorbance
with chemical concentration (Crumpton et al., 1992; Suzuki and Kuroda, 1987;
Finch et al., 1998; Johnson and Coletti, 2002; Rochelle-Newall and Fisher,
2002; Saraceno et al., 2009). Rieger et al. (2006) and Torres and
Bertrand-Krajewski (2008) measured total suspended solids (TSS) in
wastewaters using partial least-squares regression (PLSR) to correlate
absorbance fingerprints to concentrations. Etheridge et al. (2014) expanded
the technique to measure light- and non-absorbing constituents including
<inline-formula><mml:math id="M2" display="inline"><mml:mrow class="chem"><mml:msubsup><mml:mi mathvariant="normal">PO</mml:mi><mml:mn mathvariant="normal">4</mml:mn><mml:mrow><mml:mn mathvariant="normal">3</mml:mn><mml:mo>-</mml:mo></mml:mrow></mml:msubsup></mml:mrow></mml:math></inline-formula>, total phosphorus, nitrate (<inline-formula><mml:math id="M3" display="inline"><mml:mrow class="chem"><mml:msubsup><mml:mi mathvariant="normal">NO</mml:mi><mml:mn mathvariant="normal">3</mml:mn><mml:mo>-</mml:mo></mml:msubsup></mml:mrow></mml:math></inline-formula>), total
Kjeldahl nitrogen, TSS, dissolved organic carbon, and salinity in
a brackish North Carolina marsh. Birgand et al. (2016) have shown that the
technique might also be used to measure iron and silica in lakes and
reservoirs.</p>
      <p id="d1e172">Among the spatial heterogeneity of biological and chemical processes in the
environment (Merill and Tonjes, 2014; Kahlert et al., 2002; Dent and Grimm,
1999; Parkin, 1987), patches referred to as “hotspots” are particularly
interesting (e.g., riparian buffers, hyporheic zones). These hotspots
have been observed to have a disproportionate impact on biogeochemical
cycles, and can be particularly active over short periods of time referred to
as “hot moments” (McClain et al., 2003; Vidon et al., 2010). While temporal
resolution has and will provide invaluable information at a<?pagebreak page5616?> particular
monitoring station (e.g., Etheridge et al., 2014), expanding resolution to
spatial data could illuminate tightly coupled processes and would greatly
magnify the value of these instruments. Documenting the short-term fate of
reactive nutrients within identified hotspots might provide new insight
into nutrient cycles and their controlling factors.</p>
      <p id="d1e175">An automated large volume multiplexed pumping system (MPS) capable of pumping
water from up to 12 sources to a UV–VIS spectrophotometer was previously
reported (Birgand et al., 2016). The MPS is a “multiplexed” system in that
it delivers sample volumes from separate sources to a single probe used to
consecutively observe water chemistry at all sources. The 3.18 mm inside
diameter (i.d.) tubing yields an average volume of 100 mL of water per sample,
which is very well adapted when the source can easily accommodate such
withdrawal without consequences for the source or the processes studied.
Certain applications, however, may require minimizing sample withdrawal to
avoid disturbing the observed process while still obtaining high-frequency
data. Observing solute dynamics in soils or sediments, particularly those
with low drainable porosity, is one such example of a volume-limited
application.</p>
      <p id="d1e178">In this article, we are reporting the capabilities offered by a small-volume
MPS coupled with a field spectrophotometer to obtain high-resolution water
quality data in both time and space. This system can accommodate small
volumes (<inline-formula><mml:math id="M4" display="inline"><mml:mrow><mml:mo>&lt;</mml:mo><mml:mn mathvariant="normal">15</mml:mn></mml:mrow></mml:math></inline-formula> mL) from up to 12 different sources located within a
10 m distance of the instrument and provide absorbance measurements at
better than hourly intervals at each location. This system was designed to
minimize inline volumes for volume-limited applications. This article
describes the instrument and the challenges involved, evaluates its
performance, and reports two applications of this system in such
volume-limited conditions.</p>
</sec>
<sec id="Ch1.S2">
  <title>Small-volume multiplexed pumping system</title>
      <p id="d1e197">The principle followed for this instrument is to use a portable
spectrophotometer as a central portable laboratory, coupled with the MPS able
to sequentially pump water from several points within a reasonable distance
of the probe. The small-volume MPS is designed for high-frequency sampling in
volume-limited applications. The solution to minimizing sample volume is
small-diameter tubing and a low-volume flow-through measurement cell. The
challenges of this design include clogging of tubing and high head losses due
to surface tension forces in the tubing. The latter implies higher pump
suction and tends to generate sample residuals left after purging along the
length of the tubing, increasing the potential for cross-contamination
between samples. This drawback demands specific evaluation of the
small-volume MPS before use.</p><?xmltex \hack{\newpage}?>
<sec id="Ch1.S2.SS1">
  <title>System design and hardware</title>
      <p id="d1e206">The major components of the system include (1) a UV–VIS spectrophotometer
fitted with a flow-through cuvette, (2) a bidirectional peristaltic pump,
(3) small-diameter polytetrafluoroethylene (PTFE or Teflon) tubing, (4) an
Arduino control board (Arduino), (5) a 12-port valve, (6) a three-way valve
manifold, and (7) an optional fractional volume collector.</p>
      <p id="d1e209">The general automated “sampling sequence” for the system starts with
pumping from source <inline-formula><mml:math id="M5" display="inline"><mml:mi>n</mml:mi></mml:math></inline-formula> to a flow-through spectrophotometer cuvette via
0.9 mm i.d. PFTE
tubing and a peristaltic pump. After the water has entered the cuvette the
spectrophotometer takes a measurement and water is then purged back either to
the source, to a fractional volume collector, or to waste using a three-way valve
manifold. The multi-port valve then selects source <inline-formula><mml:math id="M6" display="inline"><mml:mrow><mml:mi>n</mml:mi><mml:mo>+</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:math></inline-formula>, and a similar
sampling sequence takes place. Up to 12 sampling sequences
corresponding to the 12 ports of the multi-port valve can occur during a
“sampling cycle”. A fractional volume collector can be used to collect
selected sample volumes so that readings by the spectrophotometer can be
compared to lab-measured concentrations.</p>

      <?xmltex \floatpos{t}?><fig id="Ch1.F1" specific-use="star"><caption><p id="d1e233">Graphical depiction of small-volume multiplexed pumping system (MPS)
configurations which include (1) DI water source, (2) 12-port intake valve,
(3, 4) waste or air purge, (5) fractional volume collector (FVC),
(6) bidirectional peristaltic pump, and (7) spectrophotometer with cuvette
housing. An Arduino microcontroller actuates a series of three-way valves to move
between separate configurations <bold>(a–f)</bold> described in
Sects. 2.2.1–2.2.5.</p></caption>
          <?xmltex \igopts{width=426.791339pt}?><graphic xlink:href="https://hess.copernicus.org/articles/22/5615/2018/hess-22-5615-2018-f01.png"/>

        </fig>

      <p id="d1e245">Control of the MPS pumping, purging, valve actuation, and activity logging is
performed by an Arduino Mega 53 pin control chip (Arduino,
<uri>www.arduino.cc</uri>). This inexpensive control board utilizes open-source
software for easy-to-use programming and hardware interfacing, although other
similar board/microprocessors can be used. The high-frequency water quality
probe used is a UV–VIS field spectrophotometer
Spectro::Lyser<sup>™</sup> by
s::can<sup>™</sup> fitted with a 4 mm path length,
1.1 mL flow-through quartz cuvette (Starna Cells, Inc. model 46-Q-4) placed
vertically to facilitate cuvette drainage by gravity during purging. The
water quality probe is used as a “master” instrument to dictate to the MPS
“slave” system when to begin a sampling sequence. We use an existing
capability of the spectrophotometer to send a 12 V signal at an adjustable
time prior to a measurement as a trigger for the MPS, although any other
triggering method (e.g., time-based using the Arduino control board) could be
used.</p>
      <p id="d1e258">A peristaltic pump provides pumping and purging at 20 mL min<inline-formula><mml:math id="M7" display="inline"><mml:msup><mml:mi/><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:msup></mml:math></inline-formula> flow
rate acceptable for the 0.9 mm I.D. tubing used. A MOSFET H bridge
controlled by the Arduino reverses DC polarity at the pump to alternate
between pumping and purging. The 12-port valve used is a low-pressure
Cheminert<sup>™</sup> 12-position valve from Valco Instruments. The
multi-port valve advances to the next desired port using a pneumatic
actuator powered by compressed air (bottle or 12 V compressor). Although the
valve advances through ports sequentially, the user can select the ports to
use with the Arduino controller. Three Arduino-controlled three-way solenoid
valves (Takasago MTV series) are used for different sampling and purging
configurations (Sect. 2.2). The Arduino board is fitted with an SD card
reader/writer for activity logging, an RTC clock for timekeeping, an LCD
panel<?pagebreak page5617?> for system output display, and operable switches for manual control.</p>
      <p id="d1e276">The system has been designed for unattended operation for long periods of
time (e.g., days or weeks), although it is limited by the spectrometer data
storage, fouling of the cuvette, and battery power (and sample storage of the
fractional volume collector if used). The time for a sampling sequence is
limited by the longest pumping time from furthest source. Ultimately this
determines the frequency of spectrometer measurements since the probe has a
set time interval between measurements. The sampling frequency for each
source depends on the sampling sequence time intervals and on the number
of sources (1 to 12).</p>
</sec>
<sec id="Ch1.S2.SS2">
  <title>System configurations</title>
      <p id="d1e285">Several configurations have been programmed to increase versatility of the
instrument and minimize cross-contamination between samples (Fig. 1) by
actuating one or more of the three-way valves using the Arduino control board.</p>
<sec id="Ch1.S2.SS2.SSS1">
  <title>Pumping from source to probe and purging back to source</title>
      <p id="d1e293">When it is necessary to purge all sample volume back to the source, the
system is configured as Fig. 1a during pumping (downward arrow on the
peristaltic pump) and as Fig. 1b during purging (upward arrow on the
peristaltic pump). To measure absorbance in the 1.1 mL cuvette used, a
minimum sample volume of <inline-formula><mml:math id="M8" display="inline"><mml:mrow><mml:mo>∼</mml:mo><mml:mn mathvariant="normal">7</mml:mn></mml:mrow></mml:math></inline-formula> mL is required, which includes
cuvette volume (<inline-formula><mml:math id="M9" display="inline"><mml:mrow><mml:msub><mml:mi>V</mml:mi><mml:mi mathvariant="normal">cuvette</mml:mi></mml:msub></mml:mrow></mml:math></inline-formula>) plus inline tubing volume. The system is
purged by air by running the pump in reverse. To minimize cross-contamination without using a deionized (DI) rinse, the cuvette can be rinsed by pumping
sample volume <inline-formula><mml:math id="M10" display="inline"><mml:mrow><mml:mo>&gt;</mml:mo><mml:mn mathvariant="normal">7</mml:mn></mml:mrow></mml:math></inline-formula> mL temporarily stored in the post-cuvette
storage volume.</p>
</sec>
<sec id="Ch1.S2.SS2.SSS2">
  <title>Purge to waste</title>
      <p id="d1e333">In this configuration, it is not desired that the sample be purged to the
source, so it is purged to waste (Fig. 1c).</p>
</sec>
<sec id="Ch1.S2.SS2.SSS3">
  <title>Pump to waste</title>
      <p id="d1e342">This configuration is used for purging residuals of the sample drawn from
the previous source <inline-formula><mml:math id="M11" display="inline"><mml:mrow><mml:mi>n</mml:mi><mml:mo>-</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:math></inline-formula> that remain in the tubing and rinsing with sample
volume from the current source <inline-formula><mml:math id="M12" display="inline"><mml:mi>n</mml:mi></mml:math></inline-formula> (Fig. 1d). After the estimated time for
new water from the current source to reach the waste valve has elapsed, the
system switches to the configuration in Fig. 1a for sample measurement by
probe.</p>
</sec>
<sec id="Ch1.S2.SS2.SSS4">
  <title>Fractional volume collection</title>
      <p id="d1e371">This configuration is used for collecting measured sample volumes to compare
values given by the probe to later lab analysis (Fig. 1e). The actual
sequence consists in purging the fractional volume collector (FVC) tubing with air using Fig. 1e
configuration but in the pumping mode (downward<?pagebreak page5618?> arrow on the peristaltic
pump, not shown) until water has passed the three-way valve closest to the FVC,
then use the Fig. 1c configuration to purge any cross-contaminated water to waste before
samples are sent to the FVC using the configuration in Fig. 1e. Any water left
in tubing after the FVC sample vial is full is purged to waste.</p>
</sec>
<sec id="Ch1.S2.SS2.SSS5">
  <title>DI water rinse</title>
      <p id="d1e380">Between each sample, the user may choose to rinse the tubing and cuvette
with DI water to create consistent cross-contamination between samples and
residual DI water droplets (Fig. 1f). This configuration draws water in
from a DI water source and pumps it through the lines and into the cuvette.
Consistent cleaning of the quartz cuvette decreases optical fouling over
time. The cuvette and post-cuvette storage volume are rinsed and the water
is then purged to waste.</p>
</sec>
</sec>
<sec id="Ch1.S2.SS3">
  <title>System testing</title>
      <p id="d1e390">In laboratory continuous flow systems, the risk for cross-contamination
between consecutive samples is mechanically minimized by having
unidirectional flow and by rinsing the lines with a carrier liquid between
samples. Our system has been designed to allow for bidirectional flow,
purging the lines instead with air. Because of surface tension forces
purging with air can leave micro-droplet residuals in the lines, opening the
possibility for cross-contamination between consecutive samples. This is
particularly problematic since sample volumes needed for analysis each time
are small by design. Although this is admittedly undesirable, this can still
be acceptable as long as the potential for contamination is evaluated and
solutions to minimize the risks are known. Potential solutions for
minimizing cross-contamination include a pre-measurement rinse with the
current source water or extended purging of the lines with air after each
measurement.</p>
      <p id="d1e393">Cross-contamination could arise from two processes. First, cuvette
contamination could occur when a water sample inside the cuvette during
instrument reading is contaminated by droplets from the previous sample,
either in the cuvette or in the MPS tubing. Second, cross-contamination of
the source, or source contamination, could occur when the “purging back to
source” configuration is used (Fig. 1b) and the source itself is
contaminated by residuals from other sources. Both contamination
possibilities were evaluated in two separate experiments. A third test of
performance quantified the relationship between sampling frequency and the
distance from the source to the system, since increased pumping time for a
sampling sequence leads to lower data frequency.</p>
      <p id="d1e396">Methods for evaluating cuvette contamination and source contamination were
identical to those used in Birgand et al. (2016). Alternating measurements
between sources of high and low <inline-formula><mml:math id="M13" display="inline"><mml:mrow class="chem"><mml:msubsup><mml:mi mathvariant="normal">NO</mml:mi><mml:mn mathvariant="normal">3</mml:mn><mml:mo>-</mml:mo></mml:msubsup></mml:mrow></mml:math></inline-formula> concentration
(<inline-formula><mml:math id="M14" display="inline"><mml:mrow><mml:mo>[</mml:mo><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">NO</mml:mi><mml:mn mathvariant="normal">3</mml:mn></mml:msub></mml:mrow><mml:msub><mml:mo>]</mml:mo><mml:mi mathvariant="normal">high</mml:mi></mml:msub></mml:mrow></mml:math></inline-formula> and <inline-formula><mml:math id="M15" display="inline"><mml:mrow><mml:mo>[</mml:mo><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">NO</mml:mi><mml:mn mathvariant="normal">3</mml:mn></mml:msub></mml:mrow><mml:msub><mml:mo>]</mml:mo><mml:mi mathvariant="normal">low</mml:mi></mml:msub></mml:mrow></mml:math></inline-formula>,
respectively) were used to determine contamination. The spectrophotometer's
estimates of <inline-formula><mml:math id="M16" display="inline"><mml:mrow class="chem"><mml:msubsup><mml:mi mathvariant="normal">NO</mml:mi><mml:mn mathvariant="normal">3</mml:mn><mml:mo>-</mml:mo></mml:msubsup></mml:mrow></mml:math></inline-formula> based on the absorbance fingerprint (method
detailed further in the Supplement) were used to quantify contamination. The
primary difference in testing the small-volume MPS for contamination between
sources was the size of the flow-through cell. In this system a 1.1 mL
flow-through quartz cuvette was used. In addition to testing cross-contamination when rinsing with sample volume from the current source, a DI
rinse was tested to see if it resulted in decreased contamination by
residuals.</p>
      <p id="d1e463">For testing pump timings, external tubes of various lengths were cut and
fitted to the inlet port of the system. The length of time required to pump
from the source to fill the cuvette and the time required to purge the line
were recorded. Pump times for each tube length were measured twice with use
of a stopwatch, and average pump time was recorded.</p>

