<?xml version="1.0" encoding="UTF-8"?>
<!DOCTYPE article PUBLIC "-//NLM//DTD Journal Publishing with OASIS Tables v3.0 20080202//EN" "journalpub-oasis3.dtd">
<article xmlns:xlink="http://www.w3.org/1999/xlink" xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:oasis="http://docs.oasis-open.org/ns/oasis-exchange/table" dtd-version="3.0">
  <front>
    <journal-meta>
<journal-id journal-id-type="publisher">HESS</journal-id>
<journal-title-group>
<journal-title>Hydrology and Earth System Sciences</journal-title>
<abbrev-journal-title abbrev-type="publisher">HESS</abbrev-journal-title>
<abbrev-journal-title abbrev-type="nlm-ta">Hydrol. Earth Syst. Sci.</abbrev-journal-title>
</journal-title-group>
<issn pub-type="epub">1607-7938</issn>
<publisher><publisher-name>Copernicus Publications</publisher-name>
<publisher-loc>Göttingen, Germany</publisher-loc>
</publisher>
</journal-meta>

    <article-meta>
      <article-id pub-id-type="doi">10.5194/hess-20-4237-2016</article-id><title-group><article-title>Canopy-scale biophysical controls of transpiration <?xmltex \hack{\newline}?> and evaporation in the Amazon Basin</article-title>
      </title-group><?xmltex \runningtitle{Canopy-scale biophysical controls of transpiration and evaporation in the Amazon Basin}?><?xmltex \runningauthor{K.~Mallick et al.}?>
      <contrib-group>
        <contrib contrib-type="author" corresp="yes" rid="aff1">
          <name><surname>Mallick</surname><given-names>Kaniska</given-names></name>
          <email>kaniska.mallick@gmail.com</email>
        <ext-link>https://orcid.org/0000-0002-2735-930X</ext-link></contrib>
        <contrib contrib-type="author" corresp="yes" rid="aff1">
          <name><surname>Trebs</surname><given-names>Ivonne</given-names></name>
          <email>ivonne.trebs@list.lu</email>
        </contrib>
        <contrib contrib-type="author" corresp="no" rid="aff2">
          <name><surname>Boegh</surname><given-names>Eva</given-names></name>
          
        </contrib>
        <contrib contrib-type="author" corresp="no" rid="aff1">
          <name><surname>Giustarini</surname><given-names>Laura</given-names></name>
          
        </contrib>
        <contrib contrib-type="author" corresp="no" rid="aff1">
          <name><surname>Schlerf</surname><given-names>Martin</given-names></name>
          
        </contrib>
        <contrib contrib-type="author" corresp="no" rid="aff3 aff12">
          <name><surname>Drewry</surname><given-names>Darren T.</given-names></name>
          
        <ext-link>https://orcid.org/0000-0003-2593-7599</ext-link></contrib>
        <contrib contrib-type="author" corresp="no" rid="aff1">
          <name><surname>Hoffmann</surname><given-names>Lucien</given-names></name>
          
        </contrib>
        <contrib contrib-type="author" corresp="no" rid="aff4">
          <name><surname>von Randow</surname><given-names>Celso</given-names></name>
          
        <ext-link>https://orcid.org/0000-0003-1045-4316</ext-link></contrib>
        <contrib contrib-type="author" corresp="no" rid="aff5">
          <name><surname>Kruijt</surname><given-names>Bart</given-names></name>
          
        </contrib>
        <contrib contrib-type="author" corresp="no" rid="aff6">
          <name><surname>Araùjo</surname><given-names>Alessandro</given-names></name>
          
        </contrib>
        <contrib contrib-type="author" corresp="no" rid="aff7">
          <name><surname>Saleska</surname><given-names>Scott</given-names></name>
          
        </contrib>
        <contrib contrib-type="author" corresp="no" rid="aff8">
          <name><surname>Ehleringer</surname><given-names>James R.</given-names></name>
          
        <ext-link>https://orcid.org/0000-0003-2050-3636</ext-link></contrib>
        <contrib contrib-type="author" corresp="no" rid="aff9">
          <name><surname>Domingues</surname><given-names>Tomas F.</given-names></name>
          
        </contrib>
        <contrib contrib-type="author" corresp="no" rid="aff4">
          <name><surname>Ometto</surname><given-names>Jean Pierre H. B.</given-names></name>
          
        </contrib>
        <contrib contrib-type="author" corresp="no" rid="aff4">
          <name><surname>Nobre</surname><given-names>Antonio D.</given-names></name>
          
        </contrib>
        <contrib contrib-type="author" corresp="no" rid="aff10">
          <name><surname>de Moraes</surname><given-names>Osvaldo Luiz Leal</given-names></name>
          
        </contrib>
        <contrib contrib-type="author" corresp="no" rid="aff11">
          <name><surname>Hayek</surname><given-names>Matthew</given-names></name>
          
        <ext-link>https://orcid.org/0000-0001-9792-4362</ext-link></contrib>
        <contrib contrib-type="author" corresp="no" rid="aff11">
          <name><surname>Munger</surname><given-names>J. William</given-names></name>
          
        <ext-link>https://orcid.org/0000-0002-1042-8452</ext-link></contrib>
        <contrib contrib-type="author" corresp="no" rid="aff11">
          <name><surname>Wofsy</surname><given-names>Steven C.</given-names></name>
          
        </contrib>
        <aff id="aff1"><label>1</label><institution>Department of Environmental Research and Innovation, Luxembourg
Institute of Science and Technology (LIST), L4422, Belvaux, Luxembourg</institution>
        </aff>
        <aff id="aff2"><label>2</label><institution>Department of Science and Environment, Roskilde University,
Roskilde, Denmark</institution>
        </aff>
        <aff id="aff3"><label>3</label><institution>Jet Propulsion Laboratory, California Institute
of Technology, 4800 Oak Grove Drive, Pasadena, 91109, USA</institution>
        </aff>
        <aff id="aff4"><label>4</label><institution>Instituto Nacional de Pesquisas Espaciais (INPE), Centro de
Ciência do Sistema Terrestre, São José dos Campos, SP, Brazil</institution>
        </aff>
        <aff id="aff5"><label>5</label><institution>Wageningen Environmental Research (ALTERRA), Wageningen, the
Netherlands</institution>
        </aff>
        <aff id="aff6"><label>6</label><institution>Empresa Brasileira de Pesquisa Agropecuária
(EMBRAPA), Belém, PA, Brazil</institution>
        </aff>
        <aff id="aff7"><label>7</label><institution>Department of Ecology and
Evolutionary Biology, University of Arizona, Tucson, AZ, USA</institution>
        </aff>
        <aff id="aff8"><label>8</label><institution>Department of Biology, University of Utah, Salt Lake City, UT, USA</institution>
        </aff>
        <aff id="aff9"><label>9</label><institution>Faculdade de Filosofia Ciências e Letras de Ribeirão Preto,
Universidade de São Paulo (USP), São Paulo, SP, Brazil</institution>
        </aff>
        <aff id="aff10"><label>10</label><institution>Centro Nacional de Monitoramento e Alertas de Desastres Naturais,
São Paulo, SP, Brazil</institution>
        </aff>
        <aff id="aff11"><label>11</label><institution>Department of Earth and Planetary
Science, Harvard University, Cambridge, MA, USA</institution>
        </aff>
        <aff id="aff12"><label>12</label><institution>Joint Institute
for Regional Earth System Science and Engineering, University of California,
Los Angeles, California, USA</institution>
        </aff>
      </contrib-group>
      <author-notes><corresp id="corr1">Kaniska Mallick (kaniska.mallick@gmail.com) and Ivonne Trebs (ivonne.trebs@list.lu)</corresp></author-notes><pub-date><day>19</day><month>October</month><year>2016</year></pub-date>
      
