<?xml version="1.0" encoding="UTF-8"?>
<!DOCTYPE article PUBLIC "-//NLM//DTD Journal Publishing with OASIS Tables v3.0 20080202//EN" "journalpub-oasis3.dtd">
<article xmlns:xlink="http://www.w3.org/1999/xlink" xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:oasis="http://docs.oasis-open.org/ns/oasis-exchange/table" xml:lang="en" dtd-version="3.0">
  <front>
    <journal-meta><journal-id journal-id-type="publisher">HESS</journal-id><journal-title-group>
    <journal-title>Hydrology and Earth System Sciences</journal-title>
    <abbrev-journal-title abbrev-type="publisher">HESS</abbrev-journal-title><abbrev-journal-title abbrev-type="nlm-ta">Hydrol. Earth Syst. Sci.</abbrev-journal-title>
  </journal-title-group><issn pub-type="epub">1607-7938</issn><publisher>
    <publisher-name>Copernicus Publications</publisher-name>
    <publisher-loc>Göttingen, Germany</publisher-loc>
  </publisher></journal-meta>
    <article-meta>
      <article-id pub-id-type="doi">10.5194/hess-22-1491-2018</article-id><title-group><article-title>Effectiveness of distributed temperature measurements for early detection of
piping in river embankments</article-title><alt-title>Effectiveness of distributed temperature measurements</alt-title>
      </title-group><?xmltex \runningtitle{Effectiveness of distributed temperature measurements}?><?xmltex \runningauthor{S. Bersan et al.}?>
      <contrib-group>
        <contrib contrib-type="author" corresp="yes" rid="aff1">
          <name><surname>Bersan</surname><given-names>Silvia</given-names></name>
          <email>bersan.vr@gmail.com</email>
        </contrib>
        <contrib contrib-type="author" corresp="no" rid="aff2">
          <name><surname>Koelewijn</surname><given-names>André R.</given-names></name>
          
        </contrib>
        <contrib contrib-type="author" corresp="no" rid="aff1">
          <name><surname>Simonini</surname><given-names>Paolo</given-names></name>
          
        </contrib>
        <aff id="aff1"><label>1</label><institution>Department of Civil, Environmental and Architectural Engineering,
University of Padova, Padova, 35131, Italy</institution>
        </aff>
        <aff id="aff2"><label>2</label><institution>Department of Dike Technology, Deltares, Delft, 2600 MH, the
Netherlands</institution>
        </aff>
      </contrib-group>
      <author-notes><corresp id="corr1">Silvia Bersan (bersan.vr@gmail.com)</corresp></author-notes><pub-date><day>28</day><month>February</month><year>2018</year></pub-date>
      
      <volume>22</volume>
      <issue>2</issue>
      <fpage>1491</fpage><lpage>1508</lpage>
      <history>
        <date date-type="received"><day>15</day><month>December</month><year>2016</year></date>
           <date date-type="rev-request"><day>9</day><month>January</month><year>2017</year></date>
           <date date-type="rev-recd"><day>18</day><month>December</month><year>2017</year></date>
           <date date-type="accepted"><day>22</day><month>December</month><year>2017</year></date>
      </history>
      <permissions>
        <copyright-statement>Copyright: © 2018 Silvia Bersan et al.</copyright-statement>
        <copyright-year>2018</copyright-year>
      <license license-type="open-access"><license-p>This work is licensed under the Creative Commons Attribution 3.0 Unported License. To view a copy of this licence, visit <ext-link ext-link-type="uri" xlink:href="https://creativecommons.org/licenses/by/3.0/">https://creativecommons.org/licenses/by/3.0/</ext-link></license-p></license></permissions><self-uri xlink:href="https://hess.copernicus.org/articles/22/1491/2018/hess-22-1491-2018.html">This article is available from https://hess.copernicus.org/articles/22/1491/2018/hess-22-1491-2018.html</self-uri><self-uri xlink:href="https://hess.copernicus.org/articles/22/1491/2018/hess-22-1491-2018.pdf">The full text article is available as a PDF file from https://hess.copernicus.org/articles/22/1491/2018/hess-22-1491-2018.pdf</self-uri>
      <abstract><title>Abstract</title>
    <p id="d1e104">Internal erosion is the cause of a significant percentage of failure and
incidents involving both dams and river embankments in many countries. In the
past 20 years the use of fibre-optic Distributed Temperature Sensing (DTS) in
dams has proved to be an effective tool for the detection of leakages and
internal erosion. This work investigates the effectiveness of DTS for dike
monitoring, focusing on the early detection of backward erosion piping, a
mechanism that affects the foundation layer of structures resting on
permeable, sandy soils. The paper presents data from a piping test performed
on a large-scale experimental dike equipped with a DTS system together with a
large number of accompanying sensors. The effect of seepage and piping on the
temperature field is analysed, eventually identifying the processes that
cause the onset of thermal anomalies around piping channels and thus enable
their early detection. Making use of dimensional analysis, the factors that
influence this thermal response of a dike foundation are identified. Finally
some tools are provided that can be helpful for the design of monitoring
systems and for the interpretation of temperature data.</p>
  </abstract>
    </article-meta>
  </front>
<body>
      

<sec id="Ch1.S1" sec-type="intro">
  <label>1</label><title>Introduction</title>
<sec id="Ch1.S1.SS1">
  <label>1.1</label><title>Backward erosion piping</title>
      <p id="d1e123">Backward erosion piping is a specific kind of internal erosion mostly
occurring under water-retaining structures that are founded on fine to medium
sand (ICOLD, 2015). Soil particles are removed and transported by seepage
flow; as a consequence a thin pipe is formed below a roof provided by a layer
of cohesive soil or a rigid structure. The erosion process typically starts
at the downstream side of the structure, where the flow lines converge at an
unfiltered exit (Fig. 1). The erosion channels, or pipes, grow backwards and
when they reach the upstream side a pressure surge can cause an excessive
enlargement, often followed by the failure of the embankment. Backward erosion
piping can also occur, although less frequently, under revetments (Galiana,
2005) or in riverbanks and dike bodies with sandy inclusions (Hagerty, 1991).</p>

      <?xmltex \floatpos{t}?><fig id="Ch1.F1" specific-use="star"><?xmltex \currentcnt{1}?><label>Figure 1</label><caption><p id="d1e128">Backward erosion piping under a dike (adapted from ICOLD, 2015).</p></caption>
          <?xmltex \igopts{width=341.433071pt}?><graphic xlink:href="https://hess.copernicus.org/articles/22/1491/2018/hess-22-1491-2018-f01.pdf"/>

        </fig>

      <p id="d1e137">Backward erosion piping represents a significant problem for the safety of
river and sea dikes<fn id="Ch1.Footn1"><p id="d1e140">Throughout the text mostly <italic>river</italic> dikes
are mentioned, but the statements and findings can also be applied to sea
dikes.</p></fn> located in delta areas, including, for example, the Po Plain in Italy
and a large part of the Netherlands.</p>
      <p id="d1e148">A number of studies have been conducted to describe the piping process and
define failure criteria. The first studies date back to the beginning of the
last century (Clibborn and Beresford, 1902; Bligh, 1910; Terzaghi, 1922) and
still partially form the basis of the rules included in national codes
(USACE, 2005). Many other experimental and theoretical studies followed
across the years (e.g. WES, 1956; De Wit et al., 1981; Weijers and
Sellmeijer, 1993; Muller-Kirchenbauer et al., 1993; Schmertmann, 2000; Ojha
and Singh, 2003; Sellmeijer et al., 2011; Van Beek et al., 2011). Later
studies show that researchers are still investigating the subject to improve
the theoretical model (e.g. Richards and Reddy, 2014; Van Beek et al.,
2014a, b; Allan et al., 2014) and find cost-effective countermeasures
(Koelewijn et al., 2014; Wang et al., 2015).</p>
</sec>
<?pagebreak page1492?><sec id="Ch1.S1.SS2">
  <label>1.2</label><title>Monitoring piping</title>
      <p id="d1e159">Assessing the safety level of existing dikes for piping<fn id="Ch1.Footn2"><p id="d1e162">For the sake
of brevity the term <italic>piping</italic> is used in this paper with the meaning of
backward erosion piping. For indicating internal erosion in general
(including contact erosion, concentrated erosion, suffusion etc.) the term
<italic>internal erosion</italic> is used.</p></fn> is quite challenging because of the
uncertainty associated with the theoretical model and, even more importantly,
the uncertainty related to the spatial variability in the subsoil
composition. The latter is favoured by the large extent of the stretches under assessment and by the geology typical of river
environments. As a matter of fact, ancient riverbeds and crevasse channels
are likely to cross the current course of the rivers, causing a local change
in the type of sediments lying under the dikes. Monitoring systems help in
identifying the zones where stronger seepage is recorded, which often
represents weak spots where failure is more likely to occur. Identification
of the most hazardous stretches along a dike is the first step towards a
rational allocation of the resources for both inspection activities and
improvement works.</p>
      <p id="d1e172">Monitoring systems can also work as early warning tools. In this case their
effectiveness depends on how much in advance they can detect the incipit of
failure in comparison with the time necessary to undertake and complete the
actions aimed at preventing the collapse or to complete the evacuation of
the protected areas. In river embankments, a few sudden failures caused by
piping have been observed (e.g. Imre et al., 2015) but in most cases the
erosion process is slow enough to allow effective intervention, which
consists in building temporary sandbag rings around the sand boils to stop
or slow down the sand transport. The double possibility of either fast or
slow evolution of the mechanism finds confirmation in theory (Van Beek et
al., 2014a) and experiments (Koelewijn and Taccari, 2017).</p>
      <p id="d1e175">Identification of piping is generally performed through visual inspections
during flood events. The main limitations related to this approach are the
lack of qualified personnel and the fact that sand boils can be difficult to
spot. As a matter of fact, they can be hidden by vegetation or by ponding
water at the embankment toe, and they can develop in ditches or hundreds of
metres away from the dike toe. In this context sensors represent “extra
eyes” with the capability of extending the control domain beyond what is
visible and anticipating the detection of anomalies (Peeters et al., 2013).</p>
      <p id="d1e178">Piping is also hard to identify using conventional geotechnical
instrumentation such as pore pressure sensors or inclinometers because its
effect on porewater pressures is highly localized and because often no
significant deformation is produced before the collapse of the structure.
Both theoretical considerations (Ng and Oswalt, 2010) and field data from the
test described here (Bersan, 2015) show that the draining effect of a pipe
affects a region around the pipe with a radius in the order of 1 m.
Consequently, a monitoring system relying on measurements of porewater
pressure would require a high, and therefore uneconomical, number of sensors,
even for controlling short stretches.</p>
      <p id="d1e182">In the last decades, many efforts have been made to identify new parameters
which are linked to seepage and internal erosion and can be measured by means
of extensive technologies. Amongst these are electrical resistivity,
self-potential and temperature (Sheffer et al., 2009). The common shortcoming
of these methods is that they measure quantities that are influenced by a
number of variables besides the occurrence of internal erosion, which makes
data interpretation far from straightforward. As an example, see the
inversion of self-potential data that Rittgers et al. (2015) performed for an
experiment similar to the one described in this paper. Affected by smaller
uncertainties than electrical resistivity and self-potential, the
thermometric method has gained increasing acceptance for the detection of
leakages and internal erosion in the past 2 decades (Johansson and
Sjödahl, 2009).</p>
</sec>
<sec id="Ch1.S1.SS3">
  <label>1.3</label><title>The thermometric method</title>
      <p id="d1e193">The method is based on the principle that, in the absence of seepage (or in
presence of moderate seepage flow), the temperature distribution in the upper
portion of the subsoil fluctuates seasonally in response to the variations of
the air temperature. Daily variations of the air temperature propagate about
1 m below the surface, while annual variations<?pagebreak page1493?> propagate up to 10–15 m
depth. At greater depths the temperature is constant and mildly increases with
depth with an average gradient of 25 <inline-formula><mml:math id="M1" display="inline"><mml:msup><mml:mi/><mml:mo>∘</mml:mo></mml:msup></mml:math></inline-formula>C km<inline-formula><mml:math id="M2" display="inline"><mml:msup><mml:mi/><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:msup></mml:math></inline-formula>. When porewater
flows at significant velocity the transfer of heat promoted by the fluid
flow, denominated <italic>advection</italic>, becomes predominant over the heat
conducted from the surface. Therefore, sections of dam or dike characterized
by markedly different seepage regimes are expected to present different
temperature distributions. Since internal erosion creates zones of higher
permeability and, consequently, a localized increase of the seepage rate, it
is expected to cause a local variation of the temperature field.</p>
      <p id="d1e220">In the past temperature measurements were performed at discrete locations
using thermocouples installed at different depths inside standpipes. After
the introduction of Distributed Temperature Sensing (DTS) systems, it became
possible to perform continuous measurements over kilometres with a spatial
resolution down to 1 m. Optical cables can also be installed along existing
embankments. Easily accessible locations include the landside toe on the landside
slope. Details on the functioning principles of fibre-optic sensors can be
found, for instance, in Henault et al. (2010). There are two variations of
the DTS technique. The passive method, which is the method adopted in this
work, consists in measuring the temperature variations naturally occurring in
the soil. The active method, or heat pulse method, consists in heating the
cable containing the optical fibres and observing how it cools down: higher
seepage flows correspond to a faster cooling.</p>
      <p id="d1e223">To date DTS systems have been installed in concrete dams (in the foundation
soil), earth dams, concrete-face rock-fill (CFRF) dams (to detect leakage
from joints), waterproofed basins and canal dikes (Johansson and
Sjödahl, 2004; Thongthamchart, 2012; Smartec SA, 2017; Courivaud et al.,
2011). Very few installations, however, concern river or sea dikes. The cost
of the data acquisition unit could be one of the factors limiting widespread
use of these sensors. Nevertheless, the diffusion of DTS systems in many
other fields has led to a significant decrease of their costs in the past
decade and a further reduction is expected in the coming years, making the
technique appealing even for applications where the economic investments are
smaller, such as in river management.</p>
      <p id="d1e226">Several studies concerning the influence of internal erosion on the
temperature field of damming structures have been conducted (Johansson, 1997;
Guidoux, 2008; Radzicki and Bonelli, 2010a; Cunat, 2012) and different data
interpretation techniques have been developed. First interpretation
techniques (Claesson et al., 2001) were developed for dams and were suitable
for cases with constant hydraulic loads and sensors located deep enough not
to be influenced by the periodical variations of the external temperature.
Later on, data interpretation tools were designed for cases where the sensor
is located close to the surface so that the temperature recorded is strongly
influenced by the external environment (Radzicki and Bonelli, 2010b; Khan et
al., 2008, 2010).</p>
      <p id="d1e230">The thermometric method has also been extensively exploited to study exchange
fluxes between groundwater and surface water within streams, lakes and
wetlands. Data are collected using couples of thermal loggers installed at
two different depths along the same vertical. One-dimensional analytical solutions are typically used to infer vertical
fluxes from the amplitude ratio or the phase shift of the diurnal temperature
signal between pairs of sensors located at different depth (Irvine et al.,
2017; Briggs et al., 2014). Fibre-optic distributed temperature sensors have
been installed along streambeds and lakebeds to gain information on the
spatial variability of the groundwater–surface water exchange fluxes (Krause
et al., 2012; Tristam et al., 2015). The adoption of distributed temperature
sensors has also been proposed for the quantification of groundwater fluxes;
for this purpose pairs of optical cables must be installed parallel to each
other with a small vertical separation (Becker et al., 2013; Mamer and Lowry,
2013).</p>
</sec>
<sec id="Ch1.S1.SS4">
  <label>1.4</label><title>Aim and objectives</title>
      <p id="d1e241">In this work the effectiveness of DTS to detect backward erosion piping
occurring in the foundation of river and sea dikes is discussed. Although the
use of DTS for early detection of internal erosion is nowadays quite common,
specific studies are advisable to verify the suitability of the technique for
river embankments and to assess what the optimal solutions are in terms of
sensor layout and data analysis. As a matter of fact, there are important
differences between dams and river dikes which influence the thermal response
of the structure and might have an influence on the effectiveness of the
thermometric method. The main differences are the size of the embankment and
the duration of the hydraulic loads, which are nearly constant in dams while they persist
from 12 h to a few days in river and sea dikes.</p>
      <p id="d1e244">This paper illustrates the response of a distributed temperature sensor
installed in a test dike in which piping was induced by gradually increasing
the hydraulic load over a 5-day period. Based on the evidence provided by
the data, different processes that can lead to the onset of thermal anomalies
in regions affected by piping are identified. Making use of the theory of
heat transfer in hydrogeological systems, the conditions required for the
onset of thermal anomalies are discussed. As a result, a conceptual model of
the operation of DTS for piping detection in river dikes is formulated,
which can be helpful for the design of monitoring systems as well as for
basic data interpretation. It could also be the basis for the development of
more complex data interpretation tools.</p>