<?xmltex \floatpos{t}?><table-wrap id="Ch1.T1" specific-use="star"><caption><p id="d1e470">Results of testing cross-contamination of cuvette. Treatment
indicates the volume of sample pumped from the current source for cuvette
rinsing relative to cuvette volume (<inline-formula><mml:math id="M17" display="inline"><mml:mrow><mml:msub><mml:mi>V</mml:mi><mml:mi mathvariant="normal">cuvette</mml:mi></mml:msub><mml:mo>)</mml:mo></mml:mrow></mml:math></inline-formula>, and whether or not
a prior DI rinse was used. C.I. denotes the confidence interval.</p></caption><oasis:table frame="topbot"><oasis:tgroup cols="8">
     <oasis:colspec colnum="1" colname="col1" align="left"/>
     <oasis:colspec colnum="2" colname="col2" align="left"/>
     <oasis:colspec colnum="3" colname="col3" align="center"/>
     <oasis:colspec colnum="4" colname="col4" align="center" colsep="1"/>
     <oasis:colspec colnum="5" colname="col5" align="right"/>
     <oasis:colspec colnum="6" colname="col6" align="right" colsep="1"/>
     <oasis:colspec colnum="7" colname="col7" align="right"/>
     <oasis:colspec colnum="8" colname="col8" align="right"/>
     <oasis:thead>
       <oasis:row>
         <oasis:entry colname="col1">Trial</oasis:entry>
         <oasis:entry colname="col2">Treatment</oasis:entry>
         <oasis:entry namest="col3" nameend="col4" colsep="1">Initial </oasis:entry>
         <oasis:entry namest="col5" nameend="col6" align="center" colsep="1"><inline-formula><mml:math id="M21" display="inline"><mml:mi>p</mml:mi></mml:math></inline-formula> value for  </oasis:entry>
         <oasis:entry namest="col7" nameend="col8" align="center">95 % C.I. for </oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1">no.</oasis:entry>
         <oasis:entry colname="col2"/>
         <oasis:entry namest="col3" nameend="col4" colsep="1">concentrations </oasis:entry>
         <oasis:entry namest="col5" nameend="col6" align="center" colsep="1">difference in </oasis:entry>
         <oasis:entry namest="col7" nameend="col8" align="center">difference in means </oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1"/>
         <oasis:entry colname="col2"/>
         <oasis:entry rowsep="1" namest="col3" nameend="col4" colsep="1">(mg <inline-formula><mml:math id="M22" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">NO</mml:mi><mml:mn mathvariant="normal">3</mml:mn></mml:msub><mml:mo>-</mml:mo><mml:mi mathvariant="normal">N</mml:mi></mml:mrow></mml:math></inline-formula> L<inline-formula><mml:math id="M23" display="inline"><mml:msup><mml:mi/><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:msup></mml:math></inline-formula>) </oasis:entry>
         <oasis:entry rowsep="1" namest="col5" nameend="col6" align="center" colsep="1">means of </oasis:entry>
         <oasis:entry rowsep="1" namest="col7" nameend="col8" align="center">(mg <inline-formula><mml:math id="M24" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">NO</mml:mi><mml:mn mathvariant="normal">3</mml:mn></mml:msub><mml:mo>-</mml:mo><mml:mi mathvariant="normal">N</mml:mi></mml:mrow></mml:math></inline-formula> L<inline-formula><mml:math id="M25" display="inline"><mml:msup><mml:mi/><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:msup></mml:math></inline-formula>) </oasis:entry>
       </oasis:row>
       <oasis:row rowsep="1">
         <oasis:entry colname="col1"/>
         <oasis:entry colname="col2"/>
         <oasis:entry colname="col3"><inline-formula><mml:math id="M26" display="inline"><mml:mrow><mml:mo>[</mml:mo><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">NO</mml:mi><mml:mn mathvariant="normal">3</mml:mn></mml:msub></mml:mrow><mml:msub><mml:mo>]</mml:mo><mml:mi mathvariant="normal">High</mml:mi></mml:msub></mml:mrow></mml:math></inline-formula></oasis:entry>
         <oasis:entry colname="col4"><inline-formula><mml:math id="M27" display="inline"><mml:mrow><mml:mo>[</mml:mo><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">NO</mml:mi><mml:mn mathvariant="normal">3</mml:mn></mml:msub></mml:mrow><mml:msub><mml:mo>]</mml:mo><mml:mi mathvariant="normal">Low</mml:mi></mml:msub></mml:mrow></mml:math></inline-formula></oasis:entry>
         <oasis:entry colname="col5"><inline-formula><mml:math id="M28" display="inline"><mml:mrow><mml:mo>[</mml:mo><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">NO</mml:mi><mml:mn mathvariant="normal">3</mml:mn></mml:msub></mml:mrow><mml:msub><mml:mo>]</mml:mo><mml:mi mathvariant="normal">High</mml:mi></mml:msub></mml:mrow></mml:math></inline-formula></oasis:entry>
         <oasis:entry colname="col6"><inline-formula><mml:math id="M29" display="inline"><mml:mrow><mml:mo>[</mml:mo><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">NO</mml:mi><mml:mn mathvariant="normal">3</mml:mn></mml:msub></mml:mrow><mml:msub><mml:mo>]</mml:mo><mml:mi mathvariant="normal">Low</mml:mi></mml:msub></mml:mrow></mml:math></inline-formula></oasis:entry>
         <oasis:entry colname="col7"><inline-formula><mml:math id="M30" display="inline"><mml:mrow><mml:mo>[</mml:mo><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">NO</mml:mi><mml:mn mathvariant="normal">3</mml:mn></mml:msub></mml:mrow><mml:msub><mml:mo>]</mml:mo><mml:mi mathvariant="normal">High</mml:mi></mml:msub></mml:mrow></mml:math></inline-formula></oasis:entry>
         <oasis:entry colname="col8">low <inline-formula><mml:math id="M31" display="inline"><mml:mrow class="chem"><mml:msubsup><mml:mi mathvariant="normal">NO</mml:mi><mml:mn mathvariant="normal">3</mml:mn><mml:mo>-</mml:mo></mml:msubsup></mml:mrow></mml:math></inline-formula> source</oasis:entry>
       </oasis:row>
     </oasis:thead>
     <oasis:tbody>
       <oasis:row>
         <oasis:entry colname="col1">1</oasis:entry>
         <oasis:entry colname="col2"><inline-formula><mml:math id="M32" display="inline"><mml:mrow><mml:mn mathvariant="normal">2</mml:mn><mml:mo>×</mml:mo><mml:msub><mml:mi>V</mml:mi><mml:mi mathvariant="normal">cuvette</mml:mi></mml:msub></mml:mrow></mml:math></inline-formula></oasis:entry>
         <oasis:entry colname="col3"><inline-formula><mml:math id="M33" display="inline"><mml:mrow><mml:mn mathvariant="normal">14.71</mml:mn><mml:mo>±</mml:mo><mml:mn mathvariant="normal">0.02</mml:mn></mml:mrow></mml:math></inline-formula></oasis:entry>
         <oasis:entry colname="col4"><inline-formula><mml:math id="M34" display="inline"><mml:mrow><mml:mn mathvariant="normal">0.12</mml:mn><mml:mo>±</mml:mo><mml:mn mathvariant="normal">0.01</mml:mn></mml:mrow></mml:math></inline-formula></oasis:entry>
         <oasis:entry colname="col5"><inline-formula><mml:math id="M35" display="inline"><mml:mrow><mml:mo>&lt;</mml:mo><mml:mn mathvariant="normal">0.0001</mml:mn></mml:mrow></mml:math></inline-formula></oasis:entry>
         <oasis:entry colname="col6"><inline-formula><mml:math id="M36" display="inline"><mml:mrow><mml:mo>&lt;</mml:mo><mml:mn mathvariant="normal">0.0002</mml:mn></mml:mrow></mml:math></inline-formula></oasis:entry>
         <oasis:entry colname="col7">(<inline-formula><mml:math id="M37" display="inline"><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">1.59</mml:mn></mml:mrow></mml:math></inline-formula>, <inline-formula><mml:math id="M38" display="inline"><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">1.37</mml:mn></mml:mrow></mml:math></inline-formula>)</oasis:entry>
         <oasis:entry colname="col8">(1.29, 2.10)</oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1">2</oasis:entry>
         <oasis:entry colname="col2"><inline-formula><mml:math id="M39" display="inline"><mml:mrow><mml:mn mathvariant="normal">4</mml:mn><mml:mo>×</mml:mo><mml:msub><mml:mi>V</mml:mi><mml:mi mathvariant="normal">cuvette</mml:mi></mml:msub></mml:mrow></mml:math></inline-formula></oasis:entry>
         <oasis:entry colname="col3"><inline-formula><mml:math id="M40" display="inline"><mml:mrow><mml:mn mathvariant="normal">14.71</mml:mn><mml:mo>±</mml:mo><mml:mn mathvariant="normal">0.01</mml:mn></mml:mrow></mml:math></inline-formula></oasis:entry>
         <oasis:entry colname="col4"><inline-formula><mml:math id="M41" display="inline"><mml:mrow><mml:mn mathvariant="normal">0.09</mml:mn><mml:mo>±</mml:mo><mml:mn mathvariant="normal">0.01</mml:mn></mml:mrow></mml:math></inline-formula></oasis:entry>
         <oasis:entry colname="col5"><inline-formula><mml:math id="M42" display="inline"><mml:mrow><mml:mo>&lt;</mml:mo><mml:mn mathvariant="normal">0.0001</mml:mn></mml:mrow></mml:math></inline-formula></oasis:entry>
         <oasis:entry colname="col6"><inline-formula><mml:math id="M43" display="inline"><mml:mrow><mml:mo>&lt;</mml:mo><mml:mn mathvariant="normal">0.0001</mml:mn></mml:mrow></mml:math></inline-formula></oasis:entry>
         <oasis:entry colname="col7">(<inline-formula><mml:math id="M44" display="inline"><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">0.19</mml:mn></mml:mrow></mml:math></inline-formula>, <inline-formula><mml:math id="M45" display="inline"><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">0.14</mml:mn></mml:mrow></mml:math></inline-formula>)</oasis:entry>
         <oasis:entry colname="col8">(0.15, 0.18)</oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1">3</oasis:entry>
         <oasis:entry colname="col2"><inline-formula><mml:math id="M46" display="inline"><mml:mrow><mml:mn mathvariant="normal">10</mml:mn><mml:mo>×</mml:mo><mml:msub><mml:mi>V</mml:mi><mml:mi mathvariant="normal">cuvette</mml:mi></mml:msub></mml:mrow></mml:math></inline-formula></oasis:entry>
         <oasis:entry colname="col3"><inline-formula><mml:math id="M47" display="inline"><mml:mrow><mml:mn mathvariant="normal">14.75</mml:mn><mml:mo>±</mml:mo><mml:mn mathvariant="normal">0.01</mml:mn></mml:mrow></mml:math></inline-formula></oasis:entry>
         <oasis:entry colname="col4"><inline-formula><mml:math id="M48" display="inline"><mml:mrow><mml:mn mathvariant="normal">0.06</mml:mn><mml:mo>±</mml:mo><mml:mn mathvariant="normal">0.01</mml:mn></mml:mrow></mml:math></inline-formula></oasis:entry>
         <oasis:entry colname="col5">0.236<inline-formula><mml:math id="M49" display="inline"><mml:msup><mml:mi/><mml:mo>*</mml:mo></mml:msup></mml:math></inline-formula></oasis:entry>
         <oasis:entry colname="col6"><inline-formula><mml:math id="M50" display="inline"><mml:mrow><mml:mo>&lt;</mml:mo><mml:mn mathvariant="normal">0.0001</mml:mn></mml:mrow></mml:math></inline-formula></oasis:entry>
         <oasis:entry colname="col7">(<inline-formula><mml:math id="M51" display="inline"><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">0.03</mml:mn></mml:mrow></mml:math></inline-formula>, 0.01)</oasis:entry>
         <oasis:entry colname="col8">(0.06, 0.09)</oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1">4</oasis:entry>
         <oasis:entry colname="col2">DI rinse, <inline-formula><mml:math id="M52" display="inline"><mml:mrow><mml:mn mathvariant="normal">2</mml:mn><mml:mo>×</mml:mo><mml:msub><mml:mi>V</mml:mi><mml:mi mathvariant="normal">cuvette</mml:mi></mml:msub></mml:mrow></mml:math></inline-formula>,</oasis:entry>
         <oasis:entry colname="col3"><inline-formula><mml:math id="M53" display="inline"><mml:mrow><mml:mn mathvariant="normal">14.74</mml:mn><mml:mo>±</mml:mo><mml:mn mathvariant="normal">0.01</mml:mn></mml:mrow></mml:math></inline-formula></oasis:entry>
         <oasis:entry colname="col4"><inline-formula><mml:math id="M54" display="inline"><mml:mrow><mml:mn mathvariant="normal">0.08</mml:mn><mml:mo>±</mml:mo><mml:mn mathvariant="normal">0.01</mml:mn></mml:mrow></mml:math></inline-formula></oasis:entry>
         <oasis:entry colname="col5"><inline-formula><mml:math id="M55" display="inline"><mml:mrow><mml:mo>&lt;</mml:mo><mml:mn mathvariant="normal">0.0001</mml:mn></mml:mrow></mml:math></inline-formula></oasis:entry>
         <oasis:entry colname="col6"><inline-formula><mml:math id="M56" display="inline"><mml:mrow><mml:mo>&lt;</mml:mo><mml:mn mathvariant="normal">0.0001</mml:mn></mml:mrow></mml:math></inline-formula></oasis:entry>
         <oasis:entry colname="col7">(<inline-formula><mml:math id="M57" display="inline"><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">1.74</mml:mn></mml:mrow></mml:math></inline-formula>, <inline-formula><mml:math id="M58" display="inline"><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">1.41</mml:mn></mml:mrow></mml:math></inline-formula>)</oasis:entry>
         <oasis:entry colname="col8">(0.28, 0.35)</oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1">5</oasis:entry>
         <oasis:entry colname="col2">DI rinse, <inline-formula><mml:math id="M59" display="inline"><mml:mrow><mml:mn mathvariant="normal">4</mml:mn><mml:mo>×</mml:mo><mml:msub><mml:mi>V</mml:mi><mml:mi mathvariant="normal">cuvette</mml:mi></mml:msub></mml:mrow></mml:math></inline-formula></oasis:entry>
         <oasis:entry colname="col3"><inline-formula><mml:math id="M60" display="inline"><mml:mrow><mml:mn mathvariant="normal">14.74</mml:mn><mml:mo>±</mml:mo><mml:mn mathvariant="normal">0.01</mml:mn></mml:mrow></mml:math></inline-formula></oasis:entry>
         <oasis:entry colname="col4"><inline-formula><mml:math id="M61" display="inline"><mml:mrow><mml:mn mathvariant="normal">0.11</mml:mn><mml:mo>±</mml:mo><mml:mn mathvariant="normal">0.02</mml:mn></mml:mrow></mml:math></inline-formula></oasis:entry>
         <oasis:entry colname="col5"><inline-formula><mml:math id="M62" display="inline"><mml:mrow><mml:mo>&lt;</mml:mo><mml:mn mathvariant="normal">0.0001</mml:mn></mml:mrow></mml:math></inline-formula></oasis:entry>
         <oasis:entry colname="col6"><inline-formula><mml:math id="M63" display="inline"><mml:mrow><mml:mo>&lt;</mml:mo><mml:mn mathvariant="normal">0.0001</mml:mn></mml:mrow></mml:math></inline-formula></oasis:entry>
         <oasis:entry colname="col7">(<inline-formula><mml:math id="M64" display="inline"><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">0.11</mml:mn></mml:mrow></mml:math></inline-formula>, <inline-formula><mml:math id="M65" display="inline"><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">0.07</mml:mn></mml:mrow></mml:math></inline-formula>)</oasis:entry>
         <oasis:entry colname="col8">(0.04,0.08)</oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1">6</oasis:entry>
         <oasis:entry colname="col2">DI rinse, <inline-formula><mml:math id="M66" display="inline"><mml:mrow><mml:mn mathvariant="normal">10</mml:mn><mml:mo>×</mml:mo><mml:msub><mml:mi>V</mml:mi><mml:mi mathvariant="normal">cuvette</mml:mi></mml:msub></mml:mrow></mml:math></inline-formula></oasis:entry>
         <oasis:entry colname="col3"><inline-formula><mml:math id="M67" display="inline"><mml:mrow><mml:mn mathvariant="normal">15.14</mml:mn><mml:mo>±</mml:mo><mml:mn mathvariant="normal">0.01</mml:mn></mml:mrow></mml:math></inline-formula></oasis:entry>
         <oasis:entry colname="col4"><inline-formula><mml:math id="M68" display="inline"><mml:mrow><mml:mn mathvariant="normal">0.09</mml:mn><mml:mo>±</mml:mo><mml:mn mathvariant="normal">0.02</mml:mn></mml:mrow></mml:math></inline-formula></oasis:entry>
         <oasis:entry colname="col5">0.003</oasis:entry>
         <oasis:entry colname="col6">0.615<inline-formula><mml:math id="M69" display="inline"><mml:msup><mml:mi/><mml:mo>*</mml:mo></mml:msup></mml:math></inline-formula></oasis:entry>
         <oasis:entry colname="col7">(<inline-formula><mml:math id="M70" display="inline"><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">0.06</mml:mn></mml:mrow></mml:math></inline-formula>, <inline-formula><mml:math id="M71" display="inline"><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">0.02</mml:mn></mml:mrow></mml:math></inline-formula>)</oasis:entry>
         <oasis:entry colname="col8">(<inline-formula><mml:math id="M72" display="inline"><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">0.02</mml:mn></mml:mrow></mml:math></inline-formula>, 0.04)</oasis:entry>
       </oasis:row>
     </oasis:tbody>
   </oasis:tgroup></oasis:table><table-wrap-foot><p id="d1e486"><inline-formula><mml:math id="M18" display="inline"><mml:msup><mml:mi/><mml:mo>*</mml:mo></mml:msup></mml:math></inline-formula> indicates that the protocol used resulted in no
significant difference between the initial <inline-formula><mml:math id="M19" display="inline"><mml:mrow class="chem"><mml:msubsup><mml:mi mathvariant="normal">NO</mml:mi><mml:mn mathvariant="normal">3</mml:mn><mml:mo>-</mml:mo></mml:msubsup></mml:mrow></mml:math></inline-formula> concentration and
subsequent measurements (<inline-formula><mml:math id="M20" display="inline"><mml:mrow><mml:mi mathvariant="italic">α</mml:mi><mml:mo>=</mml:mo><mml:mn mathvariant="normal">0.05</mml:mn></mml:mrow></mml:math></inline-formula>).</p></table-wrap-foot></table-wrap>

<?xmltex \floatpos{t}?><table-wrap id="Ch1.T2" specific-use="star"><caption><p id="d1e1367">Initial <inline-formula><mml:math id="M73" display="inline"><mml:mrow class="chem"><mml:msubsup><mml:mi mathvariant="normal">NO</mml:mi><mml:mn mathvariant="normal">3</mml:mn><mml:mo>-</mml:mo></mml:msubsup></mml:mrow></mml:math></inline-formula> concentrations, calculated effective
residual volumes (Vres), and 95 % confidence interval (C.I.) from source
contamination trials (a)–(d).</p></caption><oasis:table frame="topbot"><oasis:tgroup cols="7">
     <oasis:colspec colnum="1" colname="col1" align="left"/>
     <oasis:colspec colnum="2" colname="col2" align="center"/>
     <oasis:colspec colnum="3" colname="col3" align="center"/>
     <oasis:colspec colnum="4" colname="col4" align="center" colsep="1"/>
     <oasis:colspec colnum="5" colname="col5" align="right"/>
     <oasis:colspec colnum="6" colname="col6" align="center"/>
     <oasis:colspec colnum="7" colname="col7" align="center"/>
     <oasis:thead>
       <oasis:row>
         <oasis:entry colname="col1"/>
         <oasis:entry rowsep="1" namest="col2" nameend="col4" colsep="1"><inline-formula><mml:math id="M74" display="inline"><mml:mrow><mml:mo>[</mml:mo><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">NO</mml:mi><mml:mn mathvariant="normal">3</mml:mn></mml:msub></mml:mrow><mml:msub><mml:mo>]</mml:mo><mml:mi mathvariant="normal">low</mml:mi></mml:msub></mml:mrow></mml:math></inline-formula></oasis:entry>
         <oasis:entry rowsep="1" namest="col5" nameend="col7" align="center"><inline-formula><mml:math id="M75" display="inline"><mml:mrow><mml:mo>[</mml:mo><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">NO</mml:mi><mml:mn mathvariant="normal">3</mml:mn></mml:msub></mml:mrow><mml:msub><mml:mo>]</mml:mo><mml:mi mathvariant="normal">high</mml:mi></mml:msub></mml:mrow></mml:math></inline-formula></oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1">Trial</oasis:entry>
         <oasis:entry colname="col2">Initial concentration</oasis:entry>
         <oasis:entry colname="col3"><inline-formula><mml:math id="M76" display="inline"><mml:mrow><mml:msub><mml:mi>V</mml:mi><mml:mi mathvariant="normal">res</mml:mi></mml:msub></mml:mrow></mml:math></inline-formula></oasis:entry>
         <oasis:entry colname="col4">95 % C.I.</oasis:entry>
         <oasis:entry colname="col5">Initial concentration</oasis:entry>
         <oasis:entry colname="col6"><inline-formula><mml:math id="M77" display="inline"><mml:mrow><mml:msub><mml:mi>V</mml:mi><mml:mi mathvariant="normal">res</mml:mi></mml:msub></mml:mrow></mml:math></inline-formula></oasis:entry>
         <oasis:entry colname="col7">95 % C.I.</oasis:entry>
       </oasis:row>
       <oasis:row rowsep="1">
         <oasis:entry colname="col1"/>
         <oasis:entry colname="col2">(mg <inline-formula><mml:math id="M78" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">NO</mml:mi><mml:mn mathvariant="normal">3</mml:mn></mml:msub><mml:mo>-</mml:mo><mml:mi mathvariant="normal">N</mml:mi></mml:mrow></mml:math></inline-formula> L<inline-formula><mml:math id="M79" display="inline"><mml:msup><mml:mi/><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:msup></mml:math></inline-formula>)</oasis:entry>
         <oasis:entry colname="col3">(mL)</oasis:entry>
         <oasis:entry colname="col4">(mL)</oasis:entry>
         <oasis:entry colname="col5">(mg <inline-formula><mml:math id="M80" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">NO</mml:mi><mml:mn mathvariant="normal">3</mml:mn></mml:msub><mml:mo>-</mml:mo><mml:mi mathvariant="normal">N</mml:mi></mml:mrow></mml:math></inline-formula> L<inline-formula><mml:math id="M81" display="inline"><mml:msup><mml:mi/><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:msup></mml:math></inline-formula>)</oasis:entry>
         <oasis:entry colname="col6">(mL)</oasis:entry>
         <oasis:entry colname="col7">(mL)</oasis:entry>
       </oasis:row>
     </oasis:thead>
     <oasis:tbody>
       <oasis:row>
         <oasis:entry colname="col1">(a)</oasis:entry>
         <oasis:entry colname="col2">0.71</oasis:entry>
         <oasis:entry colname="col3">0.41</oasis:entry>
         <oasis:entry colname="col4">(0.39, 0.43)</oasis:entry>
         <oasis:entry colname="col5">15.3</oasis:entry>
         <oasis:entry colname="col6">0.32</oasis:entry>
         <oasis:entry colname="col7">(0.29, 0.35)</oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1">(b)</oasis:entry>
         <oasis:entry colname="col2">0.71</oasis:entry>
         <oasis:entry colname="col3">0.35</oasis:entry>
         <oasis:entry colname="col4">(0.32, 0.38)</oasis:entry>
         <oasis:entry colname="col5">8.63</oasis:entry>
         <oasis:entry colname="col6">0.39</oasis:entry>
         <oasis:entry colname="col7">(0.34, 0.43)</oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1">(c)</oasis:entry>
         <oasis:entry colname="col2">0.74</oasis:entry>
         <oasis:entry colname="col3">0.46</oasis:entry>
         <oasis:entry colname="col4">(0.38, 0.55)</oasis:entry>
         <oasis:entry colname="col5">4.80</oasis:entry>
         <oasis:entry colname="col6">0.28</oasis:entry>
         <oasis:entry colname="col7">(0.21, 0.36)</oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1">(d)</oasis:entry>
         <oasis:entry colname="col2">0.78</oasis:entry>
         <oasis:entry colname="col3">0.30</oasis:entry>
         <oasis:entry colname="col4">(0.06, 0.52)</oasis:entry>
         <oasis:entry colname="col5">2.52</oasis:entry>
         <oasis:entry colname="col6">0.39</oasis:entry>
         <oasis:entry colname="col7">(0.15, 0.60)</oasis:entry>
       </oasis:row>
     </oasis:tbody>
   </oasis:tgroup></oasis:table></table-wrap>

