<?xml version="1.0" encoding="UTF-8"?>
<!DOCTYPE article PUBLIC "-//NLM//DTD Journal Publishing with OASIS Tables v3.0 20080202//EN" "journalpub-oasis3.dtd">
<article xmlns:xlink="http://www.w3.org/1999/xlink" xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:oasis="http://docs.oasis-open.org/ns/oasis-exchange/table" xml:lang="en" dtd-version="3.0">
  <front>
    <journal-meta><journal-id journal-id-type="publisher">HESS</journal-id><journal-title-group>
    <journal-title>Hydrology and Earth System Sciences</journal-title>
    <abbrev-journal-title abbrev-type="publisher">HESS</abbrev-journal-title><abbrev-journal-title abbrev-type="nlm-ta">Hydrol. Earth Syst. Sci.</abbrev-journal-title>
  </journal-title-group><issn pub-type="epub">1607-7938</issn><publisher>
    <publisher-name>Copernicus Publications</publisher-name>
    <publisher-loc>Göttingen, Germany</publisher-loc>
  </publisher></journal-meta>
    <article-meta>
      <article-id pub-id-type="doi">10.5194/hess-22-1437-2018</article-id><title-group><article-title>Testing and development of transfer functions for weighing precipitation
gauges in WMO-SPICE</article-title><alt-title>Transfer functions for weighing precipitation
gauges</alt-title>
      </title-group><?xmltex \runningtitle{Transfer functions for weighing precipitation
gauges}?><?xmltex \runningauthor{J.~Kochendorfer et al.}?>
      <contrib-group>
        <contrib contrib-type="author" corresp="yes" rid="aff1">
          <name><surname>Kochendorfer</surname><given-names>John</given-names></name>
          <email>john.kochendorfer@noaa.gov</email>
        </contrib>
        <contrib contrib-type="author" corresp="no" rid="aff2 aff3">
          <name><surname>Nitu</surname><given-names>Rodica</given-names></name>
          
        </contrib>
        <contrib contrib-type="author" corresp="no" rid="aff4">
          <name><surname>Wolff</surname><given-names>Mareile</given-names></name>
          
        </contrib>
        <contrib contrib-type="author" corresp="no" rid="aff2">
          <name><surname>Mekis</surname><given-names>Eva</given-names></name>
          
        </contrib>
        <contrib contrib-type="author" corresp="no" rid="aff5">
          <name><surname>Rasmussen</surname><given-names>Roy</given-names></name>
          
        </contrib>
        <contrib contrib-type="author" corresp="no" rid="aff1">
          <name><surname>Baker</surname><given-names>Bruce</given-names></name>
          
        </contrib>
        <contrib contrib-type="author" corresp="no" rid="aff6">
          <name><surname>Earle</surname><given-names>Michael E.</given-names></name>
          
        <ext-link>https://orcid.org/0000-0002-4862-9276</ext-link></contrib>
        <contrib contrib-type="author" corresp="no" rid="aff7">
          <name><surname>Reverdin</surname><given-names>Audrey</given-names></name>
          
        </contrib>
        <contrib contrib-type="author" corresp="no" rid="aff2">
          <name><surname>Wong</surname><given-names>Kai</given-names></name>
          
        </contrib>
        <contrib contrib-type="author" corresp="no" rid="aff8">
          <name><surname>Smith</surname><given-names>Craig D.</given-names></name>
          
        <ext-link>https://orcid.org/0000-0002-6552-1486</ext-link></contrib>
        <contrib contrib-type="author" corresp="no" rid="aff9">
          <name><surname>Yang</surname><given-names>Daqing</given-names></name>
          
        </contrib>
        <contrib contrib-type="author" corresp="no" rid="aff7">
          <name><surname>Roulet</surname><given-names>Yves-Alain</given-names></name>
          
        </contrib>
        <contrib contrib-type="author" corresp="no" rid="aff1">
          <name><surname>Meyers</surname><given-names>Tilden</given-names></name>
          
        </contrib>
        <contrib contrib-type="author" corresp="no" rid="aff10">
          <name><surname>Buisan</surname><given-names>Samuel</given-names></name>
          
        </contrib>
        <contrib contrib-type="author" corresp="no" rid="aff4">
          <name><surname>Isaksen</surname><given-names>Ketil</given-names></name>
          
        <ext-link>https://orcid.org/0000-0003-2356-5330</ext-link></contrib>
        <contrib contrib-type="author" corresp="no" rid="aff4">
          <name><surname>Brækkan</surname><given-names>Ragnar</given-names></name>
          
        </contrib>
        <contrib contrib-type="author" corresp="no" rid="aff5">
          <name><surname>Landolt</surname><given-names>Scott</given-names></name>
          
        </contrib>
        <contrib contrib-type="author" corresp="no" rid="aff5">
          <name><surname>Jachcik</surname><given-names>Al</given-names></name>
          
        </contrib>
        <aff id="aff1"><label>1</label><institution>Atmospheric Turbulence and Diffusion Division, ARL, National Oceanic and Atmospheric Administration,<?xmltex \hack{\break}?> Oak Ridge, USA</institution>
        </aff>
        <aff id="aff2"><label>2</label><institution>Environment and Climate Change Canada, Toronto, Canada</institution>
        </aff>
        <aff id="aff3"><label>3</label><institution>World Meteorological Organization, Geneva, Switzerland</institution>
        </aff>
        <aff id="aff4"><label>4</label><institution>Norwegian Meteorological Institute, Oslo, Norway</institution>
        </aff>
        <aff id="aff5"><label>5</label><institution>National Center for Atmospheric Research, Boulder, USA</institution>
        </aff>
        <aff id="aff6"><label>6</label><institution>Meteorological Service of Canada, Environment and Climate Change Canada, Dartmouth, Canada</institution>
        </aff>
        <aff id="aff7"><label>7</label><institution>Meteoswiss, Payerne, Switzerland</institution>
        </aff>
        <aff id="aff8"><label>8</label><institution>Environment and Climate Change Canada, Saskatoon, Canada</institution>
        </aff>
        <aff id="aff9"><label>9</label><institution>Environment and Climate Change Canada, Victoria, Canada</institution>
        </aff>
        <aff id="aff10"><label>10</label><institution>Delegación Territorial de AEMET (Spanish National Meteorological
Agency) en Aragon, Zaragoza, Spain</institution>
        </aff>
      </contrib-group>
      <author-notes><corresp id="corr1">John Kochendorfer (john.kochendorfer@noaa.gov)</corresp></author-notes><pub-date><day>27</day><month>February</month><year>2018</year></pub-date>
      
      <volume>22</volume>
      <issue>2</issue>
      <fpage>1437</fpage><lpage>1452</lpage>
      <history>
        <date date-type="received"><day>14</day><month>April</month><year>2017</year></date>
           <date date-type="rev-request"><day>12</day><month>June</month><year>2017</year></date>
           <date date-type="rev-recd"><day>16</day><month>January</month><year>2018</year></date>
           <date date-type="accepted"><day>21</day><month>January</month><year>2018</year></date>
      </history>
      <permissions>
        <copyright-statement>Copyright: © 2018 John Kochendorfer et al.</copyright-statement>
        <copyright-year>2018</copyright-year>
      <license license-type="open-access"><license-p>This work is licensed under the Creative Commons Attribution 3.0 Unported License. To view a copy of this licence, visit <ext-link ext-link-type="uri" xlink:href="https://creativecommons.org/licenses/by/3.0/">https://creativecommons.org/licenses/by/3.0/</ext-link></license-p></license></permissions><self-uri xlink:href="https://hess.copernicus.org/articles/22/1437/2018/hess-22-1437-2018.html">This article is available from https://hess.copernicus.org/articles/22/1437/2018/hess-22-1437-2018.html</self-uri><self-uri xlink:href="https://hess.copernicus.org/articles/22/1437/2018/hess-22-1437-2018.pdf">The full text article is available as a PDF file from https://hess.copernicus.org/articles/22/1437/2018/hess-22-1437-2018.pdf</self-uri>
      <abstract><title>Abstract</title>
    <p id="d1e301">Weighing precipitation gauges are used widely for the measurement of all
forms of precipitation, and are typically more accurate than tipping-bucket
precipitation gauges. This is especially true for the measurement of solid
precipitation; however, weighing precipitation gauge measurements must still
be adjusted for undercatch in snowy, windy conditions. In WMO-SPICE (World
Meteorological Organization Solid Precipitation InterComparison Experiment),
different types of weighing precipitation gauges and shields were compared,
and adjustments were determined for the undercatch of solid precipitation
caused by wind. For the various combinations of gauges and shields,
adjustments using both new and previously existing transfer functions were
evaluated. For most of the gauge and shield combinations, previously derived
transfer functions were found to perform as well as those more recently
derived. This indicates that wind shield type (or lack thereof) is more
important in determining the magnitude of wind-induced undercatch than the
type of weighing precipitation gauge. It also demonstrates the potential for
widespread use of the previously developed transfer functions. Another
overarching result was that, in general, the more effective shields, which
were associated with smaller unadjusted errors, also produced more accurate
measurements after adjustment. This indicates that although transfer
functions can effectively reduce measurement biases, effective wind shielding
is still required for the most accurate measurement of solid precipitation.</p>
  </abstract>
    </article-meta>
  </front>
<body>
      

<sec id="Ch1.S1" sec-type="intro">
  <label>1</label><title>Introduction</title>
      <p id="d1e313">Precipitation measurements are frequently underestimated due to
the interactions among wind, the precipitation gauge, and hydrometeors in the
air around the gauge. Wind deflected over and around a precipitation gauge
can alter the trajectory of hydrometeors falling toward the gauge inlet,
diverting them away from the inlet and causing the gauge to underestimate the
actual precipitation rate. The magnitude of this underestimation is affected
by the wind speed and the phase, size, density, and crystal habit of
precipitation, and is largest for snowy, windy conditions. Many past
observational (e.g., Rasmussen et al., 2012; Wolff et al., 2013, 2015; Ma<?pagebreak page1438?> et
al., 2015; Chen et al., 2015) and theoretical (Theriault et al., 2012; Colli
et al., 2015, 2016; Nespor and Sevruk, 1999; Sevruk et al., 1991; Baghapour
et al., 2017) studies support this finding, including the first World
Meteorological Organization (WMO) Solid Precipitation Measurement
Intercomparison performed in the 1990s (Goodison et al., 1998; Yang et al.,
1995, 1998b). To address this issue, adjustments (or transfer functions) were
developed to correct the undercatch for manual precipitation measurements.
These adjustments were typically a function of wind speed and precipitation
type, as manual precipitation measurements are generally accompanied by
manual precipitation type observations (e.g., Goodison, 1978; Groisman et al.,
1991; Yang et al., 1998a, 1999, 2005). More recently, transfer functions for
automated precipitation measurements have been derived as a function of wind
speed and air temperature (e.g., Kochendorfer et al., 2017b; Wolff et al.,
2015). Transfer functions developed for automated measurements can be applied
over shorter time periods, such as 30–60 min, whereas manual measurements
are mainly adjusted per observation, with a typical observation period of
either 12 or 24 h.</p>
      <p id="d1e316">Since the previous WMO Solid Precipitation Measurement Intercomparison
(Goodison et al., 1998), many new automated sensors designed to measure
solid precipitation have become available. In addition to not requiring a
human observer, which allows them to be deployed in remote locations,
automated measurements can be recorded at higher frequencies and can be used
to monitor precipitation continuously throughout a storm. Instead of
recording precipitation every 12 or 24 h, precipitation accumulation and
rate can be accurately monitored in real time. The primary types of
automated precipitation gauges available today are heated tipping-bucket
gauges, weighing type gauges, and non-catchment gauges. Non-catchment type
precipitation sensors, which typically monitor the intensity of
precipitation using optical sensors, can also be used to record
precipitation type. They can detect very low precipitation rates, but can
also suffer from inaccuracies in measuring the intensity of solid
precipitation over shorter time intervals (e.g., 30 min) due to
variability in hydrometeor size, fall velocity, and density (Roulet et
al., 2016). In addition, it is difficult to validate or calibrate a
non-catchment type precipitation gauge. Heated tipping-bucket precipitation
gauges are tipping-bucket gauges equipped with heaters to melt solid
precipitation collected in the gauge inlet, allowing the tipping mechanism
to measure liquid precipitation as discrete tips. Weighing precipitation
gauges are also used to monitor all phases of precipitation, and they
function by monitoring the total mass of precipitation collected below an
inlet of known area. Weighing gauges should be serviced with antifreeze and
oil to inhibit the freezing of the bucket contents, melt newly collected
precipitation, and inhibit the evaporation of antifreeze and precipitation.
Unlike heated tipping-bucket precipitation gauges, precipitation collected
in a weighing gauge does not need to be heated and melted prior to
measurement, and weighing gauges typically measure very light and very heavy
precipitation more accurately than tipping bucket gauges. However, as the
capacity, resolution, and measurement frequency increase, all weighing
gauges are limited in the smallest amount of precipitation they are able to
resolve, and their ability to discern precipitation from measurement noise.
This limitation is especially important for snowfall, which is often
associated with very low precipitation rates. Additional shortcomings of
weighing gauges are their limited capacity and the need to replace and
dispose of oil and antifreeze every time they are emptied.</p>
      <p id="d1e319">To update the findings of the previous WMO Solid Precipitation Measurement
Intercomparison, which focussed mainly on manual observations (Goodison
et al., 1998), and to evaluate many of the automated precipitation sensors
that are currently in use, the WMO Solid Precipitation Intercomparison
Experiment (WMO-SPICE) was initiated in 2010. The goal of WMO-SPICE was to
study and correct the effects of wind-induced errors on automated solid
precipitation measurements, and also to evaluate new and existing
precipitation and snow depth sensors in different configurations and climate
regimes. Because snowfall and precipitation measurement methods vary from
one region or country to another, and also because errors and biases in
these measurements vary as a function of climate, meteorology, and local
topography (e.g., Kochendorfer et al., 2017a, hereafter referred to in the text as K2017a), one of the goals of WMO-SPICE
was to include as many countries and test beds in the intercomparison as
possible. In addition to the standard national precipitation measurement
systems evaluated at most test beds, many of the WMO-SPICE test beds included
a common set of sensors; this included a reference weighing precipitation
gauge shielded in a double-fence (the double-fence automated reference, or
DFAR) and air temperature, wind speed, and optical precipitation sensors.
The DFAR was modeled after the double-fence intercomparison reference
(DFIR), which was the manual reference configuration used in the previous
WMO Solid Precipitation Measurement Intercomparison (Goodison et al.,
1998), utilizing the same design for the two large, concentric wood shields
that surround the gauge and inner shield. The DFAR is described in more
detail in Ryu et al. (2012, 2016).</p>
      <p id="d1e322">Past WMO-SPICE related work included the development of adjustment functions
for tipping-bucket gauge measurements from the Spanish WMO-SPICE site (Buisán et al., 2017). Measurements from
two WMO-SPICE test sites that pre-date the project were also used to
describe and correct wind-induced undercatch for different types of wind
shields (Kochendorfer et al., 2017b; Wolff et al., 2015). In addition,
measurements from eight different WMO-SPICE sites were used to derive
multi-site adjustments for single-Alter shielded and unshielded weighing
gauges (K2017a). The results of K2017a indicate that despite some climate-
or site-specific biases, multi-site adjustments (or transfer functions) can
be used to effectively minimize the<?pagebreak page1439?> wind-induced undercatch of solid
precipitation. Site host-provided measurements were used to derive the
K2017a multi-site single-Alter shielded and unshielded precipitation
transfer functions. WMO-SPICE also included several manufacturer-provided
weighing precipitation gauges for evaluation, in addition to weighing gauges
tested within other types of shields of more specific national and
scientific interest. These previously unevaluated measurements have been
processed using standardized methods developed and implemented by WMO-SPICE,
allowing for both the creation of new transfer functions and the evaluation
of existing transfer functions derived from independent measurements.</p>
      <p id="d1e326">The goal of this work was to test and recommend transfer functions for all
of the previously unevaluated WMO-SPICE weighing precipitation gauges and
shield configurations. In the present study, transfer functions were
developed and tested using WMO-SPICE measurements from several types of
weighing gauges and shields. These include gauge and shield types that have
never been intercompared before, and for which no other adjustments are
currently available. Previously derived adjustments were also applied to
these measurements to test their applicability and efficacy for each of the
gauge/shield types under evaluation; and also to test the hypothesis that
for a given shield type, the same adjustments can be used to minimize
wind-induced errors for different types of weighing precipitation gauges of
a similar size and shape. Our hypothesis is that the type of shield (or the
lack of a shield) is the primary determinant of undercatch. The alternative
hypothesis is that every type of weighing precipitation gauge requires its
own transfer function. The WMO-SPICE measurements were used to test both
hypotheses by comparing transfer functions derived specifically for each
gauge and shield with transfer functions derived previously using other
gauges and measurements. WMO-SPICE included several manufacturer-provided
unshielded and single-Alter shielded weighing gauges for which no transfer
functions had previously been derived or tested. For these unshielded and
single-Alter shielded gauges, the performance of newly derived transfer
functions were compared to the performance of transfer functions from
K2017a, which were derived using host-provided WMO-SPICE measurements from
eight different test beds. WMO-SPICE also included weighing gauges within the
larger double-Alter, Belfort double-Alter, and Small Double Fence
Intercomparison Reference (SDFIR) shields. For these larger shields, new
transfer functions derived from these WMO-SPICE measurements were compared
to transfer functions derived from measurements that predate WMO-SPICE (Kochendorfer et al., 2017b, hereafter referred to in the text as K2017b). Based on all these
evaluations, specific transfer functions are recommended for all of the
weighing gauges and wind shields included in WMO-SPICE.</p>
</sec>
<sec id="Ch1.S2">
  <label>2</label><title>Methods</title>
<sec id="Ch1.S2.SS1">
  <label>2.1</label><title>Intercomparison overview</title>
      <p id="d1e344">Measurements from all WMO-SPICE sites for which weighing precipitation gauge
measurements were available for evaluation are included in this study. All
of the sites included in this evaluation used a DFAR as the reference
configuration. The reference precipitation measurements recorded at these
WMO-SPICE sites were compared to simultaneous measurements from the gauges
under evaluation. Catch efficiencies (CE), defined as the ratio of accumulated
precipitation reported by a gauge under test to that reported by the
reference configuration, were calculated. Using the computed catch
efficiencies and concurrent measurements of air temperature and wind speed,
transfer functions were created for the weighing gauges under evaluation.
The same set of measurements was also used to evaluate independently derived
transfer functions from K2017a and K2017b. Based on the results of these
evaluations, transfer functions are recommended for all of the weighing
gauges included in the study.</p>
</sec>
<sec id="Ch1.S2.SS2">
  <label>2.2</label><title>Precipitation measurements</title>
      <p id="d1e355">Weighing gauges and shield configurations tested at six of the WMO-SPICE
test beds (Fig. 1) are included in this study. In addition, Fig. 1 includes
the percentage of the total annual precipitation that is solid, as estimated
using either 30-year (1981–2010) climate normals or the best available
proxy data for these locations. These values, which ranged from 25 to 45 %, demonstrate the contribution of solid precipitation to the annual
water balance. These sites are described in more detail in K2017a. The
gauges were evaluated using measurements recorded from two
winter seasons (1 October 2013–30 April 2014 and 1 October 2014–30 April 2015) from this period considered in the
present analysis. Measurements were recorded at either 1 min or 6 s
intervals, and transferred to a central database at the National Center for
Atmospheric Research (NCAR) in Boulder, CO. The Double Fence Automated
Reference (DFAR), which was defined as the automated reference for
WMO-SPICE, consisted of either an OTT Pluvio<inline-formula><mml:math id="M1" display="inline"><mml:msup><mml:mi/><mml:mn mathvariant="normal">2</mml:mn></mml:msup></mml:math></inline-formula> or a Geonor T-200B3
within a DFIR shield, and was used as the reference for all of the
measurements evaluated here (Nitu, 2012). The DFIR shield as described
by Goodison et al. (1998) comprises two concentric, octagonal fences
constructed out of 1.5 m long wooden lath, with the outer shield having a
diameter of 12 m, and the inner shield having a diameter of 4 m. For the
DFAR, at the center of the inner shield the weighing gauge is installed in a
single-Alter shield. Typically, the top of the single-Alter shield and the
inlet of the weighing gauge within the DFAR are at a height of 3 m, but at
Weissfluhjoch and Haukeliseter they were installed higher than this (at 3.5
and 4.05 m, respectively) to prevent drifting snow from burying the shield
and gauge.</p>