<?xmltex \floatpos{t}?><table-wrap id="Ch1.T1"><?xmltex \currentcnt{1}?><label>Table 1</label><caption><p id="d1e250">Typical values of soil thermal properties.</p></caption><oasis:table frame="topbot"><?xmltex \begin{scaleboxenv}{.92}[.92]?><oasis:tgroup cols="3">
     <oasis:colspec colnum="1" colname="col1" align="left"/>
     <oasis:colspec colnum="2" colname="col2" align="right"/>
     <oasis:colspec colnum="3" colname="col3" align="right"/>
     <oasis:thead>
       <oasis:row rowsep="1">
         <oasis:entry colname="col1">Parameter</oasis:entry>
         <oasis:entry colname="col2">Value</oasis:entry>
         <oasis:entry colname="col3">Unit</oasis:entry>
       </oasis:row>
     </oasis:thead>
     <oasis:tbody>
       <oasis:row>
         <oasis:entry colname="col1">Thermal conductivity of saturated sand</oasis:entry>
         <oasis:entry colname="col2"><inline-formula><mml:math id="M3" display="inline"><mml:mn mathvariant="normal">2.8</mml:mn></mml:math></inline-formula></oasis:entry>
         <oasis:entry colname="col3">W m<inline-formula><mml:math id="M4" display="inline"><mml:msup><mml:mi/><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:msup></mml:math></inline-formula> K<inline-formula><mml:math id="M5" display="inline"><mml:msup><mml:mi/><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:msup></mml:math></inline-formula></oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1">Thermal conductivity of saturated clay</oasis:entry>
         <oasis:entry colname="col2"><inline-formula><mml:math id="M6" display="inline"><mml:mn mathvariant="normal">1.4</mml:mn></mml:math></inline-formula></oasis:entry>
         <oasis:entry colname="col3">W m<inline-formula><mml:math id="M7" display="inline"><mml:msup><mml:mi/><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:msup></mml:math></inline-formula> K<inline-formula><mml:math id="M8" display="inline"><mml:msup><mml:mi/><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:msup></mml:math></inline-formula></oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1">Thermal conductivity of dry clay</oasis:entry>
         <oasis:entry colname="col2"><inline-formula><mml:math id="M9" display="inline"><mml:mn mathvariant="normal">0.5</mml:mn></mml:math></inline-formula></oasis:entry>
         <oasis:entry colname="col3">W m<inline-formula><mml:math id="M10" display="inline"><mml:msup><mml:mi/><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:msup></mml:math></inline-formula> K<inline-formula><mml:math id="M11" display="inline"><mml:msup><mml:mi/><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:msup></mml:math></inline-formula></oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1">Specific heat capacity of water</oasis:entry>
         <oasis:entry colname="col2"><inline-formula><mml:math id="M12" display="inline"><mml:mn mathvariant="normal">4186</mml:mn></mml:math></inline-formula></oasis:entry>
         <oasis:entry colname="col3">J kg<inline-formula><mml:math id="M13" display="inline"><mml:msup><mml:mi/><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:msup></mml:math></inline-formula> K<inline-formula><mml:math id="M14" display="inline"><mml:msup><mml:mi/><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:msup></mml:math></inline-formula></oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1">Volumetric heat capacity of sat. sand</oasis:entry>
         <oasis:entry colname="col2">2.8 <inline-formula><mml:math id="M15" display="inline"><mml:mo>×</mml:mo></mml:math></inline-formula> <inline-formula><mml:math id="M16" display="inline"><mml:mrow><mml:msup><mml:mn mathvariant="normal">10</mml:mn><mml:mn mathvariant="normal">6</mml:mn></mml:msup></mml:mrow></mml:math></inline-formula></oasis:entry>
         <oasis:entry colname="col3">J m<inline-formula><mml:math id="M17" display="inline"><mml:msup><mml:mi/><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">3</mml:mn></mml:mrow></mml:msup></mml:math></inline-formula> K<inline-formula><mml:math id="M18" display="inline"><mml:msup><mml:mi/><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:msup></mml:math></inline-formula></oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1">Volumetric heat capacity of sat. clay</oasis:entry>
         <oasis:entry colname="col2">2.5 <inline-formula><mml:math id="M19" display="inline"><mml:mo>×</mml:mo></mml:math></inline-formula> <inline-formula><mml:math id="M20" display="inline"><mml:mrow><mml:msup><mml:mn mathvariant="normal">10</mml:mn><mml:mn mathvariant="normal">6</mml:mn></mml:msup></mml:mrow></mml:math></inline-formula></oasis:entry>
         <oasis:entry colname="col3">J m<inline-formula><mml:math id="M21" display="inline"><mml:msup><mml:mi/><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">3</mml:mn></mml:mrow></mml:msup></mml:math></inline-formula> K<inline-formula><mml:math id="M22" display="inline"><mml:msup><mml:mi/><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:msup></mml:math></inline-formula></oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1">Volumetric heat capacity of dry clay</oasis:entry>
         <oasis:entry colname="col2">1.6 <inline-formula><mml:math id="M23" display="inline"><mml:mo>×</mml:mo></mml:math></inline-formula> <inline-formula><mml:math id="M24" display="inline"><mml:mrow><mml:msup><mml:mn mathvariant="normal">10</mml:mn><mml:mn mathvariant="normal">6</mml:mn></mml:msup></mml:mrow></mml:math></inline-formula></oasis:entry>
         <oasis:entry colname="col3">J m<inline-formula><mml:math id="M25" display="inline"><mml:msup><mml:mi/><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">3</mml:mn></mml:mrow></mml:msup></mml:math></inline-formula> K<inline-formula><mml:math id="M26" display="inline"><mml:msup><mml:mi/><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:msup></mml:math></inline-formula></oasis:entry>
       </oasis:row>
     </oasis:tbody>
   </oasis:tgroup><?xmltex \end{scaleboxenv}?></oasis:table></table-wrap>

<?xmltex \hack{\newpage}?>
</sec>
</sec>
<?pagebreak page1494?><sec id="Ch1.S2">
  <label>2</label><title>Theory and methods</title>
<sec id="Ch1.S2.SS1">
  <label>2.1</label><title>Theory of heat transfer in hydrogeological systems</title>
      <p id="d1e617">Heat transfer in porous media is described by the following form of the
advection-diffusion equation:
            <disp-formula id="Ch1.E1" content-type="numbered"><label>1</label><mml:math id="M27" display="block"><mml:mrow><mml:mstyle displaystyle="true"><mml:mfrac style="display"><mml:mrow><mml:mo>∂</mml:mo><mml:mi>T</mml:mi></mml:mrow><mml:mrow><mml:mo>∂</mml:mo><mml:mi>t</mml:mi></mml:mrow></mml:mfrac></mml:mstyle><mml:mo>+</mml:mo><mml:mi mathvariant="normal">∇</mml:mi><mml:mo>⋅</mml:mo><mml:mfenced close=")" open="("><mml:mrow><mml:mstyle displaystyle="true"><mml:mfrac style="display"><mml:mrow><mml:msub><mml:mi mathvariant="italic">ρ</mml:mi><mml:mi mathvariant="normal">w</mml:mi></mml:msub><mml:msub><mml:mi>c</mml:mi><mml:mi mathvariant="normal">w</mml:mi></mml:msub></mml:mrow><mml:mi>C</mml:mi></mml:mfrac></mml:mstyle><mml:mi mathvariant="bold-italic">u</mml:mi><mml:mi>T</mml:mi></mml:mrow></mml:mfenced><mml:mo>=</mml:mo><mml:mi mathvariant="normal">∇</mml:mi><mml:mo>⋅</mml:mo><mml:mfenced open="(" close=")"><mml:mrow><mml:mstyle displaystyle="true"><mml:mfrac style="display"><mml:mi mathvariant="italic">λ</mml:mi><mml:mi>C</mml:mi></mml:mfrac></mml:mstyle><mml:mi mathvariant="normal">∇</mml:mi><mml:mi>T</mml:mi></mml:mrow></mml:mfenced><mml:mo>,</mml:mo></mml:mrow></mml:math></disp-formula>
          where <inline-formula><mml:math id="M28" display="inline"><mml:mi>T</mml:mi></mml:math></inline-formula> is the temperature, <inline-formula><mml:math id="M29" display="inline"><mml:mrow><mml:msub><mml:mi mathvariant="italic">ρ</mml:mi><mml:mi mathvariant="normal">w</mml:mi></mml:msub></mml:mrow></mml:math></inline-formula> and <inline-formula><mml:math id="M30" display="inline"><mml:mrow><mml:msub><mml:mi>c</mml:mi><mml:mi mathvariant="normal">w</mml:mi></mml:msub></mml:mrow></mml:math></inline-formula> are
density and specific heat capacity of water, <inline-formula><mml:math id="M31" display="inline"><mml:mi>C</mml:mi></mml:math></inline-formula> is the volumetric heat
capacity of the soil and <inline-formula><mml:math id="M32" display="inline"><mml:mi mathvariant="italic">λ</mml:mi></mml:math></inline-formula> the thermal conductivity of the soil.
Typical values of the thermal properties are given in Table 1; these were
used for the analysis presented in the following.</p>
      <p id="d1e729">The second term on the left-hand side is the advective term and describes
the transport of heat operated by the fluid moving in the pores. <inline-formula><mml:math id="M33" display="inline"><mml:mi mathvariant="bold-italic">u</mml:mi></mml:math></inline-formula>
is the Darcy velocity, which is given by Darcy's formula:
            <disp-formula id="Ch1.E2" content-type="numbered"><label>2</label><mml:math id="M34" display="block"><mml:mrow><mml:mi mathvariant="bold-italic">u</mml:mi><mml:mo>=</mml:mo><mml:mo>-</mml:mo><mml:mi>K</mml:mi><mml:mspace linebreak="nobreak" width="0.125em"/><mml:mi mathvariant="normal">∇</mml:mi><mml:mfenced close=")" open="("><mml:mrow><mml:mstyle displaystyle="true"><mml:mfrac style="display"><mml:mi>p</mml:mi><mml:mrow><mml:msub><mml:mi mathvariant="italic">ρ</mml:mi><mml:mi mathvariant="normal">w</mml:mi></mml:msub><mml:mi>g</mml:mi></mml:mrow></mml:mfrac></mml:mstyle><mml:mo>+</mml:mo><mml:msup><mml:mi>z</mml:mi><mml:mo>*</mml:mo></mml:msup></mml:mrow></mml:mfenced><mml:mo>.</mml:mo></mml:mrow></mml:math></disp-formula>
          In Eq. (2) <inline-formula><mml:math id="M35" display="inline"><mml:mi>K</mml:mi></mml:math></inline-formula> is the hydraulic conductivity, <inline-formula><mml:math id="M36" display="inline"><mml:mrow><mml:msub><mml:mi mathvariant="italic">ρ</mml:mi><mml:mi mathvariant="normal">w</mml:mi></mml:msub></mml:mrow></mml:math></inline-formula> is the
density of water, <inline-formula><mml:math id="M37" display="inline"><mml:mi>p</mml:mi></mml:math></inline-formula> is the porewater pressure, <inline-formula><mml:math id="M38" display="inline"><mml:mrow><mml:msup><mml:mi>z</mml:mi><mml:mo>*</mml:mo></mml:msup></mml:mrow></mml:math></inline-formula> is the elevation and
<inline-formula><mml:math id="M39" display="inline"><mml:mi>g</mml:mi></mml:math></inline-formula> is the gravitational constant. The quantity
            <disp-formula id="Ch1.E3" content-type="numbered"><label>3</label><mml:math id="M40" display="block"><mml:mrow><mml:msub><mml:mi mathvariant="bold-italic">v</mml:mi><mml:mi mathvariant="normal">T</mml:mi></mml:msub><mml:mo>=</mml:mo><mml:mstyle displaystyle="true"><mml:mfrac style="display"><mml:mrow><mml:msub><mml:mi mathvariant="italic">ρ</mml:mi><mml:mi mathvariant="normal">w</mml:mi></mml:msub><mml:msub><mml:mi>c</mml:mi><mml:mi mathvariant="normal">w</mml:mi></mml:msub></mml:mrow><mml:mi>C</mml:mi></mml:mfrac></mml:mstyle><mml:mi mathvariant="bold-italic">u</mml:mi></mml:mrow></mml:math></disp-formula>
          is usually referred to as the thermal front velocity. Although it is not the
exact velocity at which a thermal front advances, it is considered to be an
accurate measure of the front velocity.</p>
      <p id="d1e853">The right-hand side of Eq. (1) is the diffusive term that describes the
effect of heat conduction. The quantity
            <disp-formula id="Ch1.E4" content-type="numbered"><label>4</label><mml:math id="M41" display="block"><mml:mrow><mml:mi>a</mml:mi><mml:mo>=</mml:mo><mml:mstyle displaystyle="true"><mml:mfrac style="display"><mml:mi mathvariant="italic">λ</mml:mi><mml:mi>C</mml:mi></mml:mfrac></mml:mstyle></mml:mrow></mml:math></disp-formula>
          is called thermal diffusivity and is a measure of the inertia of the medium
to temperature changes.</p>
      <p id="d1e872">Equation (1) neglects thermal dispersion, which is the spreading of heat
caused by the fluctuation of the micro-streamlines with respect to the main
fluid flow direction because of the existence of a pore system. Although in
solute transport – which is described by the same equation – dispersion is
significant, Rau et al. (2012) show that, at the sub-metre scale, dispersion
of heat in soils is negligible. Dispersion can however occur at a larger
scale because of the combined variability of micro-streamlines and hydraulic
conductivity.</p>
      <p id="d1e876">In the absence of groundwater flow (<inline-formula><mml:math id="M42" display="inline"><mml:mrow><mml:mi>u</mml:mi><mml:mo>=</mml:mo><mml:mn mathvariant="normal">0</mml:mn></mml:mrow></mml:math></inline-formula>), the temperature distribution in the
subsoil can be estimated solving Eq. (1) in a one-dimensional domain. The model by
Hillel (1998) assumes that the temperature at the soil surface (<inline-formula><mml:math id="M43" display="inline"><mml:mrow><mml:mi>z</mml:mi><mml:mo>=</mml:mo><mml:mn mathvariant="normal">0</mml:mn><mml:mo>)</mml:mo></mml:mrow></mml:math></inline-formula> has a
sinusoidal variation throughout the year:
            <disp-formula id="Ch1.E5" content-type="numbered"><label>5</label><mml:math id="M44" display="block"><mml:mrow><mml:mi>T</mml:mi><mml:mo>(</mml:mo><mml:mi>t</mml:mi><mml:mo>)</mml:mo><mml:mo>=</mml:mo><mml:msub><mml:mi>T</mml:mi><mml:mi mathvariant="normal">a</mml:mi></mml:msub><mml:mo>+</mml:mo><mml:msub><mml:mi>A</mml:mi><mml:mn mathvariant="normal">0</mml:mn></mml:msub><mml:mi>sin⁡</mml:mi><mml:mfenced open="[" close="]"><mml:mrow><mml:mi mathvariant="italic">ω</mml:mi><mml:mo>(</mml:mo><mml:mi>t</mml:mi><mml:mo>-</mml:mo><mml:msub><mml:mi>t</mml:mi><mml:mn mathvariant="normal">0</mml:mn></mml:msub><mml:mo>)</mml:mo><mml:mo>+</mml:mo><mml:mi mathvariant="italic">ϕ</mml:mi></mml:mrow></mml:mfenced><mml:mo>,</mml:mo></mml:mrow></mml:math></disp-formula>
          where <inline-formula><mml:math id="M45" display="inline"><mml:mrow><mml:msub><mml:mi>T</mml:mi><mml:mi mathvariant="normal">a</mml:mi></mml:msub></mml:mrow></mml:math></inline-formula> is the mean soil temperature, <inline-formula><mml:math id="M46" display="inline"><mml:mrow><mml:msub><mml:mi>A</mml:mi><mml:mn mathvariant="normal">0</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> is the amplitude
of the annual temperature function, <inline-formula><mml:math id="M47" display="inline"><mml:mrow><mml:mi mathvariant="italic">ω</mml:mi><mml:mo>=</mml:mo><mml:mn mathvariant="normal">2</mml:mn><mml:mi mathvariant="italic">π</mml:mi><mml:mo>/</mml:mo><mml:mn mathvariant="normal">365</mml:mn></mml:mrow></mml:math></inline-formula> is the angular speed
and <inline-formula><mml:math id="M48" display="inline"><mml:mi>t</mml:mi></mml:math></inline-formula> is the day of the year (starting counting from an arbitrary day). <inline-formula><mml:math id="M49" display="inline"><mml:mrow><mml:msub><mml:mi>t</mml:mi><mml:mn mathvariant="normal">0</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula>
can be assumed as the time lag between the occurrence of the minimum temperature
in a year and the arbitrary reference day; in such a case the phase shift is
<inline-formula><mml:math id="M50" display="inline"><mml:mrow><mml:mo>-</mml:mo><mml:mi mathvariant="italic">π</mml:mi><mml:mo>/</mml:mo><mml:mn mathvariant="normal">2</mml:mn></mml:mrow></mml:math></inline-formula>. The model also assumes that at infinite depth the soil temperature
is constant and equal to <inline-formula><mml:math id="M51" display="inline"><mml:mrow><mml:msub><mml:mi>T</mml:mi><mml:mi mathvariant="normal">a</mml:mi></mml:msub></mml:mrow></mml:math></inline-formula>. The temperature at any depth <inline-formula><mml:math id="M52" display="inline"><mml:mi>z</mml:mi></mml:math></inline-formula>
is then a sine function of time and can be represented as
            <disp-formula id="Ch1.E6" content-type="numbered"><label>6</label><mml:math id="M53" display="block"><mml:mrow><mml:mi>T</mml:mi><mml:mo>(</mml:mo><mml:mi>z</mml:mi><mml:mo>,</mml:mo><mml:mi>t</mml:mi><mml:mo>)</mml:mo><mml:mo>=</mml:mo><mml:msub><mml:mi>T</mml:mi><mml:mi mathvariant="normal">a</mml:mi></mml:msub><mml:mo>+</mml:mo><mml:msub><mml:mi>A</mml:mi><mml:mn mathvariant="normal">0</mml:mn></mml:msub><mml:msup><mml:mi>e</mml:mi><mml:mrow><mml:mo>-</mml:mo><mml:mi>z</mml:mi><mml:mo>/</mml:mo><mml:mi>d</mml:mi></mml:mrow></mml:msup><mml:mspace linebreak="nobreak" width="0.125em"/><mml:mfenced close="]" open="["><mml:mrow><mml:mi>sin⁡</mml:mi><mml:mi mathvariant="italic">ω</mml:mi><mml:mfenced open="(" close=")"><mml:mrow><mml:mi>t</mml:mi><mml:mo>-</mml:mo><mml:msub><mml:mi>t</mml:mi><mml:mn mathvariant="normal">0</mml:mn></mml:msub></mml:mrow></mml:mfenced><mml:mo>-</mml:mo><mml:mstyle displaystyle="true"><mml:mfrac style="display"><mml:mi>z</mml:mi><mml:mi>d</mml:mi></mml:mfrac></mml:mstyle><mml:mo>+</mml:mo><mml:mi mathvariant="italic">ϕ</mml:mi></mml:mrow></mml:mfenced><mml:mo>.</mml:mo></mml:mrow></mml:math></disp-formula>
          The constant <inline-formula><mml:math id="M54" display="inline"><mml:mi>d</mml:mi></mml:math></inline-formula> is a characteristic depth, called damping depth, at which
the temperature amplitude decreases to the fraction <inline-formula><mml:math id="M55" display="inline"><mml:mrow><mml:mn mathvariant="normal">1</mml:mn><mml:mo>/</mml:mo><mml:mi>e</mml:mi></mml:mrow></mml:math></inline-formula> of the amplitude
at the soil surface. It is related to the thermal diffusivity of the soil and
the frequency of the temperature fluctuation:
            <disp-formula id="Ch1.E7" content-type="numbered"><label>7</label><mml:math id="M56" display="block"><mml:mrow><mml:mi>d</mml:mi><mml:mo>=</mml:mo><mml:mo>(</mml:mo><mml:mn mathvariant="normal">2</mml:mn><mml:mi>a</mml:mi><mml:mo>/</mml:mo><mml:mi mathvariant="italic">ω</mml:mi><mml:msup><mml:mo>)</mml:mo><mml:mrow><mml:mn mathvariant="normal">1</mml:mn><mml:mo>/</mml:mo><mml:mn mathvariant="normal">2</mml:mn></mml:mrow></mml:msup><mml:mo>.</mml:mo></mml:mrow></mml:math></disp-formula>
          When air temperature is used as input instead of surface temperature, the
effects of solar radiation and wind convection are not taken into account
correctly. Nofziger (2005) suggests increasing the input temperature of
2 <inline-formula><mml:math id="M57" display="inline"><mml:msup><mml:mi/><mml:mo>∘</mml:mo></mml:msup></mml:math></inline-formula>C to take into account the effect of solar radiation on bare
soils; the correction should be smaller for vegetated soils.</p>

      <?xmltex \floatpos{t}?><fig id="Ch1.F2" specific-use="star"><?xmltex \currentcnt{2}?><label>Figure 2</label><caption><p id="d1e1189">Large-scale piping facility.</p></caption>
          <?xmltex \igopts{width=341.433071pt}?><graphic xlink:href="https://hess.copernicus.org/articles/22/1491/2018/hess-22-1491-2018-f02.jpg"/>