<sec id="Ch1.S2.SS3.SSS1">
  <title>Cross-contamination results</title>
      <p id="d1e1680">The cross-contamination trial results are summarized in Table 1. The first
two columns report <inline-formula><mml:math id="M82" display="inline"><mml:mi>p</mml:mi></mml:math></inline-formula> values testing for a significant difference (<inline-formula><mml:math id="M83" display="inline"><mml:mrow><mml:mi mathvariant="italic">α</mml:mi><mml:mo>=</mml:mo><mml:mn mathvariant="normal">0.05</mml:mn></mml:mrow></mml:math></inline-formula>) between spectrophotometric estimates of <inline-formula><mml:math id="M84" display="inline"><mml:mrow class="chem"><mml:msubsup><mml:mi mathvariant="normal">NO</mml:mi><mml:mn mathvariant="normal">3</mml:mn><mml:mo>-</mml:mo></mml:msubsup></mml:mrow></mml:math></inline-formula> concentration
in the source (10 repeated measurements) and subsequent 10 measurements after
pumping sample volume from the alternate <inline-formula><mml:math id="M85" display="inline"><mml:mrow class="chem"><mml:msubsup><mml:mi mathvariant="normal">NO</mml:mi><mml:mn mathvariant="normal">3</mml:mn><mml:mo>-</mml:mo></mml:msubsup></mml:mrow></mml:math></inline-formula> source between each
measurement (i.e., if <inline-formula><mml:math id="M86" display="inline"><mml:mrow><mml:mi>p</mml:mi><mml:mo>&gt;</mml:mo><mml:mn mathvariant="normal">0.05</mml:mn></mml:mrow></mml:math></inline-formula>, there was no statistical difference between
initial and subsequent measurements for <inline-formula><mml:math id="M87" display="inline"><mml:mrow class="chem"><mml:msubsup><mml:mi mathvariant="normal">NO</mml:mi><mml:mn mathvariant="normal">3</mml:mn><mml:mo>-</mml:mo></mml:msubsup></mml:mrow></mml:math></inline-formula>, implying negligible
cross-contamination). The results show that without a DI rinse and when
measuring high-concentration samples after low-concentration samples, the
cuvette must be rinsed with the current sample by at least <inline-formula><mml:math id="M88" display="inline"><mml:mrow><mml:mn mathvariant="normal">10</mml:mn><mml:mo>×</mml:mo><mml:msub><mml:mi>V</mml:mi><mml:mi mathvariant="normal">cuvette</mml:mi></mml:msub></mml:mrow></mml:math></inline-formula> to make cuvette contamination by the previous sample
negligible. With only rinsing <inline-formula><mml:math id="M89" display="inline"><mml:mrow><mml:mn mathvariant="normal">2</mml:mn><mml:mo>×</mml:mo><mml:msub><mml:mi>V</mml:mi><mml:mi mathvariant="normal">cuvette</mml:mi></mml:msub></mml:mrow></mml:math></inline-formula>, concentrations
were underestimated at about 13.25 mg <inline-formula><mml:math id="M90" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">NO</mml:mi><mml:mn mathvariant="normal">3</mml:mn></mml:msub><mml:mo>-</mml:mo><mml:mi mathvariant="normal">N</mml:mi></mml:mrow></mml:math></inline-formula> L<inline-formula><mml:math id="M91" display="inline"><mml:msup><mml:mi/><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:msup></mml:math></inline-formula>, lower than
the [<inline-formula><mml:math id="M92" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">NO</mml:mi><mml:mn mathvariant="normal">3</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula>]<inline-formula><mml:math id="M93" display="inline"><mml:mrow><mml:msub><mml:mi/><mml:mi mathvariant="normal">high</mml:mi></mml:msub><mml:mo>=</mml:mo><mml:mn mathvariant="normal">14.72</mml:mn></mml:mrow></mml:math></inline-formula> mg <inline-formula><mml:math id="M94" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">NO</mml:mi><mml:mn mathvariant="normal">3</mml:mn></mml:msub><mml:mo>-</mml:mo><mml:mi mathvariant="normal">N</mml:mi></mml:mrow></mml:math></inline-formula> L<inline-formula><mml:math id="M95" display="inline"><mml:msup><mml:mi/><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:msup></mml:math></inline-formula>
reference. Cross-contamination was divided by 10 by rinsing with <inline-formula><mml:math id="M96" display="inline"><mml:mrow><mml:mn mathvariant="normal">4</mml:mn><mml:mo>×</mml:mo><mml:msub><mml:mi>V</mml:mi><mml:mi mathvariant="normal">cuvette</mml:mi></mml:msub></mml:mrow></mml:math></inline-formula>, but was still measurable and significant.</p>
      <p id="d1e1879">For the low-concentration samples measured after high concentrations, rinsing
<inline-formula><mml:math id="M97" display="inline"><mml:mrow><mml:mn mathvariant="normal">10</mml:mn><mml:mo>×</mml:mo><mml:msub><mml:mi>V</mml:mi><mml:mi mathvariant="normal">cuvette</mml:mi></mml:msub></mml:mrow></mml:math></inline-formula> could not fully eliminate cross-contamination as it still appeared to be significant, yielding readings
around 0.14 mg <inline-formula><mml:math id="M98" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">NO</mml:mi><mml:mn mathvariant="normal">3</mml:mn></mml:msub><mml:mo>-</mml:mo><mml:mi mathvariant="normal">N</mml:mi></mml:mrow></mml:math></inline-formula> L<inline-formula><mml:math id="M99" display="inline"><mml:msup><mml:mi/><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:msup></mml:math></inline-formula> instead of the initial
0.06 mg <inline-formula><mml:math id="M100" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">NO</mml:mi><mml:mn mathvariant="normal">3</mml:mn></mml:msub><mml:mo>-</mml:mo><mml:mi mathvariant="normal">N</mml:mi></mml:mrow></mml:math></inline-formula> L<inline-formula><mml:math id="M101" display="inline"><mml:msup><mml:mi/><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:msup></mml:math></inline-formula>. Adding a DI rinse appeared to eliminate
cross-contamination for [<inline-formula><mml:math id="M102" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">NO</mml:mi><mml:mn mathvariant="normal">3</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula>]<inline-formula><mml:math id="M103" display="inline"><mml:msub><mml:mi/><mml:mi mathvariant="normal">low</mml:mi></mml:msub></mml:math></inline-formula> by rinsing with <inline-formula><mml:math id="M104" display="inline"><mml:mrow><mml:mn mathvariant="normal">10</mml:mn><mml:mo>×</mml:mo><mml:msub><mml:mi>V</mml:mi><mml:mi mathvariant="normal">cuvette</mml:mi></mml:msub></mml:mrow></mml:math></inline-formula> (<inline-formula><mml:math id="M105" display="inline"><mml:mrow><mml:mo>&lt;</mml:mo><mml:mn mathvariant="normal">0.01</mml:mn></mml:mrow></mml:math></inline-formula> mg L<inline-formula><mml:math id="M106" display="inline"><mml:msup><mml:mi/><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:msup></mml:math></inline-formula> difference), but the same
treatment significantly diluted [<inline-formula><mml:math id="M107" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">NO</mml:mi><mml:mn mathvariant="normal">3</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula>]<inline-formula><mml:math id="M108" display="inline"><mml:msub><mml:mi/><mml:mi mathvariant="normal">high</mml:mi></mml:msub></mml:math></inline-formula>.</p>
      <?pagebreak page5619?><p id="d1e2030">These results suggest that there is not one solution to fully eliminate
cross-contamination when consecutive samples differ drastically in solute
concentration. These results were obtained for extreme changes of conditions
for which consecutive concentrations were roughly 150-fold different. For
applications in which this ratio may be common between consecutive samples,
rinsing with <inline-formula><mml:math id="M109" display="inline"><mml:mrow><mml:mo>&gt;</mml:mo><mml:mn mathvariant="normal">10</mml:mn><mml:mo>×</mml:mo><mml:msub><mml:mi>V</mml:mi><mml:mi mathvariant="normal">cuvette</mml:mi></mml:msub></mml:mrow></mml:math></inline-formula> is recommended and values for
lower concentration should be taken with caution. For most applications,
however, such ratios between consecutive concentrations are unlikely. For
ratios of 50, 10, and 5 (i.e 0.50 to 25.0, 0.5 to 5.0, and 0.5 to
2.5 mg <inline-formula><mml:math id="M110" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">NO</mml:mi><mml:mn mathvariant="normal">3</mml:mn></mml:msub><mml:mo>-</mml:mo><mml:mi mathvariant="normal">N</mml:mi></mml:mrow></mml:math></inline-formula> L<inline-formula><mml:math id="M111" display="inline"><mml:msup><mml:mi/><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:msup></mml:math></inline-formula>), the differences in mean concentrations
reported in Table 1 would be divided by a factor of 3, 10, and 30,
respectively. Rinsing with <inline-formula><mml:math id="M112" display="inline"><mml:mrow><mml:mn mathvariant="normal">4</mml:mn><mml:mo>×</mml:mo><mml:msub><mml:mi>V</mml:mi><mml:mi mathvariant="normal">cuvette</mml:mi></mml:msub></mml:mrow></mml:math></inline-formula> would reduce the
absolute concentration difference from 0.19 mg <inline-formula><mml:math id="M113" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">NO</mml:mi><mml:mn mathvariant="normal">3</mml:mn></mml:msub><mml:mo>-</mml:mo><mml:mi mathvariant="normal">N</mml:mi></mml:mrow></mml:math></inline-formula> L<inline-formula><mml:math id="M114" display="inline"><mml:msup><mml:mi/><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:msup></mml:math></inline-formula> in
the worst-case scenario to 0.06, 0.02, and less than
0.01 mg <inline-formula><mml:math id="M115" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">NO</mml:mi><mml:mn mathvariant="normal">3</mml:mn></mml:msub><mml:mo>-</mml:mo><mml:mi mathvariant="normal">N</mml:mi></mml:mrow></mml:math></inline-formula> L<inline-formula><mml:math id="M116" display="inline"><mml:msup><mml:mi/><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:msup></mml:math></inline-formula>, respectively, although the concentrations
may still be significantly over- or underestimated. These values are within
the 5 % measurement uncertainties often found to be acceptable from
analytical instruments.</p>

      <?xmltex \floatpos{t}?><fig id="Ch1.F2" specific-use="star"><caption><p id="d1e2149">Changes in <inline-formula><mml:math id="M117" display="inline"><mml:mrow class="chem"><mml:msubsup><mml:mi mathvariant="normal">NO</mml:mi><mml:mn mathvariant="normal">3</mml:mn><mml:mo>-</mml:mo></mml:msubsup></mml:mrow></mml:math></inline-formula> concentrations in low
(<inline-formula><mml:math id="M118" display="inline"><mml:mrow><mml:mo>[</mml:mo><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">NO</mml:mi><mml:mn mathvariant="normal">3</mml:mn></mml:msub></mml:mrow><mml:msub><mml:mo>]</mml:mo><mml:mi mathvariant="normal">low</mml:mi></mml:msub><mml:mo>)</mml:mo></mml:mrow></mml:math></inline-formula> and high (<inline-formula><mml:math id="M119" display="inline"><mml:mrow><mml:mo>[</mml:mo><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">NO</mml:mi><mml:mn mathvariant="normal">3</mml:mn></mml:msub></mml:mrow><mml:msub><mml:mo>]</mml:mo><mml:mi mathvariant="normal">high</mml:mi></mml:msub><mml:mo>)</mml:mo></mml:mrow></mml:math></inline-formula>
concentration sources (0.5 L) resulting from residual volumes purged to the
alternate source. Greater concentration or dilution effects were seen with
increasing differences in initial <inline-formula><mml:math id="M120" display="inline"><mml:mrow class="chem"><mml:msubsup><mml:mi mathvariant="normal">NO</mml:mi><mml:mn mathvariant="normal">3</mml:mn><mml:mo>-</mml:mo></mml:msubsup></mml:mrow></mml:math></inline-formula> concentrations of the
sources during trials <bold>(a)</bold>–<bold>(d)</bold>.</p></caption>
            <?xmltex \igopts{width=284.527559pt}?><graphic xlink:href="https://hess.copernicus.org/articles/22/5615/2018/hess-22-5615-2018-f02.png"/>

          </fig>

</sec>
<sec id="Ch1.S2.SS3.SSS2">
  <title>Source contamination</title>
      <p id="d1e2239">Source contamination (or cross-contamination of the source) testing results
are shown in Fig. 2. As expected, [<inline-formula><mml:math id="M121" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">NO</mml:mi><mml:mn mathvariant="normal">3</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula>]<inline-formula><mml:math id="M122" display="inline"><mml:msub><mml:mi/><mml:mi mathvariant="normal">high</mml:mi></mml:msub></mml:math></inline-formula> and
[<inline-formula><mml:math id="M123" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">NO</mml:mi><mml:mn mathvariant="normal">3</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula>]<inline-formula><mml:math id="M124" display="inline"><mml:msub><mml:mi/><mml:mi mathvariant="normal">low</mml:mi></mml:msub></mml:math></inline-formula> became diluted and concentrated, respectively,
as residual volumes from the previous samples contaminated the sources. This
source contamination increased with increasing difference in initial
concentrations (Fig. 2 and Table 3). Over 40 purges back to the source, the
concentration and dilution effects were approximately linear, and regression
lines were fitted to the data to calculate effective residual volumes
(<inline-formula><mml:math id="M125" display="inline"><mml:mrow><mml:msub><mml:mi>V</mml:mi><mml:mi mathvariant="normal">res</mml:mi></mml:msub></mml:mrow></mml:math></inline-formula>). The 95 % confidence interval for the slope and
intercept of the regression lines was used to calculate the uncertainty on
the calculated residual volumes. Standard errors of the regression residuals
were twice those of the reference measurements. This indicates additional
source(s) of random error, which could include some variability in the
residual volumes and/or nonuniform mixing of the sources between consecutive
samples. Estimates of <inline-formula><mml:math id="M126" display="inline"><mml:mrow><mml:msub><mml:mi>V</mml:mi><mml:mi mathvariant="normal">res</mml:mi></mml:msub></mml:mrow></mml:math></inline-formula> were calculated to vary between 0.28
and 0.46 mL (Table 2). In trials (a) and (c), <inline-formula><mml:math id="M127" display="inline"><mml:mrow><mml:msub><mml:mi>V</mml:mi><mml:mi mathvariant="normal">res</mml:mi></mml:msub></mml:mrow></mml:math></inline-formula> were
statistically different when calculated using [<inline-formula><mml:math id="M128" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">NO</mml:mi><mml:mn mathvariant="normal">3</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula>]<inline-formula><mml:math id="M129" display="inline"><mml:msub><mml:mi/><mml:mi mathvariant="normal">high</mml:mi></mml:msub></mml:math></inline-formula>
and [<inline-formula><mml:math id="M130" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">NO</mml:mi><mml:mn mathvariant="normal">3</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula>]<inline-formula><mml:math id="M131" display="inline"><mml:msub><mml:mi/><mml:mi mathvariant="normal">low</mml:mi></mml:msub></mml:math></inline-formula>, and also differed between trials (a)
and (b) for [<inline-formula><mml:math id="M132" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">NO</mml:mi><mml:mn mathvariant="normal">3</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula>]<inline-formula><mml:math id="M133" display="inline"><mml:msub><mml:mi/><mml:mi mathvariant="normal">low</mml:mi></mml:msub></mml:math></inline-formula>. Practically, our results show that
when using the purging back to source configuration (Fig. 1b) less than
0.5 mL of water (5 % of sample volume pumped) from the previous sample
may contaminate the source measured. This is comparable to previous analysis
of the large volume MPS showing <inline-formula><mml:math id="M134" display="inline"><mml:mrow><mml:msub><mml:mi>V</mml:mi><mml:mi mathvariant="normal">res</mml:mi></mml:msub></mml:mrow></mml:math></inline-formula> of 4 % sample volume
pumped (Birgand et al., 2016). This volume may correspond to droplets left in
the 0.9 mm i.d. tubing.</p>
      <p id="d1e2388">Although this residual volume is significant, its effect depends on the
application. When alternating between 3 and 5 mg <inline-formula><mml:math id="M135" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">NO</mml:mi><mml:mn mathvariant="normal">3</mml:mn></mml:msub><mml:mo>-</mml:mo><mml:mi mathvariant="normal">N</mml:mi></mml:mrow></mml:math></inline-formula> L<inline-formula><mml:math id="M136" display="inline"><mml:msup><mml:mi/><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:msup></mml:math></inline-formula> of
<inline-formula><mml:math id="M137" display="inline"><mml:mrow class="chem"><mml:msubsup><mml:mi mathvariant="normal">NO</mml:mi><mml:mn mathvariant="normal">3</mml:mn><mml:mo>-</mml:mo></mml:msubsup></mml:mrow></mml:math></inline-formula> sources 50 L in volume, it would take 500 purges to source
before a 0.01 mg <inline-formula><mml:math id="M138" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">NO</mml:mi><mml:mn mathvariant="normal">3</mml:mn></mml:msub><mml:mo>-</mml:mo><mml:mi mathvariant="normal">N</mml:mi></mml:mrow></mml:math></inline-formula> L<inline-formula><mml:math id="M139" display="inline"><mml:msup><mml:mi/><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:msup></mml:math></inline-formula> change in the concentration would be
detectable as a result of residuals purged to the alternate source. In the
same situation with a 0.5 L source, only five purges would induce the same
level of change. These results suggest that the purge to source
configuration should be used in short-lived experiments and only in
applications with a high source volume (<inline-formula><mml:math id="M140" display="inline"><mml:mrow><mml:mo>&gt;</mml:mo><mml:mn mathvariant="normal">10</mml:mn></mml:mrow></mml:math></inline-formula> L), which would keep
this artifact undetectable. For small-volume applications (e.g., porewater
sampling) source<?pagebreak page5620?> contamination may be significant and the “purge to waste”
routine is recommended, rather than the purging back to source configuration.</p>

<?xmltex \floatpos{p}?><table-wrap id="Ch1.T3"><caption><p id="d1e2472">Zero-order <inline-formula><mml:math id="M141" display="inline"><mml:mrow class="chem"><mml:msubsup><mml:mi mathvariant="normal">NO</mml:mi><mml:mn mathvariant="normal">3</mml:mn><mml:mo>-</mml:mo></mml:msubsup></mml:mrow></mml:math></inline-formula> removal rates, <inline-formula><mml:math id="M142" display="inline"><mml:mi>k</mml:mi></mml:math></inline-formula>, at eight well
locations during five experimental trials. The zero-order kinetics model was
fitted to time series of <inline-formula><mml:math id="M143" display="inline"><mml:mrow class="chem"><mml:msubsup><mml:mi mathvariant="normal">NO</mml:mi><mml:mn mathvariant="normal">3</mml:mn><mml:mo>-</mml:mo></mml:msubsup></mml:mrow></mml:math></inline-formula> concentrations after flow to the lab
bioreactor was stopped. RMSEP refers to the root mean square error of prediction.</p></caption><oasis:table frame="topbot"><oasis:tgroup cols="4">
     <oasis:colspec colnum="1" colname="col1" align="left"/>
     <oasis:colspec colnum="2" colname="col2" align="center"/>
     <oasis:colspec colnum="3" colname="col3" align="center"/>
     <oasis:colspec colnum="4" colname="col4" align="center"/>
     <oasis:thead>
       <oasis:row>
         <oasis:entry colname="col1">Well</oasis:entry>
         <oasis:entry colname="col2">Zero order, <inline-formula><mml:math id="M144" display="inline"><mml:mi>k</mml:mi></mml:math></inline-formula></oasis:entry>
         <oasis:entry colname="col3"><inline-formula><mml:math id="M145" display="inline"><mml:mrow><mml:msup><mml:mi>R</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msup></mml:mrow></mml:math></inline-formula></oasis:entry>
         <oasis:entry colname="col4">RMSEP</oasis:entry>
       </oasis:row>
       <oasis:row rowsep="1">
         <oasis:entry colname="col1">location</oasis:entry>
         <oasis:entry colname="col2">(mg L<inline-formula><mml:math id="M146" display="inline"><mml:mrow><mml:msup><mml:mi/><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:msup><mml:mspace linebreak="nobreak" width="0.125em"/><mml:msup><mml:mi>h</mml:mi><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:msup></mml:mrow></mml:math></inline-formula>)</oasis:entry>
         <oasis:entry colname="col3"/>
         <oasis:entry colname="col4">(mg L<inline-formula><mml:math id="M147" display="inline"><mml:mrow><mml:msup><mml:mi/><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:msup><mml:mspace width="0.125em" linebreak="nobreak"/><mml:msup><mml:mi>h</mml:mi><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:msup></mml:mrow></mml:math></inline-formula>)</oasis:entry>
       </oasis:row>
     </oasis:thead>
     <oasis:tbody>
       <oasis:row>
         <oasis:entry colname="col1">D1</oasis:entry>
         <oasis:entry colname="col2">0.25–0.43</oasis:entry>
         <oasis:entry colname="col3">0.96–0.99</oasis:entry>
         <oasis:entry colname="col4">0.002–0.003</oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1">D2</oasis:entry>
         <oasis:entry colname="col2">0.27–0.43</oasis:entry>
         <oasis:entry colname="col3">0.94–0.99</oasis:entry>
         <oasis:entry colname="col4">0.002–0.005</oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1">D3</oasis:entry>
         <oasis:entry colname="col2">0.29–0.38</oasis:entry>
         <oasis:entry colname="col3">0.84–0.99</oasis:entry>
         <oasis:entry colname="col4">0.002–0.010</oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1">D4</oasis:entry>
         <oasis:entry colname="col2">0.30–0.38</oasis:entry>
         <oasis:entry colname="col3">0.93–0.99</oasis:entry>
         <oasis:entry colname="col4">0.001–0.008</oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1">S1</oasis:entry>
         <oasis:entry colname="col2">0.30–0.44</oasis:entry>
         <oasis:entry colname="col3">0.93–0.99</oasis:entry>
         <oasis:entry colname="col4">0.002–0.008</oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1">S2</oasis:entry>
         <oasis:entry colname="col2">0.30–0.54</oasis:entry>
         <oasis:entry colname="col3">0.97–0.99</oasis:entry>
         <oasis:entry colname="col4">0.002–0.006</oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1">S3</oasis:entry>
         <oasis:entry colname="col2">0.15–0.34</oasis:entry>
         <oasis:entry colname="col3">0.88–0.98</oasis:entry>
         <oasis:entry colname="col4">0.003–0.006</oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1">S4</oasis:entry>
         <oasis:entry colname="col2">0.13–0.36</oasis:entry>
         <oasis:entry colname="col3">0.91–0.99</oasis:entry>
         <oasis:entry colname="col4">0.001–0.010</oasis:entry>
       </oasis:row>
     </oasis:tbody>
   </oasis:tgroup></oasis:table></table-wrap>