      <?xmltex \floatpos{t}?><fig id="Ch1.F1" specific-use="star"><?xmltex \currentcnt{1}?><label>Figure 1</label><caption><p id="d1e369">Map of WMO-SPICE test sites with weighing gauges considered in this
study. In addition, the percent of total precipitation that occurred as solid
precipitation is shown in brackets. For the Caribou Creek, Bratt's Lake,
Center for Atmospheric Research and Experiments (CARE), and Marshall sites
the closest sites with 30 year climate normals (1981–2010) were used; at
Haukeliseter and at Weissfluhjoch local observations were used from
1994 to 2017 and 1981 to 2010, respectively.</p></caption>
          <?xmltex \igopts{width=426.791339pt}?><graphic xlink:href="https://hess.copernicus.org/articles/22/1437/2018/hess-22-1437-2018-f01.png"/>

        </fig>

      <?pagebreak page1440?><p id="d1e378"><?xmltex \hack{\newpage}?>The weighing gauge models included in this study are detailed
in Table 1, and include the Sutron TPG, Meteoservis MRW500, MPS systém
TRwS 405, Geonor T-200-MD3W (1500 mm capacity), Geonor T-200B3 (600 mm
capacity), and OTT Pluvio<inline-formula><mml:math id="M2" display="inline"><mml:msup><mml:mi/><mml:mn mathvariant="normal">2</mml:mn></mml:msup></mml:math></inline-formula>. The shield configurations of these gauges
are provided in Table 2. The TRwS 405 (MPS systém, TRwS 405, Slovakia)
has a heated 400 cm<inline-formula><mml:math id="M3" display="inline"><mml:msup><mml:mi/><mml:mn mathvariant="normal">2</mml:mn></mml:msup></mml:math></inline-formula> orifice, a 750 mm capacity, and uses a strain
gauge type load cell to measure the mass of precipitation accumulated within
its bucket (Table 1). It was provided by the manufacturer without a wind
shield and tested at both the Haukeliseter and Marshall test beds (Table 2,
Fig. 2a). The MRW500 (Meteoservis, MRW500, Czech Republic) has a heated
500 cm<inline-formula><mml:math id="M4" display="inline"><mml:msup><mml:mi/><mml:mn mathvariant="normal">2</mml:mn></mml:msup></mml:math></inline-formula> orifice and a 900 or 1800 mm capacity (with or without
antifreeze), also employs strain gauges for weight measurement (Table 1), and
was tested at the Marshall and Bratt's Lake test beds. Both an unshielded
(Fig. 2b) and a shielded gauge (Fig. 2c) were installed at each site
(Table 2), with the small, manufacturer-provided shield constructed out of
fixed metal slats and attached to the same base as the gauge. An unshielded
and single-Alter shielded (Fig. 2d) total precipitation gauge (TPG) were
provided by Sutron (Sutron, TPG, USA) and tested at the Marshall test bed
(Table 2). The Sutron TPG uses a load cell to quantify the amount of
accumulated precipitation, has a 914 mm capacity, an 8<inline-formula><mml:math id="M5" display="inline"><mml:msup><mml:mi/><mml:mrow><mml:mo>′</mml:mo><mml:mo>′</mml:mo></mml:mrow></mml:msup></mml:math></inline-formula> diameter inlet
(20.32 cm diameter, 324.3 cm<inline-formula><mml:math id="M6" display="inline"><mml:msup><mml:mi/><mml:mn mathvariant="normal">2</mml:mn></mml:msup></mml:math></inline-formula> area), and was provided with a heater
(Table 1). The T-200-MD3W (1500 mm Geonor) from Geonor (Geonor, Norway) was
tested at Marshall, Bratt's Lake, Weissfluhjoch, and Caribou Creek (Table 2),
but only the gauge at Weissfluhjoch was provided with a heater (Table 1). The
1500 mm Geonor is based on the same design as the 600 and 1000 mm Geonor
gauges, but it has a taller cover, taller
bucket with increased capacity, and different vibrating wire
transducers.</p>

<?xmltex \floatpos{p}?><table-wrap id="Ch1.T1" specific-use="star"><?xmltex \currentcnt{1}?><label>Table 1</label><caption><p id="d1e434">Gauge type, measurement type, heater power, output type, gauge
capacity, and the recorded rate of the different types of gauges included in
this evaluation. The recorded rate was determined by the logging system at a
given site, and was not intrinsic to the gauges. Test beds incorporated in
the study include the following: the Centre for Atmospheric Research
Experiments, Canada (CARE); Caribou Creek, Canada (CaCr); Bratt's Lake,
Canada (BrLa); Marshall, United States (Ma); Haukeliseter, Norway (Hauk); and
Weissfluhjoch, Switzerland (Weis). </p></caption><oasis:table frame="topbot"><oasis:tgroup cols="6">
     <oasis:colspec colnum="1" colname="col1" align="left"/>
     <oasis:colspec colnum="2" colname="col2" align="left"/>
     <oasis:colspec colnum="3" colname="col3" align="left"/>
     <oasis:colspec colnum="4" colname="col4" align="left"/>
     <oasis:colspec colnum="5" colname="col5" align="left"/>
     <oasis:colspec colnum="6" colname="col6" align="left"/>
     <oasis:thead>
       <oasis:row rowsep="1">
         <oasis:entry colname="col1">Gauge</oasis:entry>
         <oasis:entry colname="col2">Measurement</oasis:entry>
         <oasis:entry colname="col3">Heater</oasis:entry>
         <oasis:entry colname="col4">Output</oasis:entry>
         <oasis:entry colname="col5">Capacity</oasis:entry>
         <oasis:entry colname="col6">Recorded rate</oasis:entry>
       </oasis:row>
     </oasis:thead>
     <oasis:tbody>
       <oasis:row>
         <oasis:entry colname="col1">MPS Systém TRwS 405</oasis:entry>
         <oasis:entry colname="col2">Load cell</oasis:entry>
         <oasis:entry colname="col3">15 W</oasis:entry>
         <oasis:entry colname="col4">Digital</oasis:entry>
         <oasis:entry colname="col5">750 mm</oasis:entry>
         <oasis:entry colname="col6">1 min (Ma, Hauk)</oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1">Meteoservis MRW500</oasis:entry>
         <oasis:entry colname="col2">Load cell</oasis:entry>
         <oasis:entry colname="col3">350 W</oasis:entry>
         <oasis:entry colname="col4">Digital</oasis:entry>
         <oasis:entry colname="col5">900 mm</oasis:entry>
         <oasis:entry colname="col6">1 min (Ma, BrLa)</oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1">Sutron TPG</oasis:entry>
         <oasis:entry colname="col2">Load cell</oasis:entry>
         <oasis:entry colname="col3">200 W</oasis:entry>
         <oasis:entry colname="col4">Digital</oasis:entry>
         <oasis:entry colname="col5">914 mm</oasis:entry>
         <oasis:entry colname="col6">6 s (Ma)</oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1">1500 mm Geonor</oasis:entry>
         <oasis:entry colname="col2">Vibrating wire</oasis:entry>
         <oasis:entry colname="col3">60 W (Weis), N/A<inline-formula><mml:math id="M8" display="inline"><mml:msup><mml:mi/><mml:mo>*</mml:mo></mml:msup></mml:math></inline-formula></oasis:entry>
         <oasis:entry colname="col4">Analog</oasis:entry>
         <oasis:entry colname="col5">1500 mm</oasis:entry>
         <oasis:entry colname="col6">6 s (Ma, Weis),</oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1"/>
         <oasis:entry colname="col2"/>
         <oasis:entry colname="col3">(BrLa, CaCr, Ma)</oasis:entry>
         <oasis:entry colname="col4"/>
         <oasis:entry colname="col5"/>
         <oasis:entry colname="col6">1 min (BrLa, CaCr)</oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1">600 mm Geonor</oasis:entry>
         <oasis:entry colname="col2">Vibrating wire</oasis:entry>
         <oasis:entry colname="col3">60 W</oasis:entry>
         <oasis:entry colname="col4">Analog</oasis:entry>
         <oasis:entry colname="col5">600 mm</oasis:entry>
         <oasis:entry colname="col6">6 s (Ma)</oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1">OTT Pluvio<inline-formula><mml:math id="M9" display="inline"><mml:msup><mml:mi/><mml:mn mathvariant="normal">2</mml:mn></mml:msup></mml:math></inline-formula></oasis:entry>
         <oasis:entry colname="col2">Load cell</oasis:entry>
         <oasis:entry colname="col3">50 W</oasis:entry>
         <oasis:entry colname="col4">Digital</oasis:entry>
         <oasis:entry colname="col5">1500 mm</oasis:entry>
         <oasis:entry colname="col6">6 s (CARE)</oasis:entry>
       </oasis:row>
     </oasis:tbody>
   </oasis:tgroup></oasis:table><table-wrap-foot><p id="d1e437"><inline-formula><mml:math id="M7" display="inline"><mml:msup><mml:mi/><mml:mo>*</mml:mo></mml:msup></mml:math></inline-formula> The 1500 mm Geonor gauges at
Bratt's Lake, Caribou Creek, and Marshall were tested without heaters.</p></table-wrap-foot></table-wrap>

<?xmltex \floatpos{p}?><table-wrap id="Ch1.T2" specific-use="star"><?xmltex \currentcnt{2}?><label>Table 2</label><caption><p id="d1e664">Shield type, gauge type, test bed, mean and maximum (Max) of the
measured wind speed at gauge height (<inline-formula><mml:math id="M10" display="inline"><mml:mrow><mml:msub><mml:mi>U</mml:mi><mml:mi mathvariant="normal">gh</mml:mi></mml:msub><mml:mo>)</mml:mo></mml:mrow></mml:math></inline-formula>, and the number of liquid
(<inline-formula><mml:math id="M11" display="inline"><mml:mrow><mml:msub><mml:mi>N</mml:mi><mml:mi mathvariant="normal">liquid</mml:mi></mml:msub><mml:mo>)</mml:mo></mml:mrow></mml:math></inline-formula>, mixed (<inline-formula><mml:math id="M12" display="inline"><mml:mrow><mml:msub><mml:mi>N</mml:mi><mml:mi mathvariant="normal">mixd</mml:mi></mml:msub><mml:mo>)</mml:mo></mml:mrow></mml:math></inline-formula>, and solid
(<inline-formula><mml:math id="M13" display="inline"><mml:mrow><mml:msub><mml:mi>N</mml:mi><mml:mi mathvariant="normal">solid</mml:mi></mml:msub><mml:mo>)</mml:mo></mml:mrow></mml:math></inline-formula> 30 min precipitation measurements included in this
study. The measurements for all gauges were recorded during the two winter
seasons (1 October–30 April) of 2013–2015. Wind speed statistics only
describe periods of precipitation.</p></caption><oasis:table frame="topbot"><oasis:tgroup cols="8">
     <oasis:colspec colnum="1" colname="col1" align="left"/>
     <oasis:colspec colnum="2" colname="col2" align="left"/>
     <oasis:colspec colnum="3" colname="col3" align="left"/>
     <oasis:colspec colnum="4" colname="col4" align="left"/>
     <oasis:colspec colnum="5" colname="col5" align="left"/>
     <oasis:colspec colnum="6" colname="col6" align="right"/>
     <oasis:colspec colnum="7" colname="col7" align="right"/>
     <oasis:colspec colnum="8" colname="col8" align="right"/>
     <oasis:thead>
       <oasis:row rowsep="1">
         <oasis:entry colname="col1">Shield</oasis:entry>
         <oasis:entry colname="col2">Gauge</oasis:entry>
         <oasis:entry colname="col3">Test bed</oasis:entry>
         <oasis:entry colname="col4">Mean <italic>U</italic><inline-formula><mml:math id="M14" display="inline"><mml:msub><mml:mi/><mml:mi mathvariant="normal">gh</mml:mi></mml:msub></mml:math></inline-formula></oasis:entry>
         <oasis:entry colname="col5">Max <italic>U</italic><inline-formula><mml:math id="M15" display="inline"><mml:msub><mml:mi/><mml:mi mathvariant="normal">gh</mml:mi></mml:msub></mml:math></inline-formula></oasis:entry>
         <oasis:entry colname="col6"><italic>N</italic><inline-formula><mml:math id="M16" display="inline"><mml:msub><mml:mi/><mml:mi mathvariant="normal">liquid</mml:mi></mml:msub></mml:math></inline-formula></oasis:entry>
         <oasis:entry colname="col7"><italic>N</italic><inline-formula><mml:math id="M17" display="inline"><mml:msub><mml:mi/><mml:mi mathvariant="normal">mixd</mml:mi></mml:msub></mml:math></inline-formula></oasis:entry>
         <oasis:entry colname="col8"><italic>N</italic><inline-formula><mml:math id="M18" display="inline"><mml:msub><mml:mi/><mml:mi mathvariant="normal">solid</mml:mi></mml:msub></mml:math></inline-formula></oasis:entry>
       </oasis:row>
     </oasis:thead>
     <oasis:tbody>
       <oasis:row>
         <oasis:entry colname="col1">Unshielded</oasis:entry>
         <oasis:entry colname="col2">Sutron TPG</oasis:entry>
         <oasis:entry colname="col3">Ma</oasis:entry>
         <oasis:entry colname="col4">2.8 m s<inline-formula><mml:math id="M19" display="inline"><mml:msup><mml:mi/><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:msup></mml:math></inline-formula></oasis:entry>
         <oasis:entry colname="col5">10.2 m s<inline-formula><mml:math id="M20" display="inline"><mml:msup><mml:mi/><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:msup></mml:math></inline-formula></oasis:entry>
         <oasis:entry colname="col6">77</oasis:entry>
         <oasis:entry colname="col7">166</oasis:entry>
         <oasis:entry colname="col8">208</oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1">Unshielded</oasis:entry>
         <oasis:entry colname="col2">MRW500</oasis:entry>
         <oasis:entry colname="col3">Ma, BrLa</oasis:entry>
         <oasis:entry colname="col4">3.2 m s<inline-formula><mml:math id="M21" display="inline"><mml:msup><mml:mi/><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:msup></mml:math></inline-formula></oasis:entry>
         <oasis:entry colname="col5">10.2 m s<inline-formula><mml:math id="M22" display="inline"><mml:msup><mml:mi/><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:msup></mml:math></inline-formula></oasis:entry>
         <oasis:entry colname="col6">121</oasis:entry>
         <oasis:entry colname="col7">214</oasis:entry>
         <oasis:entry colname="col8">230</oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1">Unshielded</oasis:entry>
         <oasis:entry colname="col2">TRwS 405</oasis:entry>
         <oasis:entry colname="col3">Ma, Hauk</oasis:entry>
         <oasis:entry colname="col4">4.0 m s<inline-formula><mml:math id="M23" display="inline"><mml:msup><mml:mi/><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:msup></mml:math></inline-formula></oasis:entry>
         <oasis:entry colname="col5">17.0 m s<inline-formula><mml:math id="M24" display="inline"><mml:msup><mml:mi/><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:msup></mml:math></inline-formula></oasis:entry>
         <oasis:entry colname="col6">128</oasis:entry>
         <oasis:entry colname="col7">250</oasis:entry>
         <oasis:entry colname="col8">250</oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1">MRW500 shield</oasis:entry>
         <oasis:entry colname="col2">MRW500</oasis:entry>
         <oasis:entry colname="col3">Ma, BrLa</oasis:entry>
         <oasis:entry colname="col4">3.2 m s<inline-formula><mml:math id="M25" display="inline"><mml:msup><mml:mi/><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:msup></mml:math></inline-formula></oasis:entry>
         <oasis:entry colname="col5">10.2 m s<inline-formula><mml:math id="M26" display="inline"><mml:msup><mml:mi/><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:msup></mml:math></inline-formula></oasis:entry>
         <oasis:entry colname="col6">121</oasis:entry>
         <oasis:entry colname="col7">214</oasis:entry>
         <oasis:entry colname="col8">230</oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1">Single Alter</oasis:entry>
         <oasis:entry colname="col2">Sutron TPG</oasis:entry>
         <oasis:entry colname="col3">Ma</oasis:entry>
         <oasis:entry colname="col4">2.8 m s<inline-formula><mml:math id="M27" display="inline"><mml:msup><mml:mi/><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:msup></mml:math></inline-formula></oasis:entry>
         <oasis:entry colname="col5">10.2 m s<inline-formula><mml:math id="M28" display="inline"><mml:msup><mml:mi/><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:msup></mml:math></inline-formula></oasis:entry>
         <oasis:entry colname="col6">78</oasis:entry>
         <oasis:entry colname="col7">172</oasis:entry>
         <oasis:entry colname="col8">201</oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1">Single Alter</oasis:entry>
         <oasis:entry colname="col2">1500 mm Geonor</oasis:entry>
         <oasis:entry colname="col3">Ma, BrLa, Weis, CaCr</oasis:entry>
         <oasis:entry colname="col4">3.3 m s<inline-formula><mml:math id="M29" display="inline"><mml:msup><mml:mi/><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:msup></mml:math></inline-formula></oasis:entry>
         <oasis:entry colname="col5">11.6 m s<inline-formula><mml:math id="M30" display="inline"><mml:msup><mml:mi/><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:msup></mml:math></inline-formula></oasis:entry>
         <oasis:entry colname="col6">172</oasis:entry>
         <oasis:entry colname="col7">374</oasis:entry>
         <oasis:entry colname="col8">996</oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1">Double Alter</oasis:entry>
         <oasis:entry colname="col2">Geonor/Pluvio<inline-formula><mml:math id="M31" display="inline"><mml:msup><mml:mi/><mml:mn mathvariant="normal">2</mml:mn></mml:msup></mml:math></inline-formula></oasis:entry>
         <oasis:entry colname="col3">Ma, CARE</oasis:entry>
         <oasis:entry colname="col4">3.0 m s<inline-formula><mml:math id="M32" display="inline"><mml:msup><mml:mi/><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:msup></mml:math></inline-formula></oasis:entry>
         <oasis:entry colname="col5">10.2 m s<inline-formula><mml:math id="M33" display="inline"><mml:msup><mml:mi/><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:msup></mml:math></inline-formula></oasis:entry>
         <oasis:entry colname="col6">147</oasis:entry>
         <oasis:entry colname="col7">173</oasis:entry>
         <oasis:entry colname="col8">403</oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1">Belfort double Alter</oasis:entry>
         <oasis:entry colname="col2">Geonor/Pluvio<inline-formula><mml:math id="M34" display="inline"><mml:msup><mml:mi/><mml:mn mathvariant="normal">2</mml:mn></mml:msup></mml:math></inline-formula></oasis:entry>
         <oasis:entry colname="col3">Ma, CARE</oasis:entry>
         <oasis:entry colname="col4">3.0 m s<inline-formula><mml:math id="M35" display="inline"><mml:msup><mml:mi/><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:msup></mml:math></inline-formula></oasis:entry>
         <oasis:entry colname="col5">10.2 m s<inline-formula><mml:math id="M36" display="inline"><mml:msup><mml:mi/><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:msup></mml:math></inline-formula></oasis:entry>
         <oasis:entry colname="col6">206</oasis:entry>
         <oasis:entry colname="col7">244</oasis:entry>
         <oasis:entry colname="col8">496</oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1">SDFIR</oasis:entry>
         <oasis:entry colname="col2">Geonor</oasis:entry>
         <oasis:entry colname="col3">Ma</oasis:entry>
         <oasis:entry colname="col4">2.9 m s<inline-formula><mml:math id="M37" display="inline"><mml:msup><mml:mi/><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:msup></mml:math></inline-formula></oasis:entry>
         <oasis:entry colname="col5">10.2 m s<inline-formula><mml:math id="M38" display="inline"><mml:msup><mml:mi/><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:msup></mml:math></inline-formula></oasis:entry>
         <oasis:entry colname="col6">76</oasis:entry>
         <oasis:entry colname="col7">173</oasis:entry>
         <oasis:entry colname="col8">161</oasis:entry>
       </oasis:row>
     </oasis:tbody>
   </oasis:tgroup></oasis:table></table-wrap>