        </fig>

      <p id="d1e1198">In the presence of groundwater flow, the temperature distribution in the
subsoil depends on the flow velocity: if the velocity is relatively small, the
contribution of the advective term in Eq. (1) is negligible and the
temperature distribution is again as given by Eq. (6). If the velocity is
large, the temperature field will be different. The relative importance of
advection over conduction is described by the Péclet number, which can be
derived from Eq. (1) by means of dimensional analysis. For a one-dimensional
problem the Péclet number is defined as follows:
            <disp-formula id="Ch1.E8" content-type="numbered"><label>8</label><mml:math id="M58" display="block"><mml:mrow><mml:mi mathvariant="normal">Pe</mml:mi><mml:mo>=</mml:mo><mml:mstyle displaystyle="true"><mml:mfrac style="display"><mml:mrow><mml:mi>u</mml:mi><mml:mspace linebreak="nobreak" width="0.125em"/><mml:mi>l</mml:mi><mml:mspace width="0.125em" linebreak="nobreak"/><mml:msub><mml:mi mathvariant="italic">ρ</mml:mi><mml:mi mathvariant="normal">w</mml:mi></mml:msub><mml:msub><mml:mi>c</mml:mi><mml:mi mathvariant="normal">w</mml:mi></mml:msub></mml:mrow><mml:mi mathvariant="italic">λ</mml:mi></mml:mfrac></mml:mstyle><mml:mo>,</mml:mo></mml:mrow></mml:math></disp-formula>
          where <inline-formula><mml:math id="M59" display="inline"><mml:mi>l</mml:mi></mml:math></inline-formula> is the characteristic length, that is, a length representative of
the phenomenon under investigation. Exact threshold values for the Péclet
number do not exist, but for values<?pagebreak page1495?> much less than unity conduction is
dominant, whereas for values significantly greater than unity advection
prevails; for values in the order of 1 the behaviour of the system is
intermediate. Assuming a characteristic length of 10 m and typical values of
the thermal properties of soils (see Table 1) the Péclet number is on the
order of 1 when the Darcy velocity is on the order of 10<inline-formula><mml:math id="M60" display="inline"><mml:msup><mml:mi/><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">7</mml:mn></mml:mrow></mml:msup></mml:math></inline-formula> m s<inline-formula><mml:math id="M61" display="inline"><mml:msup><mml:mi/><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:msup></mml:math></inline-formula>.</p>
      <p id="d1e1265">A two-dimensional problem such as the transfer of heat in the foundation of a
dike is more accurately described by a two-dimensional Péclet number. Van der Kamp
and Bachu (1989) have defined a non-dimensional number, the geothermal
Péclet number, which is specific for a hydrogeological system where the
conductive heat flow is mainly vertical and the fluid flow is horizontal:
            <disp-formula id="Ch1.E9" content-type="numbered"><label>9</label><mml:math id="M62" display="block"><mml:mrow><mml:mi>P</mml:mi><mml:msub><mml:mi>e</mml:mi><mml:mi mathvariant="normal">g</mml:mi></mml:msub><mml:mo>=</mml:mo><mml:mstyle displaystyle="true"><mml:mfrac style="display"><mml:mrow><mml:msub><mml:mi>q</mml:mi><mml:mi mathvariant="normal">H</mml:mi></mml:msub><mml:msub><mml:mi mathvariant="italic">ρ</mml:mi><mml:mi mathvariant="normal">w</mml:mi></mml:msub><mml:msub><mml:mi>c</mml:mi><mml:mi mathvariant="normal">w</mml:mi></mml:msub><mml:mspace width="0.125em" linebreak="nobreak"/><mml:mi>D</mml:mi><mml:mspace width="0.125em" linebreak="nobreak"/><mml:mi>A</mml:mi></mml:mrow><mml:mi mathvariant="italic">λ</mml:mi></mml:mfrac></mml:mstyle><mml:mo>.</mml:mo></mml:mrow></mml:math></disp-formula>
          In the above formula, <inline-formula><mml:math id="M63" display="inline"><mml:mrow><mml:msub><mml:mi>q</mml:mi><mml:mi mathvariant="normal">H</mml:mi></mml:msub></mml:mrow></mml:math></inline-formula> is the average horizontal Darcy
velocity, <inline-formula><mml:math id="M64" display="inline"><mml:mi>D</mml:mi></mml:math></inline-formula> is the thickness of the hydrological system and <inline-formula><mml:math id="M65" display="inline"><mml:mrow><mml:mi>A</mml:mi><mml:mo>=</mml:mo><mml:mi>D</mml:mi><mml:mo>/</mml:mo><mml:mi>L</mml:mi></mml:mrow></mml:math></inline-formula> is the
aspect ratio of the representative element of the seepage domain, where <inline-formula><mml:math id="M66" display="inline"><mml:mi>L</mml:mi></mml:math></inline-formula>
is given by the horizontal size of the flow path. Conduction in the
horizontal direction is neglected. Van der Kamp (1984) pointed out that
Eq. (9) represents the ratio of the amount of horizontally convected heat
(approximately equal to <inline-formula><mml:math id="M67" display="inline"><mml:mrow><mml:msub><mml:mi>q</mml:mi><mml:mi mathvariant="normal">H</mml:mi></mml:msub><mml:msub><mml:mi>C</mml:mi><mml:mi mathvariant="normal">w</mml:mi></mml:msub><mml:mi>D</mml:mi><mml:mi mathvariant="normal">Δ</mml:mi><mml:mi>T</mml:mi></mml:mrow></mml:math></inline-formula>, where
<inline-formula><mml:math id="M68" display="inline"><mml:mrow><mml:mi mathvariant="normal">Δ</mml:mi><mml:mi>T</mml:mi></mml:mrow></mml:math></inline-formula> is the change in temperature between the top and bottom of the
system) to the amount of heat transferred vertically by conduction
(approximately equal to <inline-formula><mml:math id="M69" display="inline"><mml:mrow><mml:mi mathvariant="italic">λ</mml:mi><mml:mi>L</mml:mi><mml:mi mathvariant="normal">Δ</mml:mi><mml:mi>T</mml:mi><mml:mo>/</mml:mo><mml:mi>D</mml:mi><mml:mo>)</mml:mo></mml:mrow></mml:math></inline-formula>.</p>
      <p id="d1e1405">The most common discussion around Péclet numbers is about the choice of
the characteristic length. In hydrogeological systems the characteristic
length is related to the vertical size of the domain but the choice of its
value is not straightforward. Van der Kamp and Bachu (1989) leave the
question open for hydraulically non-homogeneous systems, i.e. systems where
the fluid flow is concentrated in a layer of limited thickness compared to
the depth of the system.</p>

      <?xmltex \floatpos{t}?><fig id="Ch1.F3" specific-use="star"><?xmltex \currentcnt{3}?><label>Figure 3</label><caption><p id="d1e1411">Cross section of the test dike
indicating the position of the sensors.</p></caption>
          <?xmltex \igopts{width=398.338583pt}?><graphic xlink:href="https://hess.copernicus.org/articles/22/1491/2018/hess-22-1491-2018-f03.pdf"/>

        </fig>

</sec>
<sec id="Ch1.S2.SS2">
  <label>2.2</label><title>Piping test on a large-scale trial embankment</title>
      <p id="d1e1428">In September 2012, in Booneschans, in the northeast of the Netherlands,
backward erosion piping was induced in two trial embankments. The experiments
were part of the IJkdijk (Dutch term for “calibration dike”) program, a
research program initiated in 2005 with the double goal of testing new
monitoring techniques under field conditions and advancing knowledge on
geotechnical failure mechanisms at a large scale. The project involved research
institutes, sensors manufacturers and water authorities. A previous similar
experiment was carried out in 2009 and the related temperature data are
presented in Artières et al. (2010) and Beck et al. (2010).</p>
      <p id="d1e1431">In this paper the test conducted on the “west dike” is described. The dike
is located on the right in Fig. 2. The test dike was surrounded by a
containing ring forming a reservoir with a volume of about 2000 m<inline-formula><mml:math id="M70" display="inline"><mml:msup><mml:mi/><mml:mn mathvariant="normal">3</mml:mn></mml:msup></mml:math></inline-formula>. A
lower and smaller dike ring enclosed a second basin used to control the
downstream water level and ensured full saturation of the foundation layer.
The latter was carefully prepared applying 50 % vacuum during saturation.</p>
      <?pagebreak page1496?><p id="d1e1443">The dike was 3.5 m high, 19 m long and 15 m wide at the bottom. The
geometry of the dike is depicted in Fig. 3. The foundation consisted of a
sand layer with a thickness of 3.25 m (3.00 m by design). An impermeable
foil layer separated this layer from the in situ soil. The foundation soil was a
uniform sand characterized by an average grain size of <inline-formula><mml:math id="M71" display="inline"><mml:mrow><mml:msub><mml:mi>d</mml:mi><mml:mn mathvariant="normal">50</mml:mn></mml:msub><mml:mo>=</mml:mo><mml:mn mathvariant="normal">0.30</mml:mn></mml:mrow></mml:math></inline-formula> mm
and a uniformity coefficient <inline-formula><mml:math id="M72" display="inline"><mml:mrow><mml:mi>U</mml:mi><mml:mo>=</mml:mo><mml:msub><mml:mi>d</mml:mi><mml:mn mathvariant="normal">60</mml:mn></mml:msub><mml:mo>/</mml:mo><mml:msub><mml:mi>d</mml:mi><mml:mn mathvariant="normal">10</mml:mn></mml:msub><mml:mo>=</mml:mo><mml:mn mathvariant="normal">1.69</mml:mn></mml:mrow></mml:math></inline-formula>. The lower part of the
dike was made of a 0.7 m well-compacted clay layer. Given its low
permeability, the clay layer separated the hydraulic fluxes occurring in the
foundation from the fluxes affecting the embankment. The dike body was made
formed by a 1.7 m high, poorly compacted small clay dike on the upstream
side and a sand core covered by organic clay. This composition is
representative of a number of small dikes around the Netherlands.</p>
      <p id="d1e1487">The field trial was named “All-In-One Sensor Validation Test”, since the
occurrence of more than one failure mechanism was possible. By design, the
failure of the dike described in this paper could occur either because of
piping through the foundation soil or because of micro-instability of the
sand core. Failure by overtopping with subsequent erosion of the downstream
slope was also a possibility, in case the previous two did not occur
earlier.</p>
      <p id="d1e1491">Throughout the test, the dike was monitored using a number of innovative
technologies with the aim of testing the capability of such technologies in
predicting imminent failure in field conditions. The technologies included
distributed fibre-optic strain and temperature sensing, fibre Bragg grating,
ground-based radar, ground penetrating radar and electrical resistivity. An
infrared camera mapped the surface temperature of the downstream slope (and
of part of the upstream and downstream basins).</p>

      <?xmltex \floatpos{t}?><fig id="Ch1.F4"><?xmltex \currentcnt{4}?><label>Figure 4</label><caption><p id="d1e1496">Geotextile strip encasing two single-mode and two multi-mode optical
fibres (courtesy of TenCate).</p></caption>
          <?xmltex \igopts{width=236.157874pt}?><graphic xlink:href="https://hess.copernicus.org/articles/22/1491/2018/hess-22-1491-2018-f04.jpg"/>

        </fig>

      <p id="d1e1505">The distributed fibre-optic sensor consisted of two single-mode and two
multi-mode fibres encased in a geotextile strip (Fig. 4). A single strip was
arranged into eight profiles along the length of the dike: five at the interface
between the sand layer and the bottom of the dike (labelled F1 to F5 in
Fig. 3), three on the downstream slope of the dike (labelled F6 to F8).
Single-mode fibres were connected to a reading unit exploiting stimulated
Brillouin scattering to measure strain, while multi-mode fibres were connected
to a reading unit exploiting Raman scattering to measure temperature.
Temperature changes were measured with an accuracy of 0.1 <inline-formula><mml:math id="M73" display="inline"><mml:msup><mml:mi/><mml:mo>∘</mml:mo></mml:msup></mml:math></inline-formula>C, a
spatial resolution of 1 m along the sensor and a frequency of two
measurements per hour. According to the laboratory calibration, the accuracy
of the measurements was higher than 0.1 <inline-formula><mml:math id="M74" display="inline"><mml:msup><mml:mi/><mml:mo>∘</mml:mo></mml:msup></mml:math></inline-formula>C up to a fibre length of
1 km. Please note that in the field, the accuracy may be affected by
additional installation issues not considered in laboratory calibration, such
as sharp bends in the deployed cable, connections and splices, which may
induce step losses not addressed by laboratory calibration (Tyler et al.,
2009). In the field test, significant effort has been paid to avoid sharp
bending: the cable has been deployed with curvature radii larger than 20 cm.
Moreover, neither splices nor connectors were present in the section of fibre
under measurement. Nonetheless, splices and connectors<?pagebreak page1497?> were present
elsewhere, and therefore a field calibration of the DTS system would have
been advisable to compensate the corresponding step losses (Hausner et al.,
2011; Hausner and Kobs, 2016). Unfortunately, field calibration was not
carried out due to practical issues; for this reason some impairments on the
overall accuracy of the system may be expected. Such impairments are expected
to be of a rather small magnitude as the temperature variations expected over
time are modest.</p>

      <?xmltex \floatpos{t}?><fig id="Ch1.F5"><?xmltex \currentcnt{5}?><label>Figure 5</label><caption><p id="d1e1528">Hydraulic load applied to the test dike.</p></caption>
          <?xmltex \igopts{width=236.157874pt}?><graphic xlink:href="https://hess.copernicus.org/articles/22/1491/2018/hess-22-1491-2018-f05.pdf"/>

        </fig>

      <p id="d1e1537">The dike was also equipped with conventional pore pressure transducers, which
provided reference measurements and allowed the growth of the pipes to be
closely monitored: four lines (labelled P1 to P4 in Fig. 3) consisting of 17
sensors each had been installed at the top of the foundation soil during
construction and three lines (labelled P5 to P7) consisting of three sensors each had
been installed in the sand core, right above the clay layer. The conventional
monitoring also included two liquid-level sensors to record the water level
in the upstream and downstream reservoirs, a flowmeter placed at the
discharge point of the downstream basin, visual inspection and manual readings
of discharge and basin levels performed at regular intervals.</p>
      <p id="d1e1541">The dike was forced to collapse slowly, in a controlled manner, in order to
provide the largest amount of data possible to aid in evaluating the
performance of the sensors and understanding the ongoing mechanisms. The
water level was increased in steps in the upstream basin, while the
downstream basin was maintained at an almost constant level of about 10 cm
above the surface of the sand layer to ensure full saturation. The resulting
load (hydraulic head over the dike) is displayed in Fig. 5.</p>
      <p id="d1e1544">The bulk hydraulic conductivity of the sand layer, as calculated from flow
measurements performed at the discharge point of the downstream basin before
piping occurred, was <inline-formula><mml:math id="M75" display="inline"><mml:mrow><mml:mi>K</mml:mi><mml:mo>=</mml:mo><mml:mn mathvariant="normal">1.5</mml:mn><mml:mo>×</mml:mo><mml:msup><mml:mn mathvariant="normal">10</mml:mn><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">4</mml:mn></mml:mrow></mml:msup></mml:mrow></mml:math></inline-formula> m s<inline-formula><mml:math id="M76" display="inline"><mml:msup><mml:mi/><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:msup></mml:math></inline-formula>.</p><?xmltex \hack{\newpage}?>
</sec>
</sec>
<sec id="Ch1.S3">
  <label>3</label><title>Experimental results</title>
<sec id="Ch1.S3.SS1">
  <label>3.1</label><title>Development of piping</title>
      <p id="d1e1598">After 2 days of testing (<inline-formula><mml:math id="M77" display="inline"><mml:mrow><mml:mi>t</mml:mi><mml:mo>=</mml:mo><mml:mn mathvariant="normal">43</mml:mn></mml:mrow></mml:math></inline-formula> h), at the hydraulic load of 1.50 m,
two of the pore pressure sensors at line P1 (downstream) showed a small
pressure drop. Two hours later the first sand boil was detected at the
location <inline-formula><mml:math id="M78" display="inline"><mml:mrow><mml:mi>x</mml:mi><mml:mo>=</mml:mo></mml:mrow></mml:math></inline-formula> 5.2 m. At <inline-formula><mml:math id="M79" display="inline"><mml:mrow><mml:mi>t</mml:mi><mml:mo>=</mml:mo></mml:mrow></mml:math></inline-formula> 50 h, at the hydraulic load of 1.75 m,
three other pore pressure sensors at line P1 showed a small drop, later
followed by the discovery of three new sand boils at <inline-formula><mml:math id="M80" display="inline"><mml:mrow><mml:mi>x</mml:mi><mml:mo>=</mml:mo><mml:mn mathvariant="normal">8.7</mml:mn></mml:mrow></mml:math></inline-formula>, 11.2 and
11.7 m. At <inline-formula><mml:math id="M81" display="inline"><mml:mrow><mml:mi>t</mml:mi><mml:mo>=</mml:mo><mml:mn mathvariant="normal">55</mml:mn></mml:mrow></mml:math></inline-formula> h, after the hydraulic load was increased to 1.85 m,
pressure drops occurred at line P2, indicating that piping channels grew and
reached that far. From that moment on, sand transport occurred continuously,
as revealed by the size of the sand boils increasing with time. Two more
sand boils were detected, at <inline-formula><mml:math id="M82" display="inline"><mml:mrow><mml:mi>x</mml:mi><mml:mo>=</mml:mo><mml:mn mathvariant="normal">17.4</mml:mn></mml:mrow></mml:math></inline-formula> and <inline-formula><mml:math id="M83" display="inline"><mml:mrow><mml:mi>x</mml:mi><mml:mo>=</mml:mo><mml:mn mathvariant="normal">7.0</mml:mn></mml:mrow></mml:math></inline-formula> m, respectively at <inline-formula><mml:math id="M84" display="inline"><mml:mrow><mml:mi>t</mml:mi><mml:mo>=</mml:mo><mml:mn mathvariant="normal">60</mml:mn></mml:mrow></mml:math></inline-formula> and at <inline-formula><mml:math id="M85" display="inline"><mml:mrow><mml:mi>t</mml:mi><mml:mo>=</mml:mo><mml:mn mathvariant="normal">65</mml:mn></mml:mrow></mml:math></inline-formula> h. After 67 h the opening of a controllable drainage
tube that had been installed in the dike foundation as a countermeasure (its
position is indicated in Fig. 3) caused a general pore pressure drop and the
arrest of erosion. At 90 h visual inspection was stopped for safety reasons.
At 94 h the drainage tube was closed to bring the dike to collapse.</p>
      <p id="d1e1706">During the test no significant pore pressure drop was recorded by the
transducers at line P3. Therefore, it can be assumed that no pipe grew that
far and no pipe reached the upstream side. Consequently, piping did not play
any role in the collapse of the dike occurring on the fifth day of testing.</p>
      <p id="d1e1709">From the data collected during the field trial the size of the pipes can be
roughly inferred. The length of the pipes in the first stages can be deduced
knowing that the pipes had reached line P1 of pore pressure transducers, but
not yet line P2. From the size of the sand boils recorded during the visual
inspections the volume of sand eroded is calculated and from these data the
cross-sectional area of a pipe (or a multitude of pipes that developed behind
a sand boil) proves to be between 2.5 and 5 cm<inline-formula><mml:math id="M86" display="inline"><mml:msup><mml:mi/><mml:mn mathvariant="normal">2</mml:mn></mml:msup></mml:math></inline-formula>.</p>
</sec>
<sec id="Ch1.S3.SS2">
  <label>3.2</label><title>Temperature data</title>
      <p id="d1e1729">Temperature measurements started 7 days before the beginning of the test.
Figure 6 shows the evolution of the temperature measured at lines F1 to F5 at
the middle section of the dike (<inline-formula><mml:math id="M87" display="inline"><mml:mrow><mml:mi>x</mml:mi><mml:mo>=</mml:mo><mml:mn mathvariant="normal">10</mml:mn></mml:mrow></mml:math></inline-formula> m). From the beginning of the
measurements (<inline-formula><mml:math id="M88" display="inline"><mml:mrow><mml:mi>t</mml:mi><mml:mo>=</mml:mo><mml:mn mathvariant="normal">0</mml:mn></mml:mrow></mml:math></inline-formula>) to the beginning of the test (<inline-formula><mml:math id="M89" display="inline"><mml:mrow><mml:mi>t</mml:mi><mml:mo>=</mml:mo><mml:mn mathvariant="normal">7</mml:mn></mml:mrow></mml:math></inline-formula> days), the
temperature at the bottom of the dike was nearly constant. Minor differences,
smaller than 1 <inline-formula><mml:math id="M90" display="inline"><mml:msup><mml:mi/><mml:mo>∘</mml:mo></mml:msup></mml:math></inline-formula>C, were due to different distances of the measuring
lines from the surface and different expositions (south or north) of the
slope under which the point is located. The only exception is represented by
line F1. Being the shallowest and lying under the slope facing south, in
the absence of water flow line F1 was the most influenced by the external
environment. Its temperature increased nearly monotonically until the
beginning of the test as a<?pagebreak page1498?> consequence of the increase in the average daily
temperature and solar radiation during the week preceding the test. Since
there is always a time shift between the trend of the air temperature and the
trend of the soil temperature, in the 2 days preceding the beginning of the
test, the soil temperature kept increasing although the average air
temperature was dropping. Immediately after the beginning of the test, the
temperature at F1 started decreasing since the effect of the external
temperature was completely masked by the effect of seepage.</p>