</sec>
<sec id="Ch1.S2.SS3.SSS3">
  <title>Pump time requirement results</title>
      <?pagebreak page5621?><p id="d1e2743">Times required for a single sampling sequence (pumping and purging from
source) for variable tube lengths were not linear with tubing length (data not
shown), and best described using the following equation: <inline-formula><mml:math id="M148" display="inline"><mml:mrow><mml:mtext>time</mml:mtext><mml:mo>=</mml:mo><mml:mn mathvariant="normal">0.0001</mml:mn><mml:mo>×</mml:mo><mml:msup><mml:mtext>length</mml:mtext><mml:mn mathvariant="normal">2</mml:mn></mml:msup><mml:mo>+</mml:mo><mml:mn mathvariant="normal">0.0662</mml:mn><mml:mo>×</mml:mo><mml:mtext>length</mml:mtext><mml:mo>+</mml:mo><mml:mn mathvariant="normal">79.4</mml:mn></mml:mrow></mml:math></inline-formula>, where time corresponds to the cumulative time
in seconds required to pump and purge from the source to the cuvette, and
length is the tube length from the source to the MPS in centimeters. From this
equation, the time for a sampling sequence between consecutive sources was
calculated with 60 s added to account for cuvette rinsing for the
spectrophotometer measurement time. For applications with sources up to 1, 4,
and 9 m away from the MPS, the time for one sample sequence would be 147, 182,
and 280 s, respectively. The results suggest that roughly 30 min resolution
water quality data can be obtained for up to 10 sources with sources up to
4 m away. The resolution would fall to 47 min for the same number of
sources up to 9 m away.</p>
</sec>
</sec>
</sec>
<sec id="Ch1.S3">
  <title>Frequent porewater sampling in a woodchip bioreactor</title>
      <p id="d1e2785">Woodchip bioreactors, also called denitrification beds, are a popular
agricultural conservation practice for the treatment of <inline-formula><mml:math id="M149" display="inline"><mml:mrow class="chem"><mml:msubsup><mml:mi mathvariant="normal">NO</mml:mi><mml:mn mathvariant="normal">3</mml:mn><mml:mo>-</mml:mo></mml:msubsup></mml:mrow></mml:math></inline-formula> in
subsurface drainage. These anaerobic systems provide woodchips as a carbon
source and promote denitrification to remove <inline-formula><mml:math id="M150" display="inline"><mml:mrow class="chem"><mml:msubsup><mml:mi mathvariant="normal">NO</mml:mi><mml:mn mathvariant="normal">3</mml:mn><mml:mo>-</mml:mo></mml:msubsup></mml:mrow></mml:math></inline-formula> from the aquatic
environment. Soil pits typically <inline-formula><mml:math id="M151" display="inline"><mml:mrow><mml:mo>∼</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:math></inline-formula> m deep, <inline-formula><mml:math id="M152" display="inline"><mml:mrow><mml:mo>∼</mml:mo><mml:mn mathvariant="normal">5</mml:mn></mml:mrow></mml:math></inline-formula> m wide, and <inline-formula><mml:math id="M153" display="inline"><mml:mrow><mml:mo>∼</mml:mo><mml:mn mathvariant="normal">25</mml:mn></mml:mrow></mml:math></inline-formula> m long are filled with woodchips through which drainage water
percolates. Over 20 years of research on woodchip bioreactors has shown their
potential to reduce <inline-formula><mml:math id="M154" display="inline"><mml:mrow class="chem"><mml:msubsup><mml:mi mathvariant="normal">NO</mml:mi><mml:mn mathvariant="normal">3</mml:mn><mml:mo>-</mml:mo></mml:msubsup></mml:mrow></mml:math></inline-formula> concentrations, but has also shown
troubling variability in reported treatment efficacy (e.g., 81 % to
3 %; David et al., 2016) or bioreactor volumetric removal rates (e.g., 2
to 22 g N m<inline-formula><mml:math id="M155" display="inline"><mml:msup><mml:mi/><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">3</mml:mn></mml:mrow></mml:msup></mml:math></inline-formula> d<inline-formula><mml:math id="M156" display="inline"><mml:msup><mml:mi/><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:msup></mml:math></inline-formula>, reviewed by Schipper et al., 2010; 0.42 to
7.76 g N m<inline-formula><mml:math id="M157" display="inline"><mml:msup><mml:mi/><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">3</mml:mn></mml:mrow></mml:msup></mml:math></inline-formula> d<inline-formula><mml:math id="M158" display="inline"><mml:msup><mml:mi/><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:msup></mml:math></inline-formula>, Christianson et al., 2012). Variation in
treatment performance has been attributed to various factors, including
hydraulic residence time (HRT), temperature, influent concentration, and age
(Addy et al., 2016; Hoover et al., 2016). An important part of
the reported uncertainty and variability seems to be associated with
measurement methods ill-suited to quantify <inline-formula><mml:math id="M159" display="inline"><mml:mrow class="chem"><mml:msubsup><mml:mi mathvariant="normal">NO</mml:mi><mml:mn mathvariant="normal">3</mml:mn><mml:mo>-</mml:mo></mml:msubsup></mml:mrow></mml:math></inline-formula> fluxes into,
within, and leaving bioreactors. Woodchip bioreactors are mostly treated as
“black box” systems.</p>
      <p id="d1e2919">There is evidence that internal hydraulic flow paths and short-circuiting may
result in overall treatment inefficiencies, although this has been inferred
indirectly in field and lab experiments using tracers (Christianson et
al., 2013; Cameron and Schipper, 2011; Hoover et al., 2016). We report
results from a preliminary experiment showing that the small-volume MPS can
help improve understanding of bioreactors as black box systems.</p>
<sec id="Ch1.S3.SS1">
  <title>Materials and methods</title>
      <p id="d1e2927">Nitrate dynamics were studied in a (<inline-formula><mml:math id="M160" display="inline"><mml:mrow><mml:mn mathvariant="normal">1.20</mml:mn><mml:mo>×</mml:mo><mml:mn mathvariant="normal">1.20</mml:mn><mml:mo>×</mml:mo><mml:mn mathvariant="normal">0.45</mml:mn></mml:mrow></mml:math></inline-formula> m deep) lab
bioreactor at North Carolina State University using the small-volume MPS
(Figs. S2 and S3 in the Supplement). This bioreactor is a lab-scale model of
field bioreactors in which inlet and outlet manifolds installed at opposite
corners create diagonal flow from the inlet at the top to the outlet at the
bottom (Fig. S2). Eight sampling wells within the bioreactor woodchip media
were monitored for <inline-formula><mml:math id="M161" display="inline"><mml:mrow class="chem"><mml:msubsup><mml:mi mathvariant="normal">NO</mml:mi><mml:mn mathvariant="normal">3</mml:mn><mml:mo>-</mml:mo></mml:msubsup></mml:mrow></mml:math></inline-formula> concentrations using the small-volume MPS.
Sample wells were placed at shallow (<inline-formula><mml:math id="M162" display="inline"><mml:mi>S</mml:mi></mml:math></inline-formula>) or deep (<inline-formula><mml:math id="M163" display="inline"><mml:mi>D</mml:mi></mml:math></inline-formula>) zones (20.9 and
41.9 cm depth, respectively) and at 55.9 and 100.2 cm from the inlet along
two longitudinal transects. Transects were located along the centerline and
21.6 cm from the left sidewall (Fig. S2). Wells were made of stainless steel
tubing (0.32 cm O.D.) with vertical slits cut at the tip to draw water into
the well. Wells tips were covered with fine plankton netting
(60 <inline-formula><mml:math id="M164" display="inline"><mml:mrow><mml:mi mathvariant="normal">µ</mml:mi><mml:mi mathvariant="normal">m</mml:mi></mml:mrow></mml:math></inline-formula> mesh) to prevent clogging of MPS tubing. Well names were
assigned based on their location in the bioreactor. Wells S1 and S2 were
shallow wells located near the inlet on the centerline and 21.6 cm from the
sidewall, respectively. Wells S3 and S4 were shallow wells located near the
outlet on the centerline and 21.6 cm from the sidewall, respectively. The
same convention was used for deep wells D1–D4.</p>
      <p id="d1e2983">For these experiments a dual sampling–analyzing system was used. The small-volume MPS did not directly sample water from each well. Instead, to obtain
synchronized <inline-formula><mml:math id="M165" display="inline"><mml:mrow class="chem"><mml:msubsup><mml:mi mathvariant="normal">NO</mml:mi><mml:mn mathvariant="normal">3</mml:mn><mml:mo>-</mml:mo></mml:msubsup></mml:mrow></mml:math></inline-formula> concentrations in the bioreactor, all wells were
sampled simultaneously using an eight-channel ISMATEC peristaltic pump triggered
by the MPS Arduino board. The eight-channel pump simultaneously delivered sample
volumes from each well to an intermediate manifold of eight 40 mL syringes.
The small-volume MPS was then used to sequentially pump water to the cuvette
for analysis by the spectrophotometer. The probe was calibrated for
<inline-formula><mml:math id="M166" display="inline"><mml:mrow class="chem"><mml:msubsup><mml:mi mathvariant="normal">NO</mml:mi><mml:mn mathvariant="normal">3</mml:mn><mml:mo>-</mml:mo></mml:msubsup></mml:mrow></mml:math></inline-formula> using PLSR techniques described previously (Etheridge et al., 2014).</p>

      <?xmltex \floatpos{t}?><fig id="Ch1.F3" specific-use="star"><caption><p id="d1e3014">Nitrate concentration at inlet and wells near the inlet before and
during the <inline-formula><mml:math id="M167" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">KNO</mml:mi><mml:mn mathvariant="normal">3</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> injection. Color indicates bioreactor inlet and depth
of sampling wells, and shape indicates the position of the well transect
(centerline or near the side wall).</p></caption>
          <?xmltex \igopts{width=312.980315pt}?><graphic xlink:href="https://hess.copernicus.org/articles/22/5615/2018/hess-22-5615-2018-f03.png"/>

        </fig>

</sec>
<sec id="Ch1.S3.SS2">
  <title>Small-volume MPS reveals short-circuiting inside a woodchip bioreactor</title>
      <p id="d1e3040">In the first MPS application, we conducted a 76 h constant <inline-formula><mml:math id="M168" display="inline"><mml:mrow class="chem"><mml:msubsup><mml:mi mathvariant="normal">NO</mml:mi><mml:mn mathvariant="normal">3</mml:mn><mml:mo>-</mml:mo></mml:msubsup></mml:mrow></mml:math></inline-formula>
injection experiment from 30 April to 4 May 2015 in a saturated bioreactor
receiving 60 L h<inline-formula><mml:math id="M169" display="inline"><mml:msup><mml:mi/><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:msup></mml:math></inline-formula> tap water flow for a theoretical HRT of <inline-formula><mml:math id="M170" display="inline"><mml:mrow><mml:mo>∼</mml:mo><mml:mn mathvariant="normal">5.7</mml:mn></mml:mrow></mml:math></inline-formula> h. Nitrate from a concentrated <inline-formula><mml:math id="M171" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">KNO</mml:mi><mml:mn mathvariant="normal">3</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> stock solution was injected
using a precision piston pump (Fluid Metering Inc. Model QBG,
1.2 g L<inline-formula><mml:math id="M172" display="inline"><mml:msup><mml:mi/><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:msup></mml:math></inline-formula>) for a target inflow <inline-formula><mml:math id="M173" display="inline"><mml:mrow class="chem"><mml:msubsup><mml:mi mathvariant="normal">NO</mml:mi><mml:mn mathvariant="normal">3</mml:mn><mml:mo>-</mml:mo></mml:msubsup></mml:mrow></mml:math></inline-formula> concentration of
20 mg <inline-formula><mml:math id="M174" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">NO</mml:mi><mml:mn mathvariant="normal">3</mml:mn></mml:msub><mml:mo>-</mml:mo><mml:mi mathvariant="normal">N</mml:mi></mml:mrow></mml:math></inline-formula> L<inline-formula><mml:math id="M175" display="inline"><mml:msup><mml:mi/><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:msup></mml:math></inline-formula>. The eight wells were sampled and analyzed
every 40 min with the system described in Sect. 3.1. Ports 9 and 10 of the
12-port valve directly sampled the inlet and outlet weirs after consecutively
analyzing sample volumes from each of the eight wells. In the first
experiment, <inline-formula><mml:math id="M176" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">KNO</mml:mi><mml:mn mathvariant="normal">3</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> injection began at 08:10 on 1 May (14.2 h after
MPS monitoring began, Fig. 3). From 14.2 to 22.4 h <inline-formula><mml:math id="M177" display="inline"><mml:mrow class="chem"><mml:msubsup><mml:mi mathvariant="normal">NO</mml:mi><mml:mn mathvariant="normal">3</mml:mn><mml:mo>-</mml:mo></mml:msubsup></mml:mrow></mml:math></inline-formula>
concentrations were stable around 18.3 mg <inline-formula><mml:math id="M178" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">NO</mml:mi><mml:mn mathvariant="normal">3</mml:mn></mml:msub><mml:mo>-</mml:mo><mml:mi mathvariant="normal">N</mml:mi></mml:mrow></mml:math></inline-formula> L<inline-formula><mml:math id="M179" display="inline"><mml:msup><mml:mi/><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:msup></mml:math></inline-formula>. After
this period, inlet concentrations rose until 37 h and were variable over the
76 h injection. Inlet <inline-formula><mml:math id="M180" display="inline"><mml:mrow class="chem"><mml:msubsup><mml:mi mathvariant="normal">NO</mml:mi><mml:mn mathvariant="normal">3</mml:mn><mml:mo>-</mml:mo></mml:msubsup></mml:mrow></mml:math></inline-formula> concentration ranged from 18.2 to
20.6 mg <inline-formula><mml:math id="M181" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">NO</mml:mi><mml:mn mathvariant="normal">3</mml:mn></mml:msub><mml:mo>-</mml:mo><mml:mi mathvariant="normal">N</mml:mi></mml:mrow></mml:math></inline-formula> L<inline-formula><mml:math id="M182" display="inline"><mml:msup><mml:mi/><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:msup></mml:math></inline-formula> and varied by 12 % of the target
inlet concentration. Variability in inlet <inline-formula><mml:math id="M183" display="inline"><mml:mrow class="chem"><mml:msubsup><mml:mi mathvariant="normal">NO</mml:mi><mml:mn mathvariant="normal">3</mml:mn><mml:mo>-</mml:mo></mml:msubsup></mml:mrow></mml:math></inline-formula> concentration was
higher than anticipated due to degassing in the <inline-formula><mml:math id="M184" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">KNO</mml:mi><mml:mn mathvariant="normal">3</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> solution tank,
with accumulation of air bubbles partially restricting flow through the piston
pump.</p>
      <p id="d1e3258">Nitrate concentrations at the inlet rose quickly to
18.4 mg <inline-formula><mml:math id="M185" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">NO</mml:mi><mml:mn mathvariant="normal">3</mml:mn></mml:msub><mml:mo>-</mml:mo><mml:mi mathvariant="normal">N</mml:mi></mml:mrow></mml:math></inline-formula> L<inline-formula><mml:math id="M186" display="inline"><mml:msup><mml:mi/><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:msup></mml:math></inline-formula> within 47 min of starting the <inline-formula><mml:math id="M187" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">KNO</mml:mi><mml:mn mathvariant="normal">3</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula>
injection (Fig. 3). Inlet <inline-formula><mml:math id="M188" display="inline"><mml:mrow class="chem"><mml:msubsup><mml:mi mathvariant="normal">NO</mml:mi><mml:mn mathvariant="normal">3</mml:mn><mml:mo>-</mml:mo></mml:msubsup></mml:mrow></mml:math></inline-formula> concentration likely passed
18 mg <inline-formula><mml:math id="M189" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">NO</mml:mi><mml:mn mathvariant="normal">3</mml:mn></mml:msub><mml:mo>-</mml:mo><mml:mi mathvariant="normal">N</mml:mi></mml:mrow></mml:math></inline-formula> L<inline-formula><mml:math id="M190" display="inline"><mml:msup><mml:mi/><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:msup></mml:math></inline-formula> sooner, but the sampling time resolution of
47 min was insufficient to capture the exact time of the<?pagebreak page5622?> arrival. Three of
the four wells nearest the inlet (S1, D1, and D2) showed nearly identical
increases in <inline-formula><mml:math id="M191" display="inline"><mml:mrow class="chem"><mml:msubsup><mml:mi mathvariant="normal">NO</mml:mi><mml:mn mathvariant="normal">3</mml:mn><mml:mo>-</mml:mo></mml:msubsup></mml:mrow></mml:math></inline-formula>, with concentrations at these wells passing
18 mg <inline-formula><mml:math id="M192" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">NO</mml:mi><mml:mn mathvariant="normal">3</mml:mn></mml:msub><mml:mo>-</mml:mo><mml:mi mathvariant="normal">N</mml:mi></mml:mrow></mml:math></inline-formula> L<inline-formula><mml:math id="M193" display="inline"><mml:msup><mml:mi/><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:msup></mml:math></inline-formula> within 4.5–8.2 h of the injection. The
shallow inlet well located along the side wall (S2) showed a noticeable lag,
with <inline-formula><mml:math id="M194" display="inline"><mml:mrow class="chem"><mml:msubsup><mml:mi mathvariant="normal">NO</mml:mi><mml:mn mathvariant="normal">3</mml:mn><mml:mo>-</mml:mo></mml:msubsup></mml:mrow></mml:math></inline-formula> staying below 18 mg <inline-formula><mml:math id="M195" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">NO</mml:mi><mml:mn mathvariant="normal">3</mml:mn></mml:msub><mml:mo>-</mml:mo><mml:mi mathvariant="normal">N</mml:mi></mml:mrow></mml:math></inline-formula> L<inline-formula><mml:math id="M196" display="inline"><mml:msup><mml:mi/><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:msup></mml:math></inline-formula> until
19.7 h after the injection began. Nitrate concentrations at this well were
significantly lower over the entire injection, relative to other wells near
the inlet. All four inlet wells showed increases and decreases in
<inline-formula><mml:math id="M197" display="inline"><mml:mrow class="chem"><mml:msubsup><mml:mi mathvariant="normal">NO</mml:mi><mml:mn mathvariant="normal">3</mml:mn><mml:mo>-</mml:mo></mml:msubsup></mml:mrow></mml:math></inline-formula> concentrations that corresponded to changes in concentration
at the inlet, although variability at S2 was much higher than the other three
inlet wells. Nitrate concentrations in deep wells near the inlet closely
followed one another during each sample interval, with an average difference
of only 0.13 mg <inline-formula><mml:math id="M198" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">NO</mml:mi><mml:mn mathvariant="normal">3</mml:mn></mml:msub><mml:mo>-</mml:mo><mml:mi mathvariant="normal">N</mml:mi></mml:mrow></mml:math></inline-formula> L<inline-formula><mml:math id="M199" display="inline"><mml:msup><mml:mi/><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:msup></mml:math></inline-formula>. Shallow wells near the inlet
varied greatly, with an average difference of
2.04 mg <inline-formula><mml:math id="M200" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">NO</mml:mi><mml:mn mathvariant="normal">3</mml:mn></mml:msub><mml:mo>-</mml:mo><mml:mi mathvariant="normal">N</mml:mi></mml:mrow></mml:math></inline-formula> L<inline-formula><mml:math id="M201" display="inline"><mml:msup><mml:mi/><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:msup></mml:math></inline-formula>.</p>
      <p id="d1e3488">A period of 4 h after injection, <inline-formula><mml:math id="M202" display="inline"><mml:mrow class="chem"><mml:msubsup><mml:mi mathvariant="normal">NO</mml:mi><mml:mn mathvariant="normal">3</mml:mn><mml:mo>-</mml:mo></mml:msubsup></mml:mrow></mml:math></inline-formula> was detected at the deep middle
well near the outlet (D3), but outlet <inline-formula><mml:math id="M203" display="inline"><mml:mrow class="chem"><mml:msubsup><mml:mi mathvariant="normal">NO</mml:mi><mml:mn mathvariant="normal">3</mml:mn><mml:mo>-</mml:mo></mml:msubsup></mml:mrow></mml:math></inline-formula> concentrations did not
become stable until about 25 h, or 5 times the theoretical HRT of 5.7 h. The
very long lag for stabilization of <inline-formula><mml:math id="M204" display="inline"><mml:mrow class="chem"><mml:msubsup><mml:mi mathvariant="normal">NO</mml:mi><mml:mn mathvariant="normal">3</mml:mn><mml:mo>-</mml:mo></mml:msubsup></mml:mrow></mml:math></inline-formula> concentrations at the
outlet weir was likely due to the variability of injected <inline-formula><mml:math id="M205" display="inline"><mml:mrow class="chem"><mml:msubsup><mml:mi mathvariant="normal">NO</mml:mi><mml:mn mathvariant="normal">3</mml:mn><mml:mo>-</mml:mo></mml:msubsup></mml:mrow></mml:math></inline-formula> to
move through the bioreactor, as apparent from the 16.9, 17.5, and 21.2 h
taken for S3, S4, and D3 to reach 18 mg <inline-formula><mml:math id="M206" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">NO</mml:mi><mml:mn mathvariant="normal">3</mml:mn></mml:msub><mml:mo>-</mml:mo><mml:mi mathvariant="normal">N</mml:mi></mml:mrow></mml:math></inline-formula> L<inline-formula><mml:math id="M207" display="inline"><mml:msup><mml:mi/><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:msup></mml:math></inline-formula>.</p>
      <p id="d1e3571">Nitrate concentrations were significantly greater in deep wells relative to
shallow wells at side wells near the inlet and at middle wells near the
outlet. Shallow wells had higher <inline-formula><mml:math id="M208" display="inline"><mml:mrow class="chem"><mml:msubsup><mml:mi mathvariant="normal">NO</mml:mi><mml:mn mathvariant="normal">3</mml:mn><mml:mo>-</mml:mo></mml:msubsup></mml:mrow></mml:math></inline-formula> concentration at side
outlet wells and middle inlet wells. Variance in <inline-formula><mml:math id="M209" display="inline"><mml:mrow class="chem"><mml:msubsup><mml:mi mathvariant="normal">NO</mml:mi><mml:mn mathvariant="normal">3</mml:mn><mml:mo>-</mml:mo></mml:msubsup></mml:mrow></mml:math></inline-formula>
concentration was higher in shallow wells than deep wells at all four well
pairs, illustrating that water moved quickly diagonally through the
bioreactor and short-circuited most of the bioreactor volume. Lag and lower
<inline-formula><mml:math id="M210" display="inline"><mml:mrow class="chem"><mml:msubsup><mml:mi mathvariant="normal">NO</mml:mi><mml:mn mathvariant="normal">3</mml:mn><mml:mo>-</mml:mo></mml:msubsup></mml:mrow></mml:math></inline-formula> concentrations observed in the shallow wells (e.g., S2 and
S4; Fig. 4) suggest that areas further away from the direct diagonal
flow path may have slower hydraulic exchange and higher HRT (e.g., S2) and
act as “dead zones”.</p>