      <?xmltex \floatpos{p}?><fig id="Ch1.F2" specific-use="star"><?xmltex \currentcnt{2}?><label>Figure 2</label><caption><p id="d1e1291">Photos of the <bold>(a)</bold> TRwS 405, <bold>(b)</bold> unshielded MRW500,
<bold>(c)</bold> shielded MRW500, <bold>(d)</bold> single-Alter shielded Sutron,
<bold>(e)</bold> double-Alter shielded Geonor, <bold>(f)</bold> Belfort double-Alter
shielded Geonor, and <bold>(g)</bold> SDFIR-shielded Geonor at the Marshall, CO,
US test bed.</p></caption>
          <?xmltex \igopts{width=398.338583pt}?><graphic xlink:href="https://hess.copernicus.org/articles/22/1437/2018/hess-22-1437-2018-f02.png"/>

        </fig>

      <?pagebreak page1442?><p id="d1e1322">The double-Alter shield (Fig. 2d), which consists of a single-Alter shield
surrounded by a second, larger (2.4 m in diameter) row of 40 cm long slats,
was tested at CARE (Centre for Atmospheric Research Experiments) with an OTT
Pluvio<inline-formula><mml:math id="M39" display="inline"><mml:msup><mml:mi/><mml:mn mathvariant="normal">2</mml:mn></mml:msup></mml:math></inline-formula> (OTT Hydromet, Pluvio<inline-formula><mml:math id="M40" display="inline"><mml:msup><mml:mi/><mml:mn mathvariant="normal">2</mml:mn></mml:msup></mml:math></inline-formula>, Germany; Tables 1 and 2) and at
Marshall with a Geonor T-200B3 (three-wire, 600 mm capacity, T200B, Geonor Inc.,
Norway; Tables 1 and 2). Both gauges included inlet heating, with the
Pluvio<inline-formula><mml:math id="M41" display="inline"><mml:msup><mml:mi/><mml:mn mathvariant="normal">2</mml:mn></mml:msup></mml:math></inline-formula> at CARE using the manufacturer-provided heater and the Geonor
at Marshall using the US Climate Reference Network heater (described in NOAA
Technical Note NCDC No. USCRN-04-01). Based on the additional shielding
provided by the double-Alter shield and also past studies (K2017b), the
double-Alter shield is expected to perform better than the single-Alter
shield (reduced undercatch), and to accumulate greater than 50 % of the
DFAR accumulation even in snowy and windy conditions. The Belfort
double-Alter shield (Fig. 2f), which has the same sized footprint as the
standard double-Alter shield, but with a lower porosity (30 % vs. the
standard double-Alter porosity of 50 %) and longer slats (46 cm long for
the inner shield and 61 cm long for the outer shield) that do not taper like
the double-Alter slats, was also tested at both CARE and Marshall (Table 2).
The standard double-Alter slats also rotate freely, while the Belfort
double-Alter slats employ springs to limit their travel within 30<inline-formula><mml:math id="M42" display="inline"><mml:msup><mml:mi/><mml:mo>∘</mml:mo></mml:msup></mml:math></inline-formula>
of the vertical. Like the standard double-Alter, the Belfort double-Alter
was tested with a Pluvio<inline-formula><mml:math id="M43" display="inline"><mml:msup><mml:mi/><mml:mn mathvariant="normal">2</mml:mn></mml:msup></mml:math></inline-formula> at CARE and a 600 mm Geonor T-200B3 at
Marshall (Table 2). Prior to this research, this shield had only been evaluated
at the Marshall test bed (K2017b). Based on that study, gauges within this
shield are expected to accumulate almost as much precipitation as the DFAR,
with typical catch efficiencies greater than 0.8 in snowy and windy
conditions.</p>
      <p id="d1e1370">The SDFIR shield (Fig. 2g), which is <inline-formula><mml:math id="M44" display="inline"><mml:mrow><mml:mn mathvariant="normal">2</mml:mn><mml:mo>/</mml:mo><mml:mn mathvariant="normal">3</mml:mn></mml:mrow></mml:math></inline-formula> the size of standard DFIR shield
and was designed to be more easily constructed out of commonly sized North
American lumber, was tested only at the Marshall site (Table 2). Like the
standard DFIR shield, the SDFIR comprises three concentric shields. The
wooden laths on the two-outermost concentric shields were 1.2 m long,
and the diameters of the two outer shields were 8.0 and 2.6 m.
The height of the inner wooden shield was 10 cm lower than the outer shield.
A standard single-Alter shield, mounted at the same height as the gauge
inlet and 10 cm lower than the inner wooden shield, was mounted around the
gauge. Based on its design and a past study (K2017b), we expect this shield
to be almost indistinguishable from the DFAR, except in high winds and snowy
conditions, where it will typically accumulate about 90 % as much
precipitation as the DFAR.</p>
</sec>
<sec id="Ch1.S2.SS3">
  <label>2.3</label><title>Wind speed and direction</title>
      <p id="d1e1393">Wind speed measurements were used to create 30 min-average wind speeds
for each site. Because transfer functions developed from wind speeds at the gauge
height and wind speeds at a height of 10 m were desired, and not every site
included wind measurements at both heights; the available 30 min
measurements and the logarithmic wind profile were used to determine either
the gauge height or 10 m height wind speeds, when necessary. These methods
are described in detail in K2017a. For the TRwS 405 precipitation gauge at
Haukeliseter, an additional screening for wind direction was performed based
on the gauge's position relative to the DFAR; precipitation measurements
with wind directions between 115 and 140<inline-formula><mml:math id="M45" display="inline"><mml:msup><mml:mi/><mml:mo>∘</mml:mo></mml:msup></mml:math></inline-formula> were excluded
from the analysis due to wind shielding by the DFAR.</p>
</sec>
<sec id="Ch1.S2.SS4">
  <label>2.4</label><?xmltex \opttitle{Quality control and selection of 30\,min periods of precipitation}?><title>Quality control and selection of 30 min periods of precipitation</title>
      <p id="d1e1414">Precipitation measurements were recorded at either 6 s or 1 min intervals
(Table 1). These 6 s and 1 min data were subject to the following quality
controls: a range filter, to remove values that exceeded the capacity of the
gauge; a “jump” filter, to remove sudden changes in accumulation exceeding a
specified threshold; and a Gaussian filter, to remove high-frequency noise.
For transfer function development, the resultant 1 min (all 6 s data were
aggregated to 1 min), quality-controlled measurements were then used to
create 30 min datasets that included only periods of precipitation. To
exclude noise and light precipitation, a minimum threshold of 0.25 mm of
precipitation as measured by the DFAR was used. In addition, based on
independent optical precipitation detector measurements, precipitation had
to occur for at least 60 % of every 30 min period (18 min). More detailed
descriptions of the quality control methods developed and employed in
WMO-SPICE are detailed elsewhere (K2017a; Reverdin, 2016).</p>
      <p id="d1e1417">Following K2017a, a minimum precipitation accumulation threshold for 30 min
intervals was identified for every gauge or shield under evaluation to help
create an unbiased pool of measurements available for analysis. All 30 min
precipitation measurements below the minimum threshold determined for each
specific gauge/shield configuration were excluded from the analysis. The
minimum precipitation thresholds were calculated by multiplying the minimum
DFAR precipitation of 0.25 mm by the median catch efficiency of the gauge
under test (for 30 min intervals), using only solid precipitation
measurements (mean <inline-formula><mml:math id="M46" display="inline"><mml:mrow><mml:msub><mml:mi>T</mml:mi><mml:mi mathvariant="normal">air</mml:mi></mml:msub><mml:mi mathvariant="italic">&lt;</mml:mi><mml:mo>-</mml:mo><mml:mn mathvariant="normal">2</mml:mn></mml:mrow></mml:math></inline-formula> <inline-formula><mml:math id="M47" display="inline"><mml:msup><mml:mi/><mml:mo>∘</mml:mo></mml:msup></mml:math></inline-formula>C) with high winds (5 m s<inline-formula><mml:math id="M48" display="inline"><mml:msup><mml:mi/><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:msup></mml:math></inline-formula> &lt;<inline-formula><mml:math id="M49" display="inline"><mml:mrow><mml:msub><mml:mi>U</mml:mi><mml:mrow><mml:mn mathvariant="normal">10</mml:mn><mml:mspace linebreak="nobreak" width="0.125em"/><mml:mi mathvariant="normal">m</mml:mi></mml:mrow></mml:msub><mml:mi mathvariant="italic">&lt;</mml:mi><mml:mn mathvariant="normal">9</mml:mn></mml:mrow></mml:math></inline-formula> m s<inline-formula><mml:math id="M50" display="inline"><mml:mrow><mml:msup><mml:mi/><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:msup><mml:mo>)</mml:mo></mml:mrow></mml:math></inline-formula>. Also following K2017a,
a maximum catch efficiency threshold was calculated as 1.0 plus three times
the standard deviation of the catch efficiency of the gauge under test, and
all measurements exceeding the relevant maximum catch efficiency threshold
were excluded from the analysis.</p>
</sec>
<sec id="Ch1.S2.SS5">
  <label>2.5</label><title>Transfer function models</title>
      <p id="d1e1501">Equation (1) was fit to the quality-controlled 30 min weighing gauge
measurements, following K2017a:
            <disp-formula id="Ch1.E1" content-type="numbered"><label>1</label><mml:math id="M51" display="block"><mml:mrow><mml:mi mathvariant="normal">CE</mml:mi><mml:mo>=</mml:mo><mml:msup><mml:mi>e</mml:mi><mml:mrow><mml:mo>-</mml:mo><mml:mi>a</mml:mi><mml:mfenced close=")" open="("><mml:mi>U</mml:mi></mml:mfenced><mml:mfenced open="(" close=")"><mml:mrow><mml:mn mathvariant="normal">1</mml:mn><mml:mo>-</mml:mo><mml:msup><mml:mi>tan⁡</mml:mi><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:msup><mml:mfenced open="(" close=")"><mml:mrow><mml:mi>b</mml:mi><mml:mfenced close=")" open="("><mml:mrow><mml:msub><mml:mi>T</mml:mi><mml:mi mathvariant="normal">air</mml:mi></mml:msub></mml:mrow></mml:mfenced></mml:mrow></mml:mfenced><mml:mo>+</mml:mo><mml:mi>c</mml:mi></mml:mrow></mml:mfenced><mml:mo>,</mml:mo></mml:mrow></mml:msup></mml:mrow></mml:math></disp-formula>
          where CE is the catch efficiency, <inline-formula><mml:math id="M52" display="inline"><mml:mi>U</mml:mi></mml:math></inline-formula> is the mean wind speed, <inline-formula><mml:math id="M53" display="inline"><mml:mrow><mml:msub><mml:mi>T</mml:mi><mml:mi mathvariant="normal">air</mml:mi></mml:msub></mml:mrow></mml:math></inline-formula> is the
mean air temperature, and <inline-formula><mml:math id="M54" display="inline"><mml:mi>a</mml:mi></mml:math></inline-formula>, <inline-formula><mml:math id="M55" display="inline"><mml:mi>b</mml:mi></mml:math></inline-formula>, and <inline-formula><mml:math id="M56" display="inline"><mml:mi>c</mml:mi></mml:math></inline-formula> are coefficients fit to the data.
Equation (2) was also fit to the precipitation measurements, following K2017a:
            <disp-formula id="Ch1.E2" content-type="numbered"><label>2</label><mml:math id="M57" display="block"><mml:mrow><mml:mi mathvariant="normal">CE</mml:mi><mml:mo>=</mml:mo><mml:mo>(</mml:mo><mml:mi>a</mml:mi><mml:mo>)</mml:mo><mml:msup><mml:mi>e</mml:mi><mml:mrow><mml:mo>-</mml:mo><mml:mi>b</mml:mi><mml:mfenced open="(" close=")"><mml:mi>U</mml:mi></mml:mfenced><mml:mspace width="0.125em" linebreak="nobreak"/></mml:mrow></mml:msup><mml:mo>+</mml:mo><mml:mi>c</mml:mi><mml:mo>,</mml:mo></mml:mrow></mml:math></disp-formula>
          where <inline-formula><mml:math id="M58" display="inline"><mml:mi>a</mml:mi></mml:math></inline-formula>, <inline-formula><mml:math id="M59" display="inline"><mml:mi>b</mml:mi></mml:math></inline-formula>, and <inline-formula><mml:math id="M60" display="inline"><mml:mi>c</mml:mi></mml:math></inline-formula> are coefficients fit to the data. Equation (1) was fit as a
function of wind speed and air temperature, while Eq. (2) was fit
separately to solid and mixed precipitation measurements as a function of
wind speed only. In the latter case, precipitation type was determined using
air temperature, with solid precipitation defined as <inline-formula><mml:math id="M61" display="inline"><mml:mrow><mml:msub><mml:mi>T</mml:mi><mml:mi mathvariant="normal">air</mml:mi></mml:msub><mml:mi mathvariant="italic">&lt;</mml:mi><mml:mspace width="0.125em" linebreak="nobreak"/><mml:mo>-</mml:mo><mml:mn mathvariant="normal">2</mml:mn></mml:mrow></mml:math></inline-formula> <inline-formula><mml:math id="M62" display="inline"><mml:msup><mml:mi/><mml:mo>∘</mml:mo></mml:msup></mml:math></inline-formula>C, and mixed defined as
2 <inline-formula><mml:math id="M63" display="inline"><mml:msup><mml:mi/><mml:mo>∘</mml:mo></mml:msup></mml:math></inline-formula>C <inline-formula><mml:math id="M64" display="inline"><mml:mrow><mml:mo>≥</mml:mo><mml:msub><mml:mi>T</mml:mi><mml:mi mathvariant="normal">air</mml:mi></mml:msub><mml:mo>≥</mml:mo></mml:mrow></mml:math></inline-formula> <inline-formula><mml:math id="M65" display="inline"><mml:mo>-</mml:mo></mml:math></inline-formula>2 <inline-formula><mml:math id="M66" display="inline"><mml:msup><mml:mi/><mml:mo>∘</mml:mo></mml:msup></mml:math></inline-formula>C. These specific temperature thresholds were selected to
estimate precipitation type based on past evaluations of precipitation type
and air temperature (K2017b, Wolff et al., 2015). For some of
the gauges examined here, Eq. (2) unrealistically over-predicted catch
efficiency at low wind speeds when insufficiently constrained by the
available measurements, and in these cases a more constrained function was
used to describe realistic<?pagebreak page1443?> corrections for gauges with fewer low wind speed
measurements:
            <disp-formula id="Ch1.E3" content-type="numbered"><label>3</label><mml:math id="M67" display="block"><mml:mrow><mml:mi mathvariant="normal">CE</mml:mi><mml:mo>=</mml:mo><mml:mo>(</mml:mo><mml:mi>a</mml:mi><mml:mo>)</mml:mo><mml:msup><mml:mi>e</mml:mi><mml:mrow><mml:mo>-</mml:mo><mml:mi>b</mml:mi><mml:mfenced close=")" open="("><mml:mi>U</mml:mi></mml:mfenced></mml:mrow></mml:msup><mml:mo>+</mml:mo><mml:mo>(</mml:mo><mml:mn mathvariant="normal">1</mml:mn><mml:mo>-</mml:mo><mml:mi>a</mml:mi><mml:mo>)</mml:mo><mml:mo>,</mml:mo></mml:mrow></mml:math></disp-formula>
          where <inline-formula><mml:math id="M68" display="inline"><mml:mi>a</mml:mi></mml:math></inline-formula>, and <inline-formula><mml:math id="M69" display="inline"><mml:mi>b</mml:mi></mml:math></inline-formula> are coefficients fit to the data. Following K2017a, transfer
functions were developed for both gauge height and 10 m height wind speeds.</p>
</sec>
<sec id="Ch1.S2.SS6">
  <label>2.6</label><title>Maximum wind speed threshold</title>
      <p id="d1e1784">For the application of transfer functions, a maximum wind speed threshold
(<inline-formula><mml:math id="M70" display="inline"><mml:mrow><mml:msub><mml:mi>U</mml:mi><mml:mi mathvariant="normal">thresh</mml:mi></mml:msub><mml:mo>)</mml:mo></mml:mrow></mml:math></inline-formula> above which the transfer function should not be applied was
determined based on a visual assessment of the Eq. (1) transfer function fit
to the available measurements. This was done by viewing the catch efficiency
function of wind speed and air temperature superimposed on the measurement
data, and identifying the wind speed above which all temperature ranges
below 2 <inline-formula><mml:math id="M71" display="inline"><mml:msup><mml:mi/><mml:mo>∘</mml:mo></mml:msup></mml:math></inline-formula>C were not generally well represented by the available
measurements. The same threshold was applied to the Eq. (2) and Eq. (3) transfer
functions. In practice, when the wind speed is above the maximum wind speed
threshold, the wind speed should be forced down to the maximum wind speed
threshold to adjust the precipitation. A diagram describing the effects of
the maximum wind speed threshold on an example transfer function is shown in
Fig. 3, using the unshielded Eq. (2) type transfer function developed in
K2017a.</p>
</sec>
<sec id="Ch1.S2.SS7">
  <label>2.7</label><title>Testing of transfer functions</title>
      <p id="d1e1817">When measurements from more than one site were available for a specific
gauge or shield, all of the available measurements were merged to create a
common transfer function, and the transfer function was then tested on data
from each site independently to determine the magnitude of site biases and
the appropriateness of the transfer function for each individual site. For
gauges that were only tested at one site, a 10-fold cross validation was
relied upon to maintain some independence between the measurements used to
produce and test the transfer functions. The 10-fold cross validation was
performed in 10 separate iterations, each using 90 % of the measurements
to determine the transfer function and the remaining 10 % to test the
transfer function. The resulting error statistics were based on the average
of all 10 iterations.</p>