      <?xmltex \floatpos{t}?><fig id="Ch1.F6"><?xmltex \currentcnt{6}?><label>Figure 6</label><caption><p id="d1e1779">Temperature measured by the distributed temperature sensor at
different distances from upstream (F1 to F5) at <inline-formula><mml:math id="M91" display="inline"><mml:mrow><mml:mi>x</mml:mi><mml:mo>=</mml:mo></mml:mrow></mml:math></inline-formula> 10 m.</p></caption>
          <?xmltex \igopts{width=236.157874pt}?><graphic xlink:href="https://hess.copernicus.org/articles/22/1491/2018/hess-22-1491-2018-f06.png"/>

        </fig>

      <p id="d1e1798">A few hours after the beginning of the test, the temperature recorded at F5
started increasing, suggesting that the reservoir water was warmer than the
foundation bulk. Unfortunately, measurements of the water temperature in the
upstream basin were not available due to technical problems. At lines F4 and
F3 the warm front arrived after 2 and 3 days respectively. On the contrary,
at F2 the temperature started to slowly decrease soon after the beginning of
the test and kept decreasing until the arrival of the warm front, more than 3
days later. At line F1 the temperature kept decreasing during the test and
the warm front never arrived.</p>
      <p id="d1e1802">The spectrogram in Fig. 7 depicts the temperature measured at the most
downstream line (F1) as a function of time. Starting from 55 h, localized
temperature drops are visible at the locations where piping was observed, at
approximately <inline-formula><mml:math id="M92" display="inline"><mml:mrow><mml:mi>x</mml:mi><mml:mo>=</mml:mo><mml:mn mathvariant="normal">5</mml:mn></mml:mrow></mml:math></inline-formula>, 11 and 17 m. The time coincides with the recording
of the first pressure drops at line P2. No anomaly in the temperature is
detected at 43 h, when the first pressure drops were recorded at the
downstream line P1. This is consistent with the position of F1, which is
located between P1 and P2. The local temperature variations measured during
the test were all smaller than 1 <inline-formula><mml:math id="M93" display="inline"><mml:msup><mml:mi/><mml:mo>∘</mml:mo></mml:msup></mml:math></inline-formula>C. No temperature anomaly was
observed along the lines F2 to F5.</p>

      <?xmltex \floatpos{t}?><fig id="Ch1.F7"><?xmltex \currentcnt{7}?><label>Figure 7</label><caption><p id="d1e1828">Temperature measured along the dike near the downstream toe (F1).</p></caption>
          <?xmltex \igopts{width=236.157874pt}?><graphic xlink:href="https://hess.copernicus.org/articles/22/1491/2018/hess-22-1491-2018-f07.png"/>

        </fig>

      <?xmltex \floatpos{t}?><fig id="Ch1.F8" specific-use="star"><?xmltex \currentcnt{8}?><label>Figure 8</label><caption><p id="d1e1839">Temperature at the bottom of the dike at 0, 60, 80 and 100 h from
the beginning of the test (red squares indicate the position of sand boils and
black circles the location of temperature sampling points).</p></caption>
          <?xmltex \igopts{width=341.433071pt}?><graphic xlink:href="https://hess.copernicus.org/articles/22/1491/2018/hess-22-1491-2018-f08.png"/>

        </fig>

      <p id="d1e1848">The mechanism that led to the formation of the thermal anomalies is clarified
by Fig. 8, which shows a plan view of the temperature at the base of the dike at
four successive times during the test. The first contour (<inline-formula><mml:math id="M94" display="inline"><mml:mrow><mml:mi>t</mml:mi><mml:mo>=</mml:mo><mml:mn mathvariant="normal">0</mml:mn></mml:mrow></mml:math></inline-formula>) again shows
that the initial temperature was significantly higher under the toe of south
slope (<inline-formula><mml:math id="M95" display="inline"><mml:mrow><mml:mi>y</mml:mi><mml:mo>=</mml:mo><mml:mn mathvariant="normal">15</mml:mn></mml:mrow></mml:math></inline-formula> m). The sequence then shows that the warm inflowing water
preserved its initial temperature while advancing under the dike. The
advancing warm water also pushed the water initially present under the dike
crest progressively downstream, promoting the advance of a cold thermal front
towards the (initially) warmer downstream toe. The cold front advanced faster
at the piping locations than in the soil unaffected by piping, thus producing
the measured localized temperature drops. In the 100 h contour plot,
preferential flow paths can be observed at the sides. Here warm water flows
faster than in the centre of the dike. As no sand boil was observed at the
sides, these preferential paths are believed to be a consequence of the
discontinuity between the soil and the impermeable foil delimiting the
artificial basin. These leakages could not be identified by the pore pressure
readings. The contours also show that the temperature is not uniform along
the <inline-formula><mml:math id="M96" display="inline"><mml:mi>x</mml:mi></mml:math></inline-formula> axis (excluding downstream), neither in the absence of flow (<inline-formula><mml:math id="M97" display="inline"><mml:mrow><mml:mi>t</mml:mi><mml:mo>≤</mml:mo><mml:mn mathvariant="normal">0</mml:mn></mml:mrow></mml:math></inline-formula>)
nor with seepage occurring (<inline-formula><mml:math id="M98" display="inline"><mml:mrow><mml:mi>t</mml:mi><mml:mo>&gt;</mml:mo><mml:mn mathvariant="normal">0</mml:mn></mml:mrow></mml:math></inline-formula>). The temperature is indeed higher at the
centre than at the borders. This can be ascribed to the three-dimensional character of the
test facility, unlike a real dike where the longitudinal dimension is much
larger than the transversal dimension.</p>
      <p id="d1e1906">As suggested by Khan (2008), temperature gradients in the longitudinal
direction can be very informative for the detection of anomalies. Figure 9
shows the gradients along the fibre F1, calculated as the temperature
difference between two points along the fibre located 1 m apart. At
locations <inline-formula><mml:math id="M99" display="inline"><mml:mrow><mml:mi>x</mml:mi><mml:mo>=</mml:mo><mml:mn mathvariant="normal">5</mml:mn></mml:mrow></mml:math></inline-formula> and <inline-formula><mml:math id="M100" display="inline"><mml:mrow><mml:mi>x</mml:mi><mml:mo>=</mml:mo><mml:mn mathvariant="normal">11</mml:mn></mml:mrow></mml:math></inline-formula> m, where sand boils have been observed, the
gradients start to increase at 50 h, stabilize around a value of<?pagebreak page1499?> 0.3 between
about 65 and 85 h, when the hydraulic load is kept nearly constant and then
decrease after 85 h, when the hydraulic load is increased at a rate of
roughly 12 cm h<inline-formula><mml:math id="M101" display="inline"><mml:msup><mml:mi/><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:msup></mml:math></inline-formula>. At <inline-formula><mml:math id="M102" display="inline"><mml:mrow><mml:mi>x</mml:mi><mml:mo>=</mml:mo><mml:mn mathvariant="normal">18</mml:mn></mml:mrow></mml:math></inline-formula> m, where a sand boil was observed
starting from 60 h, the large magnitude of the spatial temperature gradient
is likely to derive from the superposition of two effects: the temperature
decrease caused by piping at that location and the temperature increase
caused by the leakage along the foil at <inline-formula><mml:math id="M103" display="inline"><mml:mrow><mml:mi>x</mml:mi><mml:mo>=</mml:mo><mml:mn mathvariant="normal">19</mml:mn></mml:mrow></mml:math></inline-formula> m (cf. Fig. 8). For
comparison, the graph also reports the gradients at <inline-formula><mml:math id="M104" display="inline"><mml:mrow><mml:mi>x</mml:mi><mml:mo>=</mml:mo><mml:mn mathvariant="normal">14</mml:mn></mml:mrow></mml:math></inline-formula> m where no sand
boil was observed, at least not until 90 h when visual inspection was
stopped. In real embankments high temperature gradients along the dike toe
can be the expression of spatial variability in the hydraulic conductivity of
the foundation soil rather than of internal erosion. Spots of higher
conductivity are anyhow interesting to map because they represent
preferential flow paths where the risk that piping occurs is higher.</p>

      <?xmltex \floatpos{t}?><fig id="Ch1.F9"><?xmltex \currentcnt{9}?><label>Figure 9</label><caption><p id="d1e1985">Temperature gradients along the most downstream line F1 at some
significant points: at <inline-formula><mml:math id="M105" display="inline"><mml:mrow><mml:mi>x</mml:mi><mml:mo>=</mml:mo></mml:mrow></mml:math></inline-formula> 5, <inline-formula><mml:math id="M106" display="inline"><mml:mrow><mml:mi>x</mml:mi><mml:mo>=</mml:mo></mml:mrow></mml:math></inline-formula> 11 and <inline-formula><mml:math id="M107" display="inline"><mml:mrow><mml:mi>x</mml:mi><mml:mo>=</mml:mo></mml:mrow></mml:math></inline-formula> 18 m sand boils were
observed; also at <inline-formula><mml:math id="M108" display="inline"><mml:mrow><mml:mi>x</mml:mi><mml:mo>=</mml:mo></mml:mrow></mml:math></inline-formula> 18 m likely preferential seepage path at the contact
with the foil; at <inline-formula><mml:math id="M109" display="inline"><mml:mrow><mml:mi>x</mml:mi><mml:mo>=</mml:mo></mml:mrow></mml:math></inline-formula> 14 m no traces of piping (until 90 h when visual
inspection was suspended).</p></caption>
          <?xmltex \igopts{width=236.157874pt}?><graphic xlink:href="https://hess.copernicus.org/articles/22/1491/2018/hess-22-1491-2018-f09.png"/>

        </fig>

      <?xmltex \floatpos{t}?><fig id="Ch1.F10"><?xmltex \currentcnt{10}?><label>Figure 10</label><caption><p id="d1e2046">Temperature gradients in the direction of the seepage flow at a
location affected by piping (<inline-formula><mml:math id="M110" display="inline"><mml:mrow><mml:mi>x</mml:mi><mml:mo>=</mml:mo></mml:mrow></mml:math></inline-formula> 11 m) and at a location where no piping
was detected (<inline-formula><mml:math id="M111" display="inline"><mml:mrow><mml:mi>x</mml:mi><mml:mo>=</mml:mo></mml:mrow></mml:math></inline-formula> 14 m).</p></caption>
          <?xmltex \igopts{width=236.157874pt}?><graphic xlink:href="https://hess.copernicus.org/articles/22/1491/2018/hess-22-1491-2018-f10.png"/>

        </fig>

      <p id="d1e2075">Figure 10 shows the temperature gradient in the seepage (transverse)
direction, calculated in proximity of the downstream toe, between fibre F1
and F2, at two locations: <inline-formula><mml:math id="M112" display="inline"><mml:mrow><mml:mi>x</mml:mi><mml:mo>=</mml:mo><mml:mn mathvariant="normal">11</mml:mn></mml:mrow></mml:math></inline-formula> m, where piping occurred, and <inline-formula><mml:math id="M113" display="inline"><mml:mrow><mml:mi>x</mml:mi><mml:mo>=</mml:mo><mml:mn mathvariant="normal">14</mml:mn></mml:mrow></mml:math></inline-formula>,
where no trace of piping was detected. The gradient is non-zero at the
beginning of the test and keeps decreasing during the test as a consequence
of the seepage flow. After 50 h the gradient decreases faster at the
location affected by piping. Here, after 90 h the gradient turns negative.
Indeed, towards the end of the test, the cold water that was initially under
the crest is now at the downstream toe (F1) and the warmer water initially
under the upstream toe is at F2. The even warmer reservoir water could also
have reached F2.</p>
      <p id="d1e2102">The temperature anomalies detected were of very small extent, in the order of
few tenths of a degree. Since the spatial resolution of the sensor is much
larger than the width of a single pipe, it was initially feared that the
averaging performed by the sensor was reducing the actual magnitude of the
temperature anomalies. However, when the pipes developed, the temperature
difference between F1 and F2, which was responsible for the anomalies
produced by piping, was less than 1 <inline-formula><mml:math id="M114" display="inline"><mml:msup><mml:mi/><mml:mo>∘</mml:mo></mml:msup></mml:math></inline-formula>C, and thus the small extent of
the anomalies was largely to be ascribed to the field conditions rather than
to the measuring system. The possibility that a branched net of very small
pipes formed rather than a single larger channel, as observed in medium-scale
experiments (Weijers and Sellmeijer, 1993), would result in a wider eroded
area and a<?pagebreak page1500?> reduced impact of the resolution of the sensor on the measured
temperature anomaly.</p>
      <p id="d1e2114">The small extent of the anomalies could also raise concern about the impact
that the accuracy of the sensor has on the results. As previously stated,
according to the laboratory calibration the accuracy of the measurements was
higher than 0.1 <inline-formula><mml:math id="M115" display="inline"><mml:msup><mml:mi/><mml:mo>∘</mml:mo></mml:msup></mml:math></inline-formula>C, but in the field the accuracy may be affected by
step losses occurring at sharp bends, connections and splices along the
cable. Since the main interest here is in relative measurements, i.e.
temperature variations in space and in time, significant influence of step
losses can be excluded because neither splicings nor connectors were present
in the section of fibre installed under the dike. Moreover, if we consider
the most informative part of the sensor, i.e. the most downstream line F1, step losses induced by bends can
also be reasonably excluded. Of course all the step losses occurring between the reading unit and the line F1 could
affect the accuracy of the measurements performed at the latter, but their
effect on the relative measurements is expected to be negligible. It can be
also excluded that the temperature measurements were influenced by excessive
strain experienced by the fibre during the experiment. Indeed, the maximum
strain measured by the single-mode fibre after 4 days of testing was
around 400 <inline-formula><mml:math id="M116" display="inline"><mml:mi mathvariant="italic">μ</mml:mi></mml:math></inline-formula> strain. In addition, the strain experienced by the
multi-mode fibres dedicated to temperature measurements was certainly much
smaller since these fibres are placed into loose tubes to prevent excessive
stresses.</p>
</sec>
</sec>
<sec id="Ch1.S4">
  <label>4</label><title>Conceptual model</title>
<sec id="Ch1.S4.SS1">
  <label>4.1</label><title>How DTS can detect backward erosion piping</title>
      <p id="d1e2149">Interpretative schemes devised for temperature measurements performed in
earth dams assume that heat transfer occurs mostly by advection in the zones
affected by internal erosion and by conduction in the rest of the soil
(Johansson and Hellström, 2001; Johansson and Sjödal, 2009). Such
schemes apply well to low permeability bodies such as dam cores. They also
assume that the eroded zone extends from the waterside to the landside.
Moreover, it is often stated that the existence of a temperature gradient
between the waterbody and the soil is a necessary condition for the
effectiveness of the temperature measurements (hence the name
<italic>gradient method</italic>, which is sometimes used in lieu of passive
thermometric method).</p>
      <p id="d1e2155">During the experiment described above, the seepage flow induced significant
temperature variations in the entire dike foundation, meaning that advection
prevailed not only in the zones affected by internal erosion but everywhere
in the foundation soil. In addition, the temperature of the waterbody did
not have any influence on the formation of the thermal anomalies. The first
outcome of the test is therefore a demonstration that the conceptual model
commonly used for dams cannot be applied tout court to river embankments
prone to piping.</p>
      <p id="d1e2158">The effect of soil permeability, scale of the structure and length of a
backward eroding cavity on the development of thermal anomalies in damming
structures have been investigated by Radzicki and Bonelli (2010a). In this
paper complementary results are presented that have been obtained<?pagebreak page1501?> focussing
on the mechanism of backward erosion piping and on the effect of hydraulic
loads of short duration.</p>
      <p id="d1e2161">A conceptual model is first presented. It takes into account the necessity to
detect piping in its early stage, that is, when pipes are still confined close
to the landside toe of the embankment. The main assumption of the model is
that a sufficient condition for the formation of a thermal anomaly is a
difference between the soil temperature at the <italic>head</italic> of the pipe
(Fig. 1), that is, where a pipe has its major intake, and the soil temperature
at the downstream toe of the dike, where the sensor is commonly placed. The
large-scale experiment demonstrated that such temperature difference can
occur as the consequence of (at least) two different processes.</p>
<sec id="Ch1.S4.SS1.SSS1">
  <label>4.1.1</label><title>Process 1: Riverside advective front</title>
      <p id="d1e2175">The first process consists in the propagation of an advective thermal front
from the riverside toe up to the head of the pipe (or slightly behind it).
The water that enters the pipe then flows fast to the toe of the embankment
and a distributed sensor located there registers a localized temperature drop
or increase compared to the other regions that have not yet been reached by
the advective front. This process requires that three conditions be
satisfied: (i) the temperature of the waterbody is significantly different
from the subsurface temperature at the point where the sensor is placed;
(ii) advection prevails over the distance between the riverside toe and the
head of the pipe; (iii) the thermal front reaches the head of the pipe in a
relatively short time compared to the time required for the full development
of piping. Condition (i) is sometimes not satisfied during the mid-seasons
when it is likely that both the waterbody and the soil approach the annual
average temperature. The other conditions depend on a number of features such
as geometry, hydraulic and thermal soil properties and magnitude of the
hydraulic load and are discussed in Sect. 5.1.</p>
</sec>
<sec id="Ch1.S4.SS1.SSS2">
  <label>4.1.2</label><title>Process 2: Initial gradient</title>
      <p id="d1e2186">Temperature anomalies can also arise regardless of the temperature of the
waterbody. This second process occurs when – at the beginning of a flood
event – the temperature under the dike is non-uniform and a temperature
gradient exists along the seepage path that will be named here
<italic>initial gradient</italic>. In low permeability soils, where conduction
prevails, during a flood event the initial (non-homogeneous) temperature
distribution is altered only in the pipes. As shown in the experiment, in
more permeable materials the initial temperature distribution is altered
everywhere by seepage, but in the pipes it is modified more quickly than in
the unaffected regions. The initial gradient is generated by the conductive
heat fluxes between the soil and the atmosphere. Such a gradient can only
develop if no seepage occurs under the dike except during flood events or in
losing/gaining streams if seepage velocity is small enough that conduction prevails over advection or
conduction and advection have similar magnitude. The initial gradient is
further discussed in Sect. 5.2.</p>
</sec>
<sec id="Ch1.S4.SS1.SSS3">
  <label>4.1.3</label><title>Combination of the processes</title>
      <p id="d1e2200">The two processes can both occur in the same dike during the same flood
event. The second process is exploitable for detection from the beginning of
a flood event but tends to diminish its effectiveness with time. This was
observed in the experiment, where the strength of the thermal anomalies –
expressed in terms of temperature gradients along the dike toe – decreased
towards the end of the test although it is unlikely that piping had stopped
(Fig. 9). Since the temperature at the base of a dike is pretty uniform far
from the toe, once the water initially under the toe has been pushed
forward and the water initially under the crest has taken its place, the
temperature at the head and tail of the pipes is equal. On the contrary, the
first process is effective only after some time from the beginning of the
flow. The experimental data suggest that the riverside thermal front could
have reached the head of the pipe close to the end of the test. The two
processes can therefore act in synergy, one after the other, allowing
continuous detection of piping.</p>
      <p id="d1e2203">The experimental data also suggest that a decrease of the magnitude of a
thermal anomaly cannot be automatically interpreted as a decrease of the
magnitude of the leakage and that for dikes subject to transient hydraulic
loads it is very difficult to define a unique relationship between thermal
anomalies and leakage magnitude, as has been done for channel dikes
(Artiéres et al., 2007).</p>
</sec>
</sec>
<sec id="Ch1.S4.SS2">
  <label>4.2</label><title>Optimal position of the sensor</title>
      <p id="d1e2215">The experimental results confirmed that the optimal location of a DTS sensor
for the detection of backward erosion piping is close to the landside toe of the
embankment. As a matter of fact only the most downstream portion of the
sensor (F1, Fig. 3) could detect localized temperature variations that could
be associated with piping.</p>
      <p id="d1e2218">One of the main differences between the experiment and a real installation
is that the test dike was built on a homogenous foundation and the sensor was
installed before the impervious base of the dike was placed; the sensor was
therefore located exactly at the depth were piping developed. In existing
dikes this is difficult to achieve. The possibility of detecting piping if the
sensor is not located exactly where piping occurs is discussed with the help
of the flow net illustrated in Fig. 11, obtained as result of a numerical
model described in Bersan et al. (2013). Although most of the water enters a
pipe in proximity of its head, a modification of the flow field is induced in
all the surroundings of the pipe. The flow lines bend towards the pipe and
the vertical component of the seepage flow becomes quite significant at the
bottom of the pipe. An upward flow can modify the initial temperature
gradient normally existing in the vertical<?pagebreak page1502?> direction, producing a thermal
anomaly not only inside the pipe or in a very small region around it (where
heat is conducted from the pipe to the soil) but also tens of centimetres
under the pipe. The vertical flow induced by the pipe is however more
pronounced near the head of the pipe and decreases towards the tail, which
suggests that the optimal position of the sensor is slightly behind the
landside toe.</p>