      <volume>20</volume>
      <issue>10</issue>
      <fpage>4237</fpage><lpage>4264</lpage>
      <history>
        <date date-type="received"><day>30</day><month>December</month><year>2015</year></date>
           <date date-type="rev-request"><day>27</day><month>January</month><year>2016</year></date>
           <date date-type="rev-recd"><day>21</day><month>June</month><year>2016</year></date>
           <date date-type="accepted"><day>14</day><month>September</month><year>2016</year></date>
      </history>
      <permissions>
<license license-type="open-access">
<license-p>This work is licensed under a Creative Commons Attribution 3.0 Unported License. To view a copy of this license, visit <ext-link ext-link-type="uri" xlink:href="http://creativecommons.org/licenses/by/3.0/">http://creativecommons.org/licenses/by/3.0/</ext-link></license-p>
</license>
</permissions><self-uri xlink:href="https://hess.copernicus.org/articles/20/4237/2016/hess-20-4237-2016.html">This article is available from https://hess.copernicus.org/articles/20/4237/2016/hess-20-4237-2016.html</self-uri>
<self-uri xlink:href="https://hess.copernicus.org/articles/20/4237/2016/hess-20-4237-2016.pdf">The full text article is available as a PDF file from https://hess.copernicus.org/articles/20/4237/2016/hess-20-4237-2016.pdf</self-uri>


      <abstract>
    <p>Canopy and aerodynamic conductances (<inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>g</mml:mi><mml:mtext>C</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> and <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>g</mml:mi><mml:mtext>A</mml:mtext></mml:msub><mml:mo>)</mml:mo></mml:mrow></mml:math></inline-formula> are two
of the key land surface biophysical variables that control the land surface
response of land surface schemes in climate models. Their representation is
crucial for predicting transpiration
(<?xmltex \igopts{width=5.690551pt}?><inline-graphic xlink:href="https://hess.copernicus.org/articles/20/4237/2016/hess-20-4237-2016-g01.pdf"/><inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>E</mml:mi><mml:mtext>T</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula>) and evaporation
(<inline-formula><mml:math display="inline"><mml:mrow><mml:mi mathvariant="italic">λ</mml:mi><mml:msub><mml:mi>E</mml:mi><mml:mtext>E</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula>) flux components of the terrestrial latent heat
flux (<inline-formula><mml:math display="inline"><mml:mrow><mml:mi mathvariant="italic">λ</mml:mi><mml:mi>E</mml:mi></mml:mrow></mml:math></inline-formula>), which has important implications for global climate
change and water resource management. By physical integration of radiometric
surface temperature (<inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>T</mml:mi><mml:mtext>R</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula>) into an integrated framework of the
Penman–Monteith and Shuttleworth–Wallace models, we present a novel
approach to directly quantify the canopy-scale biophysical controls on
<inline-formula><mml:math display="inline"><mml:mrow><mml:mi mathvariant="italic">λ</mml:mi><mml:msub><mml:mi>E</mml:mi><mml:mtext>T</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> and <inline-formula><mml:math display="inline"><mml:mrow><mml:mi mathvariant="italic">λ</mml:mi><mml:msub><mml:mi>E</mml:mi><mml:mtext>E</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> over multiple plant
functional types (PFTs) in the Amazon Basin. Combining data from six LBA
(Large-scale Biosphere-Atmosphere Experiment in Amazonia) eddy covariance
tower sites and a <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>T</mml:mi><mml:mtext>R</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula>-driven physically based modeling approach, we
identified the canopy-scale feedback-response mechanism between <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>g</mml:mi><mml:mtext>C</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula>,
<inline-formula><mml:math display="inline"><mml:mrow><mml:mi mathvariant="italic">λ</mml:mi><mml:msub><mml:mi>E</mml:mi><mml:mtext>T</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula>, and atmospheric vapor pressure deficit (<inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>D</mml:mi><mml:mtext>A</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula>),
without using any leaf-scale empirical parameterizations for the modeling.
The <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>T</mml:mi><mml:mtext>R</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula>-based model shows minor biophysical control on
<inline-formula><mml:math display="inline"><mml:mrow><mml:mi mathvariant="italic">λ</mml:mi><mml:msub><mml:mi>E</mml:mi><mml:mtext>T</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> during the wet (rainy) seasons where
<inline-formula><mml:math display="inline"><mml:mrow><mml:mi mathvariant="italic">λ</mml:mi><mml:msub><mml:mi>E</mml:mi><mml:mtext>T</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> becomes predominantly radiation driven and net
radiation (<inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>R</mml:mi><mml:mtext>N</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula>) determines 75 to 80 % of the variances of
<inline-formula><mml:math display="inline"><mml:mrow><mml:mi mathvariant="italic">λ</mml:mi><mml:msub><mml:mi>E</mml:mi><mml:mtext>T</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula>. However, biophysical control on <inline-formula><mml:math display="inline"><mml:mrow><mml:mi mathvariant="italic">λ</mml:mi><mml:msub><mml:mi>E</mml:mi><mml:mtext>T</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula>
is dramatically increased during the dry seasons, and particularly the
2005 drought year, explaining 50 to 65 % of the variances of
<inline-formula><mml:math display="inline"><mml:mrow><mml:mi mathvariant="italic">λ</mml:mi><mml:msub><mml:mi>E</mml:mi><mml:mtext>T</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula>, and indicates <inline-formula><mml:math display="inline"><mml:mrow><mml:mi mathvariant="italic">λ</mml:mi><mml:msub><mml:mi>E</mml:mi><mml:mtext>T</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> to be
substantially soil moisture driven during the rainfall deficit phase. Despite
substantial differences in <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>g</mml:mi><mml:mtext>A</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> between forests and pastures, very
similar canopy–atmosphere “coupling” was found in these two biomes due to
soil moisture-induced decrease in <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>g</mml:mi><mml:mtext>C</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> in the pasture. This revealed
the pragmatic aspect of the <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>T</mml:mi><mml:mtext>R</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula>-driven model behavior that exhibits
a high sensitivity of <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>g</mml:mi><mml:mtext>C</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> to per unit change in wetness as opposed
to <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>g</mml:mi><mml:mtext>A</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> that is marginally sensitive to surface wetness variability.
Our results reveal the occurrence of a significant hysteresis between
<inline-formula><mml:math display="inline"><mml:mrow><mml:mi mathvariant="italic">λ</mml:mi><mml:msub><mml:mi>E</mml:mi><mml:mtext>T</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> and <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>g</mml:mi><mml:mtext>C</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> during the dry season for the pasture
sites, which is attributed to relatively low soil water availability as
compared to the rainforests, likely due to differences in rooting depth
between the two systems. Evaporation was significantly influenced by
<inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>g</mml:mi><mml:mtext>A</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> for all the PFTs and across all wetness conditions. Our
analytical framework logically captures the responses of <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>g</mml:mi><mml:mtext>C</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> and
<inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>g</mml:mi><mml:mtext>A</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> to changes in atmospheric radiation, <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>D</mml:mi><mml:mtext>A</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula>, and surface
radiometric temperature, and thus appears to be promising for the improvement
of existing land–surface–atmosphere exchange parameterizations across a
range of spatial scales.</p>
  </abstract>
    </article-meta>
  </front>
<body>
      