      <?xmltex \floatpos{t}?><fig id="Ch1.F3"><?xmltex \currentcnt{3}?><label>Figure 3</label><caption><p id="d1e1822">Example application of the maximum wind speed threshold
(<inline-formula><mml:math id="M72" display="inline"><mml:mrow><mml:msub><mml:mi>U</mml:mi><mml:mi mathvariant="normal">thresh</mml:mi></mml:msub><mml:mo>)</mml:mo></mml:mrow></mml:math></inline-formula>, using an Eq. (2) type transfer function describing
unshielded (UN) solid precipitation catch efficiency (CE) from K2017a. At
wind speeds exceeding <inline-formula><mml:math id="M73" display="inline"><mml:mrow><mml:msub><mml:mi>U</mml:mi><mml:mi mathvariant="normal">thresh</mml:mi></mml:msub></mml:mrow></mml:math></inline-formula> (7.2 m s<inline-formula><mml:math id="M74" display="inline"><mml:msup><mml:mi/><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:msup></mml:math></inline-formula> in this case) the
catch efficiency is fixed at the value determined at <inline-formula><mml:math id="M75" display="inline"><mml:mrow><mml:msub><mml:mi>U</mml:mi><mml:mi mathvariant="normal">thresh</mml:mi></mml:msub></mml:mrow></mml:math></inline-formula>.</p></caption>
          <?xmltex \igopts{width=236.157874pt}?><graphic xlink:href="https://hess.copernicus.org/articles/22/1437/2018/hess-22-1437-2018-f03.png"/>

        </fig>

      <p id="d1e1878">Errors in the adjusted measurements were estimated by applying the
appropriate transfer function and comparing the results to the corresponding
DFAR measurements. The errors were then used to calculate the root mean
square error (RMSE), the mean bias, the correlation coefficient <inline-formula><mml:math id="M76" display="inline"><mml:mrow><mml:mo>(</mml:mo><mml:mi>r</mml:mi><mml:mo>)</mml:mo></mml:mrow></mml:math></inline-formula>, and the
percentage of 30 min events with errors less than 0.1 mm (PE<inline-formula><mml:math id="M77" display="inline"><mml:mrow><mml:msub><mml:mi/><mml:mrow><mml:mn mathvariant="normal">0.1</mml:mn><mml:mspace linebreak="nobreak" width="0.125em"/><mml:mi mathvariant="normal">mm</mml:mi></mml:mrow></mml:msub><mml:mo>)</mml:mo></mml:mrow></mml:math></inline-formula>.
These statistics were estimated for the Eq. (1) transfer functions using all
of the available precipitation measurements. Following K2017a, the Eq. (2) and
Eq. (3) transfer function error statistics were estimated by separating the
datasets using the mean air temperature into liquid (<inline-formula><mml:math id="M78" display="inline"><mml:mrow><mml:msub><mml:mi>T</mml:mi><mml:mi mathvariant="normal">air</mml:mi></mml:msub><mml:mi mathvariant="italic">&gt;</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:mrow></mml:math></inline-formula> <inline-formula><mml:math id="M79" display="inline"><mml:msup><mml:mi/><mml:mo>∘</mml:mo></mml:msup></mml:math></inline-formula>C), mixed (2 <inline-formula><mml:math id="M80" display="inline"><mml:msup><mml:mi/><mml:mo>∘</mml:mo></mml:msup></mml:math></inline-formula>C <inline-formula><mml:math id="M81" display="inline"><mml:mrow><mml:mo>≥</mml:mo><mml:msub><mml:mi>T</mml:mi><mml:mi mathvariant="normal">air</mml:mi></mml:msub><mml:mo>≥</mml:mo><mml:mo>-</mml:mo><mml:mn mathvariant="normal">2</mml:mn></mml:mrow></mml:math></inline-formula> <inline-formula><mml:math id="M82" display="inline"><mml:msup><mml:mi/><mml:mo>∘</mml:mo></mml:msup></mml:math></inline-formula>C.),
and solid (<inline-formula><mml:math id="M83" display="inline"><mml:mrow><mml:msub><mml:mi>T</mml:mi><mml:mi mathvariant="normal">air</mml:mi></mml:msub><mml:mi mathvariant="italic">&lt;</mml:mi><mml:mo>-</mml:mo><mml:mn mathvariant="normal">2</mml:mn></mml:mrow></mml:math></inline-formula> <inline-formula><mml:math id="M84" display="inline"><mml:msup><mml:mi/><mml:mo>∘</mml:mo></mml:msup></mml:math></inline-formula>C) precipitation,
correcting the mixed and solid precipitation using the appropriate transfer
functions, combining these results with the uncorrected liquid precipitation
measurements, and comparing the results to the corresponding DFAR
measurements.</p>
      <p id="d1e1998">A <inline-formula><mml:math id="M85" display="inline"><mml:mi>t</mml:mi></mml:math></inline-formula> test with a significance level of 5 % was used to evaluate the
significance of differences among results adjusted using different transfer
functions. When a given precipitation gauge/shield configuration was tested
at more than one site, the adjusted measurements from all of the available
sites were pooled together before determining the significance of adjusted
measurement differences. The same test was also used to compare unadjusted
measurements to adjusted measurements.</p>
</sec>
<sec id="Ch1.S2.SS8">
  <label>2.8</label><title>Evaluation of independent transfer functions</title>
      <p id="d1e2016">In addition to developing new adjustments for the manufacturer-provided
weighing gauges tested in WMO-SPICE, the WMO-SPICE weighing gauge
measurements were also used to evaluate other independently derived transfer
functions that were available. These include the WMO-SPICE single-Alter
shielded and unshielded transfer functions derived using eight different
test beds (K2017a), and transfer functions determined from pre-SPICE
measurements recorded at the Marshall test bed within larger windshields
(K2017b).</p>
      <p id="d1e2019">Single-Alter and unshielded transfer functions developed previously for
WMO-SPICE host-provided weighing gauges (either Geonor T-200B3 or OTT
Pluvio<inline-formula><mml:math id="M86" display="inline"><mml:msup><mml:mi/><mml:mn mathvariant="normal">2</mml:mn></mml:msup></mml:math></inline-formula>; K2017a) were tested on measurements from all of the
manufacturer-provided unshielded and single-Alter shielded gauges.<?pagebreak page1444?> The
hypothesis behind this testing is that the response of a gauge to wind speed
and air temperature is more sensitive to wind-shielding (or lack thereof)
than to the specific gauge type. Although the transfer functions from K2017a
were not developed for these specific gauges, they include measurements from
eight different sites. Therefore, they may be more robust and universally
applicable than transfer functions developed from measurements at the
limited number of sites, where a specific manufacturer-provided gauge was
tested. A robust transfer function should arguably be developed from
measurements representing a wide variety of precipitation types and wind
speeds, as any transfer function is only valid for the range of conditions
represented by the measurements used in its development. In addition, as
shown in K2017a, site biases do exist, indicating that the use of data from
several sites for the creation of a transfer function is preferable to the
use of data from just one or two sites. Because of this, it is possible that
a generic transfer function developed using data from several sites may be
more universally applicable to a manufacturer-provided weighing gauge than
the gauge-specific transfer function. For the double-Alter, Belfort
double-Alter, and the SDFIR shielded gauges, which were not tested as
broadly within WMO-SPICE as the single-Alter shielded and unshielded gauges,
the WMO-SPICE measurements recorded at Marshall and CARE were used to
evaluate transfer functions created in K2017b using measurements recorded at
the Marshall test bed before WMO-SPICE began.</p>
</sec>
<sec id="Ch1.S2.SS9">
  <label>2.9</label><title>Transfer function uncertainty and wind speed</title>
      <p id="d1e2039">Errors in the transfer functions were evaluated further as a function of
wind speed by computing RMSE values from the available catch efficiencies
after binning by wind speed (1 m s<inline-formula><mml:math id="M87" display="inline"><mml:msup><mml:mi/><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:msup></mml:math></inline-formula> bins). For each wind speed bin,
the RMSE values of the adjustments were calculated from differences between
the transfer function catch efficiencies and the measured catch
efficiencies. In addition, RMSE values of the adjusted catch efficiencies
were estimated by applying the appropriate transfer function to the
measurements and calculating the resultant error in the catch efficiency.
This evaluation was limited to solid precipitation (<inline-formula><mml:math id="M88" display="inline"><mml:mrow><mml:msub><mml:mi>T</mml:mi><mml:mi mathvariant="normal">air</mml:mi></mml:msub><mml:mi mathvariant="italic">&lt;</mml:mi><mml:mo>-</mml:mo><mml:mn mathvariant="normal">2</mml:mn></mml:mrow></mml:math></inline-formula> <inline-formula><mml:math id="M89" display="inline"><mml:msup><mml:mi/><mml:mo>∘</mml:mo></mml:msup></mml:math></inline-formula>C) measurements for ease of presentation, and the Eq. (1) type
transfer functions were used for all of the gauge configurations examined.</p>
</sec>
</sec>
<sec id="Ch1.S3">
  <label>3</label><title>Results and discussion</title>
<sec id="Ch1.S3.SS1">
  <label>3.1</label><title>Transfer function types</title>
      <p id="d1e2096">Using the methods described above, custom transfer functions were created
for all manufacturer-provided weighing gauges and all shield configurations
tested in WMO-SPICE (Table 2). For all of the gauges and shields tested, the
Eq. (1) transfer function was fit to the calculated catch efficiency values
using the measured wind speed and air temperature. In addition, either the
Eq. (2) or the Eq. (3) type adjustment was fit to the mixed (2 <inline-formula><mml:math id="M90" display="inline"><mml:msup><mml:mi/><mml:mo>∘</mml:mo></mml:msup></mml:math></inline-formula>C <inline-formula><mml:math id="M91" display="inline"><mml:mrow><mml:mo>≥</mml:mo><mml:mspace linebreak="nobreak" width="0.125em"/><mml:msub><mml:mi>T</mml:mi><mml:mi mathvariant="normal">air</mml:mi></mml:msub><mml:mo>≥</mml:mo><mml:mo>-</mml:mo><mml:mn mathvariant="normal">2</mml:mn></mml:mrow></mml:math></inline-formula> <inline-formula><mml:math id="M92" display="inline"><mml:msup><mml:mi/><mml:mo>∘</mml:mo></mml:msup></mml:math></inline-formula>C) and
solid (<inline-formula><mml:math id="M93" display="inline"><mml:mrow><mml:msub><mml:mi>T</mml:mi><mml:mi mathvariant="normal">air</mml:mi></mml:msub><mml:mi mathvariant="italic">&lt;</mml:mi><mml:mo>-</mml:mo><mml:mn mathvariant="normal">2</mml:mn></mml:mrow></mml:math></inline-formula> <inline-formula><mml:math id="M94" display="inline"><mml:msup><mml:mi/><mml:mo>∘</mml:mo></mml:msup></mml:math></inline-formula>C) precipitation measurements as a function of wind speed. These
transfer functions were created for both the gauge height wind speed and the
10 m height wind speed. Statistics describing the transfer function errors
were calculated based on the differences between the adjusted precipitation
measurements and the DFAR precipitation measurements. In addition, transfer
functions available from other studies were tested on these precipitation
measurements, and errors in the uncorrected measurements were also
described.</p>
      <p id="d1e2163">Based on the results of <inline-formula><mml:math id="M95" display="inline"><mml:mi>t</mml:mi></mml:math></inline-formula> tests used to compare different types of transfer
functions, no significant differences were found among measurements adjusted
using the Eq. (1), Eq. (2), or Eq. (3) transfer functions. In addition, there were
no significant differences between measurements adjusted using the 10 m
height wind speeds or the gauge height wind speeds. For the sake of
simplicity, and to focus on more significant results, a comparison of
results for all transfer functions, for each gauge and shield tested, is not
included here. Examples of such comparisons are available in K2017a, and
like the present study, these examples demonstrate that the different types
of transfer functions fitted to the same data performed similarly. Newly
developed and previously existing transfer functions are, therefore,
compared using Eq. (1) transfer functions with gauge height winds, with these
results found to be representative of all of the different types of transfer
functions tested.</p>