      <?xmltex \floatpos{t}?><fig id="Ch1.F4" specific-use="star"><caption><p id="d1e3616">Nitrate concentration at outlet and wells near the outlet before and
during the <inline-formula><mml:math id="M211" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">KNO</mml:mi><mml:mn mathvariant="normal">3</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> injection. Color indicates bioreactor outlet and
depth of sampling wells, and shape indicates the position of the well transect
(centerline or near the side wall).</p></caption>
          <?xmltex \igopts{width=312.980315pt}?><graphic xlink:href="https://hess.copernicus.org/articles/22/5615/2018/hess-22-5615-2018-f04.png"/>

        </fig>

      <p id="d1e3636">To the best of our knowledge, short-circuiting and dead zones have never been
observed directly but only inferred through dispersion indices
(Morrill Dispersion Index) shown in field reactors (Christianson
et al., 2013) and in lab reactors (Hoover et al., 2016). Delayed time of
arrival for <inline-formula><mml:math id="M212" display="inline"><mml:mrow class="chem"><mml:msubsup><mml:mi mathvariant="normal">NO</mml:mi><mml:mn mathvariant="normal">3</mml:mn><mml:mo>-</mml:mo></mml:msubsup></mml:mrow></mml:math></inline-formula> at wells farther from the shortest flow path
indicates hydraulic inefficiencies; however several shallow wells also showed
cyclic patterns in <inline-formula><mml:math id="M213" display="inline"><mml:mrow class="chem"><mml:msubsup><mml:mi mathvariant="normal">NO</mml:mi><mml:mn mathvariant="normal">3</mml:mn><mml:mo>-</mml:mo></mml:msubsup></mml:mrow></mml:math></inline-formula> concentrations. Microbial and gas clogging
has been documented and can be caused by the creation of biofilm pore walls
by microbial cells or fungi (Oberdorfer and Peterson, 1985; Okubo and
Matsumoto, 1979; Vandevivere et al., 1995) or by extracellular polymers (Shaw
et al., 1985; Vandevivere and Baveye, 1992). Gas clogging<?pagebreak page5623?> due to the
accumulation of microbial-produced gas bubbles and influencing hydraulic
conductivity in peat (Kellner et al., 2004; Beckwith and Baird, 2001) seems
to explain some observed transient low conductivity (Kellner et al., 2004).
These changes in hydraulic conductivity could explain the <inline-formula><mml:math id="M214" display="inline"><mml:mrow class="chem"><mml:msubsup><mml:mi mathvariant="normal">NO</mml:mi><mml:mn mathvariant="normal">3</mml:mn><mml:mo>-</mml:mo></mml:msubsup></mml:mrow></mml:math></inline-formula>
concentration fluctuations of the S2, S3, and S4 wells, which exhibited
regular decreases and increases of <inline-formula><mml:math id="M215" display="inline"><mml:mrow class="chem"><mml:msubsup><mml:mi mathvariant="normal">NO</mml:mi><mml:mn mathvariant="normal">3</mml:mn><mml:mo>-</mml:mo></mml:msubsup></mml:mrow></mml:math></inline-formula> concentrations.</p>
</sec>
<sec id="Ch1.S3.SS3">
  <title>Internal nitrate removal kinetics</title>
      <p id="d1e3698">In a second set of bioreactor experiments, <inline-formula><mml:math id="M216" display="inline"><mml:mrow class="chem"><mml:msubsup><mml:mi mathvariant="normal">NO</mml:mi><mml:mn mathvariant="normal">3</mml:mn><mml:mo>-</mml:mo></mml:msubsup></mml:mrow></mml:math></inline-formula> reduction kinetics
were measured at each well. The lab bioreactor was fully drained for a period
of 24 h. Following this drain event, the woodchips were re-saturated with
the same <inline-formula><mml:math id="M217" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">KNO</mml:mi><mml:mn mathvariant="normal">3</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> spiked tap water made by the same method described in
Sect. 3.2. Inflow <inline-formula><mml:math id="M218" display="inline"><mml:mrow class="chem"><mml:msubsup><mml:mi mathvariant="normal">NO</mml:mi><mml:mn mathvariant="normal">3</mml:mn><mml:mo>-</mml:mo></mml:msubsup></mml:mrow></mml:math></inline-formula> concentration was
14 mg <inline-formula><mml:math id="M219" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">NO</mml:mi><mml:mn mathvariant="normal">3</mml:mn></mml:msub><mml:mo>-</mml:mo><mml:mi mathvariant="normal">N</mml:mi></mml:mrow></mml:math></inline-formula> L<inline-formula><mml:math id="M220" display="inline"><mml:msup><mml:mi/><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:msup></mml:math></inline-formula> at 108 L h<inline-formula><mml:math id="M221" display="inline"><mml:msup><mml:mi/><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:msup></mml:math></inline-formula>. After pumping 4.5 pore
volumes through the reactor, flow was stopped and the outlet weir raised to
prevent any outflow. Each well was sampled every 3 h over 24 h during five
trials from 26 March to 12 April using the MPS and eight-channel pump. Times
series of <inline-formula><mml:math id="M222" display="inline"><mml:mrow class="chem"><mml:msubsup><mml:mi mathvariant="normal">NO</mml:mi><mml:mn mathvariant="normal">3</mml:mn><mml:mo>-</mml:mo></mml:msubsup></mml:mrow></mml:math></inline-formula> concentrations at each well were fitted to zero
order kinetics models (Eq. 1). Time series were fitted using the
nls() function in R which calculates least-squares estimates for model parameters.
In fitting the zero-order model, only the concentrations after flow were
stopped and above 2 mg <inline-formula><mml:math id="M223" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">NO</mml:mi><mml:mn mathvariant="normal">3</mml:mn></mml:msub><mml:mo>-</mml:mo><mml:mi mathvariant="normal">N</mml:mi></mml:mrow></mml:math></inline-formula> L<inline-formula><mml:math id="M224" display="inline"><mml:msup><mml:mi/><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:msup></mml:math></inline-formula> were used. Other than both
shallow outlet wells, <inline-formula><mml:math id="M225" display="inline"><mml:mrow class="chem"><mml:msubsup><mml:mi mathvariant="normal">NO</mml:mi><mml:mn mathvariant="normal">3</mml:mn><mml:mo>-</mml:mo></mml:msubsup></mml:mrow></mml:math></inline-formula> concentrations at each well peaked at
12.5–13.5 mg <inline-formula><mml:math id="M226" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">NO</mml:mi><mml:mn mathvariant="normal">3</mml:mn></mml:msub><mml:mo>-</mml:mo><mml:mi mathvariant="normal">N</mml:mi></mml:mrow></mml:math></inline-formula> L<inline-formula><mml:math id="M227" display="inline"><mml:msup><mml:mi/><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:msup></mml:math></inline-formula> after flow was stopped. Both shallow
outlet wells had much lower peaks of
9.5–10.5 mg <inline-formula><mml:math id="M228" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">NO</mml:mi><mml:mn mathvariant="normal">3</mml:mn></mml:msub><mml:mo>-</mml:mo><mml:mi mathvariant="normal">N</mml:mi></mml:mrow></mml:math></inline-formula> L<inline-formula><mml:math id="M229" display="inline"><mml:msup><mml:mi/><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:msup></mml:math></inline-formula>, consistent with observations in the
first experiment that wells in this zone were slower to receive new water.</p>
      <p id="d1e3886">Over the five trials, zero-order <inline-formula><mml:math id="M230" display="inline"><mml:mrow class="chem"><mml:msubsup><mml:mi mathvariant="normal">NO</mml:mi><mml:mn mathvariant="normal">3</mml:mn><mml:mo>-</mml:mo></mml:msubsup></mml:mrow></mml:math></inline-formula> removal rates ranged from 0.13
to 0.54 mg <inline-formula><mml:math id="M231" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">NO</mml:mi><mml:mn mathvariant="normal">3</mml:mn></mml:msub><mml:mo>-</mml:mo><mml:mi mathvariant="normal">N</mml:mi></mml:mrow></mml:math></inline-formula> L<inline-formula><mml:math id="M232" display="inline"><mml:msup><mml:mi/><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:msup></mml:math></inline-formula> h<inline-formula><mml:math id="M233" display="inline"><mml:msup><mml:mi/><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:msup></mml:math></inline-formula> (Table 3). For this
experimental bioreactor with a measured porosity of 0.59, this equates to a
range of 1.84–7.65 g N m<inline-formula><mml:math id="M234" display="inline"><mml:msup><mml:mi/><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">3</mml:mn></mml:mrow></mml:msup></mml:math></inline-formula> d<inline-formula><mml:math id="M235" display="inline"><mml:msup><mml:mi/><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:msup></mml:math></inline-formula> (m<inline-formula><mml:math id="M236" display="inline"><mml:msup><mml:mi/><mml:mn mathvariant="normal">3</mml:mn></mml:msup></mml:math></inline-formula> of reactor volume).
Having access to eight points provided a range of removal rates and
illustrated variability within the bioreactor. Spatial variability in the
volumetric <inline-formula><mml:math id="M237" display="inline"><mml:mrow class="chem"><mml:msubsup><mml:mi mathvariant="normal">NO</mml:mi><mml:mn mathvariant="normal">3</mml:mn><mml:mo>-</mml:mo></mml:msubsup></mml:mrow></mml:math></inline-formula> removal rates approached those reported across many
field bioreactors (reviewed by Schipper et al., 2010). While there was high
variability in <inline-formula><mml:math id="M238" display="inline"><mml:mrow class="chem"><mml:msubsup><mml:mi mathvariant="normal">NO</mml:mi><mml:mn mathvariant="normal">3</mml:mn><mml:mo>-</mml:mo></mml:msubsup></mml:mrow></mml:math></inline-formula> removal rates within trials, there was no
significant difference in mean values between wells when considering all five
trials. The five lowest removal rates measured (Table 3) were in shallow
outlet wells S3 and S4 (observed dead zones), and indicate that there may be
a causality between <inline-formula><mml:math id="M239" display="inline"><mml:mrow class="chem"><mml:msubsup><mml:mi mathvariant="normal">NO</mml:mi><mml:mn mathvariant="normal">3</mml:mn><mml:mo>-</mml:mo></mml:msubsup></mml:mrow></mml:math></inline-formula> removal rates and hydraulic inefficiencies
or clogging.</p>
</sec>
</sec>
<?pagebreak page5624?><sec id="Ch1.S4">
  <title>High-frequency measurements in in situ stream mesocosms</title>
      <p id="d1e4022">Among the many methods used to measure <inline-formula><mml:math id="M240" display="inline"><mml:mrow class="chem"><mml:msubsup><mml:mi mathvariant="normal">NO</mml:mi><mml:mn mathvariant="normal">3</mml:mn><mml:mo>-</mml:mo></mml:msubsup></mml:mrow></mml:math></inline-formula> removal kinetics in
streams, the in situ mesocosm method is attractive as it involves minimal
disturbance of the sediment, is effective for investigating spatial
variability under field conditions, and can be performed at different times
of the year (reviewed by Birgand et al., 2007). In situ mesocosms consist of
open-bottom containers inserted into the sediment which isolate water inside
the mesocosm from the surrounding stream, making it possible to estimate
process kinetics from changes in nutrient concentrations over time. Water
recirculation is often applied to mimic ambient stream velocity.</p>
      <p id="d1e4038">The standard method consists in manual sample withdrawal several times (most
often 4–7 times; reviewed by Birgand et al., 2007) over the duration of the
experiment (typically <inline-formula><mml:math id="M241" display="inline"><mml:mrow><mml:mo>&lt;</mml:mo><mml:mn mathvariant="normal">48</mml:mn></mml:mrow></mml:math></inline-formula> h). In laboratory mesocosms the volume of the
water withdrawn is a minor issue as one can account for the mass of nutrients
removed (e.g., Birgand et al., 2016; Messer et al., 2017). For in situ
mesocosms water withdrawal is more significant as this water will, over time,
be replaced by water upwelling from the sediment porewater. This discourages
taking more samples during the experiment to reduce uncertainty in kinetics
estimates. The inherent conflict between kinetics uncertainties and porewater
interference in in situ stream mesocosms can be solved with the small-volume
MPS used in the purging back to source configuration (Fig. 1b).</p>
<sec id="Ch1.S4.SS1">
  <title>Materials and methods</title>
      <p id="d1e4056">To characterize <inline-formula><mml:math id="M242" display="inline"><mml:mrow class="chem"><mml:msubsup><mml:mi mathvariant="normal">NO</mml:mi><mml:mn mathvariant="normal">3</mml:mn><mml:mo>-</mml:mo></mml:msubsup></mml:mrow></mml:math></inline-formula> removal kinetics of a stream prior to its
restoration (Claridge Nursery, Goldsboro, NC; 35.4<inline-formula><mml:math id="M243" display="inline"><mml:msup><mml:mi/><mml:mo>∘</mml:mo></mml:msup></mml:math></inline-formula> N,
78.0<inline-formula><mml:math id="M244" display="inline"><mml:msup><mml:mi/><mml:mo>∘</mml:mo></mml:msup></mml:math></inline-formula> W), the small-volume MPS was used with in situ mesocosms in
two distinct sections of the reach to be restored. The upper reach of the
ditch (1.6 km) has submerged vegetation and a thick muck sediment
(20–30 cm depth) with high organic content (2 %–26 % organic
matter). The lower reach (0.6 km) has no instream vegetation and sandy
sediment with low organic content (0.1 %–9.0 % organic matter). The
upper and lower reaches are referred to as Muck and Sand, respectively.</p>
      <p id="d1e4090">In 11 24 h experimental trials from August 2014 to March 2015, four
mesocosms made of open-bottom barrels were gently inserted into the
sediment down to approximately 10 cm within a 1 m radius of each other
(Fig. S4). Each 57 cm diameter barrel inserted into the sediment is
referred to as a Sediment mesocosm and covered 0.26 m<inline-formula><mml:math id="M245" display="inline"><mml:msup><mml:mi/><mml:mn mathvariant="normal">2</mml:mn></mml:msup></mml:math></inline-formula> of the stream bottom. A
fifth, closed-bottom barrel (referred to as Control mesocosm) placed in the
stream for temperature adjustment and containing only stream water served as
a control, representing <inline-formula><mml:math id="M246" display="inline"><mml:mrow class="chem"><mml:msubsup><mml:mi mathvariant="normal">NO</mml:mi><mml:mn mathvariant="normal">3</mml:mn><mml:mo>-</mml:mo></mml:msubsup></mml:mrow></mml:math></inline-formula> removal processes occurring in the
water column. Water depth in Sediment mesocosms was measured manually.
Recirculating DC pumps (3 L min<inline-formula><mml:math id="M247" display="inline"><mml:msup><mml:mi/><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:msup></mml:math></inline-formula>) were placed on the sidewall of the
barrel (Fig. S5) and their flow was adjusted to mimic ambient stream velocity
(0.02–0.10 m s<inline-formula><mml:math id="M248" display="inline"><mml:msup><mml:mi/><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:msup></mml:math></inline-formula>). Sample lines were placed near the recirculating
pumps to obtain a well-mixed sample volume. Mesocosms were removed at the end
of each experiment to allow hydrologic connection with the stream between
trials. Four 24 h trials were completed at each Muck site and three trials
performed at the downstream Sand site across four seasons.</p>
      <p id="d1e4139">At the beginning of each trial a 2 L solution of <inline-formula><mml:math id="M249" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">KNO</mml:mi><mml:mn mathvariant="normal">3</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> was added to
each mesocosm to reach an initial <inline-formula><mml:math id="M250" display="inline"><mml:mrow class="chem"><mml:msubsup><mml:mi mathvariant="normal">NO</mml:mi><mml:mn mathvariant="normal">3</mml:mn><mml:mo>-</mml:mo></mml:msubsup></mml:mrow></mml:math></inline-formula> concentration of
5–6 mg <inline-formula><mml:math id="M251" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">NO</mml:mi><mml:mn mathvariant="normal">3</mml:mn></mml:msub><mml:mo>-</mml:mo><mml:mi mathvariant="normal">N</mml:mi></mml:mrow></mml:math></inline-formula> L<inline-formula><mml:math id="M252" display="inline"><mml:msup><mml:mi/><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:msup></mml:math></inline-formula>. The overlying water was gently stirred and
left to equilibrate. The addition of the <inline-formula><mml:math id="M253" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">KNO</mml:mi><mml:mn mathvariant="normal">3</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> solution generating
extra head inside the mesocosm helped prevent upwelling from groundwater
(Solder et al., 2015) which might have otherwise occurred. Each sample volume
pumped by the MPS temporarily withdrew <inline-formula><mml:math id="M254" display="inline"><mml:mrow><mml:mo>∼</mml:mo><mml:mn mathvariant="normal">25</mml:mn></mml:mrow></mml:math></inline-formula> mL of sample over <inline-formula><mml:math id="M255" display="inline"><mml:mrow><mml:mo>&lt;</mml:mo><mml:mn mathvariant="normal">4</mml:mn></mml:mrow></mml:math></inline-formula> min, corresponding to <inline-formula><mml:math id="M256" display="inline"><mml:mrow><mml:mo>&gt;</mml:mo><mml:mn mathvariant="normal">0.1</mml:mn></mml:mrow></mml:math></inline-formula> mm drop in head, which we assumed was not
high or long enough to generate significant upwelling.</p>
      <p id="d1e4235">Mesocosms were sampled every 36 min for 24 h using the small-volume MPS.
The measurement cuvette (1.1 mL, 4 mm path length) was rinsed with <inline-formula><mml:math id="M257" display="inline"><mml:mrow><mml:mo>&gt;</mml:mo><mml:mn mathvariant="normal">10</mml:mn><mml:mo>×</mml:mo><mml:msub><mml:mi>V</mml:mi><mml:mi mathvariant="normal">res</mml:mi></mml:msub></mml:mrow></mml:math></inline-formula> to prevent cross-contamination. Zero-order,
first-order, and efficiency loss (EL) kinetics models accounting for water
depth (<inline-formula><mml:math id="M258" display="inline"><mml:mi>D</mml:mi></mml:math></inline-formula>) (Eq. 1–3)
were fitted to the <inline-formula><mml:math id="M259" display="inline"><mml:mrow class="chem"><mml:msubsup><mml:mi mathvariant="normal">NO</mml:mi><mml:mn mathvariant="normal">3</mml:mn><mml:mo>-</mml:mo></mml:msubsup></mml:mrow></mml:math></inline-formula> concentration time series (<inline-formula><mml:math id="M260" display="inline"><mml:mrow><mml:mo>∼</mml:mo><mml:mn mathvariant="normal">40</mml:mn></mml:mrow></mml:math></inline-formula>–50
data points per mesocosm per trial) to (1) compare <inline-formula><mml:math id="M261" display="inline"><mml:mrow class="chem"><mml:msubsup><mml:mi mathvariant="normal">NO</mml:mi><mml:mn mathvariant="normal">3</mml:mn><mml:mo>-</mml:mo></mml:msubsup></mml:mrow></mml:math></inline-formula> removal
rates between sites and across seasons and (2) determine which model best
predicted the observed data.