      <?xmltex \floatpos{t}?><fig id="Ch1.F11"><?xmltex \currentcnt{11}?><label>Figure 11</label><caption><p id="d1e2223">Flow net around a pipe (black rectangle) extending for half of the
seepage length. Exploiting symmetry, only half of the problem is modelled.</p></caption>
          <?xmltex \igopts{width=236.157874pt}?><graphic xlink:href="https://hess.copernicus.org/articles/22/1491/2018/hess-22-1491-2018-f11.png"/>

        </fig>

      <p id="d1e2233">Especially when the foundation soil is heterogeneous or the depth of the
interface between the sand layer and the impervious layer above is highly
variable, we suggest deploying the sensor at more levels at different depths
and maintaining the depth of each level constant along the dike. If the
sensor is installed at variable depths along the dike following the interface
between layers, it is important to map its position very accurately to
facilitate interpretation of the data.</p>
      <p id="d1e2236">The experiment also showed that it can be very helpful for the interpretation
of distributed temperature data if measurements are available also for a few
points along the seepage path. This information can come for example from a
couple of cross-sections instrumented with multiple piezometers, each one
including a thermal sensor. Such a layout has recently been implemented in a
dike stretch along the Adige River in Italy. The idea of a three-dimensional thermal
monitoring system, although with some differences, is also proposed by
Radzicki et al. (2015).</p><?xmltex \hack{\newpage}?>
</sec>
</sec>
<sec id="Ch1.S5">
  <label>5</label><title>Numerical modelling and dimensional analysis</title>
<sec id="Ch1.S5.SS1">
  <label>5.1</label><title>Predicting the propagation of an advective front under a dike</title>
      <p id="d1e2257">The evolution of the temperature under the test dike was simulated using
COMSOL Multiphysics<sup>®</sup>. The equations
describing heat transfer and seepage flow were solved in a coupled manner.
Details on the numerical model are available in Bersan (2015). The model was
first calibrated using the pressure and temperature measurements from the
piping test, then used to predict the behaviour of the test dike over a period
longer than the test duration, in order to understand the effect of the time
factor on the thermal response of a dike. Simplified boundary conditions were
assumed compared to the field conditions: uniform initial temperature of
12 <inline-formula><mml:math id="M117" display="inline"><mml:msup><mml:mi/><mml:mo>∘</mml:mo></mml:msup></mml:math></inline-formula>C, constant inflow temperature of 16 <inline-formula><mml:math id="M118" display="inline"><mml:msup><mml:mi/><mml:mo>∘</mml:mo></mml:msup></mml:math></inline-formula>C and constant
hydraulic load of 3 m. The latter corresponds to an average seepage velocity
of <inline-formula><mml:math id="M119" display="inline"><mml:mrow><mml:mn mathvariant="normal">3</mml:mn><mml:mo>×</mml:mo><mml:msup><mml:mn mathvariant="normal">10</mml:mn><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">5</mml:mn></mml:mrow></mml:msup></mml:mrow></mml:math></inline-formula> m s<inline-formula><mml:math id="M120" display="inline"><mml:msup><mml:mi/><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:msup></mml:math></inline-formula>. The results in Fig. 12 show that
eventually the advective warm front reaches the landside toe, but this takes
more than 4 days. It is inferred that in a small dike with a permeable
foundation, a seepage flow strong enough to induce piping can propagate an
advective front from the riverside up to the landside toe, provided that the
hydraulic load is sustained for a long time. However, many levees are subject
to significant hydraulic loads for very short periods, in the order of half a
day to a few days. The time required for the thermal front to reach the
downstream toe can therefore be of the same order or longer than the duration
of typical flood events.</p>

      <?xmltex \floatpos{t}?><fig id="Ch1.F12"><?xmltex \currentcnt{12}?><label>Figure 12</label><caption><p id="d1e2313">Finite element simulation of a thermal front propagating in the foundation
of the test dike for a constant hydraulic load of 3 m, constant inflow
temperature of 16 <inline-formula><mml:math id="M121" display="inline"><mml:msup><mml:mi/><mml:mo>∘</mml:mo></mml:msup></mml:math></inline-formula>C and uniform initial temperature
<inline-formula><mml:math id="M122" display="inline"><mml:mrow><mml:mi>T</mml:mi><mml:mo>=</mml:mo></mml:mrow></mml:math></inline-formula> 12 <inline-formula><mml:math id="M123" display="inline"><mml:msup><mml:mi/><mml:mo>∘</mml:mo></mml:msup></mml:math></inline-formula>C. On the <inline-formula><mml:math id="M124" display="inline"><mml:mi>x</mml:mi></mml:math></inline-formula> axis the distance from the inflow point is
indicated.</p></caption>
          <?xmltex \igopts{width=236.157874pt}?><graphic xlink:href="https://hess.copernicus.org/articles/22/1491/2018/hess-22-1491-2018-f12.png"/>

        </fig>

      <?xmltex \floatpos{t}?><fig id="Ch1.F13"><?xmltex \currentcnt{13}?><label>Figure 13</label><caption><p id="d1e2359">Domain (grey rectangle) and boundary conditions assumed for the
calculation of the geothermal Péclet number.</p></caption>
          <?xmltex \igopts{width=213.395669pt}?><graphic xlink:href="https://hess.copernicus.org/articles/22/1491/2018/hess-22-1491-2018-f13.pdf"/>

        </fig>

      <?pagebreak page1503?><p id="d1e2369">In order to extend the results of the experiment to a wide range of cases
dimensional analysis was used. The applicability of the geothermal Péclet
number in Eq. (9) to our problem was assessed with the help of a numerical
model again developed in COMSOL Multiphysics<sup>®</sup>
and by solving Eq. (1). The model approximated the foundation by a rectangular
domain as shown in Fig. 13. The same temperature was assigned at the top,
bottom and outflow boundaries; a different temperature was assigned at the
inflow. Modelling only the sand layer and neglecting the convective fluxes
occurring above and under the layer itself is a strong simplification that
produces overestimation of the vertical conductive flux. However we
considered it acceptable since our purpose was determining ranges rather than
exact values. The choice was also motivated by the difficulty anyhow
encountered in correctly placing the bottom boundary. A parametric study in
steady-state conditions was conducted, varying the length and thickness of the
domain as well as the seepage velocity. It emerged that the geothermal
Péclet number only describes the behaviour of the system well if <inline-formula><mml:math id="M125" display="inline"><mml:mi>D</mml:mi></mml:math></inline-formula> is
substituted by <inline-formula><mml:math id="M126" display="inline"><mml:mrow><mml:mi>D</mml:mi><mml:mo>/</mml:mo><mml:mn mathvariant="normal">2</mml:mn></mml:mrow></mml:math></inline-formula> in Eq. (9). The results are presented in Fig. 14: for
values of the geothermal Péclet number much smaller than 1 the system is
conduction-controlled, for values between 1 and 10 the behaviour is
intermediate, whereas for values larger than 10 the system is
advection-controlled. The choice of substituting <inline-formula><mml:math id="M127" display="inline"><mml:mi>D</mml:mi></mml:math></inline-formula> with <inline-formula><mml:math id="M128" display="inline"><mml:mrow><mml:mi>D</mml:mi><mml:mo>/</mml:mo><mml:mn mathvariant="normal">2</mml:mn></mml:mrow></mml:math></inline-formula> can be
explained physically by the fact that in the model by Van der Kamp and
Bachu (1989) conduction occurs in a single direction, promoted by the
temperature difference between the surface and the bottom of the
hydrogeological system, whereas in our model conduction occurs from the
centre of the domain (at temperature <inline-formula><mml:math id="M129" display="inline"><mml:mrow><mml:msub><mml:mi>T</mml:mi><mml:mi mathvariant="normal">w</mml:mi></mml:msub><mml:mo>)</mml:mo></mml:mrow></mml:math></inline-formula> both upwards and
downwards (both at temperature <inline-formula><mml:math id="M130" display="inline"><mml:mrow><mml:msub><mml:mi>T</mml:mi><mml:mn mathvariant="normal">0</mml:mn></mml:msub><mml:mo>)</mml:mo></mml:mrow></mml:math></inline-formula>.</p>
      <p id="d1e2440">In Fig. 15 the geothermal Péclet number is plotted as a function of <inline-formula><mml:math id="M131" display="inline"><mml:mi>D</mml:mi></mml:math></inline-formula>,
the thickness of the sand layer, and <inline-formula><mml:math id="M132" display="inline"><mml:mi>L</mml:mi></mml:math></inline-formula>, the distance along the seepage
path. In order to know whether a thermal front will propagate from the
riverside up to the landside toe, <inline-formula><mml:math id="M133" display="inline"><mml:mi>L</mml:mi></mml:math></inline-formula> must be chosen equal to the width of
the dike at the base. Choosing smaller values, the propagation of the front
can be predicted all along the seepage path. Two cases are plotted in
Fig. 15: a very permeable sand layer (hydraulic conductivity on the order of
<inline-formula><mml:math id="M134" display="inline"><mml:mrow><mml:msup><mml:mn mathvariant="normal">10</mml:mn><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">3</mml:mn></mml:mrow></mml:msup></mml:mrow></mml:math></inline-formula> m s<inline-formula><mml:math id="M135" display="inline"><mml:msup><mml:mi/><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:msup></mml:math></inline-formula>) and a sand layer of medium permeability
(conductivity on the order of <inline-formula><mml:math id="M136" display="inline"><mml:mrow><mml:msup><mml:mn mathvariant="normal">10</mml:mn><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">4</mml:mn></mml:mrow></mml:msup></mml:mrow></mml:math></inline-formula> m s<inline-formula><mml:math id="M137" display="inline"><mml:msup><mml:mi/><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:msup></mml:math></inline-formula>). In both cases a
uniform horizontal gradient <inline-formula><mml:math id="M138" display="inline"><mml:mi>i</mml:mi></mml:math></inline-formula> of 0.1 is considered. The time required by
the thermal front to reach the downstream toe is estimated using the thermal
front velocity in Eq. (3) and can be read on the top <inline-formula><mml:math id="M139" display="inline"><mml:mi>x</mml:mi></mml:math></inline-formula> axis as a function
of <inline-formula><mml:math id="M140" display="inline"><mml:mi>L</mml:mi></mml:math></inline-formula>. This estimate represents an upper bound, since the effect of
conduction is neglected, but the approximation is reasonably good. For the
soil of high hydraulic conductivity the expected behaviour is intermediate or
advective for every possible size of the dike and a thickness of the sand
layer larger than 1. The time required for the front to reach downstream is
in the order of a few days. For <inline-formula><mml:math id="M141" display="inline"><mml:mrow><mml:mi>K</mml:mi><mml:mo>=</mml:mo><mml:msup><mml:mn mathvariant="normal">10</mml:mn><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">4</mml:mn></mml:mrow></mml:msup></mml:mrow></mml:math></inline-formula> m s<inline-formula><mml:math id="M142" display="inline"><mml:msup><mml:mi/><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:msup></mml:math></inline-formula> the expected
behaviour is purely conductive if the sand layer is thinner than 3–4 m.
However, the main constraint seems to be the time required for the front to
reach downstream, which is in the order of tens of days for a medium/large
dike.</p>

      <?xmltex \floatpos{t}?><fig id="Ch1.F14"><?xmltex \currentcnt{14}?><label>Figure 14</label><caption><p id="d1e2571">Temperature distribution along the seepage path as a function of the
geothermal Péclet number for the sand layer in Fig. 12. Results of a
finite element parametric study in steady-state conditions.</p></caption>
          <?xmltex \igopts{width=236.157874pt}?><graphic xlink:href="https://hess.copernicus.org/articles/22/1491/2018/hess-22-1491-2018-f14.pdf"/>

        </fig>

      <?xmltex \floatpos{t}?><fig id="Ch1.F15" specific-use="star"><?xmltex \currentcnt{15}?><label>Figure 15</label><caption><p id="d1e2582">Threshold values of the geothermal Péclet number as a function
of distance along the seepage path (<inline-formula><mml:math id="M143" display="inline"><mml:mi>L</mml:mi></mml:math></inline-formula>) and thickness of the sand layer
(<inline-formula><mml:math id="M144" display="inline"><mml:mi>D</mml:mi></mml:math></inline-formula>) for two different values of hydraulic conductivity. The dotted red line
indicates the arrival times of the thermal front; these must be read on the
top <inline-formula><mml:math id="M145" display="inline"><mml:mi>x</mml:mi></mml:math></inline-formula> axis as a function of distance <inline-formula><mml:math id="M146" display="inline"><mml:mi>L</mml:mi></mml:math></inline-formula>.</p></caption>
          <?xmltex \igopts{width=341.433071pt}?><graphic xlink:href="https://hess.copernicus.org/articles/22/1491/2018/hess-22-1491-2018-f15.pdf"/>

        </fig>

</sec>
<sec id="Ch1.S5.SS2">
  <label>5.2</label><title>Effect of initial temperature distribution on piping detection</title>
      <p id="d1e2627">A temperature gradient is generally present at the base of a dike because of
its geometry: in every slope the distance between the base and the surface
increases from the toes to the top; an increasing distance from the surface
translates to an increasing phase shift and damping of the temperature wave
propagating in the soil. Figure 16 shows an example of the temperature
distribution that can occur at the base of a 1 : 2 slope.</p>
      <p id="d1e2630">The temperature distribution in Fig. 16 was calculated using the finite
element software COMSOL Multiphysics<sup>®</sup> to
solve Eq. (1) under the hypothesis that <inline-formula><mml:math id="M147" display="inline"><mml:mrow><mml:mi>u</mml:mi><mml:mo>=</mml:mo><mml:mn mathvariant="normal">0</mml:mn></mml:mrow></mml:math></inline-formula>. The same result<?pagebreak page1504?> would be
obtained for small seepage velocities. Equation (5) was applied as boundary
condition at the surface of the slope with the following parameters:
<inline-formula><mml:math id="M148" display="inline"><mml:mrow><mml:msub><mml:mi>T</mml:mi><mml:mi mathvariant="normal">a</mml:mi></mml:msub><mml:mo>=</mml:mo><mml:mn mathvariant="normal">9.0</mml:mn></mml:mrow></mml:math></inline-formula> <inline-formula><mml:math id="M149" display="inline"><mml:msup><mml:mi/><mml:mo>∘</mml:mo></mml:msup></mml:math></inline-formula>C, <inline-formula><mml:math id="M150" display="inline"><mml:mrow><mml:msub><mml:mi>A</mml:mi><mml:mn mathvariant="normal">0</mml:mn></mml:msub><mml:mo>=</mml:mo><mml:mn mathvariant="normal">8.5</mml:mn></mml:mrow></mml:math></inline-formula> <inline-formula><mml:math id="M151" display="inline"><mml:msup><mml:mi/><mml:mo>∘</mml:mo></mml:msup></mml:math></inline-formula>C, <inline-formula><mml:math id="M152" display="inline"><mml:mrow><mml:msub><mml:mi>t</mml:mi><mml:mn mathvariant="normal">0</mml:mn></mml:msub><mml:mo>=</mml:mo><mml:mn mathvariant="normal">20</mml:mn></mml:mrow></mml:math></inline-formula> days. The bottom boundary was located at the depth of 20 m from the base
of the slope; there, a constant temperature value equal to the annual average
<inline-formula><mml:math id="M153" display="inline"><mml:mrow><mml:msub><mml:mi>T</mml:mi><mml:mi mathvariant="normal">a</mml:mi></mml:msub></mml:mrow></mml:math></inline-formula> was assigned. We used the numerical model to investigate the
limitations related to the detection of backward erosion piping when the
initial temperature gradient is exploited.</p>

      <?xmltex \floatpos{t}?><fig id="Ch1.F16"><?xmltex \currentcnt{16}?><label>Figure 16</label><caption><p id="d1e2725">Temperature at the base of a 1 : 2 slope from finite element
modelling.</p></caption>
          <?xmltex \igopts{width=213.395669pt}?><graphic xlink:href="https://hess.copernicus.org/articles/22/1491/2018/hess-22-1491-2018-f16.pdf"/>