      <?xmltex \floatpos{t}?><fig id="Ch1.F4"><?xmltex \currentcnt{4}?><label>Figure 4</label><caption><p id="d1e2175"><bold>(a)</bold> Root mean square error (RMSE), <bold>(b)</bold> bias,
<bold>(c)</bold> correlation coefficient (<inline-formula><mml:math id="M96" display="inline"><mml:mrow><mml:mi>r</mml:mi><mml:mo>)</mml:mo></mml:mrow></mml:math></inline-formula>, and <bold>(d)</bold> the percentage
of events with errors less than 0.1 mm (PE<inline-formula><mml:math id="M97" display="inline"><mml:mrow><mml:msub><mml:mi/><mml:mrow><mml:mn mathvariant="normal">0.1</mml:mn><mml:mspace linebreak="nobreak" width="0.125em"/><mml:mi mathvariant="normal">mm</mml:mi></mml:mrow></mml:msub><mml:mo>)</mml:mo></mml:mrow></mml:math></inline-formula> calculated from
the difference between the 30 min precipitation measurements from the
corrected, unshielded gauges and the DFAR. The Sutron from Marshall (Ma Sut),
the MRW500 from Marshall (Ma MRW500) and Bratt's Lake (BrLa MRW500), and the
TRwS 405 from Marshall (Ma TRWS) and Haukeliseter (Hauk TRWS) are included.
Uncorrected measurements are also shown (uncorrected – dark blue).
Measurements adjusted using an example transfer function (Eq. 1) fit to
precipitation, air temperature (<inline-formula><mml:math id="M98" display="inline"><mml:mrow><mml:msub><mml:mi>T</mml:mi><mml:mi mathvariant="normal">air</mml:mi></mml:msub><mml:mo>)</mml:mo></mml:mrow></mml:math></inline-formula> and gauge height wind speed
(<inline-formula><mml:math id="M99" display="inline"><mml:mrow><mml:msub><mml:mi>U</mml:mi><mml:mi mathvariant="normal">gh</mml:mi></mml:msub><mml:mo>)</mml:mo></mml:mrow></mml:math></inline-formula> are shown in green. Statistics describing these
measurements adjusted using the “universal” unshielded transfer function
(Univ. Eq. 1 – yellow), which were based on independent Eq. (1) coefficients
derived in K2017a, are also shown.</p></caption>
          <?xmltex \igopts{width=236.157874pt}?><graphic xlink:href="https://hess.copernicus.org/articles/22/1437/2018/hess-22-1437-2018-f04.png"/>

        </fig>

      <?xmltex \floatpos{t}?><fig id="Ch1.F5" specific-use="star"><?xmltex \currentcnt{5}?><label>Figure 5</label><caption><p id="d1e2251">Error statistics calculated for the single-Alter shielded Marshall
Sutron gauge (Ma Sut) and single-Alter shielded 1500 mm Geonor gauges
(Geon15) at the Marshall (Ma), Bratt's Lake (BrLa), Weissfluhjoch (Weis), and
Caribou Creek (CaCr) test beds <bold>(a–d)</bold>. Error statistics from the
shielded MRW500 gauges from Marshall (Ma MRW500) and Bratt's Lake (BrLa
MRW500) are also shown <bold>(e–h)</bold>. The different statistics and
correction types are described in the Fig. 4 caption. The results of the
“universal” single-Alter transfer function (Univ. Eq. 1 – yellow), which
were based on independent Eq. (1) coefficients derived in K2017a, are shown
for all of the single-Alter shielded gauges and also for the gauges within
the MRW500 shield.</p></caption>
          <?xmltex \igopts{width=341.433071pt}?><graphic xlink:href="https://hess.copernicus.org/articles/22/1437/2018/hess-22-1437-2018-f05.png"/>

        </fig>

</sec>
<sec id="Ch1.S3.SS2">
  <label>3.2</label><title>Unshielded gauges</title>
      <p id="d1e2274">Unshielded Sutron, MRW500, and TRwS 405 weighing gauges were tested at
several different WMO-SPICE test beds. Separate transfer functions were
developed for each gauge type. In addition, an independent pre-existing
“universal” transfer function (K2017a) was tested on all of the unshielded
gauge measurements. Statistics describing errors in the adjusted and
unadjusted measurements are shown in Fig. 4. Improvements in the adjusted
bias (Fig. 4b) and PE<inline-formula><mml:math id="M100" display="inline"><mml:msub><mml:mi/><mml:mrow><mml:mn mathvariant="normal">0.1</mml:mn><mml:mspace width="0.125em" linebreak="nobreak"/><mml:mi mathvariant="normal">mm</mml:mi></mml:mrow></mml:msub></mml:math></inline-formula> (Fig. 4d) values were more notable than
improvements in the RMSE (Fig. 4a) or correlation coefficients (Fig. 4c). In
addition, the “universal” transfer function performed as well as the
transfer functions fitted specifically to measurements from each gauge type.
This indicates that all of the unshielded gauges tested, including those
from K2017a, will accumulate similar amounts of precipitation when exposed
to the same environmental conditions. It also indicates that small
differences in the shapes of these gauges do not affect the relationship
between their catch efficiency and wind speed. Using <inline-formula><mml:math id="M101" display="inline"><mml:mi>t</mml:mi></mml:math></inline-formula> tests, the
measurements adjusted with the “universal” equation were compared to
measurements adjusted with each custom equation. For the unshielded Sutron,
MRW500, and TRwS gauges, the <inline-formula><mml:math id="M102" display="inline"><mml:mi>t</mml:mi></mml:math></inline-formula> tests indicated that there were no
significant differences between<?pagebreak page1445?> measurements adjusted using gauge-specific
transfer functions and the unshielded K2017a transfer function.</p>
</sec>
<sec id="Ch1.S3.SS3">
  <label>3.3</label><title>Single-shielded gauges</title>
      <p id="d1e2312">Transfer functions for the single-Alter shielded Sutron and 1500 mm Geonor
gauge measurements were developed and tested, in addition to transfer
functions for the MRW500 gauge within the small, manufacturer-provided,
single-shield (Fig. 5). These results are discussed in more detail in the
sections below.</p>
<sec id="Ch1.S3.SS3.SSS1">
  <label>3.3.1</label><title>Single-Alter shielded gauges</title>
      <p id="d1e2322">At Marshall, the single-Alter shielded Sutron gauge measurements were
adjusted equally as well using both the custom and the “universal” transfer
function from K2017a (Fig. 5a–d), with a <inline-formula><mml:math id="M103" display="inline"><mml:mi>t</mml:mi></mml:math></inline-formula> test confirming that
measurements adjusted using both methods did not differ significantly from
each other. This indicates that undercatch for the single-Alter shielded
Sutron TPG responds to wind and air temperature in the same manner as the
single-Alter shielded gauges used in K2017a.</p>
      <p id="d1e2332">The 1500 mm Geonor was tested at four different sites, and significant
differences were found between the transfer functions fit to these
measurements and the K2017a “universal” transfer function. Figure 5a–d
support this finding, showing differences between error statistics for
measurements adjusted using the Eq. (1) and Univ. Eq. (1) transfer functions.
These differences were most apparent in the bias and RMSE values estimated
at Weissfluhjoch. For reasons that are not well understood, the catch
efficiency of the single-Alter shielded 1500 mm Geonor gauges at
Weissfluhjoch and Caribou Creek did not decrease with wind speed as much as
at the other sites. The 1500 mm Geonor at Caribou Creek was installed near
low trees, which may have sheltered the gauge from the wind from some
directions; however, a lack of wind direction measurements available in the
WMO-SPICE event dataset from this site prohibits evaluation of this
hypothesis. The Weissfluhjoch site was previously demonstrated to be less
sensitive to wind than other sites (K2017a), for reasons that were also
difficult to understand or confirm. Using the universal transfer function,
the 1500 mm Geonor measurements from Weissfluhjoch were over-corrected (Fig. 5b), whereas using a custom 1500 mm Geonor Eq. (1) adjustment, the resultant
bias was much smaller. The significant differences between the “universal”
transfer function and the transfer functions fit to the 1500 mm Geonor
measurements can be attributed to differences in the measurements used to
create the universal transfer functions and the 1500 mm Geonor transfer
functions. Thirty-five percent of the available 1500 mm Geonor measurements
were recorded at Weissfluhjoch, where the catch efficiency for all the
gauges did not decrease with wind speed to the same degree as most of the
other sites. When the number of Weissfluhjoch measurements contributing to
the 1500 mm transfer functions was artificially reduced, the resultant 1500 mm transfer function was similar to the universal single-Alter adjustment.
At the Marshall and Bratt's Lake sites, where the catch efficiency decreased
with wind speed as expected, the universal transfer function performed
better than the gauge-specific transfer function.</p>
      <p id="d1e2335">In general, the different error statistics generated from the 1500 mm Geonor
measurements indicate that this gauge was subject to more noise than the
host-provided gauges used to develop the universal single-Alter transfer
functions in K2017a. At Marshall, for example, the 1500 mm single-Alter
Geonor RMSE values were about 0.25 mm and the PE<inline-formula><mml:math id="M104" display="inline"><mml:msub><mml:mi/><mml:mrow><mml:mn mathvariant="normal">0.1</mml:mn><mml:mspace linebreak="nobreak" width="0.125em"/><mml:mi mathvariant="normal">mm</mml:mi></mml:mrow></mml:msub></mml:math></inline-formula> values were
roughly 60 %, while for the 600 mm Geonor at this same site, the RMSE values
were approximately 0.15 mm, and the PE<inline-formula><mml:math id="M105" display="inline"><mml:msub><mml:mi/><mml:mrow><mml:mn mathvariant="normal">0.1</mml:mn><mml:mspace linebreak="nobreak" width="0.125em"/><mml:mi mathvariant="normal">mm</mml:mi></mml:mrow></mml:msub></mml:math></inline-formula> values were about 70 % (K2017a).
The increased capacity of the 1500 mm Geonor gauge appears to be associated
with a decrease in sensitivity, which may make it more difficult to
accurately measure snowfall events and distinguish between gauge noise and
light precipitation.</p>
</sec>
<?pagebreak page1446?><sec id="Ch1.S3.SS3.SSS2">
  <label>3.3.2</label><title>Single-shielded MRW500</title>
      <p id="d1e2372">The MRW500 weighing gauge was provided with a custom single-shield, which
was smaller than a standard single-Alter shield and was constructed out of
metal slats mounted at a fixed angle (Fig. 2c). Because no previously
derived transfer function was available for this specific shield, the
“universal” single-Alter shielded adjustment was tested on this
configuration. The resultant RMSE values for the custom and “universal”
transfer functions were similar to each other (Fig. 5e), and the
PE<inline-formula><mml:math id="M106" display="inline"><mml:msub><mml:mi/><mml:mn mathvariant="normal">0.1</mml:mn></mml:msub></mml:math></inline-formula> values were improved by the use of the “universal” SA transfer
function (Fig. 5h). However, the negative bias resulting from the application
of the universal single-Alter adjustment indicates that this gauge was
generally under-corrected, particularly at Bratt's Lake (Fig. 5f).</p>
      <p id="d1e2384">Exponential wind speed transfer functions were also developed separately for
solid and mixed precipitation. After preliminary analysis, Eq. (3) was
developed and used for the shielded MRW500 gauge, because Eq. (2) predicted
unreasonably high catch efficiencies as the wind speed approached 0 m s<inline-formula><mml:math id="M107" display="inline"><mml:msup><mml:mi/><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:msup></mml:math></inline-formula>. This result is probably more closely linked with the scarcity of
low wind speed events and random errors in the low wind speed catch
efficiencies from these two sites, rather than with the specific gauge
configuration. In addition, although an exponential fit was used for these
data because it was more realistic at high wind speeds (where a linear fit
would predict negative catch efficiencies), for the data available, the
shielded MRW500 catch efficiency responded quite linearly to wind speed.
Unfortunately, there were insufficient high-wind data available from the
Bratt's Lake and Marshall sites to evaluate this shield at higher wind speeds,
where the catch efficiency would presumably reach an asymptote at a minimum
value greater than zero. Transfer function coefficients for the MRW500 are
available in the Supplement (Table S1).</p>
</sec>
</sec>
<sec id="Ch1.S3.SS4">
  <label>3.4</label><title>Double-Alter, Belfort double-Alter, and SDFIR shields</title>
      <p id="d1e2408">Measurements recorded by gauges within larger shields – the double-Alter,
Belfort double-Alter, and SDFIR shields – were subject to smaller
uncorrected biases and smaller errors after adjustment. For example, the
RMSE values of the adjusted measurements shown in Fig. 6 were smaller than
those for the single-Alter and unshielded gauges tested (Figs. 4 and 5), and
the PE<inline-formula><mml:math id="M108" display="inline"><mml:msub><mml:mi/><mml:mrow><mml:mn mathvariant="normal">0.1</mml:mn><mml:mspace width="0.125em" linebreak="nobreak"/><mml:mi mathvariant="normal">mm</mml:mi></mml:mrow></mml:msub></mml:math></inline-formula> values were larger. More specific results are discussed
for individual shields below.</p>

      <?xmltex \floatpos{t}?><fig id="Ch1.F6" specific-use="star"><?xmltex \currentcnt{6}?><label>Figure 6</label><caption><p id="d1e2426">Error statistics calculated from the double-Alter shielded
Pluvio<inline-formula><mml:math id="M109" display="inline"><mml:msup><mml:mi/><mml:mn mathvariant="normal">2</mml:mn></mml:msup></mml:math></inline-formula> gauge at CARE (Care Pluv, <bold>a–d</bold>), the double-Alter
shielded Geonor at Marshall (Ma Geon, <bold>a–d</bold>), the Belfort
double-Alter shielded Pluvio<inline-formula><mml:math id="M110" display="inline"><mml:msup><mml:mi/><mml:mn mathvariant="normal">2</mml:mn></mml:msup></mml:math></inline-formula> at CARE (CARE Pluv, <bold>e–f</bold>), the
Belfort double-Alter shielded Geonor at Marshall (Ma Geon, <bold>e–h</bold>),
and the SDFIR shielded Geonor at Marshall (Ma Geon, <bold>i–l</bold>). The
different adjustment types are described in the Fig. 4 caption. Statistics
describing these measurements adjusted using the appropriate pre-SPICE
transfer functions from K2017b are also shown (Pre-SPICE, Eq. 1, yellow).</p></caption>
          <?xmltex \igopts{width=341.433071pt}?><graphic xlink:href="https://hess.copernicus.org/articles/22/1437/2018/hess-22-1437-2018-f06.png"/>

        </fig>

<sec id="Ch1.S3.SS4.SSS1">
  <label>3.4.1</label><title>Double-Alter shield</title>
      <p id="d1e2476">The double-Alter shield was tested at both the CARE and Marshall test beds;
the CARE site had an OTT Pluvio<inline-formula><mml:math id="M111" display="inline"><mml:msup><mml:mi/><mml:mn mathvariant="normal">2</mml:mn></mml:msup></mml:math></inline-formula> gauge in a double-Alter shield, and
the Marshall site had a 600 mm Geonor T-200B3 gauge in a double-Alter
shield. The results presented in Fig. 6a–d indicate that the pre-SPICE
double-Alter transfer function (K2017b) performed as well as the custom
WMO-SPICE transfer function (Fig. 6a–d). A total of 1392 measurements were available from the pre-SPICE Marshall
measurements, while only 723 measurements were available from the WMO-SPICE
measurements (Table 2).<?pagebreak page1447?> However, this new WMO-SPICE correction is arguably
more defensibly applicable to all double-Alter measurements than the
pre-SPICE transfer function, because it was developed using measurements
from two sites.</p>
</sec>
<sec id="Ch1.S3.SS4.SSS2">
  <label>3.4.2</label><title>Belfort double-Alter shield</title>
      <p id="d1e2497">The Belfort double-Alter shield was tested at both the CARE and Marshall
test beds; the CARE site had an OTT Pluvio<inline-formula><mml:math id="M112" display="inline"><mml:msup><mml:mi/><mml:mn mathvariant="normal">2</mml:mn></mml:msup></mml:math></inline-formula> gauge in a Belfort
double-Alter shield, and the Marshall site had a 600 mm Geonor T-200B3 gauge
in a Belfort double-Alter shield. The Belfort double-Alter shield was more
effective at reducing undercatch than the standard double-Alter shield. This
is demonstrated by the generally small RMSE improvements of the corrected
measurements over the uncorrected measurements (Fig. 6e), and also by the
near-zero uncorrected biases for the gauges at both Marshall and CARE (Fig. 6f). These measurements, recorded at two separate sites, confirm the
efficacy of the Belfort double-Alter shield documented by K2017b using
measurements from a single site. Nine hundred and nineteen 30 min
measurements from gauges in Belfort double-Alter shielded gauges were
included in the present WMO-SPICE transfer function development (Table 2),
and 1204 30 min measurements were available for the pre-SPICE Marshall
transfer function development (K2017b). Although the two datasets resulted
in similar transfer functions, we recommend using the transfer functions
determined from the WMO-SPICE measurements, because they include
measurements from two sites, and are therefore expected to be more broadly
applicable.</p>
</sec>
<sec id="Ch1.S3.SS4.SSS3">
  <label>3.4.3</label><title>SDFIR shield</title>
      <p id="d1e2517">Tested only at the Marshall test bed, the SDFIR was the largest wind shield
evaluated in our study, and the uncorrected and corrected SDFIR measurements
were associated with the lowest RMSE and bias values (Fig. 6i and j), and the
highest correlation coefficient and PE<inline-formula><mml:math id="M113" display="inline"><mml:msub><mml:mi/><mml:mrow><mml:mn mathvariant="normal">0.1</mml:mn><mml:mspace linebreak="nobreak" width="0.125em"/><mml:mi mathvariant="normal">mm</mml:mi></mml:mrow></mml:msub></mml:math></inline-formula> values (Fig. 6k
and l) among the shields tested. The catch efficiencies determined using the
custom WMO-SPICE adjustment functions were similar to those derived from the
K2017b SDFIR adjustment, providing independent validation of the pre-SPICE
transfer function in K2017b (Fig. 6i–l).</p>
      <p id="d1e2533">In general, the necessity of transfer function adjustments for
SDFIR-shielded measurements is disputable, as the results in Fig. 6
demonstrate that the corrected measurements were only marginally better than
the uncorrected measurements; only very small improvements were observed in
the mean bias values (Fig. 6j) and the PE<inline-formula><mml:math id="M114" display="inline"><mml:msub><mml:mi/><mml:mrow><mml:mn mathvariant="normal">0.1</mml:mn><mml:mspace width="0.125em" linebreak="nobreak"/><mml:mi mathvariant="normal">mm</mml:mi></mml:mrow></mml:msub></mml:math></inline-formula> values (Fig. 6l).
However, errors in the uncorrected SDFIR measurements were determined to be
significantly different than zero. These SDFIR-shielded results are also
interesting, because they provide a good indication of the magnitude of
errors when comparing well-shielded gauges. As such, these measurements are
a good representation of the current limits in accuracy for precipitation
measurements recorded using two<?pagebreak page1448?> different well-shielded gauges at the same
site. The inferences that can be drawn from such well-shielded measurements
are further emphasized below in the comparison of the different shields and
adjustments.</p>
</sec>
</sec>
<sec id="Ch1.S3.SS5">
  <label>3.5</label><title>Synthesis</title>
<sec id="Ch1.S3.SS5.SSS1">
  <label>3.5.1</label><title>Recommended transfer functions</title>
      <p id="d1e2566">As shown in Table 3, we recommend using the appropriate K017a transfer
functions for all of the unshielded and single-Alter shielded WMO-SPICE
gauges. Although the “universal” single-Alter transfer function performed
poorly on measurements from the 1500 mm Geonor gauges at Caribou Creek and
Weissfluhjoch, we still recommend using it on measurements from single-Alter
shielded 1500 mm Geonor gauges. This is because there is no obvious physical
explanation for a higher catch efficiency for the Geonor 1500 mm gauge
relative to the 600 mm or 1000 mm Geonor gauges (the collecting area and
inlet shape are the same for each configuration). In addition, the
relatively poor performance of the “universal” single-Alter function in this
case may be due to the specific population of 1500 mm Geonor measurements
available within this intercomparison. As also indicated in Table 3, the new
transfer function coefficients provided in the Supplement (Table S1) should
be used to correct measurements from MRW500 gauges with the
manufacturer-provided single-shield, rather than the K2017a “universal”
single Alter correction that was tested on this gauge/shield combination.</p>