                <disp-formula specific-use="align" content-type="numbered"><mml:math id="M262" display="block"><mml:mtable displaystyle="true"><mml:mlabeledtr id="Ch1.E1"><mml:mtd/><mml:mtd><mml:mstyle displaystyle="true" class="stylechange"/></mml:mtd><mml:mtd><mml:mrow><mml:mstyle class="stylechange" displaystyle="true"/><mml:msub><mml:mi>C</mml:mi><mml:mi>t</mml:mi></mml:msub><mml:mo>=</mml:mo><mml:msub><mml:mi>C</mml:mi><mml:mn mathvariant="normal">0</mml:mn></mml:msub><mml:mo>-</mml:mo><mml:mstyle displaystyle="true"><mml:mfrac style="display"><mml:mrow><mml:msub><mml:mi mathvariant="italic">ρ</mml:mi><mml:mi mathvariant="normal">zo</mml:mi></mml:msub></mml:mrow><mml:mi>D</mml:mi></mml:mfrac></mml:mstyle><mml:mo>⋅</mml:mo><mml:mi>t</mml:mi></mml:mrow></mml:mtd></mml:mlabeledtr><mml:mlabeledtr id="Ch1.E2"><mml:mtd/><mml:mtd><mml:mstyle displaystyle="true" class="stylechange"/></mml:mtd><mml:mtd><mml:mrow><mml:mstyle class="stylechange" displaystyle="true"/><mml:msub><mml:mi>C</mml:mi><mml:mi>t</mml:mi></mml:msub><mml:mo>=</mml:mo><mml:msub><mml:mi>C</mml:mi><mml:mn mathvariant="normal">0</mml:mn></mml:msub><mml:mo>⋅</mml:mo><mml:msup><mml:mi>e</mml:mi><mml:mrow><mml:mo>-</mml:mo><mml:mfenced close=")" open="("><mml:mrow><mml:mfrac><mml:mrow><mml:msub><mml:mi mathvariant="italic">ρ</mml:mi><mml:mi mathvariant="normal">FO</mml:mi></mml:msub></mml:mrow><mml:mi>D</mml:mi></mml:mfrac><mml:mo>⋅</mml:mo><mml:mi>t</mml:mi></mml:mrow></mml:mfenced></mml:mrow></mml:msup></mml:mrow></mml:mtd></mml:mlabeledtr><mml:mlabeledtr id="Ch1.E3"><mml:mtd/><mml:mtd><mml:mstyle class="stylechange" displaystyle="true"/></mml:mtd><mml:mtd><mml:mrow><mml:mstyle class="stylechange" displaystyle="true"/><mml:msub><mml:mi>C</mml:mi><mml:mi>t</mml:mi></mml:msub><mml:mo>=</mml:mo><mml:msup><mml:mfenced open="(" close=")"><mml:mrow><mml:mstyle displaystyle="true"><mml:mfrac style="display"><mml:mrow><mml:msubsup><mml:mi mathvariant="italic">ρ</mml:mi><mml:mi mathvariant="normal">EL</mml:mi><mml:mrow><mml:mo>(</mml:mo><mml:mi mathvariant="italic">α</mml:mi><mml:mo>-</mml:mo><mml:mn mathvariant="normal">1</mml:mn><mml:mo>)</mml:mo></mml:mrow></mml:msubsup></mml:mrow><mml:mi>D</mml:mi></mml:mfrac></mml:mstyle><mml:mo>⋅</mml:mo><mml:mi>t</mml:mi><mml:mo>+</mml:mo><mml:msubsup><mml:mi>C</mml:mi><mml:mn mathvariant="normal">0</mml:mn><mml:mrow><mml:mfenced open="(" close=")"><mml:mrow><mml:mn mathvariant="normal">1</mml:mn><mml:mo>-</mml:mo><mml:mi mathvariant="italic">α</mml:mi></mml:mrow></mml:mfenced></mml:mrow></mml:msubsup></mml:mrow></mml:mfenced><mml:mrow><mml:mfenced open="(" close=")"><mml:mfrac><mml:mn mathvariant="normal">1</mml:mn><mml:mrow><mml:mn mathvariant="normal">1</mml:mn><mml:mo>-</mml:mo><mml:mi mathvariant="italic">α</mml:mi></mml:mrow></mml:mfrac></mml:mfenced></mml:mrow></mml:msup></mml:mrow></mml:mtd></mml:mlabeledtr></mml:mtable></mml:math></disp-formula>

            Methods of model fitting and evaluation were the same as those presented in
Sect. 3.3 (Messer et al., 2017; Birgand et al., 2016). The
nls() package in R Studio was used to fit observed data to a
model predicting <inline-formula><mml:math id="M263" display="inline"><mml:mrow class="chem"><mml:msubsup><mml:mi mathvariant="normal">NO</mml:mi><mml:mn mathvariant="normal">3</mml:mn><mml:mo>-</mml:mo></mml:msubsup></mml:mrow></mml:math></inline-formula> concentration at time <inline-formula><mml:math id="M264" display="inline"><mml:mi>t</mml:mi></mml:math></inline-formula>, <inline-formula><mml:math id="M265" display="inline"><mml:mrow><mml:msub><mml:mi>C</mml:mi><mml:mi>t</mml:mi></mml:msub></mml:mrow></mml:math></inline-formula>, from
estimates of initial concentration, <inline-formula><mml:math id="M266" display="inline"><mml:mrow><mml:msub><mml:mi>C</mml:mi><mml:mn mathvariant="normal">0</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula>, depth-compensated removal constants (<inline-formula><mml:math id="M267" display="inline"><mml:mrow><mml:msub><mml:mi mathvariant="italic">ρ</mml:mi><mml:mi mathvariant="normal">ZO</mml:mi></mml:msub></mml:mrow></mml:math></inline-formula>, <inline-formula><mml:math id="M268" display="inline"><mml:mrow><mml:msub><mml:mi mathvariant="italic">ρ</mml:mi><mml:mi mathvariant="normal">FO</mml:mi></mml:msub></mml:mrow></mml:math></inline-formula>,
<inline-formula><mml:math id="M269" display="inline"><mml:mrow><mml:msub><mml:mi mathvariant="italic">ρ</mml:mi><mml:mi mathvariant="normal">EL</mml:mi></mml:msub></mml:mrow></mml:math></inline-formula>), and the efficiency loss constant <inline-formula><mml:math id="M270" display="inline"><mml:mi mathvariant="italic">α</mml:mi></mml:math></inline-formula>. The commonly
reported rate constant, <inline-formula><mml:math id="M271" display="inline"><mml:mi>k</mml:mi></mml:math></inline-formula>, was calculated by dividing <inline-formula><mml:math id="M272" display="inline"><mml:mi mathvariant="italic">ρ</mml:mi></mml:math></inline-formula> coefficients
by depth, <inline-formula><mml:math id="M273" display="inline"><mml:mi>D</mml:mi></mml:math></inline-formula>.</p>

<?xmltex \floatpos{t}?><table-wrap id="Ch1.T4" specific-use="star"><caption><p id="d1e4560">Time series of <inline-formula><mml:math id="M274" display="inline"><mml:mrow class="chem"><mml:msubsup><mml:mi mathvariant="normal">NO</mml:mi><mml:mn mathvariant="normal">3</mml:mn><mml:mo>-</mml:mo></mml:msubsup></mml:mrow></mml:math></inline-formula> concentrations in Sediment mesocosms
were fitted to zero- and first-order kinetics models. Results indicate that
for this short-duration experiment (<inline-formula><mml:math id="M275" display="inline"><mml:mrow><mml:mo>&lt;</mml:mo><mml:mn mathvariant="normal">24</mml:mn></mml:mrow></mml:math></inline-formula> h) and at the observed range of
<inline-formula><mml:math id="M276" display="inline"><mml:mrow class="chem"><mml:msubsup><mml:mi mathvariant="normal">NO</mml:mi><mml:mn mathvariant="normal">3</mml:mn><mml:mo>-</mml:mo></mml:msubsup></mml:mrow></mml:math></inline-formula> concentrations (2–6 mg <inline-formula><mml:math id="M277" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">NO</mml:mi><mml:mn mathvariant="normal">3</mml:mn></mml:msub><mml:mo>-</mml:mo><mml:mi mathvariant="normal">N</mml:mi></mml:mrow></mml:math></inline-formula> L<inline-formula><mml:math id="M278" display="inline"><mml:msup><mml:mi/><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:msup></mml:math></inline-formula>), removal
was described equally well by either model, although first-order kinetics
better fitted <inline-formula><mml:math id="M279" display="inline"><mml:mrow class="chem"><mml:msubsup><mml:mi mathvariant="normal">NO</mml:mi><mml:mn mathvariant="normal">3</mml:mn><mml:mo>-</mml:mo></mml:msubsup></mml:mrow></mml:math></inline-formula> time series during trials with large changes in
<inline-formula><mml:math id="M280" display="inline"><mml:mrow class="chem"><mml:msubsup><mml:mi mathvariant="normal">NO</mml:mi><mml:mn mathvariant="normal">3</mml:mn><mml:mo>-</mml:mo></mml:msubsup></mml:mrow></mml:math></inline-formula> concentration. RMSEP refers to the root mean square error of prediction.</p></caption><oasis:table frame="topbot"><oasis:tgroup cols="7">
     <oasis:colspec colnum="1" colname="col1" align="left"/>
     <oasis:colspec colnum="2" colname="col2" align="right"/>
     <oasis:colspec colnum="3" colname="col3" align="right"/>
     <oasis:colspec colnum="4" colname="col4" align="center"/>
     <oasis:colspec colnum="5" colname="col5" align="center"/>
     <oasis:colspec colnum="6" colname="col6" align="right"/>
     <oasis:colspec colnum="7" colname="col7" align="center"/>
     <oasis:thead>
       <oasis:row>
         <oasis:entry colname="col1">Trial date</oasis:entry>
         <oasis:entry colname="col2">Zero order, <inline-formula><mml:math id="M281" display="inline"><mml:mi>k</mml:mi></mml:math></inline-formula></oasis:entry>
         <oasis:entry colname="col3"><inline-formula><mml:math id="M282" display="inline"><mml:mrow><mml:msup><mml:mi>R</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msup></mml:mrow></mml:math></inline-formula></oasis:entry>
         <oasis:entry colname="col4">RMSEP</oasis:entry>
         <oasis:entry colname="col5">First order, <inline-formula><mml:math id="M283" display="inline"><mml:mi>k</mml:mi></mml:math></inline-formula></oasis:entry>
         <oasis:entry colname="col6"><inline-formula><mml:math id="M284" display="inline"><mml:mrow><mml:msup><mml:mi>R</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msup></mml:mrow></mml:math></inline-formula></oasis:entry>
         <oasis:entry colname="col7">RMSEP</oasis:entry>
       </oasis:row>
       <oasis:row rowsep="1">
         <oasis:entry colname="col1">(sediment)</oasis:entry>
         <oasis:entry colname="col2">mg <inline-formula><mml:math id="M285" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">NO</mml:mi><mml:mn mathvariant="normal">3</mml:mn></mml:msub><mml:mo>-</mml:mo><mml:mi mathvariant="normal">N</mml:mi></mml:mrow></mml:math></inline-formula> m<inline-formula><mml:math id="M286" display="inline"><mml:msup><mml:mi/><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">2</mml:mn></mml:mrow></mml:msup></mml:math></inline-formula> d<inline-formula><mml:math id="M287" display="inline"><mml:msup><mml:mi/><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:msup></mml:math></inline-formula></oasis:entry>
         <oasis:entry colname="col3"/>
         <oasis:entry colname="col4">mg <inline-formula><mml:math id="M288" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">NO</mml:mi><mml:mn mathvariant="normal">3</mml:mn></mml:msub><mml:mo>-</mml:mo><mml:mi mathvariant="normal">N</mml:mi></mml:mrow></mml:math></inline-formula> m<inline-formula><mml:math id="M289" display="inline"><mml:msup><mml:mi/><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">2</mml:mn></mml:mrow></mml:msup></mml:math></inline-formula> d<inline-formula><mml:math id="M290" display="inline"><mml:msup><mml:mi/><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:msup></mml:math></inline-formula></oasis:entry>
         <oasis:entry colname="col5">m d<inline-formula><mml:math id="M291" display="inline"><mml:msup><mml:mi/><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:msup></mml:math></inline-formula></oasis:entry>
         <oasis:entry colname="col6"/>
         <oasis:entry colname="col7">m d<inline-formula><mml:math id="M292" display="inline"><mml:msup><mml:mi/><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:msup></mml:math></inline-formula></oasis:entry>
       </oasis:row>
     </oasis:thead>
     <oasis:tbody>
       <oasis:row>
         <oasis:entry colname="col1">28 Aug (Muck)</oasis:entry>
         <oasis:entry colname="col2">500–580</oasis:entry>
         <oasis:entry colname="col3">0.99</oasis:entry>
         <oasis:entry colname="col4">30–60</oasis:entry>
         <oasis:entry colname="col5">0.15–0.17</oasis:entry>
         <oasis:entry colname="col6">0.99</oasis:entry>
         <oasis:entry colname="col7">0.02–0.05</oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1">1O Oct (Muck)</oasis:entry>
         <oasis:entry colname="col2">200–250</oasis:entry>
         <oasis:entry colname="col3">0.95–0.98</oasis:entry>
         <oasis:entry colname="col4">30–60</oasis:entry>
         <oasis:entry colname="col5">0.06–0.07</oasis:entry>
         <oasis:entry colname="col6">0.95–0.98</oasis:entry>
         <oasis:entry colname="col7">0.03–0.05</oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1">6 Nov (Muck)</oasis:entry>
         <oasis:entry colname="col2">140–260</oasis:entry>
         <oasis:entry colname="col3">0.93–0.98</oasis:entry>
         <oasis:entry colname="col4">40–70</oasis:entry>
         <oasis:entry colname="col5">0.04–0.07</oasis:entry>
         <oasis:entry colname="col6">0.93–0.98</oasis:entry>
         <oasis:entry colname="col7">0.03–0.06</oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1">13 Nov (Muck)</oasis:entry>
         <oasis:entry colname="col2">160–200</oasis:entry>
         <oasis:entry colname="col3">0.89–0.98</oasis:entry>
         <oasis:entry colname="col4">20–60</oasis:entry>
         <oasis:entry colname="col5">0.05–0.06</oasis:entry>
         <oasis:entry colname="col6">0.89–0.98</oasis:entry>
         <oasis:entry colname="col7">0.02–0.06</oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1">29 Jan (Muck)</oasis:entry>
         <oasis:entry colname="col2"><inline-formula><mml:math id="M293" display="inline"><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">40</mml:mn></mml:mrow></mml:math></inline-formula>–180</oasis:entry>
         <oasis:entry colname="col3">0.00–0.93</oasis:entry>
         <oasis:entry colname="col4">10–40</oasis:entry>
         <oasis:entry colname="col5">0.00–0.05</oasis:entry>
         <oasis:entry colname="col6">0.00–0.93</oasis:entry>
         <oasis:entry colname="col7">0.00–0.04</oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1">3 Feb (Muck)</oasis:entry>
         <oasis:entry colname="col2">40–120</oasis:entry>
         <oasis:entry colname="col3">0.76–0.99</oasis:entry>
         <oasis:entry colname="col4">20–30</oasis:entry>
         <oasis:entry colname="col5">0.01–0.04</oasis:entry>
         <oasis:entry colname="col6">0.76–0.99</oasis:entry>
         <oasis:entry colname="col7">0.02–0.03</oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1">11 Mar (Muck)</oasis:entry>
         <oasis:entry colname="col2">180–320</oasis:entry>
         <oasis:entry colname="col3">0.93–0.99</oasis:entry>
         <oasis:entry colname="col4">20–40</oasis:entry>
         <oasis:entry colname="col5">0.04–0.09</oasis:entry>
         <oasis:entry colname="col6">0.92–0.99</oasis:entry>
         <oasis:entry colname="col7">0.02–0.04</oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1">18 Mar (Muck)</oasis:entry>
         <oasis:entry colname="col2">90–300</oasis:entry>
         <oasis:entry colname="col3">0.97–0.99</oasis:entry>
         <oasis:entry colname="col4">20–60</oasis:entry>
         <oasis:entry colname="col5">0.03–0.13</oasis:entry>
         <oasis:entry colname="col6">0.97–0.99</oasis:entry>
         <oasis:entry colname="col7">0.02–0.05</oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1">18 Sep (Sand)</oasis:entry>
         <oasis:entry colname="col2">10–110</oasis:entry>
         <oasis:entry colname="col3">0.10–0.86</oasis:entry>
         <oasis:entry colname="col4">20–50</oasis:entry>
         <oasis:entry colname="col5">0.00–0.03</oasis:entry>
         <oasis:entry colname="col6">0.10–0.85</oasis:entry>
         <oasis:entry colname="col7">0.02–0.05</oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1">17 Dec (Sand)</oasis:entry>
         <oasis:entry colname="col2">140–240</oasis:entry>
         <oasis:entry colname="col3">0.97–0.98</oasis:entry>
         <oasis:entry colname="col4">20–30</oasis:entry>
         <oasis:entry colname="col5">0.03–0.06</oasis:entry>
         <oasis:entry colname="col6">0.96–0.98</oasis:entry>
         <oasis:entry colname="col7">0.02–0.03</oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1">16 Mar (Sand)</oasis:entry>
         <oasis:entry colname="col2">20–50</oasis:entry>
         <oasis:entry colname="col3">0.63–0.84</oasis:entry>
         <oasis:entry colname="col4">20–30</oasis:entry>
         <oasis:entry colname="col5">0.01–0.02</oasis:entry>
         <oasis:entry colname="col6">0.63–0.86</oasis:entry>
         <oasis:entry colname="col7">0.02–0.03</oasis:entry>
       </oasis:row>
     </oasis:tbody>
   </oasis:tgroup></oasis:table></table-wrap>