<sec id="Ch1.S1" sec-type="intro">
  <title>Introduction</title>
      <p>The Amazon rainforest is one of the world's most extensive
natural ecosystems, influencing the Earth's water, energy, and carbon cycles
(Malhi, 2012), and is also a major source of global terrestrial
evapotranspiration (<inline-formula><mml:math display="inline"><mml:mi>E</mml:mi></mml:math></inline-formula>) or latent heat flux (<inline-formula><mml:math display="inline"><mml:mrow><mml:mi mathvariant="italic">λ</mml:mi><mml:mi>E</mml:mi></mml:mrow></mml:math></inline-formula>) (Costa et al.,
2010; Harper et al., 2014). An intensification of the Amazon hydrological
cycle was observed in the past 2 decades (Cox et al., 2000; Huntingford et
al., 2008; Gloor et al., 2013). Recent Amazonian droughts have gained
particular attention due to the sensitivity of the tropical forest
<inline-formula><mml:math display="inline"><mml:mrow><mml:mi mathvariant="italic">λ</mml:mi><mml:mi>E</mml:mi></mml:mrow></mml:math></inline-formula> to climate change (Hilker et al., 2014). If persistent
precipitation extremes become more prevalent (Hilker et al., 2014), the
Amazon rainforest may increasingly become a net source of carbon as a result
of both the suppression of net biome exchange by drought and carbon emissions
from fires (Gatti et al., 2014). Changes in land cover due to conversion of
tropical forest to pastures significantly alter the energy partitioning by
decreasing <inline-formula><mml:math display="inline"><mml:mrow><mml:mi mathvariant="italic">λ</mml:mi><mml:mi>E</mml:mi></mml:mrow></mml:math></inline-formula> and increasing sensible heat fluxes (<inline-formula><mml:math display="inline"><mml:mi>H</mml:mi></mml:math></inline-formula>) over
pasture sites (e.g., Priante Filho et al., 2004). This will ultimately lead
to severe consequences for the water balance in the region, with changes to
river discharge already observed in some parts of the basin (Davidson et al.,
2012). Evaluating the <inline-formula><mml:math display="inline"><mml:mrow><mml:mi mathvariant="italic">λ</mml:mi><mml:mi>E</mml:mi></mml:mrow></mml:math></inline-formula> response to changing climate and land use
in the Amazon Basin is critical to understanding the stability of the tropics
within the Earth system (Lawrence and Vandecar, 2015). The control of
<inline-formula><mml:math display="inline"><mml:mrow><mml:mi mathvariant="italic">λ</mml:mi><mml:mi>E</mml:mi></mml:mrow></mml:math></inline-formula> can be viewed as complex supply–demand interactions, where net
radiation and soil moisture represent the supply and the atmospheric vapor
pressure deficit represents the demand. This supply–demand interaction
accelerates the biophysical feedbacks in <inline-formula><mml:math display="inline"><mml:mrow><mml:mi mathvariant="italic">λ</mml:mi><mml:mi>E</mml:mi></mml:mrow></mml:math></inline-formula>, and understanding
these biophysical feedbacks is necessary to assess the terrestrial biosphere
response to water availability. Therefore, quantifying the critical role of
biophysical variables on <inline-formula><mml:math display="inline"><mml:mrow><mml:mi mathvariant="italic">λ</mml:mi><mml:mi>E</mml:mi></mml:mrow></mml:math></inline-formula> will add substantial insight to
assessments of the resilience of the Amazon Basin under global change.</p>
      <p>The aerodynamic and canopy conductances (<inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>g</mml:mi><mml:mtext>A</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> and <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>g</mml:mi><mml:mtext>C</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula>
hereafter) (unit m s<inline-formula><mml:math display="inline"><mml:msup><mml:mi/><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:msup></mml:math></inline-formula>) are the two most important biophysical
variables regulating the evaporation (<inline-formula><mml:math display="inline"><mml:mrow><mml:mi mathvariant="italic">λ</mml:mi><mml:msub><mml:mi>E</mml:mi><mml:mtext>E</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula>) and
transpiration (<inline-formula><mml:math display="inline"><mml:mrow><mml:mi mathvariant="italic">λ</mml:mi><mml:msub><mml:mi>E</mml:mi><mml:mtext>T</mml:mtext></mml:msub><mml:mo>)</mml:mo></mml:mrow></mml:math></inline-formula> flux components of <inline-formula><mml:math display="inline"><mml:mrow><mml:mi mathvariant="italic">λ</mml:mi><mml:mi>E</mml:mi></mml:mrow></mml:math></inline-formula>
(Monteith and Unsworth, 2008; Dolman et al., 2014; Raupach, 1995; Colaizzi et
al., 2012; Bonan et al., 2014). While <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>g</mml:mi><mml:mtext>A</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> controls the bulk
aerodynamic transfer of energy and water through the near-surface boundary
layer, <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>g</mml:mi><mml:mtext>C</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> represents the restriction on water vapor flow through
the aggregated conductance from stomata of the leaves, in the case of a
vegetated surface. In the case of partial vegetation cover, <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>g</mml:mi><mml:mtext>C</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> also
includes the soil surface conductance for evaporation. At a small
<inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>g</mml:mi><mml:mtext>C</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> / <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>g</mml:mi><mml:mtext>A</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> ratio, the vapor pressure deficit close to the
canopy source/sink height (<inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>D</mml:mi><mml:mn mathvariant="normal">0</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula>) approximates the atmospheric vapor
pressure deficit (<inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>D</mml:mi><mml:mtext>A</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula>) due to aerodynamic mixing and/or low
transpiration. This results in a strong canopy–atmosphere coupling, and such
conditions are prevalent under soil moisture deficits, which prevails under
conditions of soil moisture deficit. By contrast, a large
<inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>g</mml:mi><mml:mtext>C</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> / <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>g</mml:mi><mml:mtext>A</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> ratio influences the gradients of vapor
pressure deficit just above the canopy, such that <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>D</mml:mi><mml:mn mathvariant="normal">0</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> tends towards zero
and thus remains different from <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>D</mml:mi><mml:mtext>A</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> (Jarvis and McNaughton, 1986).
This situation reflects a weak canopy–atmosphere coupling, and such
situations prevail under predominantly wet conditions and/or poor aerodynamic
mixing due to wetness-induced low aerodynamic roughness. The
Penman–Monteith (PM) equation is a physically based scheme for quantifying
such biophysical controls on canopy-scale <inline-formula><mml:math display="inline"><mml:mrow><mml:mi mathvariant="italic">λ</mml:mi><mml:msub><mml:mi>E</mml:mi><mml:mtext>E</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> and
<inline-formula><mml:math display="inline"><mml:mrow><mml:mi mathvariant="italic">λ</mml:mi><mml:msub><mml:mi>E</mml:mi><mml:mtext>T</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> from terrestrial ecosystems, treating the vegetation
canopy as “big-leaf” (Monteith, 1965, 1981). Despite its development based
on biophysical principles controlling water vapor exchange, quantifying the
<inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>g</mml:mi><mml:mtext>A</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> and <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>g</mml:mi><mml:mtext>C</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> controls on <inline-formula><mml:math display="inline"><mml:mrow><mml:mi mathvariant="italic">λ</mml:mi><mml:mi>E</mml:mi></mml:mrow></mml:math></inline-formula> through the PM
equation suffers from the continued longstanding uncertainty in the
aggregated stomatal and aerodynamic behavior within the
soil–plant–atmosphere continuum (Matheny et al., 2014; Prihodko et
al., 2008).</p>
      <p>One of the major sources of uncertainties in modeling <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>g</mml:mi><mml:mtext>A</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> is
associated with the empirical (and uncertain) parameterizations of
near-surface boundary-layer dynamics, which is invariably confounded by
space–time variability in atmospheric stability (van der Tol et al., 2009;
Shuttleworth, 1989; Gibson et al., 2011). For example, the Monin–Obukhov
similarity theory (MOST) used for <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>g</mml:mi><mml:mtext>A</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> modeling appears to be only
valid over uniform, extensive, and flat surfaces (Monteith and Unsworth,
2008; van der Tol et al., 2009; Holwerda et al., 2012), and its application
to complex “real” canopy systems is problematic due to chaotic interactions
between turbulence, canopy roughness, and topography (Raupach and Finnigan,
1995; Shuttleworth, 2007; Holwerda et al., 2012). Similarly, <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>g</mml:mi><mml:mtext>C</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula>
varies in space and time due to variations in plant species, photosynthetic
capacity, soil moisture variability, and environmental drivers (Monteith and
Unsworth, 2008; van der Tol et al., 2009). Despite the existence of several
semi-mechanistic and empirical parameterizations for <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>g</mml:mi><mml:mtext>C</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> (e.g., Ball
et al., 1987; Leuning, 1995; Tuzet et al., 2003; Medlyn et al., 2011), the
adaptive tendencies of plant canopies severely compromise the efficacy of
such approaches (Matheny et al., 2014), limiting their applicability over
most landscapes. Thus, debate on the most appropriate model for the canopy
conductance has endured for decades.</p>
      <p>Previous studies in the Amazon Basin focused on developing an observational
understanding of the biogeochemical cycling of energy, water, carbon, trace
gases, and aerosols in Amazonia (Andreae et al., 2002; Malhi et al., 2002; da
Rocha et al., 2009), model-based understanding of surface ecophysiological
behavior and seasonality of <inline-formula><mml:math display="inline"><mml:mrow><mml:mi mathvariant="italic">λ</mml:mi><mml:mi>E</mml:mi></mml:mrow></mml:math></inline-formula> (Baker et al., 2013; Christoffersen
et al., 2014), modeling the environmental controls on <inline-formula><mml:math display="inline"><mml:mrow><mml:mi mathvariant="italic">λ</mml:mi><mml:mi>E</mml:mi></mml:mrow></mml:math></inline-formula> (Hasler
and Avissar, 2007; Costa et al., 2010), understanding the seasonality of
photosynthesis and of <inline-formula><mml:math display="inline"><mml:mrow><mml:mi mathvariant="italic">λ</mml:mi><mml:mi>E</mml:mi></mml:mrow></mml:math></inline-formula> (da Rocha et al., 2004; Restrepo-Coupe et
al., 2013), and the impact of land use on hydrometeorology (Roy and Avissar,