<?xmltex \floatpos{t}?><table-wrap id="Ch1.T3"><?xmltex \currentcnt{3}?><label>Table 3</label><caption><p id="d1e2572">Recommended transfer functions for different weighing precipitation
gauges and shields.</p></caption><oasis:table frame="topbot"><?xmltex \begin{scaleboxenv}{.93}[.93]?><oasis:tgroup cols="3">
     <oasis:colspec colnum="1" colname="col1" align="left"/>
     <oasis:colspec colnum="2" colname="col2" align="left"/>
     <oasis:colspec colnum="3" colname="col3" align="left"/>
     <oasis:thead>
       <oasis:row rowsep="1">
         <oasis:entry colname="col1">Shield</oasis:entry>
         <oasis:entry colname="col2">Gauge</oasis:entry>
         <oasis:entry colname="col3">Recommendation</oasis:entry>
       </oasis:row>
     </oasis:thead>
     <oasis:tbody>
       <oasis:row>
         <oasis:entry colname="col1">Unshielded</oasis:entry>
         <oasis:entry colname="col2">Sutron TPG</oasis:entry>
         <oasis:entry colname="col3">Tables 2–3 in K2017a</oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1">Unshielded</oasis:entry>
         <oasis:entry colname="col2">MRW500</oasis:entry>
         <oasis:entry colname="col3">Tables 2–3 in K2017a</oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1">Unshielded</oasis:entry>
         <oasis:entry colname="col2">TRwS 405</oasis:entry>
         <oasis:entry colname="col3">Tables 2–3 in K2017a</oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1">Unshielded</oasis:entry>
         <oasis:entry colname="col2">1500 mm Geonor</oasis:entry>
         <oasis:entry colname="col3">Tables 2–3 in K2017a</oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1">MRW500 shield</oasis:entry>
         <oasis:entry colname="col2">MRW500</oasis:entry>
         <oasis:entry colname="col3">Table S1 in Supplement</oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1">Single Alter</oasis:entry>
         <oasis:entry colname="col2">Sutron TPG</oasis:entry>
         <oasis:entry colname="col3">Tables 2–3 in K2017a</oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1">Double Alter</oasis:entry>
         <oasis:entry colname="col2">Geonor/Pluvio<inline-formula><mml:math id="M115" display="inline"><mml:msup><mml:mi/><mml:mn mathvariant="normal">2</mml:mn></mml:msup></mml:math></inline-formula></oasis:entry>
         <oasis:entry colname="col3">Table S2 in Supplement</oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1">Belfort double Alter</oasis:entry>
         <oasis:entry colname="col2">Geonor/Pluvio<inline-formula><mml:math id="M116" display="inline"><mml:msup><mml:mi/><mml:mn mathvariant="normal">2</mml:mn></mml:msup></mml:math></inline-formula></oasis:entry>
         <oasis:entry colname="col3">Table S3 in Supplement</oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1">SDFIR</oasis:entry>
         <oasis:entry colname="col2">Geonor</oasis:entry>
         <oasis:entry colname="col3">Table 2 in K2017b;</oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1"/>
         <oasis:entry colname="col2"/>
         <oasis:entry colname="col3">Table S4 in Supplement</oasis:entry>
       </oasis:row>
     </oasis:tbody>
   </oasis:tgroup><?xmltex \end{scaleboxenv}?></oasis:table></table-wrap>

      <p id="d1e2739">The double-Alter shield transfer function coefficients in Table S2 in the
Supplement are recommended for use with measurements from weighing gauges in
double-Alter shields. However, due to the limited warm season, liquid
precipitation measurements included in the SPICE datasets, the use of the
Eq. (1) transfer function coefficients presented here is not recommended when
<inline-formula><mml:math id="M117" display="inline"><mml:mrow><mml:msub><mml:mi>T</mml:mi><mml:mi mathvariant="normal">air</mml:mi></mml:msub></mml:mrow></mml:math></inline-formula> is &gt; 5 <inline-formula><mml:math id="M118" display="inline"><mml:msup><mml:mi/><mml:mo>∘</mml:mo></mml:msup></mml:math></inline-formula>C, as they produce unrealistically
high warm-temperature precipitation catch efficiencies. If an Eq. (1) type
function applicable to warm-season measurements is needed, we recommend
using the pre-SPICE function, which performed similarly to the WMO-SPICE
functions (Fig. 6a–d). Like the double-Alter WMO-SPICE transfer function,
the Eq. (1) Belfort double-Alter shield transfer function development did not
include many liquid precipitation events, but in this case, the resultant
transfer functions were more realistic at warm temperatures, and can
therefore be recommended for use in all seasons. The associated transfer
function coefficients are provided in the Supplement (Table S3).</p>
      <p id="d1e2763">For the SDFIR, the pre-SPICE and the custom WMO-SPICE transfer functions
performed quite similarly (Fig. 6i–l). The K2017b SDFIR transfer function
was developed using five years of measurement data (1508 30 min
precipitation events), whereas only two winter seasons (410 30 min events)
were available for the development of the WMO-SPICE transfer function. For
warm temperature and high wind speed conditions, the lack of rain events in
the WMO-SPICE dataset (76 in Table 2) resulted in unrealistically large
SDFIR-shielded catch efficiencies predicted by the Eq. (1) type transfer
function. The K2017b Eq. (1) type catch efficiencies were more realistic for
all temperature/wind speed regimes. For this reason, and because the
pre-SPICE transfer function was developed using measurements from the same
gauge and shield, at the same site, over a much longer period, we recommend
using the Eq. (1) type transfer function from K2017b for measurements from
SDFIR-shielded weighing gauges. Because K2017b did not include Eq. (2)
coefficients, the Eq. (2) transfer function coefficients determined from the
WMO-SPICE measurements are included in Table S4 in the Supplement. The
Eq. (2)
transfer functions, which are only for solid and mixed precipitation, were
unaffected by the lack of warm-temperature precipitation in the WMO-SPICE
measurements.</p>
</sec>
<sec id="Ch1.S3.SS5.SSS2">
  <label>3.5.2</label><title>Comparison of shield types</title>
      <p id="d1e2774">Examples of recommended Eq. (1) type adjustments for solid precipitation are
included in Fig. 7a, with the transfer functions plotted against the gauge
height wind speed with <inline-formula><mml:math id="M119" display="inline"><mml:mrow><mml:msub><mml:mi>T</mml:mi><mml:mi mathvariant="normal">air</mml:mi></mml:msub><mml:mo>=</mml:mo><mml:mo>-</mml:mo><mml:mn mathvariant="normal">5</mml:mn></mml:mrow></mml:math></inline-formula>  <inline-formula><mml:math id="M120" display="inline"><mml:msup><mml:mi/><mml:mo>∘</mml:mo></mml:msup></mml:math></inline-formula>C. The <inline-formula><mml:math id="M121" display="inline"><mml:mrow><mml:msub><mml:mi>T</mml:mi><mml:mi mathvariant="normal">air</mml:mi></mml:msub></mml:mrow></mml:math></inline-formula> value of
<inline-formula><mml:math id="M122" display="inline"><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">5</mml:mn></mml:mrow></mml:math></inline-formula> <inline-formula><mml:math id="M123" display="inline"><mml:msup><mml:mi/><mml:mo>∘</mml:mo></mml:msup></mml:math></inline-formula>C was selected because it was fairly representative of the
solid precipitation events included in this analysis, which had a median
<inline-formula><mml:math id="M124" display="inline"><mml:mrow><mml:msub><mml:mi>T</mml:mi><mml:mi mathvariant="normal">air</mml:mi></mml:msub></mml:mrow></mml:math></inline-formula> of <inline-formula><mml:math id="M125" display="inline"><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">5.2</mml:mn></mml:mrow></mml:math></inline-formula> <inline-formula><mml:math id="M126" display="inline"><mml:msup><mml:mi/><mml:mo>∘</mml:mo></mml:msup></mml:math></inline-formula>C. The unshielded and single Alter “universal”
multi-site Eq. (1) transfer functions from K2017a are also included, as these
were generally recommended over the custom gauge-specific unshielded or
single-Alter transfer functions developed here. Figure 7a demonstrates the
relative magnitudes of the adjustments for different wind shields, with the
more effective shields (SDFIR, Belfort double-Alter) resulting in much
higher catch efficiencies than less effectively shielded gauges
(single-Alter, MRW500 shield) or unshielded gauges.</p>
      <p id="d1e2864">The uncertainty in each transfer function was also estimated for different
wind speeds. For different wind speed bins, transfer function errors were
calculated from differences between the measured catch efficiencies and<?pagebreak page1449?> the
adjustment (or transfer function) fit to the catch efficiencies. The
resultant RMSE values were found to be relatively insensitive to wind speed
(Fig. 7b). This is significant, because catch efficiency was presumably less
affected by the interaction of snow crystals and wind at low wind speed.
This indicates that variability in snowflake habit, which affects
hydrometeor drag and fall velocity, may not be the primary source of
uncertainty in the relationship between catch efficiency and wind speed.
Other causes of uncertainty, such as random variability in the precipitation
gauge measurements and the natural spatial variability of precipitation, may
in fact be more important.</p>
      <p id="d1e2867">In addition, errors in the adjusted catch efficiencies were calculated by
applying the appropriate adjustments to the measurements, and calculating
RMSE values for the resultant catch efficiencies. After adjustment, the
catch efficiency should be equal to approximately 1.0, so the RMSE of the
adjusted catch efficiency was quantified using the difference between the
adjusted catch efficiency and 1.0 (Fig. 7c). The relationship between the
magnitudes of the adjustments and the uncertainties in the adjusted catch
efficiencies is apparent from comparison of Fig. 7a and c. Measurements
that required larger adjustments experienced larger errors in the adjusted
catch efficiencies. This is due, at least in part, to basic arithmetic; for
example, a precipitation measurement associated with a predicted catch
efficiency of 50 % would be doubled by adjustment, and any errors in the
measured catch efficiency would likewise be doubled by the adjustment. At a
given wind speed, the errors in the adjusted catch efficiencies (Fig. 7c)
are approximately equal to the errors in the catch efficiency (Fig. 7b)
divided by the adjustment (Fig. 7a). Errors in the measured catch efficiency
(shown in Fig. 7b) were enhanced by the appropriate adjustments (shown in
Fig. 7a).</p>

      <?xmltex \floatpos{t}?><fig id="Ch1.F7"><?xmltex \currentcnt{7}?><label>Figure 7</label><caption><p id="d1e2873"><bold>(a)</bold> Comparison of recommended Eq. (1) catch efficiency
(CE) adjustments at <inline-formula><mml:math id="M127" display="inline"><mml:mrow><mml:msub><mml:mi>T</mml:mi><mml:mi mathvariant="normal">air</mml:mi></mml:msub><mml:mo>=</mml:mo><mml:mo>-</mml:mo><mml:mn mathvariant="normal">5</mml:mn></mml:mrow></mml:math></inline-formula><inline-formula><mml:math id="M128" display="inline"><mml:msup><mml:mi/><mml:mo>∘</mml:mo></mml:msup></mml:math></inline-formula>C. <bold>(b)</bold> RMSE of
the CE adjustments, estimated by bin-averaging for every 1 m s<inline-formula><mml:math id="M129" display="inline"><mml:msup><mml:mi/><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:msup></mml:math></inline-formula> of
wind speed. <bold>(c)</bold> RMSE of the adjusted CE bin-averaged by wind
speed, estimated by adjusting the measurements and calculating RMSE values
from the resultant catch efficiencies. The SDFIR, Belfort double-Alter,
standard double-Alter and MRW500 transfer function coefficients were
determined from the results presented here. The single-Alter shielded and
unshielded results are from K2017a. Bin-averaged RMSE values are only shown
<bold>(b, c)</bold> when more than 30 values were available within a given
1 m s<inline-formula><mml:math id="M130" display="inline"><mml:msup><mml:mi/><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:msup></mml:math></inline-formula> wind speed range.</p></caption>
            <?xmltex \igopts{width=199.169291pt}?><graphic xlink:href="https://hess.copernicus.org/articles/22/1437/2018/hess-22-1437-2018-f07.png"/>

          </fig>

      <p id="d1e2943">This indicates that despite the necessity and utility of transfer functions,
effective wind shielding is recommended and beneficial for the measurement
of solid precipitation in windy conditions. Many sites and networks use
either unshielded or single-Alter shielded precipitation gauges due to the
cost of purchasing, transporting, installing, and maintaining larger
shields. For example, the DFAR used at the Weissfluhjoch site was built in
eight sections and flown in piece by piece using a helicopter. This level of
expense is necessary at an intercomparison site, but may not be feasible on
a larger scale within observational networks. Many areas where snowfall is
monitored are remote, and cannot be accessed via road. Sufficient space must
also be available to install a large wind shield. In addition, wooden
shields require maintenance, and will eventually become weathered and
require replacement. Such limitations affect meteorological, climate, and
hydrological networks, and must be taken into consideration before selecting
a wind shield. For this reason, the performance of the Belfort double-Alter
wind shield is notable, as it is much smaller than the SDFIR and DFAR. A
stainless steel wind shield like the Belfort double-Alter can also be
designed to be relatively low maintenance, as compared to a wooden shield.
The efficacy of the Belfort double-Alter shield relative to the standard
double-Alter shield also indicates that further improvements in wind shield
design are possible by altering the geometry and porosity of the wind
shield.</p>
</sec>
</sec>
</sec>
<sec id="Ch1.S4" sec-type="conclusions">
  <label>4</label><title>Conclusions</title>
      <p id="d1e2956">New transfer functions were developed using precipitation measurements from
both host- and manufacturer-provided WMO-SPICE weighing gauges, and were
tested alongside existing transfer functions. The resultant errors in
corrected precipitation measurements were presented, and recommendations for
the correction of different types of weighing gauges and shield
configurations were made. These<?pagebreak page1450?> transfer functions were demonstrated to
reduce the mean bias of weighing gauge measurements relative to the DFAR,
and the remaining uncertainty in the corrected measurements was described
using different statistics.</p>
      <p id="d1e2959">For the unshielded and single-Alter shielded weighing gauges provided by
different manufactures for testing in WMO-SPICE, the “universal” multi-site
transfer function developed in K2017a typically worked as well as the
gauge-specific transfer functions developed in this study. Therefore, the
more universal unshielded and single-Alter multi-site transfer functions
from K2017a are recommended for adjusting measurements from all the
unshielded and single-Alter shielded weighing gauges tested.</p>
      <p id="d1e2962">The low-porosity double-Alter shield manufactured by Belfort performed well,
relative to the DFAR, with an average uncorrected bias of only <inline-formula><mml:math id="M131" display="inline"><mml:mo>-</mml:mo></mml:math></inline-formula>0.04 mm,
or <inline-formula><mml:math id="M132" display="inline"><mml:mo>-</mml:mo></mml:math></inline-formula>5.4 %. The Belfort double-Alter shielded gauges performed better
than weighing gauges in traditional single- and double-Alter shields,
suggesting that it is a viable, high-efficacy option for networks or sites
that do not have the resources to build, site, and maintain a large wooden
shield like the SDFIR or DFIR.</p>
      <p id="d1e2979">Precipitation measurements from weighing gauges in higher-efficacy shields,
such as the SDFIR and the Belfort double-Alter, showed not only much smaller
uncorrected biases relative to the corresponding reference configurations,
but also smaller adjusted RMSE and higher adjusted PE<inline-formula><mml:math id="M133" display="inline"><mml:msub><mml:mi/><mml:mrow><mml:mn mathvariant="normal">0.1</mml:mn><mml:mspace linebreak="nobreak" width="0.125em"/><mml:mi mathvariant="normal">mm</mml:mi></mml:mrow></mml:msub></mml:math></inline-formula>.
Measurements from these gauge/shield configurations required less adjustment
than the unshielded gauges tested, and the resultant errors estimated by
comparing the adjusted measurements to the DFAR measurements were also much
smaller. The errors that remained after adjusting the unshielded and
single-Alter shielded measurements were much larger than the errors
experienced by the more effectively shielded gauges. Upon closer inspection
and bin-averaging by wind speed, the magnitude of uncorrectable errors in
the adjusted measurements increased with the size of the required
adjustment; at higher wind speeds, where less-effectively shielded
measurements required doubling or even tripling, the uncertainty in the
measurements was also doubled or tripled, accordingly. This suggests that
there is a limit to the amount of uncertainty that can be removed by such
adjustments, and the transfer functions presented here may already be
approaching this limit. These results also suggest that although adjusted
unshielded and single-Alter shielded gauge measurements can be used to
measure the total amount of precipitation without a large bias, the best way
to reduce the uncertainty of the measurement is to shield the gauge more
effectively using a shield such as the DFIR, SDFIR, or Belfort double-Alter.</p>
</sec>
<sec id="Ch1.S5">
  <label>5</label><title>Future work</title>
      <p id="d1e3004">The transfer functions developed and tested in this study are intended to
adjust solid and mixed precipitation measurements recorded by weighing
gauges. For other types of winter precipitation sensors, such as
disdrometers, present weather sensors, and heated tipping-bucket gauges,
further research is needed to develop similar adjustment methods. Transfer
functions are also needed for measurements at larger spatial scales; for
example, adjustments are needed for gridded global precipitation product
generation by national meteorological and climatic networks, and for the
validation of global hydrologic, weather, and climate models. With
unshielded precipitation gauge measurement errors potentially exceeding
100 % of the measured precipitation in windy and cold conditions, the
results of such research may be significant, especially in Arctic and
mountainous regions.</p>
      <p id="d1e3007">For the application of these transfer functions, high quality and
representative wind speed and air temperature measurements are necessary.
Wind speed measurements that accurately characterize the area around the
precipitation gauge must be obtained carefully, because small-scale changes
in the wind field can be caused by vegetation, buildings, and even the
infrastructure of the monitoring site itself (such as solar panels, towers,
etc.). The application of transfer functions using gridded measurements will
also be affected by errors in wind speed and air temperature, and unresolved
changes in surface roughness, local topography, and siting. The effects of
such errors would propagate through the transfer function to the resultant
catch efficiency, so the adjusted precipitation must also be examined. Such
work can be performed using high-quality reference precipitation
measurements for validation, which may additionally reveal climate biases in
the transfer functions. Since a limited number of WMO-SPICE sites with a
DFAR configuration were available to develop the transfer functions, not all
climate types were well represented. For example; no maritime or Arctic
sites were included in WMO-SPICE. The work described here constitutes an
important step forward in the development and evaluation of transfer
functions for precipitation measurements, and it also presents opportunities
for further improvements.</p>
</sec>