</sec>
<sec id="Ch1.S4.SS2">
  <title>Nitrate uptake kinetics</title>
      <p id="d1e5146">There was little preference between zero- and first-order models in the time
series of decreasing <inline-formula><mml:math id="M294" display="inline"><mml:mrow class="chem"><mml:msubsup><mml:mi mathvariant="normal">NO</mml:mi><mml:mn mathvariant="normal">3</mml:mn><mml:mo>-</mml:mo></mml:msubsup></mml:mrow></mml:math></inline-formula> concentrations (Table 4), with <inline-formula><mml:math id="M295" display="inline"><mml:mrow><mml:msup><mml:mi>R</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msup></mml:mrow></mml:math></inline-formula>
values for both models typically <inline-formula><mml:math id="M296" display="inline"><mml:mrow><mml:mo>&gt;</mml:mo><mml:mn mathvariant="normal">0.95</mml:mn></mml:mrow></mml:math></inline-formula>. Residuals of both models were nearly identical in most cases and differences in model R2 were generally
<inline-formula><mml:math id="M297" display="inline"><mml:mrow><mml:mo>&gt;</mml:mo><mml:mn mathvariant="normal">0.01</mml:mn></mml:mrow></mml:math></inline-formula>. All time series of decreasing <inline-formula><mml:math id="M298" display="inline"><mml:mrow class="chem"><mml:msubsup><mml:mi mathvariant="normal">NO</mml:mi><mml:mn mathvariant="normal">3</mml:mn><mml:mo>-</mml:mo></mml:msubsup></mml:mrow></mml:math></inline-formula> concentrations from
Sand trials showed better fit for zero-order kinetics. Higher <inline-formula><mml:math id="M299" display="inline"><mml:mrow><mml:msup><mml:mi>R</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msup></mml:mrow></mml:math></inline-formula> and
improved residuals for a first-order model, relative<?pagebreak page5625?> to a zero-order model,
were seen in trials with greater decreases in <inline-formula><mml:math id="M300" display="inline"><mml:mrow class="chem"><mml:msubsup><mml:mi mathvariant="normal">NO</mml:mi><mml:mn mathvariant="normal">3</mml:mn><mml:mo>-</mml:mo></mml:msubsup></mml:mrow></mml:math></inline-formula> concentrations
over the experiment. This was the case in 18 March and 28 August trials
during which net <inline-formula><mml:math id="M301" display="inline"><mml:mrow class="chem"><mml:msubsup><mml:mi mathvariant="normal">NO</mml:mi><mml:mn mathvariant="normal">3</mml:mn><mml:mo>-</mml:mo></mml:msubsup></mml:mrow></mml:math></inline-formula> reduction in several mesocosms approached
2–3 mg <inline-formula><mml:math id="M302" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">NO</mml:mi><mml:mn mathvariant="normal">3</mml:mn></mml:msub><mml:mo>-</mml:mo><mml:mi mathvariant="normal">N</mml:mi></mml:mrow></mml:math></inline-formula> L<inline-formula><mml:math id="M303" display="inline"><mml:msup><mml:mi/><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:msup></mml:math></inline-formula> over 24 h. The poorest model fitting
occurred when fitting models to time series with little to no reduction in
<inline-formula><mml:math id="M304" display="inline"><mml:mrow class="chem"><mml:msubsup><mml:mi mathvariant="normal">NO</mml:mi><mml:mn mathvariant="normal">3</mml:mn><mml:mo>-</mml:mo></mml:msubsup></mml:mrow></mml:math></inline-formula> concentrations, when total variability of <inline-formula><mml:math id="M305" display="inline"><mml:mrow class="chem"><mml:msubsup><mml:mi mathvariant="normal">NO</mml:mi><mml:mn mathvariant="normal">3</mml:mn><mml:mo>-</mml:mo></mml:msubsup></mml:mrow></mml:math></inline-formula> was
close to the precision of the spectrophotometer or transient, short-term
changes in <inline-formula><mml:math id="M306" display="inline"><mml:mrow class="chem"><mml:msubsup><mml:mi mathvariant="normal">NO</mml:mi><mml:mn mathvariant="normal">3</mml:mn><mml:mo>-</mml:mo></mml:msubsup></mml:mrow></mml:math></inline-formula> were large relative to net reduction. The EL model
was not useful in these short-term experiments.</p>
      <p id="d1e5311">These results are somewhat contradictory to results obtained in lab wetland
mesocosms of similar size, whereby data were not fitted well by a zero-order
model and whereby the EL model performed best (Birgand et al., 2016). It is
possible that the experiments were not of long enough duration for <inline-formula><mml:math id="M307" display="inline"><mml:mrow class="chem"><mml:msubsup><mml:mi mathvariant="normal">NO</mml:mi><mml:mn mathvariant="normal">3</mml:mn><mml:mo>-</mml:mo></mml:msubsup></mml:mrow></mml:math></inline-formula>
concentrations to decrease enough for differences to appear among models, or
for first-order and EL kinetics to be apparent. In these in situ experiments,
the results suggest that <inline-formula><mml:math id="M308" display="inline"><mml:mrow class="chem"><mml:msubsup><mml:mi mathvariant="normal">NO</mml:mi><mml:mn mathvariant="normal">3</mml:mn><mml:mo>-</mml:mo></mml:msubsup></mml:mrow></mml:math></inline-formula> removal kinetics at the diurnal scale
in nutrient-rich streams were adequately predicted by zero-order models. In
Muck trials, <inline-formula><mml:math id="M309" display="inline"><mml:mi mathvariant="italic">ρ</mml:mi></mml:math></inline-formula> values ranged from 10 to
580 mg <inline-formula><mml:math id="M310" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">NO</mml:mi><mml:mn mathvariant="normal">3</mml:mn></mml:msub><mml:mo>-</mml:mo><mml:mi mathvariant="normal">N</mml:mi></mml:mrow></mml:math></inline-formula> m<inline-formula><mml:math id="M311" display="inline"><mml:msup><mml:mi/><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">2</mml:mn></mml:mrow></mml:msup></mml:math></inline-formula>  d<inline-formula><mml:math id="M312" display="inline"><mml:msup><mml:mi/><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:msup></mml:math></inline-formula> (Table 4). Removal rates in
Sand mesocosms were much lower, ranging from 10 to
240 mg <inline-formula><mml:math id="M313" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">NO</mml:mi><mml:mn mathvariant="normal">3</mml:mn></mml:msub><mml:mo>-</mml:mo><mml:mi mathvariant="normal">N</mml:mi></mml:mrow></mml:math></inline-formula> m<inline-formula><mml:math id="M314" display="inline"><mml:msup><mml:mi/><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">2</mml:mn></mml:mrow></mml:msup></mml:math></inline-formula> d<inline-formula><mml:math id="M315" display="inline"><mml:msup><mml:mi/><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:msup></mml:math></inline-formula>. The results show that for
<inline-formula><mml:math id="M316" display="inline"><mml:mrow class="chem"><mml:msubsup><mml:mi mathvariant="normal">NO</mml:mi><mml:mn mathvariant="normal">3</mml:mn><mml:mo>-</mml:mo></mml:msubsup></mml:mrow></mml:math></inline-formula> removal rates less than 300 mg N m<inline-formula><mml:math id="M317" display="inline"><mml:msup><mml:mi/><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">2</mml:mn></mml:mrow></mml:msup></mml:math></inline-formula> L<inline-formula><mml:math id="M318" display="inline"><mml:msup><mml:mi/><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:msup></mml:math></inline-formula>, the
zero-order rate model was sufficient to fit the data, but the first-order
model appeared better for higher <inline-formula><mml:math id="M319" display="inline"><mml:mrow class="chem"><mml:msubsup><mml:mi mathvariant="normal">NO</mml:mi><mml:mn mathvariant="normal">3</mml:mn><mml:mo>-</mml:mo></mml:msubsup></mml:mrow></mml:math></inline-formula> removal rates generally found
in agricultural streams (350 and 1250 mg N m<inline-formula><mml:math id="M320" display="inline"><mml:msup><mml:mi/><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">2</mml:mn></mml:mrow></mml:msup></mml:math></inline-formula> d<inline-formula><mml:math id="M321" display="inline"><mml:msup><mml:mi/><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:msup></mml:math></inline-formula>; Birgand et
al., 2007).</p>
</sec>
<sec id="Ch1.S4.SS3">
  <title>Seasonal and spatial variability</title>
      <p id="d1e5508">In Muck trials <inline-formula><mml:math id="M322" display="inline"><mml:mrow class="chem"><mml:msubsup><mml:mi mathvariant="normal">NO</mml:mi><mml:mn mathvariant="normal">3</mml:mn><mml:mo>-</mml:mo></mml:msubsup></mml:mrow></mml:math></inline-formula> removal rates followed a predictable seasonal
pattern, with removal rates highest in the month of August, decreasing in
October and November trials, lowest during the winter months, and increasing
again during March. This is consistent with observations that the rates of
microbial processes increase with temperature. Nitrate removal rates during
the 18 August trial (25 <inline-formula><mml:math id="M323" display="inline"><mml:msup><mml:mi/><mml:mo>∘</mml:mo></mml:msup></mml:math></inline-formula>C) were 4–14 times greater than those
during 3 February (8 <inline-formula><mml:math id="M324" display="inline"><mml:msup><mml:mi/><mml:mo>∘</mml:mo></mml:msup></mml:math></inline-formula>C) at the same site. The opposite trend was
seen among Sand trials. The 17 December trial with the coldest temperatures
among Sand trials (10 <inline-formula><mml:math id="M325" display="inline"><mml:msup><mml:mi/><mml:mo>∘</mml:mo></mml:msup></mml:math></inline-formula>C) showed the highest <inline-formula><mml:math id="M326" display="inline"><mml:mrow class="chem"><mml:msubsup><mml:mi mathvariant="normal">NO</mml:mi><mml:mn mathvariant="normal">3</mml:mn><mml:mo>-</mml:mo></mml:msubsup></mml:mrow></mml:math></inline-formula> removal
rates. A seasonal influx of available carbon was likely the cause of this
trend. Accumulated leaf packs at the Sand site, included in the 17 December
mesocosms, provided available carbon and substrate for denitrification to
occur. Nitrate removal rates during this trial were even higher than rates in
Muck trials with similar temperature (29 January and 3 Februry).</p>
      <p id="d1e5564">The in situ mesocosm method revealed high variability in <inline-formula><mml:math id="M327" display="inline"><mml:mrow class="chem"><mml:msubsup><mml:mi mathvariant="normal">NO</mml:mi><mml:mn mathvariant="normal">3</mml:mn><mml:mo>-</mml:mo></mml:msubsup></mml:mrow></mml:math></inline-formula>
removal rates within trials, even when mesocosms were within a 1 m radius.
High variability in Muck trials in the month of March was caused by the
presence of emergent vegetation along the stream bank (Fig. S6). In 11 and
18 March trials, mesocosms placed in this near-bank vegetated zone showed
removal rates 48 %–81 % and 74 %–240 % higher than those in
mesocosms placed in the unvegetated stream center, respectively. In the
29 January trial, a single mesocosm showed removal rates 300 %–2500%
higher than the other Sediment mesocosms. Muck trials had a higher degree of
within-trial variability relative to Sand, indicating that sediment
<inline-formula><mml:math id="M328" display="inline"><mml:mrow class="chem"><mml:msubsup><mml:mi mathvariant="normal">NO</mml:mi><mml:mn mathvariant="normal">3</mml:mn><mml:mo>-</mml:mo></mml:msubsup></mml:mrow></mml:math></inline-formula> removal potential at the Sand site was more homogenous.</p>
</sec>
</sec>
<?pagebreak page5626?><sec id="Ch1.S5" sec-type="conclusions">
  <title>Conclusions</title>
      <p id="d1e5600">The first report of the MPS illustrated the ability of this
technology to increase temporal and spatial resolution of water quality data
(Birgand et al., 2016). The small-volume MPS increases the number of
potential applications for this method by significantly decreasing sample
volume. The small-volume MPS minimized the volume of the flow-through
measurement cell (1.1 mL quartz cuvette), contrasting with the 40 mL
flow-through cell used previously. In order to prevent cross-contamination of
samples caused by pumping from different sources, an adequate pre-measurement
rinse with the current sample volume must be used. For the larger volume MPS
this would require pumping roughly 36 times more volume past the flow-through
cell for adequate rinsing. In the stream mesocosms, removing 25 mL of sample
for <inline-formula><mml:math id="M329" display="inline"><mml:mrow><mml:mo>&lt;</mml:mo><mml:mn mathvariant="normal">4</mml:mn></mml:mrow></mml:math></inline-formula> min to measure absorbance resulted in a temporary head drop <inline-formula><mml:math id="M330" display="inline"><mml:mrow><mml:mo>&lt;</mml:mo><mml:mn mathvariant="normal">0.1</mml:mn></mml:mrow></mml:math></inline-formula> mm and minimized sample withdrawal to allow 40–50 <inline-formula><mml:math id="M331" display="inline"><mml:mrow class="chem"><mml:msubsup><mml:mi mathvariant="normal">NO</mml:mi><mml:mn mathvariant="normal">3</mml:mn><mml:mo>-</mml:mo></mml:msubsup></mml:mrow></mml:math></inline-formula>
measurements to be made over 24 h without significantly affecting mesocosm
hydraulics.</p>
      <p id="d1e5636">The small-volume MPS allows continuous multi-point sampling to be extended to
applications for which the sample volume is limited or must be minimized. The most
obvious application is for porewater sampling, for which sample withdrawal rate
should not exceed the rate at which water moves through the medium. Total
volume extracted must also be small to avoid significantly affecting the
observed environment. Drainable porosity in soils is much less than the total
volume of soil, leading to a zone of influence in which the size depends on the
total sample volume extracted and the drainable porosity. For example,
if sampling every 1 or 6 h over 24 h from a soil with a 0.1 drainable
porosity, this zone of influence (assuming 15 mL required sample volume for
the small-volume MPS) would be 3600 and 600 cm<inline-formula><mml:math id="M332" display="inline"><mml:msup><mml:mi/><mml:mn mathvariant="normal">3</mml:mn></mml:msup></mml:math></inline-formula>, respectively. Assuming
this zone is spherical, it would have a diameter of 19 and 10 cm, which is
not insignificant. The sampling interval should be short enough to adequately
capture temporal variation while avoiding excessive water withdrawal to avoid
interdependence between sampling points that are hydraulically connected.
When removal kinetics were measured in the lab bioreactor during stopped
flow, a sample interval of 3 h was used over 24 h. With an observed
drainable porosity of 0.58, the zone of influence at each of the eight points
was 7.3 cm and accounted for 0.4 % of water in the bioreactor. Sampling
wells were no closer than 21 cm, so an assumption of independence between
sampling points was reasonable.</p>
      <p id="d1e5648">For the first time, the small-volume MPS was able to observe short-circuiting
in a woodchip bioreactor, which had been surmised in the literature although
never fully shown. We were also able to measure <inline-formula><mml:math id="M333" display="inline"><mml:mrow class="chem"><mml:msubsup><mml:mi mathvariant="normal">NO</mml:mi><mml:mn mathvariant="normal">3</mml:mn><mml:mo>-</mml:mo></mml:msubsup></mml:mrow></mml:math></inline-formula> removal rates
at multiple locations within the bioreactor. The application of the MPS in
stream mesocosms has allowed the possibility to measure <inline-formula><mml:math id="M334" display="inline"><mml:mrow class="chem"><mml:msubsup><mml:mi mathvariant="normal">NO</mml:mi><mml:mn mathvariant="normal">3</mml:mn><mml:mo>-</mml:mo></mml:msubsup></mml:mrow></mml:math></inline-formula> removal
kinetics in situ in replicated experiments by eliminating potential
contamination by groundwater. The small-volume MPS has high potential for
providing quality data sets for improving new and existing solute transport
models for saturated or partially saturated soils and presents the
possibility of being used in replicated experiments.</p>
      <p id="d1e5677">Due to the small diameter of the fittings and tubing in this system, several
pumping concerns are magnified compared to the large volume MPS. Water
micro-droplets or residuals in the tubing lines are more susceptible to
freezing and caution should be used when deploying this system under freezing
conditions. Valves and tubing are also more susceptible to clogging. In both
applications a plankton net fabric (60 <inline-formula><mml:math id="M335" display="inline"><mml:mrow><mml:mi mathvariant="normal">µ</mml:mi><mml:mi mathvariant="normal">m</mml:mi></mml:mrow></mml:math></inline-formula> mesh) was used and no
clogging occurred, even in the case of the woodchip bioreactor application
with high dissolved organic matter. The small sample volume potentially
limits the number of sondes and sensors to which the MPS can be coupled. The
design of the s::can spectrophotometer allows for such a small-volume
flow-through measurement cell to be used, while other available water quality
sensors typically require much larger sample volumes for which this system
might not be well suited. The volume-limited applications presented include
sampling an overlying water column and porewater in coarse woodchips.
Porewater sampling in fine soils or sediments may be more restrictive and
will result in a larger sphere of influence around the sampling point. While
the minimum volume required for measurement using the MPS is small (<inline-formula><mml:math id="M336" display="inline"><mml:mrow><mml:mo>∼</mml:mo><mml:mn mathvariant="normal">7</mml:mn></mml:mrow></mml:math></inline-formula> mL) and comparable to other small-volume sediment samplers (e.g., Rhizon
in situ samplers; Seeberg-Elverfeldt et al., 2005), bidirectional pumping
from multiple sources by the MPS requires a volume closer to 10–15 mL to
reduce cross-contamination for accurate solute measurement. Sampling of fine
soils with low hydraulic conductivity using the MPS can be aided by the use
of small-diameter sampling wells, similar to those described in Sect. 3.1.</p>
</sec>

      
      </body>
    <back><notes notes-type="dataavailability">

      <p id="d1e5704">All data presented in this paper in Sects. 2.3.1, 2.3.2,
3.1, 3.2, 4.2, and 4.3 are provided in .csv files in an online Zenodo
repository at <ext-link xlink:href="https://doi.org/10.5281/zenodo.1453353" ext-link-type="DOI">10.5281/zenodo.1453353</ext-link> (Maxwell, 2018). The online
repository also includes the R code (R Studio Ver.1.1.442 or greater) used to
generate plots and calculate coefficients for <inline-formula><mml:math id="M337" display="inline"><mml:mrow class="chem"><mml:msubsup><mml:mi mathvariant="normal">NO</mml:mi><mml:mn mathvariant="normal">3</mml:mn><mml:mo>-</mml:mo></mml:msubsup></mml:mrow></mml:math></inline-formula> removal kinetic
equations.</p>
  </notes><app-group>
        <supplementary-material position="anchor"><p id="d1e5723"><bold>The Supplement related to this article is available online at: <inline-supplementary-material xlink:href="https://doi.org/10.5194/hess-22-5615-2018-supplement" xlink:title="pdf">https://doi.org/10.5194/hess-22-5615-2018-supplement</inline-supplementary-material></bold></p></supplementary-material>
        </app-group><notes notes-type="authorcontribution">

      <p id="d1e5729">Direction of research, funding, and initial development of
the small-volume MPS was provided by FB. Early design and prototyping of the
small-volume MPS was provided by BS and KAD, and development of protocols for
testing cross-contamination was contributed to by KAD.</p>
  </notes><notes notes-type="competinginterests">

      <p id="d1e5735">The authors declare that they have no conflict of interest.</p>
  </notes><ack><title>Acknowledgements</title><p id="d1e5741">The authors would like to acknowledge the NCSU BAE Environmental Analysis
Lab for water chemistry analysis. Stream mesocosm research was funded by the
NCDOT under grant agreement 2013-37, and bioreactor porewater sampling
research was funded in part by NIFA USDA grant 2016-67019-25279 and USDA
multistate project S1063. <?xmltex \hack{\newline}?><?xmltex \hack{\newline}?>
Edited by: Matthew Hipsey  <?xmltex \hack{\newline}?>
Reviewed by: two anonymous referees</p></ack><ref-list>
    <title>References</title>