2002; von Randow et al., 2012). However, the combination of climatic and
ecohydrological disturbances will significantly affect stomatal functioning,
the partitioning of <inline-formula><mml:math display="inline"><mml:mrow><mml:mi mathvariant="italic">λ</mml:mi><mml:msub><mml:mi>E</mml:mi><mml:mtext>E</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> <inline-formula><mml:math display="inline"><mml:mo>-</mml:mo></mml:math></inline-formula> <inline-formula><mml:math display="inline"><mml:mrow><mml:mi mathvariant="italic">λ</mml:mi><mml:msub><mml:mi>E</mml:mi><mml:mtext>T</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula>, and
carbon–water–climate interactions of tropical vegetation (Cox et al., 2000;
Mercado et al., 2009). Hence, investigation of the effects of drought and
land cover changes on conductances, <inline-formula><mml:math display="inline"><mml:mrow><mml:mi mathvariant="italic">λ</mml:mi><mml:msub><mml:mi>E</mml:mi><mml:mtext>E</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> and
<inline-formula><mml:math display="inline"><mml:mrow><mml:mi mathvariant="italic">λ</mml:mi><mml:msub><mml:mi>E</mml:mi><mml:mtext>T</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula>, is a topic requiring urgent attention (Blyth et al.,
2010) both because of the cursory way it is handled in the current generation
of parametric models (Matheny et al., 2014) and because of the centrality of
<inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>g</mml:mi><mml:mtext>A</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> and <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>g</mml:mi><mml:mtext>C</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> in controlling modeled flux behaviors
(Villagarcía et al., 2010). The persistent risk of deforestation is
likely to alter the radiation interception, surface temperature, surface
moisture, associated meteorological conditions, and vegetation biophysical
states of different plant functional types (PFTs). Conversion from forest to
pasture is expected to change the <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>g</mml:mi><mml:mtext>C</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> / <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>g</mml:mi><mml:mtext>A</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> ratio of
these ecosystems and impact the evapotranspiration components. Besides
inverting the PM equation using field measurements of <inline-formula><mml:math display="inline"><mml:mrow><mml:mi mathvariant="italic">λ</mml:mi><mml:mi>E</mml:mi></mml:mrow></mml:math></inline-formula>, to date
either photosynthesis-dependent modeling or leaf-scale experiments were
performed to directly quantify <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>g</mml:mi><mml:mtext>C</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> (Ball et al., 1987; Meinzer et
al., 1993, 1997; Monteith, 1995; Jones, 1998; Motzer et al., 2005). However,
an analytical or physical retrieval for <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>g</mml:mi><mml:mtext>A</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> and <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>g</mml:mi><mml:mtext>C</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> is
required not only to better understand the role of the canopy in regulating
evaporation and transpiration, but also to enable our capability to
characterize the conductances using remote observations, across large spatial
domains where in situ observations are not available. This paper aims to
leverage this emerging opportunity by exploring data from the Large-scale
Biosphere-Atmosphere Experiment in Amazonia (LBA) eddy covariance (EC)
observations (e.g., de Goncalves et al., 2013; Restrepo-Coupe et al., 2013)
using a novel analytical modeling technique, the Surface Temperature
Initiated Closure (STIC) (Mallick et al., 2014, 2015), in order to quantify
the biophysical control on <inline-formula><mml:math display="inline"><mml:mrow><mml:mi mathvariant="italic">λ</mml:mi><mml:msub><mml:mi>E</mml:mi><mml:mtext>E</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> and <inline-formula><mml:math display="inline"><mml:mrow><mml:mi mathvariant="italic">λ</mml:mi><mml:msub><mml:mi>E</mml:mi><mml:mtext>T</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula>
over several representative PFTs of the Amazon Basin.</p>
      <p>STIC (STIC1.0 and STIC1.1) provides a unique framework for simultaneously
estimating <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>g</mml:mi><mml:mtext>A</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> and <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>g</mml:mi><mml:mtext>C</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula>, surface energy balance fluxes, and
<inline-formula><mml:math display="inline"><mml:mrow><mml:mi mathvariant="italic">λ</mml:mi><mml:msub><mml:mi>E</mml:mi><mml:mtext>E</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> and <inline-formula><mml:math display="inline"><mml:mrow><mml:mi mathvariant="italic">λ</mml:mi><mml:msub><mml:mi>E</mml:mi><mml:mtext>T</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula>. It is based on finding
analytical solutions for <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>g</mml:mi><mml:mtext>A</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> and <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>g</mml:mi><mml:mtext>C</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> by physically
integrating radiometric surface temperature (<inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>T</mml:mi><mml:mtext>R</mml:mtext></mml:msub><mml:mo>)</mml:mo></mml:mrow></mml:math></inline-formula> information (along
with radiative fluxes and meteorological variables) into the PM model
(Mallick et al., 2014, 2015). The direct estimates of canopy-scale
conductances and <inline-formula><mml:math display="inline"><mml:mrow><mml:mi mathvariant="italic">λ</mml:mi><mml:mi>E</mml:mi></mml:mrow></mml:math></inline-formula> obtained through STIC are independent of any
land surface parameterization. This contrasts with the multi-layer canopy
models that explicitly parameterize the leaf-scale conductances and perform
bottom-up scaling to derive the canopy-scale conductances (Baldocchi et al.,
2002; Drewry et al., 2010). A primary advantage of the approach on which STIC
is based is the ability to directly utilize remotely sensed <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>T</mml:mi><mml:mtext>R</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> to
estimate <inline-formula><mml:math display="inline"><mml:mi>E</mml:mi></mml:math></inline-formula>, thereby providing a capability to estimate <inline-formula><mml:math display="inline"><mml:mi>E</mml:mi></mml:math></inline-formula> over large
spatial scales using a remotely sensed variable that is central to many
ongoing and upcoming missions. This study presents a detailed examination of
the performance of STIC to better understand land–atmosphere interactions in
one of the most critical global ecosystems and addresses the following
science questions and objectives.
<list list-type="order"><list-item>
      <p>How realistic are canopy-scale conductances when estimated analytically
(or non-parametrically) without involving any empirical leaf-scale parameterization?</p></list-item><list-item>
      <p>What are the controls of canopy-scale <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>g</mml:mi><mml:mtext>A</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> and <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>g</mml:mi><mml:mtext>C</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> on evaporation
and transpiration in the Amazon Basin, as evaluated using STIC?</p></list-item><list-item>
      <p>How do the STIC-based canopy-scale conductances compare with known environmental constraints?</p></list-item><list-item>
      <p>Is the biophysical response of <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>g</mml:mi><mml:mtext>C</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> consistent with the leaf-scale
theory (Jarvis and McNaughton, 1986; McNaughton and Jarvis, 1991; Monteith, 1995)?</p></list-item></list>
The following section describes a brief methodology to retrieve <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>g</mml:mi><mml:mtext>C</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula>,
<inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>g</mml:mi><mml:mtext>A</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula>, <inline-formula><mml:math display="inline"><mml:mrow><mml:mi mathvariant="italic">λ</mml:mi><mml:msub><mml:mi>E</mml:mi><mml:mtext>E</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula>, and <inline-formula><mml:math display="inline"><mml:mrow><mml:mi mathvariant="italic">λ</mml:mi><mml:msub><mml:mi>E</mml:mi><mml:mtext>T</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula>. The data sources used for
the analysis are described after the methodology and will be followed by a
comparison of the results with fluxes derived from EC measurements. A
detailed discussion of the results and potential applicability of the method
with implications for global change research are elaborated at the end. A
list of symbols and variables used in the present study is given in Table 1.</p>
</sec>
<sec id="Ch1.S2">
  <title>Methodology</title>
<sec id="Ch1.S2.SS1">
  <title>Theory</title>
      <p>The retrievals of <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>g</mml:mi><mml:mtext>A</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula>, <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>g</mml:mi><mml:mtext>C</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula>, and <inline-formula><mml:math display="inline"><mml:mrow><mml:mi mathvariant="italic">λ</mml:mi><mml:mi>E</mml:mi></mml:mrow></mml:math></inline-formula> are based on
finding a “closure” of the PM equation (Eq. 1 below) using the STIC
framework (Fig. A1) (Mallick et al., 2015). STIC is a physically based
single-source surface energy balance scheme that includes internally
consistent estimation of <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>g</mml:mi><mml:mtext>A</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> and <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>g</mml:mi><mml:mtext>C</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> (Mallick et al., 2014,
2015). Originally designed for application to thermal remote sensing data
from Earth observation sensors, the STIC framework exploits observations of
radiative (<inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>T</mml:mi><mml:mtext>R</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula>) and environmental variables, including net
radiation (<inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>R</mml:mi><mml:mtext>N</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula>), ground heat flux (<inline-formula><mml:math display="inline"><mml:mi>G</mml:mi></mml:math></inline-formula>), air
temperature (<inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>T</mml:mi><mml:mtext>A</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula>), relative humidity (<inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>R</mml:mi><mml:mtext>H</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula>), or vapor pressure (<inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>e</mml:mi><mml:mtext>A</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula>)
at a reference level above the surface.</p>