      
      </body>
    <back><notes notes-type="dataavailability"><title>Data availability</title>

      <p id="d1e3014">The data used in this analysis were collected during the
WMO-SPICE project on behalf of the WMO Commission for Instruments and Methods
of Observations (CIMO). At the time of publication, the WMO-SPICE final
report remains in progress, and the project data protocol restricts releasing
the data until the final report has been completed. After the final report
has been released, the data will be made available to the public and can be
obtained by contacting the corresponding author.</p>
  </notes><app-group>
        <supplementary-material position="anchor"><p id="d1e3017">The supplement related to this article is available online at: <inline-supplementary-material xlink:href="https://doi.org/10.5194/hess-22-1437-2018-supplement" xlink:title="pdf">https://doi.org/10.5194/hess-22-1437-2018-supplement</inline-supplementary-material>.</p></supplementary-material>
        </app-group><notes notes-type="competinginterests"><title>Competing interests</title>

      <p id="d1e3026">The authors declare that they have no conflict of
interest.</p>
  </notes><notes notes-type="disclaimer"><title>Disclaimer</title>

      <p id="d1e3032">The analysis and views described herein are those of the authors
at this time, and do not necessarily represent the official outcome of
WMO-SPICE. Mention of commercial companies or products is solely for the
purposes of information and assessment within the scope of the present work,
and does not constitute a commercial endorsement of any instrument or
instrument manufacturer by the authors or the WMO.</p>
  </notes><notes notes-type="sistatement"><title>Special issue statement</title>

      <p id="d1e3038">This article is part of the special issue “The World
Meteorological Organization Solid Precipitation InterComparison Experiment
(WMO-SPICE) and its applications (AMT/ESSD/HESS/TC inter-journal SI)”. It is
not associated with a conference.</p>
  </notes><ack><title>Acknowledgements</title><p id="d1e3044">The authors thank Hagop Mouradian from Environment and Climate Change Canada
for contributing the mapped site locations (Fig. 1). We thank the
manufacturers that provided many of the sensors used to produce these
results. We also thank the World Meteorological Organization for supporting
this intercomparison. In addition, Howard Diamond, from the Atmospheric
Turbulence and Diffusion Division of NOAA's Air Resources Laboratory, helped
obtain the US and European climate data used to estimate the percentages of
solid precipitation shown in Fig. 1.<?xmltex \hack{\newline}?><?xmltex \hack{\newline}?>
Edited by: Alberto Guadagnini<?xmltex \hack{\newline}?>
Reviewed by: Obbe Tuinenburg and two anonymous referees</p></ack><ref-list>
    <title>References</title>

      <ref id="bib1.bib1"><label>1</label><mixed-citation>Baghapour, B., Wei, C., and Sullivan, P. E.: Numerical simulation of
wind-induced turbulence over precipitation gauges, Atmos. Res.,
189, 82–98, <ext-link xlink:href="https://doi.org/10.1016/j.atmosres.2017.01.016" ext-link-type="DOI">10.1016/j.atmosres.2017.01.016</ext-link>,
2017.</mixed-citation></ref>
      <ref id="bib1.bib2"><label>2</label><mixed-citation>Buisán, S. T., Earle, M. E., Collado, J. L., Kochendorfer, J., Alastrué, J.,
Wolff, M., Smith, C. D., and López-Moreno, J. I.: Assessment of snowfall
accumulation underestimation by tipping bucket gauges in the Spanish
operational network, Atmos. Meas. Tech., 10, 1079–1091,
<ext-link xlink:href="https://doi.org/10.5194/amt-10-1079-2017" ext-link-type="DOI">10.5194/amt-10-1079-2017</ext-link>, 2017.</mixed-citation></ref>
      <ref id="bib1.bib3"><label>3</label><mixed-citation>Chen, R., Liu, J., Kang, E., Yang, Y., Han, C., Liu, Z., Song, Y., Qing, W.,
and Zhu, P.: Precipitation measurement intercomparison in the Qilian
Mountains, north-eastern Tibetan Plateau, The Cryosphere, 9, 1995–2008,
<ext-link xlink:href="https://doi.org/10.5194/tc-9-1995-2015" ext-link-type="DOI">10.5194/tc-9-1995-2015</ext-link>, 2015.</mixed-citation></ref>
      <ref id="bib1.bib4"><label>4</label><mixed-citation>Colli, M., Rasmussen, R., Thériault, J. M., Lanza, L. G., Baker, C. B.,
and Kochendorfer, J.: An improved trajectory model to evaluate the
collection performance of snow gauges, J. Appl. Meteorol. Clim., 54, 1826–1836, <ext-link xlink:href="https://doi.org/10.1175/JAMC-D-15-0035.1" ext-link-type="DOI">10.1175/JAMC-D-15-0035.1</ext-link>, 2015.</mixed-citation></ref>
      <ref id="bib1.bib5"><label>5</label><mixed-citation>Colli, M., Lanza, L. G., Rasmussen, R., and Theriault, J. M.: The Collection
Efficiency of Shielded and Unshielded Precipitation Gauges. Part II:
Modeling Particle Trajectories, J. Hydrometeorol., 17, 245–255,
<ext-link xlink:href="https://doi.org/10.1175/jhm-d-15-0011.1" ext-link-type="DOI">10.1175/jhm-d-15-0011.1</ext-link>, 2016.</mixed-citation></ref>
      <ref id="bib1.bib6"><label>6</label><mixed-citation>
Goodison, B., Louie, P., and Yang, D.: The WMO solid precipitation
measurement intercomparison, World Meteorological
Organization-Publications-WMO TD, 65–70, 1998.</mixed-citation></ref>
      <ref id="bib1.bib7"><label>7</label><mixed-citation>Goodison, B. E.: Accuracy of Canadian snow gauge measurements, J. Appl. Meteorol., 17, 1542–1548, <ext-link xlink:href="https://doi.org/10.1175/1520-0450(1978)017&lt;1542:aocsgm&gt;2.0.co;2" ext-link-type="DOI">10.1175/1520-0450(1978)017&lt;1542:aocsgm&gt;2.0.co;2</ext-link>, 1978.</mixed-citation></ref>
      <ref id="bib1.bib8"><label>8</label><mixed-citation>Groisman, P. Y., Koknaeva, V. V., Belokrylova, T. A., and Karl, T. R.:
Overcoming biases of precipitation measurement –  a history of the USSR
experience, B. Am. Meteorol. Soc., 72, 1725–1733,
<ext-link xlink:href="https://doi.org/10.1175/1520-0477(1991)072&lt;1725:obopma&gt;2.0.co;2" ext-link-type="DOI">10.1175/1520-0477(1991)072&lt;1725:obopma&gt;2.0.co;2</ext-link>, 1991.</mixed-citation></ref>
      <ref id="bib1.bib9"><label>9</label><mixed-citation>Kochendorfer, J., Nitu, R., Wolff, M., Mekis, E., Rasmussen, R., Baker, B.,
Earle, M. E., Reverdin, A., Wong, K., Smith, C. D., Yang, D., Roulet, Y.-A.,
Buisan, S., Laine, T., Lee, G., Aceituno, J. L. C., Alastrué, J., Isaksen,
K., Meyers, T., Brækkan, R., Landolt, S., Jachcik, A., and Poikonen, A.:
Analysis of single-Alter-shielded and unshielded measurements of mixed and
solid precipitation from WMO-SPICE, Hydrol. Earth Syst. Sci., 21, 3525–3542,
<ext-link xlink:href="https://doi.org/10.5194/hess-21-3525-2017" ext-link-type="DOI">10.5194/hess-21-3525-2017</ext-link>, 2017a.</mixed-citation></ref>
      <ref id="bib1.bib10"><label>10</label><mixed-citation>Kochendorfer, J., Rasmussen, R., Wolff, M., Baker, B., Hall, M. E., Meyers,
T., Landolt, S., Jachcik, A., Isaksen, K., Brækkan, R., and Leeper, R.: The
quantification and correction of wind-induced precipitation measurement
errors, Hydrol. Earth Syst. Sci., 21, 1973–1989,
<ext-link xlink:href="https://doi.org/10.5194/hess-21-1973-2017" ext-link-type="DOI">10.5194/hess-21-1973-2017</ext-link>, 2017b.</mixed-citation></ref>
      <ref id="bib1.bib11"><label>11</label><mixed-citation>Ma, Y., Zhang, Y., Yang, D., and Bin Farhan, S.: Precipitation bias
variability versus various gauges under different climatic conditions over
the Third Pole Environment (TPE) region, Int. J. Climatol, 35, 1201–1211, <ext-link xlink:href="https://doi.org/10.1002/joc.4045" ext-link-type="DOI">10.1002/joc.4045</ext-link>, 2015.</mixed-citation></ref>
      <ref id="bib1.bib12"><label>12</label><mixed-citation>Nespor, V. and Sevruk, B.: Estimation of wind-induced error of rainfall
gauge measurements using a numerical simulation, J. Atmos. Ocean. Tech., 16, 450–464, <ext-link xlink:href="https://doi.org/10.1175/1520-0426(1999)016&lt;0450:eowieo&gt;2.0.co;2" ext-link-type="DOI">10.1175/1520-0426(1999)016&lt;0450:eowieo&gt;2.0.co;2</ext-link>, 1999.</mixed-citation></ref>
      <ref id="bib1.bib13"><label>13</label><mixed-citation>
Nitu, R.: Proposed configuration of intercomparison sites and of the field
references, Second session of the international organization committee for
the WMO solid precipitation intercomparison experiment, World Meteorological
Organization, Boulder, CO, 2012.</mixed-citation></ref>
      <ref id="bib1.bib14"><label>14</label><mixed-citation>Rasmussen, R., Baker, B., Kochendorfer, J., Meyers, T., Landolt, S.,
Fischer, A. P., Black, J., Theriault, J. M., Kucera, P., Gochis, D., Smith,
C., Nitu, R., Hall, M., Ikeda, K., and Gutmann, E.: How Well Are We
Measuring Snow: The NOAA/FAA/NCAR Winter Precipitation Test Bed, B. Am. Meteorol. Soc., 93, 811–829, <ext-link xlink:href="https://doi.org/10.1175/bams-d-11-00052.1" ext-link-type="DOI">10.1175/bams-d-11-00052.1</ext-link>,
2012.</mixed-citation></ref>
      <ref id="bib1.bib15"><label>15</label><mixed-citation>
Reverdin, A.: Description of the Quality Control and Event Selection
Procedures used within the WMO-SPICE Project, Proceedings of the WMO
Technical Conference on Meteorological and Environmental Instruments and
Methods of Observation, Madrid, Spain, 2016.</mixed-citation></ref>
      <ref id="bib1.bib16"><label>16</label><mixed-citation>
Roulet, Y.-A., Reverdin, A., Buisan, S., and Nitu, R.: Non-catchment type
instruments for snowfall measurement and reporting of precipitation type:
General considerations and issues encountered during the WMO CIMO SPICE
experiment, and derived recommendations, Proceedings of the WMO Technical
Conference on Meteorological and Environmental Instruments and Methods of
Observation, Madrid, Spain, 2016.</mixed-citation></ref>
      <ref id="bib1.bib17"><label>17</label><mixed-citation>
Ryu, S., Lee, G., Nitu, R., Smith, C., Lim, E., and Kin, H.-L.: Automatic
Double Fence Reference (DFAR) for measuring solid<?pagebreak page1452?> precipitation: Gauge Based
Characterization, Second session of the international organization committee
for the WMO solid precipitation intercomparison experiment, World
Meteorological Organization, Boulder, CO, 2012.</mixed-citation></ref>
      <ref id="bib1.bib18"><label>18</label><mixed-citation>
Ryu, S., Lee, G., Nitu, R., Smith, C., Lim, E., and Kim, H. L.: Quantitative
comparison of two types of working field reference systems for the
measurement of precipitation amount (R2), Proceedings of the WMO Technical
Conference on Meteorological and Environmental Instruments and Methods of
Observation Madrid, Spain, 2016.</mixed-citation></ref>
      <ref id="bib1.bib19"><label>19</label><mixed-citation>
Sevruk, B., Hertig, J.-A., and Spiess, R.: The effect of a precipitation
gauge orifice rim on the wind field deformation as investigated in a wind
tunnel, Atmos. Environ., Part A. General Topics, 25, 1173–1179,
1991.</mixed-citation></ref>
      <ref id="bib1.bib20"><label>20</label><mixed-citation>Theriault, J. M., Rasmussen, R., Ikeda, K., and Landolt, S.: Dependence of
Snow Gauge Collection Efficiency on Snowflake Characteristics, J. Appl. Meteorol. Clim., 51, 745–762, <ext-link xlink:href="https://doi.org/10.1175/jamc-d-11-0116.1" ext-link-type="DOI">10.1175/jamc-d-11-0116.1</ext-link>,
2012.</mixed-citation></ref>
      <ref id="bib1.bib21"><label>21</label><mixed-citation>Wolff, M., Isaksen, K., Brækkan, R., Alfnes, E., Petersen-Overleir, A., and
Ruud, E.: Measurements of wind-induced loss of solid precipitation:
description of a Norwegian field study, Hydrol. Res., 44, 35–43,
<ext-link xlink:href="https://doi.org/10.2166/nh.2012.166" ext-link-type="DOI">10.2166/nh.2012.166</ext-link>, 2013.</mixed-citation></ref>
      <ref id="bib1.bib22"><label>22</label><mixed-citation>Wolff, M. A., Isaksen, K., Petersen-Øverleir, A., Ødemark, K., Reitan, T.,
and Brækkan, R.: Derivation of a new continuous adjustment function for
correcting wind-induced loss of solid precipitation: results of a Norwegian
field study, Hydrol. Earth Syst. Sci., 19, 951–967,
<ext-link xlink:href="https://doi.org/10.5194/hess-19-951-2015" ext-link-type="DOI">10.5194/hess-19-951-2015</ext-link>, 2015.
</mixed-citation></ref><?xmltex \hack{\newpage}?>
      <ref id="bib1.bib23"><label>23</label><mixed-citation>Yang, D. Q., Goodison, B. E., Metcalfe, J. R., Golubev, V. S., Elomaa, E.,
Gunther, T., Bates, R., Pangburn, T., Hanson, C. L., Emerson, D., Copaciu,
V., and Miklovic, J.: Accuracy of Tretyakov precipitation gauge: Result of
WMO intercomparison, Hydrol. Process., 9, 877–895,
<ext-link xlink:href="https://doi.org/10.1002/hyp.3360090805" ext-link-type="DOI">10.1002/hyp.3360090805</ext-link>, 1995.</mixed-citation></ref>
      <ref id="bib1.bib24"><label>24</label><mixed-citation>Yang, D. Q., Goodison, B. E., Ishida, S., and Benson, C. S.: Adjustment of
daily precipitation data at 10 climate stations in Alaska: Application of
World Meteorological Organization intercomparison results, Water Resour. Res., 34, 241–256, <ext-link xlink:href="https://doi.org/10.1029/97wr02681" ext-link-type="DOI">10.1029/97wr02681</ext-link>, 1998a.</mixed-citation></ref>
      <ref id="bib1.bib25"><label>25</label><mixed-citation>Yang, D. Q., Goodison, B. E., Metcalfe, J. R., Golubev, V. S., Bates, R.,
Pangburn, T., and Hanson, C. L.: Accuracy of NWS 8” standard nonrecording
precipitation gauge: Results and application of WMO intercomparison, J.
Atmos. Ocean. Tech., 15, 54–68,
<ext-link xlink:href="https://doi.org/10.1175/1520-0426(1998)015&lt;0054:aonsnp&gt;2.0.co;2" ext-link-type="DOI">10.1175/1520-0426(1998)015&lt;0054:aonsnp&gt;2.0.co;2</ext-link>,
1998b.</mixed-citation></ref>
      <ref id="bib1.bib26"><label>26</label><mixed-citation>Yang, D. Q., Goodison, B. E., Metcalfe, J. R., Louie, P., Leavesley, G.,
Emerson, D., Hanson, C. L., Golubev, V. S., Elomaa, E., Gunther, T.,
Pangburn, T., Kang, E., and Milkovic, J.: Quantification of precipitation
measurement discontinuity induced by wind shields on national gauges, Water
Resour. Res., 35, 491–508, <ext-link xlink:href="https://doi.org/10.1029/1998wr900042" ext-link-type="DOI">10.1029/1998wr900042</ext-link>, 1999.</mixed-citation></ref>
      <ref id="bib1.bib27"><label>27</label><mixed-citation>Yang, D. Q., Kane, D., Zhang, Z. P., Legates, D., and Goodison, B.: Bias
corrections of long-term (1973–2004) daily precipitation data over the
northern regions, Geophys. Res. Lett., 32, L19501,
<ext-link xlink:href="https://doi.org/10.1029/2005gl024057" ext-link-type="DOI">10.1029/2005gl024057</ext-link>, 2005.</mixed-citation></ref>