        </fig>

      <?xmltex \floatpos{t}?><fig id="Ch1.F17"><?xmltex \currentcnt{17}?><label>Figure 17</label><caption><p id="d1e2737">Horizontal temperature gradient at the base of a 1 : 2 slope.
Finite element solutions for average (solid line) and low (dashed lines)
thermal conductivity of the embankment soil.</p></caption>
          <?xmltex \igopts{width=213.395669pt}?><graphic xlink:href="https://hess.copernicus.org/articles/22/1491/2018/hess-22-1491-2018-f17.pdf"/>

        </fig>

      <?xmltex \floatpos{t}?><fig id="Ch1.F18"><?xmltex \currentcnt{18}?><label>Figure 18</label><caption><p id="d1e2748">Temperature difference between a point at the toe of the dike (<inline-formula><mml:math id="M154" display="inline"><mml:mi>B</mml:mi></mml:math></inline-formula>)
and a point under the dike (<inline-formula><mml:math id="M155" display="inline"><mml:mi>A</mml:mi></mml:math></inline-formula>) as a function of depth from ground level
(<inline-formula><mml:math id="M156" display="inline"><mml:mrow><mml:mi>z</mml:mi><mml:mo>)</mml:mo></mml:mrow></mml:math></inline-formula>. Point A is located at a distance <inline-formula><mml:math id="M157" display="inline"><mml:mrow><mml:mi>l</mml:mi><mml:mo>=</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:math></inline-formula>, 3 and 5 m from the toe in
the three graphs respectively. The regions of the graph where the temperature
difference is smaller than 0.2 <inline-formula><mml:math id="M158" display="inline"><mml:msup><mml:mi/><mml:mo>∘</mml:mo></mml:msup></mml:math></inline-formula>C (in absolute value) are
highlighted by grey shading.</p></caption>
          <?xmltex \igopts{width=213.395669pt}?><graphic xlink:href="https://hess.copernicus.org/articles/22/1491/2018/hess-22-1491-2018-f18.pdf"/>

        </fig>

      <p id="d1e2802">Figure 17 shows the gradient along the base of an embankment slope. It can be
observed that even in mid-seasons the gradient is sufficiently large to allow
detection of a pipe just 1 m long with the temperature resolution commonly
offered by DTS systems (provided that the pipe exactly crosses the sensor).
The sensitivity of the model to soil thermal properties was tested: the
dotted lines show that by decreasing the thermal conductivity and heat capacity
of the embankment and upper layer soil (which means assuming higher clay
content and/or lower degree of saturation), the gradient slightly increases
close to the toe, which means there is an even higher probability of piping
being detected.</p>
      <p id="d1e2805">From the graph in Fig. 17 it is evident that the gradient is higher where the
base of the embankment is closer to the surface, i.e. at the toe, and very
small where the base is far from the surface. This occurs because the
temperature in the shallow portion of the subsoil decreases exponentially
with depth. Unfortunately this has a drawback for piping detection that is
worthwhile investigating. In the experiment described in this paper the dike
rested directly on a sand layer prone to piping, so that the interface where
piping developed (and where the temperature was monitored) was very shallow
in the proximity of the toe. However, the piping-prone layer is often not
located directly under the dike but is overlain by an<?pagebreak page1505?> impervious soil layer;
it is therefore farther from the surface and the gradient along the seepage
path could be not large enough to enable piping detection. In Fig. 18 the
temperature difference between two points along the seepage path is
represented as a function of depth. The aim is to represent the potential
temperature difference between the head of a pipe and the toe of the
embankment (where the sensor is located) for three different values of pipe
length: 1, 3 and 5 m. It is assumed that a minimum temperature difference of
0.2 <inline-formula><mml:math id="M159" display="inline"><mml:msup><mml:mi/><mml:mo>∘</mml:mo></mml:msup></mml:math></inline-formula>C is necessary to guarantee piping detection. The areas on
the graphs where the temperature difference is lower than 0.2 <inline-formula><mml:math id="M160" display="inline"><mml:msup><mml:mi/><mml:mo>∘</mml:mo></mml:msup></mml:math></inline-formula>C are
shaded. It turns out that if piping occurs at a depth smaller than 1.25 m
from the ground level, the initial gradient is large enough to enable piping
detection the whole year. If piping occurs at a depth smaller than 5 m and
the pipe is longer than 1 m, the initial gradient is large enough to enable
piping detection for most of the year.</p>
      <p id="d1e2826">It must be specified that the above simulations aim to provide a general
framework rather than the exact temperature distribution and gradients under
an embankment. As a matter of fact daily temperature variations and solar
radiation were not taken into account in the model; very close to the toe
<inline-formula><mml:math id="M161" display="inline"><mml:mrow><mml:mo>(</mml:mo><mml:mo>&lt;</mml:mo></mml:mrow></mml:math></inline-formula> 2 m) they can contribute to an increase or decrease in the gradient
depending on the period of the year. Moreover the temperature distribution
before strong seepage develops is depicted here; in real cases the hydraulic
load increases gradually and the pipes could start developing when the
initial gradient has already been altered to some degree by seepage.</p>
      <p id="d1e2840">The exploitation of the so-called initial gradient for piping detection has
some affinity with the methods used to estimate exchanges between river or
lakes and groundwater (see Sect. 1.4). The main limitation is that
exploitation of seasonal temperature variations is not suitable for detecting
seepage flows that have limited duration. Exploitation of daily temperature
variations is suitable instead but possible only if the sensor is located at
a very small depth (circa <inline-formula><mml:math id="M162" display="inline"><mml:mo>&lt;</mml:mo></mml:math></inline-formula> 0.6 m).</p>
</sec>
</sec>
<sec id="Ch1.S6" sec-type="conclusions">
  <label>6</label><title>Conclusions</title>
      <p id="d1e2859">The paper examines the effect of seepage and backward erosion piping on the
temperature distribution under a dike, giving specific attention to transient
hydraulic conditions typical of river embankments.</p>
      <p id="d1e2862">Data from a field trial conducted on a purpose-built dike are presented that
prove that a DTS sensor located circa 1 m behind the landside toe could
detect temperature anomalies induced by backward eroding cavities in their
early stage.</p>
      <p id="d1e2865">Thanks to the large amount of sensors installed, the experimental data also
offer an overview of the temperature distribution under a dike, with and
without seepage. The first thing deduced is that since soils prone to
backward erosion piping are rather permeable, heat transport by advection can
occur, which means that the water entering at the riverside can reach the
landside maintaining its initial temperature. Two parameters, the geothermal
Péclet number and the thermal front, are suggested in this paper to
ascertain, case by case, whether a thermal front will propagate along the seepage
path.<?pagebreak page1506?> Using these tools it is possible to predict whether an advective front can
travel from the riverside up to the head of a pipe before the critical water
level is reached in the river, thus enabling its early detection. The
geothermal Péclet number predicts the importance of advection over
conduction in hydrogeological systems. Provided that advection is dominant,
the thermal front velocity can be used to calculate the distance that an
advective thermal front travels along the seepage path during a flood event.
Approximately, for sands of high permeability, advection prevails – or is as
strong as conduction – for every possible size of the dike if the sand layer
is thicker than 1. The time required for the advective front to reach the
landside toe is in the order of a few days. For a medium permeability sand
advection occurs at some degree (intermediate behaviour) if the sand layer is
thicker than 3–4 m. However, the main constraint seems to be the time
required by the front to reach downstream, which is in the order of tens of
days for a medium/large dike.</p>
      <p id="d1e2868">Another possibility of identifying piping is given by the non-uniform
temperature distribution at the base of a dike before seepage occurs. The
onset of seepage produces an alteration of this initial temperature
distribution. If advection prevails, as in the field trial, the temperatures
vary both in the foundation soil and in the pipes, but at a faster rate in
the latter. If conduction prevails the temperature varies only in the pipes,
where the seepage rate is very high. A sensor located at the downstream toe
of a dike can record these temperature variations immediately after seepage
begins; detection of piping is thus enabled from the very beginning of the
flood event. Numerical simulations suggest that when the permeable layer is
located at a depth of more than 1 m from ground level the initial gradient
might not be large enough to enable piping detection in some seasons.</p>
      <p id="d1e2872">One fibre deployed at the landside toe of a dike can be sufficient for
piping detection, especially if the soil profile is very regular, but with
more fibres deployed at different depths the reliability of the monitoring
system is higher.</p>
      <p id="d1e2875">Considering the approximations made and the large number of variables at
stake, future research involving numerical modelling of the temperature
variations induced by piping and in-depth analysis of additional field data
would be beneficial for the validation and further development of the
concept developed in this work.</p>
</sec>

      
      </body>
    <back><notes notes-type="dataavailability"><title>Data availability</title>

      <p id="d1e2882">Data are available upon request to the corresponding author
or to Deltares.</p>
  </notes><notes notes-type="competinginterests"><title>Competing interests</title>

      <p id="d1e2888">The authors declare that they have no conflict of
interest.</p>
  </notes><ack><title>Acknowledgements</title><p id="d1e2894">We are thankful to the Fondazione Cassa di Risparmio di Padova e Rovigo that
founded the project Riversafe, on the use of fiber optic sensors for levee
monitoring. The analysis of the field data was performed within the project.
We also acknowledge TenCate Geosynthetics, eDF and geophyConsult for
performing fibre optic measurements and providing their know-how about this
technique.<?xmltex \hack{\newline}?><?xmltex \hack{\newline}?> Edited by: Hannah
Cloke<?xmltex \hack{\newline}?> Reviewed by: two anonymous referees</p></ack><ref-list>
    <title>References</title>