<?xmltex \floatpos{p}?><table-wrap id="Ch1.T1" specific-use="star"><caption><p>Variables and symbols and their description used in the present study.</p></caption><oasis:table frame="topbot"><oasis:tgroup cols="2">
     <oasis:colspec colnum="1" colname="col1" align="left"/>
     <oasis:colspec colnum="2" colname="col2" align="left"/>
     <oasis:thead>
       <oasis:row>

         <oasis:entry colname="col1">Variables</oasis:entry>

         <oasis:entry colname="col2">Description</oasis:entry>

       </oasis:row>
       <oasis:row>

         <oasis:entry colname="col1">and</oasis:entry>

         <oasis:entry colname="col2"/>

       </oasis:row>
       <oasis:row rowsep="1">

         <oasis:entry colname="col1">symbols</oasis:entry>

         <oasis:entry colname="col2"/>

       </oasis:row>
     </oasis:thead>
     <oasis:tbody>
       <oasis:row>

         <oasis:entry colname="col1"><inline-formula><mml:math display="inline"><mml:mrow><mml:mi mathvariant="italic">λ</mml:mi><mml:mi>E</mml:mi></mml:mrow></mml:math></inline-formula></oasis:entry>

         <oasis:entry colname="col2">Evapotranspiration (evaporation <inline-formula><mml:math display="inline"><mml:mo>+</mml:mo></mml:math></inline-formula> transpiration) as latent heat flux (W m<inline-formula><mml:math display="inline"><mml:msup><mml:mi/><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">2</mml:mn></mml:mrow></mml:msup></mml:math></inline-formula>)</oasis:entry>