  </ref-list></back>
    <!--<article-title-html>Testing and development of transfer functions for weighing precipitation gauges in WMO-SPICE</article-title-html>
<abstract-html><p>Weighing precipitation gauges are used widely for the measurement of all
forms of precipitation, and are typically more accurate than tipping-bucket
precipitation gauges. This is especially true for the measurement of solid
precipitation; however, weighing precipitation gauge measurements must still
be adjusted for undercatch in snowy, windy conditions. In WMO-SPICE (World
Meteorological Organization Solid Precipitation InterComparison Experiment),
different types of weighing precipitation gauges and shields were compared,
and adjustments were determined for the undercatch of solid precipitation
caused by wind. For the various combinations of gauges and shields,
adjustments using both new and previously existing transfer functions were
evaluated. For most of the gauge and shield combinations, previously derived
transfer functions were found to perform as well as those more recently
derived. This indicates that wind shield type (or lack thereof) is more
important in determining the magnitude of wind-induced undercatch than the
type of weighing precipitation gauge. It also demonstrates the potential for
widespread use of the previously developed transfer functions. Another
overarching result was that, in general, the more effective shields, which
were associated with smaller unadjusted errors, also produced more accurate
measurements after adjustment. This indicates that although transfer
functions can effectively reduce measurement biases, effective wind shielding
is still required for the most accurate measurement of solid precipitation.</p></abstract-html>
<ref-html id="bib1.bib1"><label>1</label><mixed-citation>
Baghapour, B., Wei, C., and Sullivan, P. E.: Numerical simulation of
wind-induced turbulence over precipitation gauges, Atmos. Res.,
189, 82–98, <a href="https://doi.org/10.1016/j.atmosres.2017.01.016" target="_blank">https://doi.org/10.1016/j.atmosres.2017.01.016</a>,
2017.
</mixed-citation></ref-html>
<ref-html id="bib1.bib2"><label>2</label><mixed-citation>
Buisán, S. T., Earle, M. E., Collado, J. L., Kochendorfer, J., Alastrué, J.,
Wolff, M., Smith, C. D., and López-Moreno, J. I.: Assessment of snowfall
accumulation underestimation by tipping bucket gauges in the Spanish
operational network, Atmos. Meas. Tech., 10, 1079–1091,
<a href="https://doi.org/10.5194/amt-10-1079-2017" target="_blank">https://doi.org/10.5194/amt-10-1079-2017</a>, 2017.
</mixed-citation></ref-html>
<ref-html id="bib1.bib3"><label>3</label><mixed-citation>
Chen, R., Liu, J., Kang, E., Yang, Y., Han, C., Liu, Z., Song, Y., Qing, W.,
and Zhu, P.: Precipitation measurement intercomparison in the Qilian
Mountains, north-eastern Tibetan Plateau, The Cryosphere, 9, 1995–2008,
<a href="https://doi.org/10.5194/tc-9-1995-2015" target="_blank">https://doi.org/10.5194/tc-9-1995-2015</a>, 2015.
</mixed-citation></ref-html>
<ref-html id="bib1.bib4"><label>4</label><mixed-citation>
Colli, M., Rasmussen, R., Thériault, J. M., Lanza, L. G., Baker, C. B.,
and Kochendorfer, J.: An improved trajectory model to evaluate the
collection performance of snow gauges, J. Appl. Meteorol. Clim., 54, 1826–1836, <a href="https://doi.org/10.1175/JAMC-D-15-0035.1" target="_blank">https://doi.org/10.1175/JAMC-D-15-0035.1</a>, 2015.
</mixed-citation></ref-html>
<ref-html id="bib1.bib5"><label>5</label><mixed-citation>
Colli, M., Lanza, L. G., Rasmussen, R., and Theriault, J. M.: The Collection
Efficiency of Shielded and Unshielded Precipitation Gauges. Part II:
Modeling Particle Trajectories, J. Hydrometeorol., 17, 245–255,
<a href="https://doi.org/10.1175/jhm-d-15-0011.1" target="_blank">https://doi.org/10.1175/jhm-d-15-0011.1</a>, 2016.
</mixed-citation></ref-html>
<ref-html id="bib1.bib6"><label>6</label><mixed-citation>
Goodison, B., Louie, P., and Yang, D.: The WMO solid precipitation
measurement intercomparison, World Meteorological
Organization-Publications-WMO TD, 65–70, 1998.
</mixed-citation></ref-html>
<ref-html id="bib1.bib7"><label>7</label><mixed-citation>
Goodison, B. E.: Accuracy of Canadian snow gauge measurements, J. Appl. Meteorol., 17, 1542–1548, <a href="https://doi.org/10.1175/1520-0450(1978)017&lt;1542:aocsgm&gt;2.0.co;2" target="_blank">https://doi.org/10.1175/1520-0450(1978)017&lt;1542:aocsgm&gt;2.0.co;2</a>, 1978.
</mixed-citation></ref-html>
<ref-html id="bib1.bib8"><label>8</label><mixed-citation>
Groisman, P. Y., Koknaeva, V. V., Belokrylova, T. A., and Karl, T. R.:
Overcoming biases of precipitation measurement –  a history of the USSR
experience, B. Am. Meteorol. Soc., 72, 1725–1733,
<a href="https://doi.org/10.1175/1520-0477(1991)072&lt;1725:obopma&gt;2.0.co;2" target="_blank">https://doi.org/10.1175/1520-0477(1991)072&lt;1725:obopma&gt;2.0.co;2</a>, 1991.
</mixed-citation></ref-html>
<ref-html id="bib1.bib9"><label>9</label><mixed-citation>
Kochendorfer, J., Nitu, R., Wolff, M., Mekis, E., Rasmussen, R., Baker, B.,
Earle, M. E., Reverdin, A., Wong, K., Smith, C. D., Yang, D., Roulet, Y.-A.,
Buisan, S., Laine, T., Lee, G., Aceituno, J. L. C., Alastrué, J., Isaksen,
K., Meyers, T., Brækkan, R., Landolt, S., Jachcik, A., and Poikonen, A.:
Analysis of single-Alter-shielded and unshielded measurements of mixed and
solid precipitation from WMO-SPICE, Hydrol. Earth Syst. Sci., 21, 3525–3542,
<a href="https://doi.org/10.5194/hess-21-3525-2017" target="_blank">https://doi.org/10.5194/hess-21-3525-2017</a>, 2017a.
</mixed-citation></ref-html>
<ref-html id="bib1.bib10"><label>10</label><mixed-citation>
Kochendorfer, J., Rasmussen, R., Wolff, M., Baker, B., Hall, M. E., Meyers,
T., Landolt, S., Jachcik, A., Isaksen, K., Brækkan, R., and Leeper, R.: The
quantification and correction of wind-induced precipitation measurement
errors, Hydrol. Earth Syst. Sci., 21, 1973–1989,
<a href="https://doi.org/10.5194/hess-21-1973-2017" target="_blank">https://doi.org/10.5194/hess-21-1973-2017</a>, 2017b.
</mixed-citation></ref-html>
<ref-html id="bib1.bib11"><label>11</label><mixed-citation>
Ma, Y., Zhang, Y., Yang, D., and Bin Farhan, S.: Precipitation bias
variability versus various gauges under different climatic conditions over
the Third Pole Environment (TPE) region, Int. J. Climatol, 35, 1201–1211, <a href="https://doi.org/10.1002/joc.4045" target="_blank">https://doi.org/10.1002/joc.4045</a>, 2015.
</mixed-citation></ref-html>
<ref-html id="bib1.bib12"><label>12</label><mixed-citation>
Nespor, V. and Sevruk, B.: Estimation of wind-induced error of rainfall
gauge measurements using a numerical simulation, J. Atmos. Ocean. Tech., 16, 450–464, <a href="https://doi.org/10.1175/1520-0426(1999)016&lt;0450:eowieo&gt;2.0.co;2" target="_blank">https://doi.org/10.1175/1520-0426(1999)016&lt;0450:eowieo&gt;2.0.co;2</a>, 1999.
</mixed-citation></ref-html>
<ref-html id="bib1.bib13"><label>13</label><mixed-citation>
Nitu, R.: Proposed configuration of intercomparison sites and of the field
references, Second session of the international organization committee for
the WMO solid precipitation intercomparison experiment, World Meteorological
Organization, Boulder, CO, 2012.
</mixed-citation></ref-html>
<ref-html id="bib1.bib14"><label>14</label><mixed-citation>
Rasmussen, R., Baker, B., Kochendorfer, J., Meyers, T., Landolt, S.,
Fischer, A. P., Black, J., Theriault, J. M., Kucera, P., Gochis, D., Smith,
C., Nitu, R., Hall, M., Ikeda, K., and Gutmann, E.: How Well Are We
Measuring Snow: The NOAA/FAA/NCAR Winter Precipitation Test Bed, B. Am. Meteorol. Soc., 93, 811–829, <a href="https://doi.org/10.1175/bams-d-11-00052.1" target="_blank">https://doi.org/10.1175/bams-d-11-00052.1</a>,
2012.
</mixed-citation></ref-html>
<ref-html id="bib1.bib15"><label>15</label><mixed-citation>
Reverdin, A.: Description of the Quality Control and Event Selection
Procedures used within the WMO-SPICE Project, Proceedings of the WMO
Technical Conference on Meteorological and Environmental Instruments and
Methods of Observation, Madrid, Spain, 2016.
</mixed-citation></ref-html>
<ref-html id="bib1.bib16"><label>16</label><mixed-citation>
Roulet, Y.-A., Reverdin, A., Buisan, S., and Nitu, R.: Non-catchment type
instruments for snowfall measurement and reporting of precipitation type:
General considerations and issues encountered during the WMO CIMO SPICE
experiment, and derived recommendations, Proceedings of the WMO Technical
Conference on Meteorological and Environmental Instruments and Methods of
Observation, Madrid, Spain, 2016.
</mixed-citation></ref-html>
<ref-html id="bib1.bib17"><label>17</label><mixed-citation>
Ryu, S., Lee, G., Nitu, R., Smith, C., Lim, E., and Kin, H.-L.: Automatic
Double Fence Reference (DFAR) for measuring solid precipitation: Gauge Based
Characterization, Second session of the international organization committee
for the WMO solid precipitation intercomparison experiment, World
Meteorological Organization, Boulder, CO, 2012.
</mixed-citation></ref-html>
<ref-html id="bib1.bib18"><label>18</label><mixed-citation>
Ryu, S., Lee, G., Nitu, R., Smith, C., Lim, E., and Kim, H. L.: Quantitative
comparison of two types of working field reference systems for the
measurement of precipitation amount (R2), Proceedings of the WMO Technical
Conference on Meteorological and Environmental Instruments and Methods of
Observation Madrid, Spain, 2016.
</mixed-citation></ref-html>
<ref-html id="bib1.bib19"><label>19</label><mixed-citation>
Sevruk, B., Hertig, J.-A., and Spiess, R.: The effect of a precipitation
gauge orifice rim on the wind field deformation as investigated in a wind
tunnel, Atmos. Environ., Part A. General Topics, 25, 1173–1179,
1991.
</mixed-citation></ref-html>
<ref-html id="bib1.bib20"><label>20</label><mixed-citation>
Theriault, J. M., Rasmussen, R., Ikeda, K., and Landolt, S.: Dependence of
Snow Gauge Collection Efficiency on Snowflake Characteristics, J. Appl. Meteorol. Clim., 51, 745–762, <a href="https://doi.org/10.1175/jamc-d-11-0116.1" target="_blank">https://doi.org/10.1175/jamc-d-11-0116.1</a>,
2012.
</mixed-citation></ref-html>
<ref-html id="bib1.bib21"><label>21</label><mixed-citation>
Wolff, M., Isaksen, K., Brækkan, R., Alfnes, E., Petersen-Overleir, A., and
Ruud, E.: Measurements of wind-induced loss of solid precipitation:
description of a Norwegian field study, Hydrol. Res., 44, 35–43,
<a href="https://doi.org/10.2166/nh.2012.166" target="_blank">https://doi.org/10.2166/nh.2012.166</a>, 2013.
</mixed-citation></ref-html>
<ref-html id="bib1.bib22"><label>22</label><mixed-citation>
Wolff, M. A., Isaksen, K., Petersen-Øverleir, A., Ødemark, K., Reitan, T.,
and Brækkan, R.: Derivation of a new continuous adjustment function for
correcting wind-induced loss of solid precipitation: results of a Norwegian
field study, Hydrol. Earth Syst. Sci., 19, 951–967,
<a href="https://doi.org/10.5194/hess-19-951-2015" target="_blank">https://doi.org/10.5194/hess-19-951-2015</a>, 2015.

</mixed-citation></ref-html>
<ref-html id="bib1.bib23"><label>23</label><mixed-citation>
Yang, D. Q., Goodison, B. E., Metcalfe, J. R., Golubev, V. S., Elomaa, E.,
Gunther, T., Bates, R., Pangburn, T., Hanson, C. L., Emerson, D., Copaciu,
V., and Miklovic, J.: Accuracy of Tretyakov precipitation gauge: Result of
WMO intercomparison, Hydrol. Process., 9, 877–895,
<a href="https://doi.org/10.1002/hyp.3360090805" target="_blank">https://doi.org/10.1002/hyp.3360090805</a>, 1995.
</mixed-citation></ref-html>
<ref-html id="bib1.bib24"><label>24</label><mixed-citation>
Yang, D. Q., Goodison, B. E., Ishida, S., and Benson, C. S.: Adjustment of
daily precipitation data at 10 climate stations in Alaska: Application of
World Meteorological Organization intercomparison results, Water Resour. Res., 34, 241–256, <a href="https://doi.org/10.1029/97wr02681" target="_blank">https://doi.org/10.1029/97wr02681</a>, 1998a.
</mixed-citation></ref-html>
<ref-html id="bib1.bib25"><label>25</label><mixed-citation>
Yang, D. Q., Goodison, B. E., Metcalfe, J. R., Golubev, V. S., Bates, R.,
Pangburn, T., and Hanson, C. L.: Accuracy of NWS 8” standard nonrecording
precipitation gauge: Results and application of WMO intercomparison, J.
Atmos. Ocean. Tech., 15, 54–68,
<a href="https://doi.org/10.1175/1520-0426(1998)015&lt;0054:aonsnp&gt;2.0.co;2" target="_blank">https://doi.org/10.1175/1520-0426(1998)015&lt;0054:aonsnp&gt;2.0.co;2</a>,
1998b.
</mixed-citation></ref-html>
<ref-html id="bib1.bib26"><label>26</label><mixed-citation>
Yang, D. Q., Goodison, B. E., Metcalfe, J. R., Louie, P., Leavesley, G.,
Emerson, D., Hanson, C. L., Golubev, V. S., Elomaa, E., Gunther, T.,
Pangburn, T., Kang, E., and Milkovic, J.: Quantification of precipitation
measurement discontinuity induced by wind shields on national gauges, Water
Resour. Res., 35, 491–508, <a href="https://doi.org/10.1029/1998wr900042" target="_blank">https://doi.org/10.1029/1998wr900042</a>, 1999.
</mixed-citation></ref-html>
<ref-html id="bib1.bib27"><label>27</label><mixed-citation>
Yang, D. Q., Kane, D., Zhang, Z. P., Legates, D., and Goodison, B.: Bias
corrections of long-term (1973–2004) daily precipitation data over the
northern regions, Geophys. Res. Lett., 32, L19501,
<a href="https://doi.org/10.1029/2005gl024057" target="_blank">https://doi.org/10.1029/2005gl024057</a>, 2005.
</mixed-citation></ref-html>--></article>