      <ref id="bib1.bib1"><label>1</label><mixed-citation>
Allan, R. J., Douglas, K., and Peirson, W. L.: Development of an experimental
research program into backward erosion piping, in: Proceedings of the 7th
International Conference on Scour and Erosion, Perth, Australia, 2–4
December 2014, 249–255, 2014.</mixed-citation></ref>
      <ref id="bib1.bib2"><label>2</label><mixed-citation>
Artiéres, O., Bonelli, S., Fabre, J.-P., Guidoux, C., Radzicki, K.,
Royet, P., and Vedrenne, C.: Active and passive defences against internal
erosion of dikes, in: Assessment of the risk of internal erosion of water
retaining structures: dams, dikes and levees, Intermediate report of the
working group of ICOLD, Deutsches Talsperren Komitee, Technical University of
Munich, 114 pp., 2007.</mixed-citation></ref>
      <ref id="bib1.bib3"><label>3</label><mixed-citation>
Artiéres, O., Beck, Y. L., Khan, A. A., Cunat, P., Fry, J. J., Courivaud,
J. R., Guidoux, C., and Pinettes, P.: Assessment of dams and dikes behavior
with a fibre optics based monitoring solution, Int. Congress on Dam
Maintenance and Rehabilitation, Zaragaoza, Spain, 23–25 November, 2010.</mixed-citation></ref>
      <ref id="bib1.bib4"><label>4</label><mixed-citation>
Beck, Y. L., Khan, A. A., Cunat, P., Guidoux, C., Artires, O., Mars, J., and
Fry, J. J.: Thermal monitoring of embankment dams by fiber optics, in:
Proceedings of 8th ICOLD European Club Symposium on Dam Safety, ATCOLD
Austrian National Committee on Large Dams, 2010.</mixed-citation></ref>
      <ref id="bib1.bib5"><label>5</label><mixed-citation>
Becker, M. W., Bauer, B., and Hutchinson, A.: Measuring Artificial Recharge
with Fiber Optic Distributed Temperature Sensing, Groundwater, 51, 670–678,
2013.</mixed-citation></ref>
      <ref id="bib1.bib6"><label>6</label><mixed-citation>Bersan, S.: Piping detection in dike foundations by distributed temperature
sensing: Understanding the development of thermal anomalies, PhD Thesis,
University of Padova, Italy, available at:
<uri>http://paduaresearch.cab.unipd.it/8932/</uri>, 2015.</mixed-citation></ref>
      <ref id="bib1.bib7"><label>7</label><mixed-citation>Bersan, S., Jommi, C., Koelewijn, A., and Simonini, P.: Applicability of the
fracture flow interface to the analysis of piping in granular material,
COMSOL Conference, Rotterdam, the Netherlands, available at:
<uri>https://repository.tudelft.nl/islandora/object/uuid:df9f8dd7-fee4-4fbd-9f32-c2e898d1f85f/datastream/OBJ/view</uri>,
2013.</mixed-citation></ref>
      <ref id="bib1.bib8"><label>8</label><mixed-citation>
Bligh, W. G.: Dams, barrages and weirs on porous foundations, Eng. News, 64,
708–710, 1910.</mixed-citation></ref>
      <ref id="bib1.bib9"><label>9</label><mixed-citation>
Briggs, M. A., Lautz, L. K., Buckley, S. F., and Lane, J. W.: Practical
limitations on the use of diurnal temperature signals to quantify groundwater
upwelling, J. Hydrol., 519, 1739–1751, 2014.</mixed-citation></ref>
      <ref id="bib1.bib10"><label>10</label><mixed-citation>Claesson, J., Hellström, G., and Johansson, S.: Temperature analyses for
evaluation of water flow in aquifers and embankment dams, in: Software
package for evaluation of temperature field in embankment dams (manual for
DamTemp v. 1.0), HydroResearch and NeoEnergy, available at:
<uri>http://www.hydroresearch.se/en/temperature/evaluation</uri>, 2001.</mixed-citation></ref>
      <?pagebreak page1507?><ref id="bib1.bib11"><label>11</label><mixed-citation>
Clibborn, J. and Beresford, J. S.: Experiment on passage of water through
sand, Government of India, Central Printing Office, 1902.</mixed-citation></ref>
      <ref id="bib1.bib12"><label>12</label><mixed-citation>
Courivaud, J.-R., Pinettes, P., Guidoux, C., Fry, J.-J., and Beck, Y.-L.:
Fiber optics based monitoring of levees and embankment dams, 31st Annual USSD
Conference, San Diego, California, 11–15 April, 2011.</mixed-citation></ref>
      <ref id="bib1.bib13"><label>13</label><mixed-citation>
Cunat, P.: Détection et évaluation des fuites à travers les
ouvrages hydrauliques en remblai, par analyse de températures
réparties, mesurées par fibre optique, PhD thesis, Université de
Grenoble, Grenoble, France, 2012.</mixed-citation></ref>
      <ref id="bib1.bib14"><label>14</label><mixed-citation>
de Wit, J. M., Sellmeijer, J. B., and Penning, A.: Laboratory testing on
piping, in: Proceedings of the 10th International Conference on Soil
Mechanics and Foundation Engineering, Stockholm, Sweden, 15–19 June 1981,
517–520, 1981.</mixed-citation></ref>
      <ref id="bib1.bib15"><label>15</label><mixed-citation>
Galiana, M.: Internal erosion as failure mechanism of inner dike slope clay
cover by wave overtopping, Extensive report of MSc-internship, GeoDelft
report no. CO-418010/5, GeoDelft, 2005.</mixed-citation></ref>
      <ref id="bib1.bib16"><label>16</label><mixed-citation>
Guidoux C.: Développement et validation d'un système de détection
et de localisation par fibres optiques de zones de fuite dans les digues en
terre, PhD thesis, Université Joseph Fourier, Grenoble, France, 2007.</mixed-citation></ref>
      <ref id="bib1.bib17"><label>17</label><mixed-citation>
Hagerty, D.: Piping/sapping erosion, I: Basic considerations, J. Hydraul.
Eng., 117, 991–1008, 2010.</mixed-citation></ref>
      <ref id="bib1.bib18"><label>18</label><mixed-citation>
Hausner, M. B., Suárez, F., Glander, K. E., Giesen, N. van de, Selker, J.
S., and Tyler, S. W.: Calibrating Single-Ended Fiber-Optic Raman Spectra
Distributed Temperature Sensing Data, Sensors, 11, 10859–10879, 2011.</mixed-citation></ref>
      <ref id="bib1.bib19"><label>19</label><mixed-citation>Hausner, M. B. and Kobs, S.: Identifying and Correcting Step Losses in
Single-Ended Fiber-Optic Distributed Temperature Sensing Data, J. Sensors,
2016, 7073619, <ext-link xlink:href="https://doi.org/10.1155/2016/7073619" ext-link-type="DOI">10.1155/2016/7073619</ext-link>, 2016.</mixed-citation></ref>
      <ref id="bib1.bib20"><label>20</label><mixed-citation>Henault, J.-M., Moreau, G., Blairon, S., Salin, J., Courivaud, J.-R.,
Taillade, F., Merliot, E., Dubois, J.-F., Bertrand, J., Buschaert, S., Mayer,
S., and Delepine-Lesoille, S.: Truly distributed optical fiber sensors for
structural health monitoring: From the telecommunication optical fiber
drawling tower to water leakage detection in dikes and concrete structure
strain monitoring, Adv. Civil Eng., 2010, 930796, <ext-link xlink:href="https://doi.org/10.1155/2010/930796" ext-link-type="DOI">10.1155/2010/930796</ext-link>,
2010.</mixed-citation></ref>
      <ref id="bib1.bib21"><label>21</label><mixed-citation>
Hillel, D: Environmental soil physics, Academic Press, San Diego, CA,
771 pp., 1998.</mixed-citation></ref>
      <ref id="bib1.bib22"><label>22</label><mixed-citation>
ICOLD (International Commission on Large Dams) (Eds.): Internal erosion of
existing dams, levees and dikes, and their foundations, Bulletin 164, vol. 1,
Paris, France, 2015.</mixed-citation></ref>
      <ref id="bib1.bib23"><label>23</label><mixed-citation>
Imre E., Nagy, L., Lörincz, J., Rahemi, N., Schanz, T., Singh, V. P., and
Fityus, S.: Some comments on the entropy-based criteria for piping, Entropy,
17, 2281–2303, 2015.</mixed-citation></ref>
      <ref id="bib1.bib24"><label>24</label><mixed-citation>
Irvine, D. J., Lautz, L. K., Briggs, M. A., Gordon, R. P., and McKenzie, J.
M.: Experimental evaluation of the applicability of phase, amplitude, and
combined methods to determine water flux and thermal diffusivity from
temperature time series using VFLUX 2, J. Hydrol., 531, 728–737, 2015.</mixed-citation></ref>
      <ref id="bib1.bib25"><label>25</label><mixed-citation>
Johansson, S.: Seepage monitoring in embankment dams, PhD thesis, Royal
Institute of Technology, Stockholm, Sweden, 1997.</mixed-citation></ref>
      <ref id="bib1.bib26"><label>26</label><mixed-citation>Johansson, S. and Hellström, G.: DamTemp: Software package for evaluation
of temperature field in embankment dams, HydroResearch and NeoEnergy,
available at: <uri>http://www.hydroresearch.se/en/temperature/evaluation</uri>,
2001.</mixed-citation></ref>
      <ref id="bib1.bib27"><label>27</label><mixed-citation>
Johansson, S. and Sjödal, P.: A guide for seepage monitoring of
embankment dams using temperature measurements, CEATI Report No.
T062700-0214, CEATI International Inc., Dam Safety Interest Group, Montreal,
Quebec, Canada, 2009.</mixed-citation></ref>
      <ref id="bib1.bib28"><label>28</label><mixed-citation>
Johansson, S. and Sjödahl, P: Downstream seepage detection using
temperature measurements and visual inspection: Monitoring experiences from
Røsvatn field test dam and large embankment dams in Sweden, Proceedings
Stability and Breaching of Embankment Dams, Norwegian Electricity Industry
Association (EBL), Oslo, Norway, 2004.</mixed-citation></ref>
      <ref id="bib1.bib29"><label>29</label><mixed-citation>
Kanning, W.: The weakest link, Spatial variability in the piping failure
mechanism of dikes, PhD thesis, Delft University of Technology, Delft, the
Netherlands, 2012.</mixed-citation></ref>
      <ref id="bib1.bib30"><label>30</label><mixed-citation>
Khan, A. A., Vrabie, V., Mars, J. I., Girard, A., and d'Urso, G.: A source
separation technique for processing of thermometric data from fiber-optic DTS
measurements for water leakage identification in dikes, J. Sensors, 8,
1118–1129, 2008.</mixed-citation></ref>
      <ref id="bib1.bib31"><label>31</label><mixed-citation>
Khan, A. A., Vrabie, V., Mars, J. I., Girard, A., and d'Urso, G.: Automatic
monitoring system for singularity detection in dikes by DTS data measurement,
IEEE T. Instrum. Meas., 59, 2167–2175, 2010.</mixed-citation></ref>
      <ref id="bib1.bib32"><label>32</label><mixed-citation>
Koelewijn, A. R., De Vries, G., Van Lottum, H., Förster, U., van Beek, V.
M., and Bezuijen, A.: Full-scale testing of piping prevention measures: Three
tests at the IJkdijk, in: Proc. of the 8th International Conference on
Physical Modelling in Geotechnics, Perth, Australia, 14–17 January 2014,
891–897, 2014.</mixed-citation></ref>
      <ref id="bib1.bib33"><label>33</label><mixed-citation>
Koelewijn, A. R. and Taccari, M. L.: LiveDijk Willemspolder, Praktijkproeven
Verticaal Zanddicht Geotextiel en grofzandbarrière [Live dike
Willemspolder, tests in practice on a geotextile barrier and a coarse sand
filter against piping], report no. 1208555-000-GEO-0006, Deltares, Delft,
2016.</mixed-citation></ref>
      <ref id="bib1.bib34"><label>34</label><mixed-citation>Krause, S., Blume, T., and Cassidy, N. J.: Investigating patterns and
controls of groundwater up-welling in a lowland river by combining
Fibre-optic Distributed Temperature Sensing with observations of vertical
hydraulic gradients, Hydrol. Earth Syst. Sci., 16, 1775–1792,
<ext-link xlink:href="https://doi.org/10.5194/hess-16-1775-2012" ext-link-type="DOI">10.5194/hess-16-1775-2012</ext-link>, 2012.</mixed-citation></ref>
      <ref id="bib1.bib35"><label>35</label><mixed-citation>Lowry, C. S., Walker, J. F., Hunt, R. J., and Anderson, M. P.: Identifying
spatial variability of groundwater discharge in a wetland stream using a
distributed temperature sensor, Water Resour. Res., 43, W10408,
<ext-link xlink:href="https://doi.org/10.1029/2007WR006145" ext-link-type="DOI">10.1029/2007WR006145</ext-link>, 2007.</mixed-citation></ref>
      <ref id="bib1.bib36"><label>36</label><mixed-citation>
Mamer, E. A. and Lowry, C. S.: Locating and quantifying spatially distributed
groundwater/surface water interactions using temperature signals with paired
fiber-optic cables, Water Resour. Res., 49, 7670–7680, 2013.</mixed-citation></ref>
      <ref id="bib1.bib37"><label>37</label><mixed-citation>
Müller-Kirchenbauer, H., Rankl, M., and Schötzer, C.: Mechanism for
regressive erosion beneath dams and barrages, in: Filters in Geotechnical and
Hydraulic Engineering, edited by: Brauns, J., Heibaum, M., and Schuler, U.,
Balkema, Rotterdam, the Netherlands, 369–376, 1993.</mixed-citation></ref>
      <ref id="bib1.bib38"><label>38</label><mixed-citation>
Ng, G. and Oswalt, K.: Levee monitoring system, Better management through
better information, Engineering Systems, April 2010, 1–12, 2010.</mixed-citation></ref>
      <ref id="bib1.bib39"><label>39</label><mixed-citation>Nofziger, D. L.: Soil temperature changes with time and depth: Theory,
available at:
<uri>http://soilphysics.okstate.edu/software/SoilTemperature/document.pdf</uri>,
2005.</mixed-citation></ref>
      <ref id="bib1.bib40"><label>40</label><mixed-citation>
Ojha, C. S. and Singh, V. P.: Determination of critical head in soil piping,
J. Hydraul. Eng., 129, 511–518, 2003.</mixed-citation></ref>
      <?pagebreak page1508?><ref id="bib1.bib41"><label>41</label><mixed-citation>
Peeters, P., Haelterman, K., and Visser, K. P.: About reinventing innovative
technologies for levee monitoring, ICOLD 2013 International Symposium,
Seattle, WA, 2013.</mixed-citation></ref>
      <ref id="bib1.bib42"><label>42</label><mixed-citation>
Radzicki, K. and Bonelli, S.: A possibility to identify piping erosion in
earth hydraulic works using thermal monitoring, in: Proceedings of 8th ICOLD
European Club Symposium on Dam Safety, ATCOLD Austrian National Committee on
Large Dams, Innsbruck, Austria, 22–25 September 2010, 618–623, 2010a.</mixed-citation></ref>
      <ref id="bib1.bib43"><label>43</label><mixed-citation>
Radzicki, K. and Bonelli, S.: Thermal seepage monitoring in the earth dams
with impulse response function analysis model, in: Proceedings of 8th ICOLD
European Club Symposium on Dam Safety, ATCOLD Austrian National Committee on
Large Dams, Innsbruck, Austria, 22–25 September 2010, 624–629, 2010b.</mixed-citation></ref>
      <ref id="bib1.bib44"><label>44</label><mixed-citation>
Radzicki, K., Siudy, A., and Stolinski, M.: An innovative 3D system for
thermal monitoring of seepage and erosion processes and an example of its use
for upgrading the monitoring system at the Kozłowa Góra dam in Poland,
25th Int. Congress on Large Dams, Stavanger, Norway, 13–20 June, 2015.</mixed-citation></ref>
      <ref id="bib1.bib45"><label>45</label><mixed-citation>Rau, G. C., Andersen, M. S., and Acworth, R. I.: Experimental investigation
of the thermal dispersivity term and its significance in the heat transport
equation for flow in sediments, Water Resour. Res., 48, W03511,
<ext-link xlink:href="https://doi.org/10.1029/2011WR011038" ext-link-type="DOI">10.1029/2011WR011038</ext-link>, 2012.</mixed-citation></ref>
      <ref id="bib1.bib46"><label>46</label><mixed-citation>Richards, K. S. and Reddy, K. R.: True triaxial piping test apparatus for
evaluation of piping potential in earth structures, Geotech. Testing J., 33,
83–95, <ext-link xlink:href="https://doi.org/10.1520/GTJ102246" ext-link-type="DOI">10.1520/GTJ102246</ext-link>, 2014.</mixed-citation></ref>
      <ref id="bib1.bib47"><label>47</label><mixed-citation>
Rittgers, J. B., Revil, A., Planes, T., Mooney M. A., and Koelewijn, A. R.:
4-D imaging of seepage in earthen embankments with time-lapse inversion of
self-potential data constrained by acoustic emissions localization, Geophys.
J. Int., 200, 758–772, 2015.</mixed-citation></ref>
      <ref id="bib1.bib48"><label>48</label><mixed-citation>
Schmertmann, J. H.: The non-filter factor of safety against piping through
sands, in: Judgment and Innovation, Geotechnical Special Publication No. 111,
edited by: Silva, F. and Kavazanjian eds, E., ASCE, Reston, VA, 65–132,
2000.</mixed-citation></ref>
      <ref id="bib1.bib49"><label>49</label><mixed-citation>
Sellmeijer, H., de la Cruz, J. L., van Beek, V. M., and Knoe, H.: Fine-tuning
of the backward erosion piping model through small-scale, medium-scale and
IJkdijk experiments, Eur. J. Environ. Civ. En., 15, 1139–1154, 2011.</mixed-citation></ref>
      <ref id="bib1.bib50"><label>50</label><mixed-citation>
Sheffer, M. R., Johansson, S., and Sjödahl, P.: Recent developments in
the use of temperature, resistivity and self-potential methods for monitoring
embankment dam performance, Annual Conference Canadian Dam Association,
Whistler, BC, Canada, 3–8 October, 2009.</mixed-citation></ref>
      <ref id="bib1.bib51"><label>51</label><mixed-citation>Smartec, S. A.: Fiber optic leak detection system for dams and dikes,
Application note, available at:
<uri>https://smartec.ch/wp-content/uploads/sites/2/2017/01/E-APN_FO-LEAK-DETECTION_DAMS-DIKES-_170305_01-1.pdf</uri>,
2017.</mixed-citation></ref>
      <ref id="bib1.bib52"><label>52</label><mixed-citation>Terzaghi, K.: Der Grundbruch an Stauwerken und seine Verhütung [The
failure of dams by piping and its prevention], Die Wasserkraft, 17, 445–449,
1922, reprinted in: Terzaghi, K.: From theory to practice in soil mechanics,
Wiley, New York, NY, 114–118, 1960.
 </mixed-citation></ref><?xmltex \hack{\newpage}?>
      <ref id="bib1.bib53"><label>53</label><mixed-citation>
Thongthamchart, C.: Monitoring of leakage through face slab of Nam Ngum 2
CFRD, International Symposium on dams for a changing world, CIGB ICOLD, 2012.</mixed-citation></ref>
      <ref id="bib1.bib54"><label>54</label><mixed-citation>Tyler, S. W., Selker, J. S., Hausner, M. B., Hatch, C. E., Torgersen, T.,
Thodal, C. E., and Schladow S. G.: Environmental temperature sensing using
Raman spectra DTS fiber-optic methods, Water Resour. Res., 45, W00D23,
<ext-link xlink:href="https://doi.org/10.1029/2008WR007052" ext-link-type="DOI">10.1029/2008WR007052</ext-link>, 2009.</mixed-citation></ref>
      <ref id="bib1.bib55"><label>55</label><mixed-citation>
USACE (US Army Corps of Engineers): Design guidance for levee underseepage,
Technical letter no. 1110-2-569, Washington, DC, 2005.</mixed-citation></ref>
      <ref id="bib1.bib56"><label>56</label><mixed-citation>
Wang, D. Y., Fu, X. D., Jie, Y. X., and Feng, Q. F.: How a suspended cut-off
wall functions: Effect of soil anisotropy in a levee foundation, in:
Proceedings of the 7th International Conference on Scour and Erosion, Perth,
Australia, 2–4 December 2014, 129–136, 2014.</mixed-citation></ref>
      <ref id="bib1.bib57"><label>57</label><mixed-citation>
Weijers, J. B. A. and Sellmeijer, J. B.: A new model to deal with the piping
mechanism, in: Filters in geotechnical and hydraulic engineering, edited by:
Brauns, J., Schuler, U., and Heibaum, M., Balkema, Rotterdam, the
Netherlands, 349–355, 1993.</mixed-citation></ref>
      <ref id="bib1.bib58"><label>58</label><mixed-citation>
WES (US Army Corps of Engineers Waterways Experiment Station): Investigation
of underseepage and its control: Lower Mississippi river levees, Technical
memorandum no. TM-3-424, Vicksburg, MS, 1956.</mixed-citation></ref>
      <ref id="bib1.bib59"><label>59</label><mixed-citation>
van Beek, V. M., Knoeff, H., and Sellmeijer, H.: Observations on the process
of backward erosion piping in small-, medium- and full-scale experiments,
Eur. J. Environ. Civ. En., 15, 1115–1137, 2011.</mixed-citation></ref>
      <ref id="bib1.bib60"><label>60</label><mixed-citation>
van Beek, V. M., Bezuijen, A., Sellmeijer, J. B., and Barends, F. B. J.:
Initiation of backward erosion piping in uniform sands, Géotechnique, 64,
927–941, 2014a.</mixed-citation></ref>
      <ref id="bib1.bib61"><label>61</label><mixed-citation>
van Beek, V. M., Vandenboer, K., van Essen, H. M., and Bezuijen, A.:
Investigation of the backward erosion mechanism in small scale experiments,
in: Proc. of the 8th International Conference on Physical Modelling in
Geotechnics, Perth, Australia, 14–17 January 2014, 855–861, 2014b.</mixed-citation></ref>
      <ref id="bib1.bib62"><label>62</label><mixed-citation>
van der Kamp, G.: Evaluating the influence of groundwater flow systems on
geothermal conditions, in: Energy Developments: New Forms, Renewable,
Conservation, edited by: Curtis, F. A., Pergamon Press, 297–301, 1984.</mixed-citation></ref>
      <ref id="bib1.bib63"><label>63</label><mixed-citation>
van der Kamp, G. and Bachu, S.: Use of dimensional analysis in the study of
thermal effects of various hydrogeological regimes, in: Hydrogeological
Regimes and Their Subsurface Thermal Effect, Geophysical Monograph Series,
vol. 47, edited by: Beck, A. E., Garven, G., and Stegena, L., American
Geophysical Union, Washington, DC, 23–28, 1989.</mixed-citation></ref>