       </oasis:row>
       <oasis:row>

         <oasis:entry colname="col1"><inline-formula><mml:math display="inline"><mml:mi>H</mml:mi></mml:math></inline-formula></oasis:entry>

         <oasis:entry colname="col2">Sensible heat flux (W m<inline-formula><mml:math display="inline"><mml:msup><mml:mi/><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">2</mml:mn></mml:mrow></mml:msup></mml:math></inline-formula>)</oasis:entry>

       </oasis:row>
       <oasis:row>

         <oasis:entry colname="col1"><inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>R</mml:mi><mml:mtext>N</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula></oasis:entry>

         <oasis:entry colname="col2">Net radiation (W m<inline-formula><mml:math display="inline"><mml:msup><mml:mi/><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">2</mml:mn></mml:mrow></mml:msup></mml:math></inline-formula>)</oasis:entry>

       </oasis:row>
       <oasis:row>

         <oasis:entry colname="col1"><inline-formula><mml:math display="inline"><mml:mi>G</mml:mi></mml:math></inline-formula></oasis:entry>

         <oasis:entry colname="col2">Ground heat flux (W m<inline-formula><mml:math display="inline"><mml:msup><mml:mi/><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">2</mml:mn></mml:mrow></mml:msup></mml:math></inline-formula>)</oasis:entry>

       </oasis:row>
       <oasis:row>

         <oasis:entry colname="col1"><inline-formula><mml:math display="inline"><mml:mi mathvariant="italic">ϕ</mml:mi></mml:math></inline-formula></oasis:entry>

         <oasis:entry colname="col2">Net available energy (W m<inline-formula><mml:math display="inline"><mml:msup><mml:mi/><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">2</mml:mn></mml:mrow></mml:msup></mml:math></inline-formula>)</oasis:entry>

       </oasis:row>
       <oasis:row>

         <oasis:entry colname="col1"><inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>T</mml:mi><mml:mtext>A</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula></oasis:entry>

         <oasis:entry colname="col2">Air temperature (<inline-formula><mml:math display="inline"><mml:msup><mml:mi/><mml:mo>∘</mml:mo></mml:msup></mml:math></inline-formula>C)</oasis:entry>

       </oasis:row>
       <oasis:row>

         <oasis:entry colname="col1"><inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>T</mml:mi><mml:mtext>D</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula></oasis:entry>

         <oasis:entry colname="col2">Dew-point temperature (<inline-formula><mml:math display="inline"><mml:msup><mml:mi/><mml:mo>∘</mml:mo></mml:msup></mml:math></inline-formula>C)</oasis:entry>

       </oasis:row>
       <oasis:row>

         <oasis:entry colname="col1"><inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>T</mml:mi><mml:mtext>R</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula></oasis:entry>

         <oasis:entry colname="col2">Radiometric surface temperature (<inline-formula><mml:math display="inline"><mml:msup><mml:mi/><mml:mo>∘</mml:mo></mml:msup></mml:math></inline-formula>C)</oasis:entry>

       </oasis:row>
       <oasis:row>

         <oasis:entry colname="col1"><inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>R</mml:mi><mml:mtext>H</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula></oasis:entry>

         <oasis:entry colname="col2">Relative humidity (%)</oasis:entry>

       </oasis:row>
       <oasis:row>

         <oasis:entry colname="col1"><inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>e</mml:mi><mml:mtext>A</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula></oasis:entry>

         <oasis:entry colname="col2">Atmospheric vapor pressure at the level of <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>T</mml:mi><mml:mtext>A</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> measurement (hPa)</oasis:entry>

       </oasis:row>
       <oasis:row>

         <oasis:entry colname="col1"><inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>D</mml:mi><mml:mtext>A</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula></oasis:entry>

         <oasis:entry colname="col2">Atmospheric vapor pressure deficit at the level of <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>T</mml:mi><mml:mtext>A</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> measurement (hPa)</oasis:entry>

       </oasis:row>
       <oasis:row>

         <oasis:entry colname="col1"><inline-formula><mml:math display="inline"><mml:mi>u</mml:mi></mml:math></inline-formula></oasis:entry>

         <oasis:entry colname="col2">Wind speed (m s<inline-formula><mml:math display="inline"><mml:msup><mml:mi/><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:msup></mml:math></inline-formula>)</oasis:entry>

       </oasis:row>
       <oasis:row>

         <oasis:entry colname="col1"><inline-formula><mml:math display="inline"><mml:mrow><mml:msup><mml:mi>u</mml:mi><mml:mo>*</mml:mo></mml:msup></mml:mrow></mml:math></inline-formula></oasis:entry>

         <oasis:entry colname="col2">Friction velocity (m s<inline-formula><mml:math display="inline"><mml:msup><mml:mi/><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:msup></mml:math></inline-formula>)</oasis:entry>

       </oasis:row>
       <oasis:row>

         <oasis:entry colname="col1"><inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>T</mml:mi><mml:mtext>SD</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula></oasis:entry>

         <oasis:entry colname="col2">Dew-point temperature at the source/sink height (<inline-formula><mml:math display="inline"><mml:msup><mml:mi/><mml:mo>∘</mml:mo></mml:msup></mml:math></inline-formula>C)</oasis:entry>

       </oasis:row>
       <oasis:row>

         <oasis:entry colname="col1"><inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>T</mml:mi><mml:mn mathvariant="normal">0</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula></oasis:entry>

         <oasis:entry colname="col2">Aerodynamic temperature or source/sink height temperature (<inline-formula><mml:math display="inline"><mml:msup><mml:mi/><mml:mo>∘</mml:mo></mml:msup></mml:math></inline-formula>C)</oasis:entry>

       </oasis:row>
       <oasis:row>

         <oasis:entry colname="col1"><inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>e</mml:mi><mml:mtext>S</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula></oasis:entry>

         <oasis:entry colname="col2">“Effective” vapor pressure of evaporating front near the surface (hPa)</oasis:entry>

       </oasis:row>
       <oasis:row>

         <oasis:entry colname="col1"><inline-formula><mml:math display="inline"><mml:mrow><mml:msubsup><mml:mi>e</mml:mi><mml:mtext>S</mml:mtext><mml:mo>*</mml:mo></mml:msubsup></mml:mrow></mml:math></inline-formula></oasis:entry>

         <oasis:entry colname="col2">Saturation vapor pressure of the surface (hPa)</oasis:entry>

       </oasis:row>
       <oasis:row>

         <oasis:entry colname="col1"><inline-formula><mml:math display="inline"><mml:mrow><mml:msubsup><mml:mi>e</mml:mi><mml:mn mathvariant="normal">0</mml:mn><mml:mo>*</mml:mo></mml:msubsup></mml:mrow></mml:math></inline-formula></oasis:entry>

         <oasis:entry colname="col2">Saturation vapor pressure at the source/sink height (hPa)</oasis:entry>

       </oasis:row>
       <oasis:row>

         <oasis:entry colname="col1"><inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>e</mml:mi><mml:mn mathvariant="normal">0</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula></oasis:entry>