      <ref id="bib1.bib1"><label>1</label><mixed-citation>
Addy, K., Gold, A., Christianson, L., David, M., Schipper, L., and Ratigan,
N.: Denitrifying bioreactors for nitrate removal: A meta-analysis,
J. Environ. Qual., 45, 873–871, 2016.</mixed-citation></ref>
      <ref id="bib1.bib2"><label>2</label><mixed-citation>
Beckwith, C. W. and Baird, A. J.: Effect of biogenic gas bubbles on water
flow through poorly decomposed blanket peat, Water Resour.  Res., 37, 551–558, 2001.</mixed-citation></ref>
      <ref id="bib1.bib3"><label>3</label><mixed-citation>
Birgand, F., Skaggs, R. W., Chescheir, G. M., and Gilliam, J. W.: Nitrogen
removal in streams of agricultural catchments – a literature review, Crit. Rev. Env. Sci. Tec., 37, 381–487,
2007.</mixed-citation></ref>
      <ref id="bib1.bib4"><label>4</label><mixed-citation>
Birgand, F., Aveni-Deforge, K., Smith, B., Maxwell, B., Horstman, M.,
Gerling, A. B., and Carey, C. C.: First report of a novel multiplexer pumping
system coupled to a water quality probe to collect high temporal frequency
in situ water chemistry measurements at multiple sites, Limnol. Oceanogr.-Meth., 14, 767–783, 2016.</mixed-citation></ref>
      <ref id="bib1.bib5"><label>5</label><mixed-citation>
Cameron, S. G. and Schipper, L. A.: Evaluation of passive solar heating and
alternative flow regimes on nitrate removal in denitrification beds,
Ecol. Eng., 37, 1195–1204, 2011.</mixed-citation></ref>
      <ref id="bib1.bib6"><label>6</label><mixed-citation>
Christianson, L., Helmers, M., Bhandari, A., and Moorman, T.: Internal
hydraulics of an agricultural drainage denitrification bioreactor, Ecol.
Eng., 52, 298–307, 2013.</mixed-citation></ref>
      <ref id="bib1.bib7"><label>7</label><mixed-citation>
Christianson, L. E., Bhandari, A., Helmers, M. J., Kult, K. J., Sutphin, T.,
and Wolf, R.: Performance evaluation of four field-scale agricultural
drainage denitrification bioreactors in iowa, T. ASABE, 55, 2163–2174, 2012.</mixed-citation></ref>
      <ref id="bib1.bib8"><label>8</label><mixed-citation>
Crumpton, W. G., Isenhart, T. M., and Mitchell, P. D.: Nitrate and organic N
analyses with second-derivative spectroscopy, Limnol. Oceanogr.,
37, 907–913, 1992.</mixed-citation></ref>
      <ref id="bib1.bib9"><label>9</label><mixed-citation>
David, M. B., Gentry, L. E., Cooke, R. A., and Herbstritt, S. M.: Temperature
and substrate control woodchip bioreactor performance in reducing tile
nitrate loads in east-central illinois, J. Environ. Qual.,
45, 822–829, 2016.</mixed-citation></ref>
      <ref id="bib1.bib10"><label>10</label><mixed-citation>
Dent, C. L. and Grimm, N. B.: Spatial heterogeneity of stream water nutrient
concentrations over successional time, Ecology, 80, 2283–2298, 1999.</mixed-citation></ref>
      <ref id="bib1.bib11"><label>11</label><mixed-citation>
Etheridge, J. R., Birgand, F., Osborne, J. A., Osburn, C. L., Burchell, M.
R., and Irving, J.: Using in situ ultraviolet-visual spectroscopy to measure
nitrogen, carbon, phosphorus, and suspended solids concentrations at a high
frequency in a brackish tidal marsh, Limnol. Oceanogr.-Meth., 12, 10–22,
2014.</mixed-citation></ref>
      <ref id="bib1.bib12"><label>12</label><mixed-citation>
Finch, M. S., Hydes, D. J., Clayson, C. H., Weigl, B., Dakin, J., and
Gwilliam, P.: A low power ultra violet spectrophotometer for measurement of
nitrate in seawater: Introduction, calibration and initial sea trials,
Anal. Chim. Acta, 377, 167–177, 1998.</mixed-citation></ref>
      <ref id="bib1.bib13"><label>13</label><mixed-citation>
Johnson, K. S. and Coletti, L. J.: In situ ultraviolet spectrophotometry for
high resolution and long-term monitoring of nitrate, bromide and bisulfide
in the ocean, Deep-Sea Res. Pt I,
49, 1291–1305, 2002.</mixed-citation></ref>
      <ref id="bib1.bib14"><label>14</label><mixed-citation>
Kahlert, M., Hasselrot, A. T., Hillebrand, H., and Pettersson, K.: Spatial
and temporal variation in the biomass and nutrient status of epilithic algae
in lake erken, sweden, Freshwater Biol., 47, 1191–1215, 2002.</mixed-citation></ref>
      <ref id="bib1.bib15"><label>15</label><mixed-citation>
Kellner, E., Price, J. S., and Waddington, J.: Pressure variations in peat as
a result of gas bubble dynamics, Hydrol. Process., 18,  2599–2605,
2004.</mixed-citation></ref>
      <ref id="bib1.bib16"><label>16</label><mixed-citation>Maxwell, B.: Replication data for : A small volume multiplexed pumping system
for automated, high frequency water chemistry measurements in volume-limited
applications, Zenodo, <ext-link xlink:href="https://doi.org/10.5281/zenodo.1453353" ext-link-type="DOI">10.5281/zenodo.1453353</ext-link>, 2018.</mixed-citation></ref>
      <ref id="bib1.bib17"><label>17</label><mixed-citation>
McClain, M. E., Boyer, E. W., Dent, C. L., Gergel, S. E., Grimm, N. B.,
Groffman, P. M., Hart, S. C., Harvey, J. W., Johnston, C. A., and Mayorga,
E.: Biogeochemical hot spots and hot moments at the interface of terrestrial
and aquatic ecosystems, Ecosystems, 6, 301–312, 2003.</mixed-citation></ref>
      <ref id="bib1.bib18"><label>18</label><mixed-citation>
Merill, L. and Tonjes, D. J.: A review of the hyporheic zone, stream
restoration, and means to enhance denitrification, Crit. Rev.
Env. Sci. Tec., 44, 2337–2379, 2014.</mixed-citation></ref>
      <ref id="bib1.bib19"><label>19</label><mixed-citation>
Messer, T. L., Burchell II, M. R., Birgand, F., Broome, S. W., and Chescheir,
G.: Nitrate removal potential of restored wetlands loaded with agricultural
drainage water: A mesocosm scale experimental approach, Ecol. Eng., 106,
541–554, 2017.</mixed-citation></ref>
      <ref id="bib1.bib20"><label>20</label><mixed-citation>
Oberdorfer, J. A. and Peterson, F. L.: Waste-water injection: Geochemical
and biogeochemical clogging processes, Groundwater, 23, 753–761, 1985.</mixed-citation></ref>
      <ref id="bib1.bib21"><label>21</label><mixed-citation>
Okubo, T. and Matsumoto, J.: Effect of infiltration rate on biological
clogging and water quality changes during artificial recharge, Water
Resour. Res., 15, 1536–1542, 1979.</mixed-citation></ref>
      <ref id="bib1.bib22"><label>22</label><mixed-citation>
Parkin, T. B.: Soil microsites as a source of denitrification variability,
Soil Sci. Soc. Am. J.,  51,  1194–1199, 1987.</mixed-citation></ref>
      <ref id="bib1.bib23"><label>23</label><mixed-citation>
Rieger, L., Langergraber, G., and Siegrist, H.: Uncertainties of spectral in
situ measurements in wastewater using different calibration approaches,
Water Sci. Technol., 53, 187–197, 2006.</mixed-citation></ref>
      <ref id="bib1.bib24"><label>24</label><mixed-citation>
Rochelle-Newall, E. and Fisher, T.: Chromophoric dissolved organic matter
and dissolved organic carbon in chesapeake bay, Mar.  Chem., 77,
23–41, 2002.</mixed-citation></ref>
      <ref id="bib1.bib25"><label>25</label><mixed-citation>Saraceno, J. F., Pellerin, B. A., Downing, B. D., Boss, E., Bachand, P. A.,
and Bergamaschi, B. A.: High-frequency in situ optical measurements during a
storm event: Assessing relationships between dissolved organic matter,
sediment concentrations, and hydrologic processes, J. Geophys.
Res., 114, G00F09, <ext-link xlink:href="https://doi.org/10.1029/2009JG000989" ext-link-type="DOI">10.1029/2009JG000989</ext-link>, 2009.</mixed-citation></ref>
      <ref id="bib1.bib26"><label>26</label><mixed-citation>
Seeberg-Elverfeldt, J., Schlüter, M., Feseker, T., and Kölling, M.:
Rhizon sampling of porewaters near the sediment-water interface of aquatic
systems, Limnol. Oceanogr.-Meth., 3, 361–371, 2005.</mixed-citation></ref>
      <ref id="bib1.bib27"><label>27</label><mixed-citation>
Schipper, L. A., Robertson, W. D., Gold, A. J., Jaynes, D. B., and Cameron,
S. C.: Denitrifying bioreactors – an approach for reducing nitrate loads to
receiving waters, Ecol. Eng., 36, 1532–1543, 2010.</mixed-citation></ref>
      <ref id="bib1.bib28"><label>28</label><mixed-citation>
Shaw, J. C., Bramhill, B., Wardlaw, N. C., and Costerton, J. W.: Bacterial
fouling in a model core system, Appl. Environ. Microb.,
49, 693–701, 1985.</mixed-citation></ref>
      <?pagebreak page5628?><ref id="bib1.bib29"><label>29</label><mixed-citation>
Solder, J. E., Gilmore, T. E., Genereux, D. P., and Solomon, D. K.: A tube
seepage meter for in situ measurement of seepage rate and groundwater
sampling, Groundwater, 54, 588–595, 2016.</mixed-citation></ref>
      <ref id="bib1.bib30"><label>30</label><mixed-citation>
Suzuki, N. and Kuroda, R.: Direct simultaneous determination of nitrate and
nitrite by ultraviolet second-derivative spectrophotometry, Analyst, 112, 1077–1079, 1987.</mixed-citation></ref>
      <ref id="bib1.bib31"><label>31</label><mixed-citation>Torres, A. and Bertrand-Krajewski, J.-L.: Partial least squares local
calibration of a UV-visible spectrometer used for in situ measurements of cod
and tss concentrations in urban drainage systems, Water Sci. Technol., 57,
581–588, 2008.
 </mixed-citation></ref><?xmltex \hack{\newpage}?>
      <ref id="bib1.bib32"><label>32</label><mixed-citation>
Vandevivere, P. and Baveye, P.: Effect of bacterial extracellular polymers on
the saturated hydraulic conductivity of sand columns, Appl. Environ. Microb.,
58, 1690–1698, 1992.</mixed-citation></ref>
      <ref id="bib1.bib33"><label>33</label><mixed-citation>
Vandevivere, P., Baveye, P., Lozada, D. S., and DeLeo, P.: Microbial clogging
of saturated soils and aquifer materials: Evaluation of mathematical models,
Water Resour. Res., 31, 2173–2180, 1995.</mixed-citation></ref>
      <ref id="bib1.bib34"><label>34</label><mixed-citation>
Vidon, P., Allan, C., Burns, D., Duval, T. P., Gurwick, N., Inamdar, S.,
Lowrance, R., Okay, J., Scott, D., and Sebestyen, S.: Hot spots and hot
moments in riparian zones: Potential for improved water quality management,
J. Am. Water Resour. As., 46, 278–298, 2010.</mixed-citation></ref>

  </ref-list></back>
    <!--<article-title-html>A small-volume multiplexed pumping system for automated, high-frequency water chemistry measurements in volume-limited applications</article-title-html>
<abstract-html><p>An automated multiplexed pumping system (MPS) for high-frequency water
chemistry measurements at multiple locations previously showed the ability to
increase spatial and temporal data resolution and improve understanding of
biogeochemical processes in aquatic environments and at the land–water
interface. The design of the previous system precludes its use in
volume-limited applications in which highly frequent measurements requiring
a large sample volume would significantly affect observed processes. A small-volume MPS was designed to minimize the sample volume while still providing high-frequency data. The system was tested for cross-contamination between
multiple sources, and two applications of the technology are reported. Cross-contamination from multiple sources was shown to be negligible when using
recommended procedures. Short-circuiting of flow in a bioreactor was directly
observed using high-frequency porewater sampling in a well network, and the
small-volume MPS showed high seasonal and spatial variability of nitrate
removal in stream sediments, enhancing data collected from in situ mesocosms.
The results show it is possible to obtain high-frequency data in
volume-limited applications. The technology is most promising at the reach or
transect scale for observing porewater solute dynamics over daily timescales, with data intervals  &lt; 1&thinsp;h for up to 12 locations.</p></abstract-html>
<ref-html id="bib1.bib1"><label>1</label><mixed-citation>
Addy, K., Gold, A., Christianson, L., David, M., Schipper, L., and Ratigan,
N.: Denitrifying bioreactors for nitrate removal: A meta-analysis,
J. Environ. Qual., 45, 873–871, 2016.
</mixed-citation></ref-html>
<ref-html id="bib1.bib2"><label>2</label><mixed-citation>
Beckwith, C. W. and Baird, A. J.: Effect of biogenic gas bubbles on water
flow through poorly decomposed blanket peat, Water Resour.  Res., 37, 551–558, 2001.
</mixed-citation></ref-html>
<ref-html id="bib1.bib3"><label>3</label><mixed-citation>
Birgand, F., Skaggs, R. W., Chescheir, G. M., and Gilliam, J. W.: Nitrogen
removal in streams of agricultural catchments – a literature review, Crit. Rev. Env. Sci. Tec., 37, 381–487,
2007.
</mixed-citation></ref-html>
<ref-html id="bib1.bib4"><label>4</label><mixed-citation>
Birgand, F., Aveni-Deforge, K., Smith, B., Maxwell, B., Horstman, M.,
Gerling, A. B., and Carey, C. C.: First report of a novel multiplexer pumping
system coupled to a water quality probe to collect high temporal frequency
in situ water chemistry measurements at multiple sites, Limnol. Oceanogr.-Meth., 14, 767–783, 2016.
</mixed-citation></ref-html>
<ref-html id="bib1.bib5"><label>5</label><mixed-citation>
Cameron, S. G. and Schipper, L. A.: Evaluation of passive solar heating and
alternative flow regimes on nitrate removal in denitrification beds,
Ecol. Eng., 37, 1195–1204, 2011.
</mixed-citation></ref-html>
<ref-html id="bib1.bib6"><label>6</label><mixed-citation>
Christianson, L., Helmers, M., Bhandari, A., and Moorman, T.: Internal
hydraulics of an agricultural drainage denitrification bioreactor, Ecol.
Eng., 52, 298–307, 2013.
</mixed-citation></ref-html>
<ref-html id="bib1.bib7"><label>7</label><mixed-citation>
Christianson, L. E., Bhandari, A., Helmers, M. J., Kult, K. J., Sutphin, T.,
and Wolf, R.: Performance evaluation of four field-scale agricultural
drainage denitrification bioreactors in iowa, T. ASABE, 55, 2163–2174, 2012.
</mixed-citation></ref-html>
<ref-html id="bib1.bib8"><label>8</label><mixed-citation>
Crumpton, W. G., Isenhart, T. M., and Mitchell, P. D.: Nitrate and organic N
analyses with second-derivative spectroscopy, Limnol. Oceanogr.,
37, 907–913, 1992.
</mixed-citation></ref-html>
<ref-html id="bib1.bib9"><label>9</label><mixed-citation>
David, M. B., Gentry, L. E., Cooke, R. A., and Herbstritt, S. M.: Temperature
and substrate control woodchip bioreactor performance in reducing tile
nitrate loads in east-central illinois, J. Environ. Qual.,
45, 822–829, 2016.
</mixed-citation></ref-html>
<ref-html id="bib1.bib10"><label>10</label><mixed-citation>
Dent, C. L. and Grimm, N. B.: Spatial heterogeneity of stream water nutrient
concentrations over successional time, Ecology, 80, 2283–2298, 1999.
</mixed-citation></ref-html>
<ref-html id="bib1.bib11"><label>11</label><mixed-citation>
Etheridge, J. R., Birgand, F., Osborne, J. A., Osburn, C. L., Burchell, M.
R., and Irving, J.: Using in situ ultraviolet-visual spectroscopy to measure
nitrogen, carbon, phosphorus, and suspended solids concentrations at a high
frequency in a brackish tidal marsh, Limnol. Oceanogr.-Meth., 12, 10–22,
2014.
</mixed-citation></ref-html>
<ref-html id="bib1.bib12"><label>12</label><mixed-citation>
Finch, M. S., Hydes, D. J., Clayson, C. H., Weigl, B., Dakin, J., and
Gwilliam, P.: A low power ultra violet spectrophotometer for measurement of
nitrate in seawater: Introduction, calibration and initial sea trials,
Anal. Chim. Acta, 377, 167–177, 1998.
</mixed-citation></ref-html>
<ref-html id="bib1.bib13"><label>13</label><mixed-citation>
Johnson, K. S. and Coletti, L. J.: In situ ultraviolet spectrophotometry for
high resolution and long-term monitoring of nitrate, bromide and bisulfide
in the ocean, Deep-Sea Res. Pt I,
49, 1291–1305, 2002.
</mixed-citation></ref-html>
<ref-html id="bib1.bib14"><label>14</label><mixed-citation>
Kahlert, M., Hasselrot, A. T., Hillebrand, H., and Pettersson, K.: Spatial
and temporal variation in the biomass and nutrient status of epilithic algae
in lake erken, sweden, Freshwater Biol., 47, 1191–1215, 2002.
</mixed-citation></ref-html>
<ref-html id="bib1.bib15"><label>15</label><mixed-citation>
Kellner, E., Price, J. S., and Waddington, J.: Pressure variations in peat as
a result of gas bubble dynamics, Hydrol. Process., 18,  2599–2605,
2004.
</mixed-citation></ref-html>
<ref-html id="bib1.bib16"><label>16</label><mixed-citation>
Maxwell, B.: Replication data for : A small volume multiplexed pumping system
for automated, high frequency water chemistry measurements in volume-limited
applications, Zenodo, <a href="https://doi.org/10.5281/zenodo.1453353" target="_blank">https://doi.org/10.5281/zenodo.1453353</a>, 2018.
</mixed-citation></ref-html>
<ref-html id="bib1.bib17"><label>17</label><mixed-citation>
McClain, M. E., Boyer, E. W., Dent, C. L., Gergel, S. E., Grimm, N. B.,
Groffman, P. M., Hart, S. C., Harvey, J. W., Johnston, C. A., and Mayorga,
E.: Biogeochemical hot spots and hot moments at the interface of terrestrial
and aquatic ecosystems, Ecosystems, 6, 301–312, 2003.
</mixed-citation></ref-html>
<ref-html id="bib1.bib18"><label>18</label><mixed-citation>
Merill, L. and Tonjes, D. J.: A review of the hyporheic zone, stream
restoration, and means to enhance denitrification, Crit. Rev.
Env. Sci. Tec., 44, 2337–2379, 2014.
</mixed-citation></ref-html>
<ref-html id="bib1.bib19"><label>19</label><mixed-citation>
Messer, T. L., Burchell II, M. R., Birgand, F., Broome, S. W., and Chescheir,
G.: Nitrate removal potential of restored wetlands loaded with agricultural
drainage water: A mesocosm scale experimental approach, Ecol. Eng., 106,
541–554, 2017.
</mixed-citation></ref-html>
<ref-html id="bib1.bib20"><label>20</label><mixed-citation>
Oberdorfer, J. A. and Peterson, F. L.: Waste-water injection: Geochemical
and biogeochemical clogging processes, Groundwater, 23, 753–761, 1985.
</mixed-citation></ref-html>
<ref-html id="bib1.bib21"><label>21</label><mixed-citation>
Okubo, T. and Matsumoto, J.: Effect of infiltration rate on biological
clogging and water quality changes during artificial recharge, Water
Resour. Res., 15, 1536–1542, 1979.
</mixed-citation></ref-html>
<ref-html id="bib1.bib22"><label>22</label><mixed-citation>
Parkin, T. B.: Soil microsites as a source of denitrification variability,
Soil Sci. Soc. Am. J.,  51,  1194–1199, 1987.
</mixed-citation></ref-html>
<ref-html id="bib1.bib23"><label>23</label><mixed-citation>
Rieger, L., Langergraber, G., and Siegrist, H.: Uncertainties of spectral in
situ measurements in wastewater using different calibration approaches,
Water Sci. Technol., 53, 187–197, 2006.
</mixed-citation></ref-html>
<ref-html id="bib1.bib24"><label>24</label><mixed-citation>
Rochelle-Newall, E. and Fisher, T.: Chromophoric dissolved organic matter
and dissolved organic carbon in chesapeake bay, Mar.  Chem., 77,
23–41, 2002.
</mixed-citation></ref-html>
<ref-html id="bib1.bib25"><label>25</label><mixed-citation>
Saraceno, J. F., Pellerin, B. A., Downing, B. D., Boss, E., Bachand, P. A.,
and Bergamaschi, B. A.: High-frequency in situ optical measurements during a
storm event: Assessing relationships between dissolved organic matter,
sediment concentrations, and hydrologic processes, J. Geophys.
Res., 114, G00F09, <a href="https://doi.org/10.1029/2009JG000989" target="_blank">https://doi.org/10.1029/2009JG000989</a>, 2009.
</mixed-citation></ref-html>
<ref-html id="bib1.bib26"><label>26</label><mixed-citation>
Seeberg-Elverfeldt, J., Schlüter, M., Feseker, T., and Kölling, M.:
Rhizon sampling of porewaters near the sediment-water interface of aquatic
systems, Limnol. Oceanogr.-Meth., 3, 361–371, 2005.
</mixed-citation></ref-html>
<ref-html id="bib1.bib27"><label>27</label><mixed-citation>
Schipper, L. A., Robertson, W. D., Gold, A. J., Jaynes, D. B., and Cameron,
S. C.: Denitrifying bioreactors – an approach for reducing nitrate loads to
receiving waters, Ecol. Eng., 36, 1532–1543, 2010.
</mixed-citation></ref-html>
<ref-html id="bib1.bib28"><label>28</label><mixed-citation>
Shaw, J. C., Bramhill, B., Wardlaw, N. C., and Costerton, J. W.: Bacterial
fouling in a model core system, Appl. Environ. Microb.,
49, 693–701, 1985.
</mixed-citation></ref-html>
<ref-html id="bib1.bib29"><label>29</label><mixed-citation>
Solder, J. E., Gilmore, T. E., Genereux, D. P., and Solomon, D. K.: A tube
seepage meter for in situ measurement of seepage rate and groundwater
sampling, Groundwater, 54, 588–595, 2016.
</mixed-citation></ref-html>
<ref-html id="bib1.bib30"><label>30</label><mixed-citation>
Suzuki, N. and Kuroda, R.: Direct simultaneous determination of nitrate and
nitrite by ultraviolet second-derivative spectrophotometry, Analyst, 112, 1077–1079, 1987.
</mixed-citation></ref-html>
<ref-html id="bib1.bib31"><label>31</label><mixed-citation>
Torres, A. and Bertrand-Krajewski, J.-L.: Partial least squares local
calibration of a UV-visible spectrometer used for in situ measurements of cod
and tss concentrations in urban drainage systems, Water Sci. Technol., 57,
581–588, 2008.

</mixed-citation></ref-html>
<ref-html id="bib1.bib32"><label>32</label><mixed-citation>
Vandevivere, P. and Baveye, P.: Effect of bacterial extracellular polymers on
the saturated hydraulic conductivity of sand columns, Appl. Environ. Microb.,
58, 1690–1698, 1992.
</mixed-citation></ref-html>
<ref-html id="bib1.bib33"><label>33</label><mixed-citation>
Vandevivere, P., Baveye, P., Lozada, D. S., and DeLeo, P.: Microbial clogging
of saturated soils and aquifer materials: Evaluation of mathematical models,
Water Resour. Res., 31, 2173–2180, 1995.
</mixed-citation></ref-html>
<ref-html id="bib1.bib34"><label>34</label><mixed-citation>
Vidon, P., Allan, C., Burns, D., Duval, T. P., Gurwick, N., Inamdar, S.,
Lowrance, R., Okay, J., Scott, D., and Sebestyen, S.: Hot spots and hot
moments in riparian zones: Potential for improved water quality management,
J. Am. Water Resour. As., 46, 278–298, 2010.
</mixed-citation></ref-html>--></article>