  </ref-list></back>
    <!--<article-title-html>Effectiveness of distributed temperature measurements for early detection of piping in river embankments</article-title-html>
<abstract-html><p>Internal erosion is the cause of a significant percentage of failure and
incidents involving both dams and river embankments in many countries. In the
past 20 years the use of fibre-optic Distributed Temperature Sensing (DTS) in
dams has proved to be an effective tool for the detection of leakages and
internal erosion. This work investigates the effectiveness of DTS for dike
monitoring, focusing on the early detection of backward erosion piping, a
mechanism that affects the foundation layer of structures resting on
permeable, sandy soils. The paper presents data from a piping test performed
on a large-scale experimental dike equipped with a DTS system together with a
large number of accompanying sensors. The effect of seepage and piping on the
temperature field is analysed, eventually identifying the processes that
cause the onset of thermal anomalies around piping channels and thus enable
their early detection. Making use of dimensional analysis, the factors that
influence this thermal response of a dike foundation are identified. Finally
some tools are provided that can be helpful for the design of monitoring
systems and for the interpretation of temperature data.</p></abstract-html>
<ref-html id="bib1.bib1"><label>1</label><mixed-citation>
Allan, R. J., Douglas, K., and Peirson, W. L.: Development of an experimental
research program into backward erosion piping, in: Proceedings of the 7th
International Conference on Scour and Erosion, Perth, Australia, 2–4
December 2014, 249–255, 2014.
</mixed-citation></ref-html>
<ref-html id="bib1.bib2"><label>2</label><mixed-citation>
Artiéres, O., Bonelli, S., Fabre, J.-P., Guidoux, C., Radzicki, K.,
Royet, P., and Vedrenne, C.: Active and passive defences against internal
erosion of dikes, in: Assessment of the risk of internal erosion of water
retaining structures: dams, dikes and levees, Intermediate report of the
working group of ICOLD, Deutsches Talsperren Komitee, Technical University of
Munich, 114 pp., 2007.
</mixed-citation></ref-html>
<ref-html id="bib1.bib3"><label>3</label><mixed-citation>
Artiéres, O., Beck, Y. L., Khan, A. A., Cunat, P., Fry, J. J., Courivaud,
J. R., Guidoux, C., and Pinettes, P.: Assessment of dams and dikes behavior
with a fibre optics based monitoring solution, Int. Congress on Dam
Maintenance and Rehabilitation, Zaragaoza, Spain, 23–25 November, 2010.
</mixed-citation></ref-html>
<ref-html id="bib1.bib4"><label>4</label><mixed-citation>
Beck, Y. L., Khan, A. A., Cunat, P., Guidoux, C., Artires, O., Mars, J., and
Fry, J. J.: Thermal monitoring of embankment dams by fiber optics, in:
Proceedings of 8th ICOLD European Club Symposium on Dam Safety, ATCOLD
Austrian National Committee on Large Dams, 2010.
</mixed-citation></ref-html>
<ref-html id="bib1.bib5"><label>5</label><mixed-citation>
Becker, M. W., Bauer, B., and Hutchinson, A.: Measuring Artificial Recharge
with Fiber Optic Distributed Temperature Sensing, Groundwater, 51, 670–678,
2013.
</mixed-citation></ref-html>
<ref-html id="bib1.bib6"><label>6</label><mixed-citation>
Bersan, S.: Piping detection in dike foundations by distributed temperature
sensing: Understanding the development of thermal anomalies, PhD Thesis,
University of Padova, Italy, available at:
<a href="http://paduaresearch.cab.unipd.it/8932/" target="_blank">http://paduaresearch.cab.unipd.it/8932/</a>, 2015.
</mixed-citation></ref-html>
<ref-html id="bib1.bib7"><label>7</label><mixed-citation>
Bersan, S., Jommi, C., Koelewijn, A., and Simonini, P.: Applicability of the
fracture flow interface to the analysis of piping in granular material,
COMSOL Conference, Rotterdam, the Netherlands, available at:
<a href="https://repository.tudelft.nl/islandora/object/uuid:df9f8dd7-fee4-4fbd-9f32-c2e898d1f85f/datastream/OBJ/view" target="_blank">https://repository.tudelft.nl/islandora/object/uuid:df9f8dd7-fee4-4fbd-9f32-c2e898d1f85f/datastream/OBJ/view</a>,
2013.
</mixed-citation></ref-html>
<ref-html id="bib1.bib8"><label>8</label><mixed-citation>
Bligh, W. G.: Dams, barrages and weirs on porous foundations, Eng. News, 64,
708–710, 1910.
</mixed-citation></ref-html>
<ref-html id="bib1.bib9"><label>9</label><mixed-citation>
Briggs, M. A., Lautz, L. K., Buckley, S. F., and Lane, J. W.: Practical
limitations on the use of diurnal temperature signals to quantify groundwater
upwelling, J. Hydrol., 519, 1739–1751, 2014.
</mixed-citation></ref-html>
<ref-html id="bib1.bib10"><label>10</label><mixed-citation>
Claesson, J., Hellström, G., and Johansson, S.: Temperature analyses for
evaluation of water flow in aquifers and embankment dams, in: Software
package for evaluation of temperature field in embankment dams (manual for
DamTemp v. 1.0), HydroResearch and NeoEnergy, available at:
<a href="http://www.hydroresearch.se/en/temperature/evaluation" target="_blank">http://www.hydroresearch.se/en/temperature/evaluation</a>, 2001.
</mixed-citation></ref-html>
<ref-html id="bib1.bib11"><label>11</label><mixed-citation>
Clibborn, J. and Beresford, J. S.: Experiment on passage of water through
sand, Government of India, Central Printing Office, 1902.
</mixed-citation></ref-html>
<ref-html id="bib1.bib12"><label>12</label><mixed-citation>
Courivaud, J.-R., Pinettes, P., Guidoux, C., Fry, J.-J., and Beck, Y.-L.:
Fiber optics based monitoring of levees and embankment dams, 31st Annual USSD
Conference, San Diego, California, 11–15 April, 2011.
</mixed-citation></ref-html>
<ref-html id="bib1.bib13"><label>13</label><mixed-citation>
Cunat, P.: Détection et évaluation des fuites à travers les
ouvrages hydrauliques en remblai, par analyse de températures
réparties, mesurées par fibre optique, PhD thesis, Université de
Grenoble, Grenoble, France, 2012.
</mixed-citation></ref-html>
<ref-html id="bib1.bib14"><label>14</label><mixed-citation>
de Wit, J. M., Sellmeijer, J. B., and Penning, A.: Laboratory testing on
piping, in: Proceedings of the 10th International Conference on Soil
Mechanics and Foundation Engineering, Stockholm, Sweden, 15–19 June 1981,
517–520, 1981.
</mixed-citation></ref-html>
<ref-html id="bib1.bib15"><label>15</label><mixed-citation>
Galiana, M.: Internal erosion as failure mechanism of inner dike slope clay
cover by wave overtopping, Extensive report of MSc-internship, GeoDelft
report no. CO-418010/5, GeoDelft, 2005.
</mixed-citation></ref-html>
<ref-html id="bib1.bib16"><label>16</label><mixed-citation>
Guidoux C.: Développement et validation d'un système de détection
et de localisation par fibres optiques de zones de fuite dans les digues en
terre, PhD thesis, Université Joseph Fourier, Grenoble, France, 2007.
</mixed-citation></ref-html>
<ref-html id="bib1.bib17"><label>17</label><mixed-citation>
Hagerty, D.: Piping/sapping erosion, I: Basic considerations, J. Hydraul.
Eng., 117, 991–1008, 2010.
</mixed-citation></ref-html>
<ref-html id="bib1.bib18"><label>18</label><mixed-citation>
Hausner, M. B., Suárez, F., Glander, K. E., Giesen, N. van de, Selker, J.
S., and Tyler, S. W.: Calibrating Single-Ended Fiber-Optic Raman Spectra
Distributed Temperature Sensing Data, Sensors, 11, 10859–10879, 2011.
</mixed-citation></ref-html>
<ref-html id="bib1.bib19"><label>19</label><mixed-citation>
Hausner, M. B. and Kobs, S.: Identifying and Correcting Step Losses in
Single-Ended Fiber-Optic Distributed Temperature Sensing Data, J. Sensors,
2016, 7073619, <a href="https://doi.org/10.1155/2016/7073619" target="_blank">https://doi.org/10.1155/2016/7073619</a>, 2016.
</mixed-citation></ref-html>
<ref-html id="bib1.bib20"><label>20</label><mixed-citation>
Henault, J.-M., Moreau, G., Blairon, S., Salin, J., Courivaud, J.-R.,
Taillade, F., Merliot, E., Dubois, J.-F., Bertrand, J., Buschaert, S., Mayer,
S., and Delepine-Lesoille, S.: Truly distributed optical fiber sensors for
structural health monitoring: From the telecommunication optical fiber
drawling tower to water leakage detection in dikes and concrete structure
strain monitoring, Adv. Civil Eng., 2010, 930796, <a href="https://doi.org/10.1155/2010/930796" target="_blank">https://doi.org/10.1155/2010/930796</a>,
2010.
</mixed-citation></ref-html>
<ref-html id="bib1.bib21"><label>21</label><mixed-citation>
Hillel, D: Environmental soil physics, Academic Press, San Diego, CA,
771 pp., 1998.
</mixed-citation></ref-html>
<ref-html id="bib1.bib22"><label>22</label><mixed-citation>
ICOLD (International Commission on Large Dams) (Eds.): Internal erosion of
existing dams, levees and dikes, and their foundations, Bulletin 164, vol. 1,
Paris, France, 2015.
</mixed-citation></ref-html>
<ref-html id="bib1.bib23"><label>23</label><mixed-citation>
Imre E., Nagy, L., Lörincz, J., Rahemi, N., Schanz, T., Singh, V. P., and
Fityus, S.: Some comments on the entropy-based criteria for piping, Entropy,
17, 2281–2303, 2015.
</mixed-citation></ref-html>
<ref-html id="bib1.bib24"><label>24</label><mixed-citation>
Irvine, D. J., Lautz, L. K., Briggs, M. A., Gordon, R. P., and McKenzie, J.
M.: Experimental evaluation of the applicability of phase, amplitude, and
combined methods to determine water flux and thermal diffusivity from
temperature time series using VFLUX 2, J. Hydrol., 531, 728–737, 2015.
</mixed-citation></ref-html>
<ref-html id="bib1.bib25"><label>25</label><mixed-citation>
Johansson, S.: Seepage monitoring in embankment dams, PhD thesis, Royal
Institute of Technology, Stockholm, Sweden, 1997.
</mixed-citation></ref-html>
<ref-html id="bib1.bib26"><label>26</label><mixed-citation>
Johansson, S. and Hellström, G.: DamTemp: Software package for evaluation
of temperature field in embankment dams, HydroResearch and NeoEnergy,
available at: <a href="http://www.hydroresearch.se/en/temperature/evaluation" target="_blank">http://www.hydroresearch.se/en/temperature/evaluation</a>,
2001.
</mixed-citation></ref-html>
<ref-html id="bib1.bib27"><label>27</label><mixed-citation>
Johansson, S. and Sjödal, P.: A guide for seepage monitoring of
embankment dams using temperature measurements, CEATI Report No.
T062700-0214, CEATI International Inc., Dam Safety Interest Group, Montreal,
Quebec, Canada, 2009.
</mixed-citation></ref-html>
<ref-html id="bib1.bib28"><label>28</label><mixed-citation>
Johansson, S. and Sjödahl, P: Downstream seepage detection using
temperature measurements and visual inspection: Monitoring experiences from
Røsvatn field test dam and large embankment dams in Sweden, Proceedings
Stability and Breaching of Embankment Dams, Norwegian Electricity Industry
Association (EBL), Oslo, Norway, 2004.
</mixed-citation></ref-html>
<ref-html id="bib1.bib29"><label>29</label><mixed-citation>
Kanning, W.: The weakest link, Spatial variability in the piping failure
mechanism of dikes, PhD thesis, Delft University of Technology, Delft, the
Netherlands, 2012.
</mixed-citation></ref-html>
<ref-html id="bib1.bib30"><label>30</label><mixed-citation>
Khan, A. A., Vrabie, V., Mars, J. I., Girard, A., and d'Urso, G.: A source
separation technique for processing of thermometric data from fiber-optic DTS
measurements for water leakage identification in dikes, J. Sensors, 8,
1118–1129, 2008.
</mixed-citation></ref-html>
<ref-html id="bib1.bib31"><label>31</label><mixed-citation>
Khan, A. A., Vrabie, V., Mars, J. I., Girard, A., and d'Urso, G.: Automatic
monitoring system for singularity detection in dikes by DTS data measurement,
IEEE T. Instrum. Meas., 59, 2167–2175, 2010.
</mixed-citation></ref-html>
<ref-html id="bib1.bib32"><label>32</label><mixed-citation>
Koelewijn, A. R., De Vries, G., Van Lottum, H., Förster, U., van Beek, V.
M., and Bezuijen, A.: Full-scale testing of piping prevention measures: Three
tests at the IJkdijk, in: Proc. of the 8th International Conference on
Physical Modelling in Geotechnics, Perth, Australia, 14–17 January 2014,
891–897, 2014.
</mixed-citation></ref-html>
<ref-html id="bib1.bib33"><label>33</label><mixed-citation>
Koelewijn, A. R. and Taccari, M. L.: LiveDijk Willemspolder, Praktijkproeven
Verticaal Zanddicht Geotextiel en grofzandbarrière [Live dike
Willemspolder, tests in practice on a geotextile barrier and a coarse sand
filter against piping], report no. 1208555-000-GEO-0006, Deltares, Delft,
2016.
</mixed-citation></ref-html>
<ref-html id="bib1.bib34"><label>34</label><mixed-citation>
Krause, S., Blume, T., and Cassidy, N. J.: Investigating patterns and
controls of groundwater up-welling in a lowland river by combining
Fibre-optic Distributed Temperature Sensing with observations of vertical
hydraulic gradients, Hydrol. Earth Syst. Sci., 16, 1775–1792,
<a href="https://doi.org/10.5194/hess-16-1775-2012" target="_blank">https://doi.org/10.5194/hess-16-1775-2012</a>, 2012.
</mixed-citation></ref-html>
<ref-html id="bib1.bib35"><label>35</label><mixed-citation>
Lowry, C. S., Walker, J. F., Hunt, R. J., and Anderson, M. P.: Identifying
spatial variability of groundwater discharge in a wetland stream using a
distributed temperature sensor, Water Resour. Res., 43, W10408,
<a href="https://doi.org/10.1029/2007WR006145" target="_blank">https://doi.org/10.1029/2007WR006145</a>, 2007.
</mixed-citation></ref-html>
<ref-html id="bib1.bib36"><label>36</label><mixed-citation>
Mamer, E. A. and Lowry, C. S.: Locating and quantifying spatially distributed
groundwater/surface water interactions using temperature signals with paired
fiber-optic cables, Water Resour. Res., 49, 7670–7680, 2013.
</mixed-citation></ref-html>
<ref-html id="bib1.bib37"><label>37</label><mixed-citation>
Müller-Kirchenbauer, H., Rankl, M., and Schötzer, C.: Mechanism for
regressive erosion beneath dams and barrages, in: Filters in Geotechnical and
Hydraulic Engineering, edited by: Brauns, J., Heibaum, M., and Schuler, U.,
Balkema, Rotterdam, the Netherlands, 369–376, 1993.
</mixed-citation></ref-html>
<ref-html id="bib1.bib38"><label>38</label><mixed-citation>
Ng, G. and Oswalt, K.: Levee monitoring system, Better management through
better information, Engineering Systems, April 2010, 1–12, 2010.
</mixed-citation></ref-html>
<ref-html id="bib1.bib39"><label>39</label><mixed-citation>
Nofziger, D. L.: Soil temperature changes with time and depth: Theory,
available at:
<a href="http://soilphysics.okstate.edu/software/SoilTemperature/document.pdf" target="_blank">http://soilphysics.okstate.edu/software/SoilTemperature/document.pdf</a>,
2005.
</mixed-citation></ref-html>
<ref-html id="bib1.bib40"><label>40</label><mixed-citation>
Ojha, C. S. and Singh, V. P.: Determination of critical head in soil piping,
J. Hydraul. Eng., 129, 511–518, 2003.
</mixed-citation></ref-html>
<ref-html id="bib1.bib41"><label>41</label><mixed-citation>
Peeters, P., Haelterman, K., and Visser, K. P.: About reinventing innovative
technologies for levee monitoring, ICOLD 2013 International Symposium,
Seattle, WA, 2013.
</mixed-citation></ref-html>
<ref-html id="bib1.bib42"><label>42</label><mixed-citation>
Radzicki, K. and Bonelli, S.: A possibility to identify piping erosion in
earth hydraulic works using thermal monitoring, in: Proceedings of 8th ICOLD
European Club Symposium on Dam Safety, ATCOLD Austrian National Committee on
Large Dams, Innsbruck, Austria, 22–25 September 2010, 618–623, 2010a.
</mixed-citation></ref-html>
<ref-html id="bib1.bib43"><label>43</label><mixed-citation>
Radzicki, K. and Bonelli, S.: Thermal seepage monitoring in the earth dams
with impulse response function analysis model, in: Proceedings of 8th ICOLD
European Club Symposium on Dam Safety, ATCOLD Austrian National Committee on
Large Dams, Innsbruck, Austria, 22–25 September 2010, 624–629, 2010b.
</mixed-citation></ref-html>
<ref-html id="bib1.bib44"><label>44</label><mixed-citation>
Radzicki, K., Siudy, A., and Stolinski, M.: An innovative 3D system for
thermal monitoring of seepage and erosion processes and an example of its use
for upgrading the monitoring system at the Kozłowa Góra dam in Poland,
25th Int. Congress on Large Dams, Stavanger, Norway, 13–20 June, 2015.
</mixed-citation></ref-html>
<ref-html id="bib1.bib45"><label>45</label><mixed-citation>
Rau, G. C., Andersen, M. S., and Acworth, R. I.: Experimental investigation
of the thermal dispersivity term and its significance in the heat transport
equation for flow in sediments, Water Resour. Res., 48, W03511,
<a href="https://doi.org/10.1029/2011WR011038" target="_blank">https://doi.org/10.1029/2011WR011038</a>, 2012.
</mixed-citation></ref-html>
<ref-html id="bib1.bib46"><label>46</label><mixed-citation>
Richards, K. S. and Reddy, K. R.: True triaxial piping test apparatus for
evaluation of piping potential in earth structures, Geotech. Testing J., 33,
83–95, <a href="https://doi.org/10.1520/GTJ102246" target="_blank">https://doi.org/10.1520/GTJ102246</a>, 2014.
</mixed-citation></ref-html>
<ref-html id="bib1.bib47"><label>47</label><mixed-citation>
Rittgers, J. B., Revil, A., Planes, T., Mooney M. A., and Koelewijn, A. R.:
4-D imaging of seepage in earthen embankments with time-lapse inversion of
self-potential data constrained by acoustic emissions localization, Geophys.
J. Int., 200, 758–772, 2015.
</mixed-citation></ref-html>
<ref-html id="bib1.bib48"><label>48</label><mixed-citation>
Schmertmann, J. H.: The non-filter factor of safety against piping through
sands, in: Judgment and Innovation, Geotechnical Special Publication No. 111,
edited by: Silva, F. and Kavazanjian eds, E., ASCE, Reston, VA, 65–132,
2000.
</mixed-citation></ref-html>
<ref-html id="bib1.bib49"><label>49</label><mixed-citation>
Sellmeijer, H., de la Cruz, J. L., van Beek, V. M., and Knoe, H.: Fine-tuning
of the backward erosion piping model through small-scale, medium-scale and
IJkdijk experiments, Eur. J. Environ. Civ. En., 15, 1139–1154, 2011.
</mixed-citation></ref-html>
<ref-html id="bib1.bib50"><label>50</label><mixed-citation>
Sheffer, M. R., Johansson, S., and Sjödahl, P.: Recent developments in
the use of temperature, resistivity and self-potential methods for monitoring
embankment dam performance, Annual Conference Canadian Dam Association,
Whistler, BC, Canada, 3–8 October, 2009.
</mixed-citation></ref-html>
<ref-html id="bib1.bib51"><label>51</label><mixed-citation>
Smartec, S. A.: Fiber optic leak detection system for dams and dikes,
Application note, available at:
<a href="https://smartec.ch/wp-content/uploads/sites/2/2017/01/E-APN_FO-LEAK-DETECTION_DAMS-DIKES-_170305_01-1.pdf" target="_blank">https://smartec.ch/wp-content/uploads/sites/2/2017/01/E-APN_FO-LEAK-DETECTION_DAMS-DIKES-_170305_01-1.pdf</a>,
2017.
</mixed-citation></ref-html>
<ref-html id="bib1.bib52"><label>52</label><mixed-citation>
Terzaghi, K.: Der Grundbruch an Stauwerken und seine Verhütung [The
failure of dams by piping and its prevention], Die Wasserkraft, 17, 445–449,
1922, reprinted in: Terzaghi, K.: From theory to practice in soil mechanics,
Wiley, New York, NY, 114–118, 1960.

</mixed-citation></ref-html>
<ref-html id="bib1.bib53"><label>53</label><mixed-citation>
Thongthamchart, C.: Monitoring of leakage through face slab of Nam Ngum 2
CFRD, International Symposium on dams for a changing world, CIGB ICOLD, 2012.
</mixed-citation></ref-html>
<ref-html id="bib1.bib54"><label>54</label><mixed-citation>
Tyler, S. W., Selker, J. S., Hausner, M. B., Hatch, C. E., Torgersen, T.,
Thodal, C. E., and Schladow S. G.: Environmental temperature sensing using
Raman spectra DTS fiber-optic methods, Water Resour. Res., 45, W00D23,
<a href="https://doi.org/10.1029/2008WR007052" target="_blank">https://doi.org/10.1029/2008WR007052</a>, 2009.
</mixed-citation></ref-html>
<ref-html id="bib1.bib55"><label>55</label><mixed-citation>
USACE (US Army Corps of Engineers): Design guidance for levee underseepage,
Technical letter no. 1110-2-569, Washington, DC, 2005.
</mixed-citation></ref-html>
<ref-html id="bib1.bib56"><label>56</label><mixed-citation>
Wang, D. Y., Fu, X. D., Jie, Y. X., and Feng, Q. F.: How a suspended cut-off
wall functions: Effect of soil anisotropy in a levee foundation, in:
Proceedings of the 7th International Conference on Scour and Erosion, Perth,
Australia, 2–4 December 2014, 129–136, 2014.
</mixed-citation></ref-html>
<ref-html id="bib1.bib57"><label>57</label><mixed-citation>
Weijers, J. B. A. and Sellmeijer, J. B.: A new model to deal with the piping
mechanism, in: Filters in geotechnical and hydraulic engineering, edited by:
Brauns, J., Schuler, U., and Heibaum, M., Balkema, Rotterdam, the
Netherlands, 349–355, 1993.
</mixed-citation></ref-html>
<ref-html id="bib1.bib58"><label>58</label><mixed-citation>
WES (US Army Corps of Engineers Waterways Experiment Station): Investigation
of underseepage and its control: Lower Mississippi river levees, Technical
memorandum no. TM-3-424, Vicksburg, MS, 1956.
</mixed-citation></ref-html>
<ref-html id="bib1.bib59"><label>59</label><mixed-citation>
van Beek, V. M., Knoeff, H., and Sellmeijer, H.: Observations on the process
of backward erosion piping in small-, medium- and full-scale experiments,
Eur. J. Environ. Civ. En., 15, 1115–1137, 2011.
</mixed-citation></ref-html>
<ref-html id="bib1.bib60"><label>60</label><mixed-citation>
van Beek, V. M., Bezuijen, A., Sellmeijer, J. B., and Barends, F. B. J.:
Initiation of backward erosion piping in uniform sands, Géotechnique, 64,
927–941, 2014a.
</mixed-citation></ref-html>
<ref-html id="bib1.bib61"><label>61</label><mixed-citation>
van Beek, V. M., Vandenboer, K., van Essen, H. M., and Bezuijen, A.:
Investigation of the backward erosion mechanism in small scale experiments,
in: Proc. of the 8th International Conference on Physical Modelling in
Geotechnics, Perth, Australia, 14–17 January 2014, 855–861, 2014b.
</mixed-citation></ref-html>
<ref-html id="bib1.bib62"><label>62</label><mixed-citation>
van der Kamp, G.: Evaluating the influence of groundwater flow systems on
geothermal conditions, in: Energy Developments: New Forms, Renewable,
Conservation, edited by: Curtis, F. A., Pergamon Press, 297–301, 1984.
</mixed-citation></ref-html>
<ref-html id="bib1.bib63"><label>63</label><mixed-citation>
van der Kamp, G. and Bachu, S.: Use of dimensional analysis in the study of
thermal effects of various hydrogeological regimes, in: Hydrogeological
Regimes and Their Subsurface Thermal Effect, Geophysical Monograph Series,
vol. 47, edited by: Beck, A. E., Garven, G., and Stegena, L., American
Geophysical Union, Washington, DC, 23–28, 1989.
</mixed-citation></ref-html>--></article>