         <oasis:entry colname="col2">Atmospheric vapor pressure at the source/sink height (hPa)</oasis:entry>

       </oasis:row>
       <oasis:row>

         <oasis:entry colname="col1"><inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>D</mml:mi><mml:mn mathvariant="normal">0</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula></oasis:entry>

         <oasis:entry colname="col2">Atmospheric vapor pressure deficit at the source/sink height (hPa)</oasis:entry>

       </oasis:row>
       <oasis:row>

         <oasis:entry colname="col1"><inline-formula><mml:math display="inline"><mml:mrow><mml:mi mathvariant="italic">λ</mml:mi><mml:msub><mml:mi>E</mml:mi><mml:mtext>eq</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula></oasis:entry>

         <oasis:entry colname="col2">Equilibrium latent heat flux (W m<inline-formula><mml:math display="inline"><mml:msup><mml:mi/><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">2</mml:mn></mml:mrow></mml:msup></mml:math></inline-formula>)</oasis:entry>

       </oasis:row>
       <oasis:row>

         <oasis:entry colname="col1"><inline-formula><mml:math display="inline"><mml:mrow><mml:mi mathvariant="italic">λ</mml:mi><mml:msub><mml:mi>E</mml:mi><mml:mtext>imp</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula></oasis:entry>

         <oasis:entry colname="col2">Imposed latent heat flux (W m<inline-formula><mml:math display="inline"><mml:msup><mml:mi/><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">2</mml:mn></mml:mrow></mml:msup></mml:math></inline-formula>)</oasis:entry>

       </oasis:row>
       <oasis:row>

         <oasis:entry colname="col1"><inline-formula><mml:math display="inline"><mml:mrow><mml:mi mathvariant="italic">λ</mml:mi><mml:msub><mml:mi>E</mml:mi><mml:mtext>E</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula></oasis:entry>

         <oasis:entry colname="col2">Evaporation as flux (W m<inline-formula><mml:math display="inline"><mml:msup><mml:mi/><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">2</mml:mn></mml:mrow></mml:msup></mml:math></inline-formula>)</oasis:entry>

       </oasis:row>
       <oasis:row>

         <oasis:entry colname="col1"><inline-formula><mml:math display="inline"><mml:mrow><mml:mi mathvariant="italic">λ</mml:mi><mml:msub><mml:mi>E</mml:mi><mml:mtext>T</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula></oasis:entry>

         <oasis:entry colname="col2">Transpiration as flux (W m<inline-formula><mml:math display="inline"><mml:msup><mml:mi/><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">2</mml:mn></mml:mrow></mml:msup></mml:math></inline-formula>)</oasis:entry>

       </oasis:row>
       <oasis:row>

         <oasis:entry colname="col1"><inline-formula><mml:math display="inline"><mml:mi>E</mml:mi></mml:math></inline-formula></oasis:entry>

         <oasis:entry colname="col2">Evapotranspiration (evaporation <inline-formula><mml:math display="inline"><mml:mo>+</mml:mo></mml:math></inline-formula> transpiration) as depth of water (mm)</oasis:entry>

       </oasis:row>
       <oasis:row>

         <oasis:entry colname="col1"><inline-formula><mml:math display="inline"><mml:mrow><mml:mi mathvariant="italic">λ</mml:mi><mml:msup><mml:mi>E</mml:mi><mml:mo>*</mml:mo></mml:msup></mml:mrow></mml:math></inline-formula></oasis:entry>

         <oasis:entry colname="col2">Potential evaporation as flux (W m<inline-formula><mml:math display="inline"><mml:msup><mml:mi/><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">2</mml:mn></mml:mrow></mml:msup></mml:math></inline-formula>)</oasis:entry>

       </oasis:row>
       <oasis:row>

         <oasis:entry colname="col1"><inline-formula><mml:math display="inline"><mml:mrow><mml:mi mathvariant="italic">λ</mml:mi><mml:msubsup><mml:mi>E</mml:mi><mml:mtext>T</mml:mtext><mml:mo>*</mml:mo></mml:msubsup></mml:mrow></mml:math></inline-formula></oasis:entry>

         <oasis:entry colname="col2">Potential transpiration as flux (W m<inline-formula><mml:math display="inline"><mml:msup><mml:mi/><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">2</mml:mn></mml:mrow></mml:msup></mml:math></inline-formula>)</oasis:entry>

       </oasis:row>
       <oasis:row>

         <oasis:entry colname="col1"><inline-formula><mml:math display="inline"><mml:mrow><mml:mi mathvariant="italic">λ</mml:mi><mml:msub><mml:mi>E</mml:mi><mml:mtext>W</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula></oasis:entry>

         <oasis:entry colname="col2">Wet environment evaporation as flux (W m<inline-formula><mml:math display="inline"><mml:msup><mml:mi/><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">2</mml:mn></mml:mrow></mml:msup></mml:math></inline-formula>)</oasis:entry>

       </oasis:row>
       <oasis:row>

         <oasis:entry colname="col1"><inline-formula><mml:math display="inline"><mml:mrow><mml:mi mathvariant="italic">λ</mml:mi><mml:msubsup><mml:mi>E</mml:mi><mml:mtext>P</mml:mtext><mml:mo>*</mml:mo></mml:msubsup></mml:mrow></mml:math></inline-formula></oasis:entry>

         <oasis:entry colname="col2">Potential evaporation as flux according to Penman (W m<inline-formula><mml:math display="inline"><mml:msup><mml:mi/><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">2</mml:mn></mml:mrow></mml:msup></mml:math></inline-formula>)</oasis:entry>

       </oasis:row>
       <oasis:row>

         <oasis:entry colname="col1"><inline-formula><mml:math display="inline"><mml:mrow><mml:mi mathvariant="italic">λ</mml:mi><mml:msubsup><mml:mi>E</mml:mi><mml:mtext>PM</mml:mtext><mml:mo>*</mml:mo></mml:msubsup></mml:mrow></mml:math></inline-formula></oasis:entry>

         <oasis:entry colname="col2">Potential evaporation as flux according to Penman–Monteith (W m<inline-formula><mml:math display="inline"><mml:msup><mml:mi/><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">2</mml:mn></mml:mrow></mml:msup></mml:math></inline-formula>)</oasis:entry>

       </oasis:row>
       <oasis:row>

         <oasis:entry colname="col1"><inline-formula><mml:math display="inline"><mml:mrow><mml:mi mathvariant="italic">λ</mml:mi><mml:msubsup><mml:mi>E</mml:mi><mml:mtext>PT</mml:mtext><mml:mo>*</mml:mo></mml:msubsup></mml:mrow></mml:math></inline-formula></oasis:entry>

         <oasis:entry colname="col2">Potential evaporation as flux according to Priestley–Taylor (W m<inline-formula><mml:math display="inline"><mml:msup><mml:mi/><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">2</mml:mn></mml:mrow></mml:msup></mml:math></inline-formula>)</oasis:entry>

       </oasis:row>
       <oasis:row>

         <oasis:entry colname="col1"><inline-formula><mml:math display="inline"><mml:mrow><mml:msup><mml:mi>E</mml:mi><mml:mo>*</mml:mo></mml:msup></mml:mrow></mml:math></inline-formula></oasis:entry>

         <oasis:entry colname="col2">Potential evaporation as depth of water (mm)</oasis:entry>

       </oasis:row>
       <oasis:row>

         <oasis:entry colname="col1"><inline-formula><mml:math display="inline"><mml:mrow><mml:msubsup><mml:mi>E</mml:mi><mml:mtext>P</mml:mtext><mml:mo>*</mml:mo></mml:msubsup></mml:mrow></mml:math></inline-formula></oasis:entry>

         <oasis:entry colname="col2">Potential evaporation as depth of water according to Penman (mm)</oasis:entry>

       </oasis:row>
       <oasis:row>

         <oasis:entry colname="col1"><inline-formula><mml:math display="inline"><mml:mrow><mml:msubsup><mml:mi>E</mml:mi><mml:mtext>PM</mml:mtext><mml:mo>*</mml:mo></mml:msubsup></mml:mrow></mml:math></inline-formula></oasis:entry>

         <oasis:entry colname="col2">Potential evaporation as depth of water according to Penman–Monteith (mm)</oasis:entry>

       </oasis:row>
       <oasis:row>

         <oasis:entry colname="col1"><inline-formula><mml:math display="inline"><mml:mrow><mml:msubsup><mml:mi>E</mml:mi><mml:mtext>PT</mml:mtext><mml:mo>*</mml:mo></mml:msubsup></mml:mrow></mml:math></inline-formula></oasis:entry>

         <oasis:entry colname="col2">Potential evaporation as depth of water according to Priestley–Taylor (mm)</oasis:entry>

       </oasis:row>
       <oasis:row>

         <oasis:entry colname="col1"><inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>E</mml:mi><mml:mtext>W</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula></oasis:entry>

         <oasis:entry colname="col2">Wet environment evaporation as depth of water (mm)</oasis:entry>

       </oasis:row>
       <oasis:row>

         <oasis:entry colname="col1"><inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>g</mml:mi><mml:mtext>A</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula></oasis:entry>

         <oasis:entry colname="col2">Aerodynamic conductance (m s<inline-formula><mml:math display="inline"><mml:msup><mml:mi/><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:msup></mml:math></inline-formula>)</oasis:entry>

       </oasis:row>
       <oasis:row>

         <oasis:entry colname="col1"><inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>g</mml:mi><mml:mtext>C</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula></oasis:entry>

         <oasis:entry colname="col2">Stomatal/surface conductance (m s<inline-formula><mml:math display="inline"><mml:msup><mml:mi/><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:msup></mml:math></inline-formula>)</oasis:entry>

       </oasis:row>
       <oasis:row>

         <oasis:entry colname="col1"><inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>g</mml:mi><mml:mtext>M</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula></oasis:entry>

         <oasis:entry colname="col2">Momentum conductance (m s<inline-formula><mml:math display="inline"><mml:msup><mml:mi/><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:msup></mml:math></inline-formula>)</oasis:entry>

       </oasis:row>
       <oasis:row>

         <oasis:entry colname="col1"><inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>g</mml:mi><mml:mtext>B</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula></oasis:entry>

         <oasis:entry colname="col2">Quasi-laminar boundary-layer conductance (m s<inline-formula><mml:math display="inline"><mml:msup><mml:mi/><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:msup></mml:math></inline-formula>)</oasis:entry>

       </oasis:row>
       <oasis:row>

         <oasis:entry colname="col1"><inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>g</mml:mi><mml:mtext>Cmax</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula></oasis:entry>

         <oasis:entry colname="col2">Maximum stomatal/surface conductance (m s<inline-formula><mml:math display="inline"><mml:msup><mml:mi/><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:msup></mml:math></inline-formula>) (<inline-formula><mml:math display="inline"><mml:mo>=</mml:mo></mml:math></inline-formula> <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>g</mml:mi><mml:mtext>C</mml:mtext></mml:msub><mml:mo>/</mml:mo><mml:mi>M</mml:mi></mml:mrow></mml:math></inline-formula>)</oasis:entry>

       </oasis:row>
       <oasis:row>

         <oasis:entry colname="col1"><inline-formula><mml:math display="inline"><mml:mi>M</mml:mi></mml:math></inline-formula></oasis:entry>

         <oasis:entry colname="col2">Surface moisture availability (0–1)</oasis:entry>

       </oasis:row>
       <oasis:row>

         <oasis:entry colname="col1"><inline-formula><mml:math display="inline"><mml:mi>s</mml:mi></mml:math></inline-formula></oasis:entry>

         <oasis:entry colname="col2">Slope of saturation vapor pressure vs. temperature curve (hPa K<inline-formula><mml:math display="inline"><mml:mrow><mml:msup><mml:mi/><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:msup><mml:mo>)</mml:mo></mml:mrow></mml:math></inline-formula> (estimated at <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>T</mml:mi><mml:mtext>A</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula>)</oasis:entry>

       </oasis:row>
       <oasis:row>

         <oasis:entry colname="col1" morerows="1"><inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>s</mml:mi><mml:mn mathvariant="normal">1</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula></oasis:entry>

         <oasis:entry colname="col2">Slope of the saturation vapor pressure and temperature between (<inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>T</mml:mi><mml:mtext>SD</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> <inline-formula><mml:math display="inline"><mml:mo>-</mml:mo></mml:math></inline-formula> <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>T</mml:mi><mml:mtext>D</mml:mtext></mml:msub><mml:mo>)</mml:mo></mml:mrow></mml:math></inline-formula></oasis:entry>

       </oasis:row>
       <oasis:row>

         <oasis:entry colname="col2">vs. (<inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>e</mml:mi><mml:mn mathvariant="normal">0</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> <inline-formula><mml:math display="inline"><mml:mo>-</mml:mo></mml:math></inline-formula> <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>e</mml:mi><mml:mtext>A</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula>) (approximated at <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>T</mml:mi><mml:mtext>D</mml:mtext></mml:msub><mml:mo>)</mml:mo></mml:mrow></mml:math></inline-formula> (hPa K<inline-formula><mml:math display="inline"><mml:msup><mml:mi/><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:msup></mml:math></inline-formula>)</oasis:entry>

       </oasis:row>
       <oasis:row>

         <oasis:entry colname="col1" morerows="1"><inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>s</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula></oasis:entry>

         <oasis:entry colname="col2">Slope of the saturation vapor pressure and temperature between (<inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>T</mml:mi><mml:mtext>R</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> <inline-formula><mml:math display="inline"><mml:mo>-</mml:mo></mml:math></inline-formula> <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>T</mml:mi><mml:mtext>D</mml:mtext></mml:msub><mml:mo>)</mml:mo></mml:mrow></mml:math></inline-formula></oasis:entry>

       </oasis:row>
       <oasis:row>

         <oasis:entry colname="col2">vs. (<inline-formula><mml:math display="inline"><mml:mrow><mml:msubsup><mml:mi>e</mml:mi><mml:mtext>S</mml:mtext><mml:mo>*</mml:mo></mml:msubsup></mml:mrow></mml:math></inline-formula> <inline-formula><mml:math display="inline"><mml:mo>-</mml:mo></mml:math></inline-formula> <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>e</mml:mi><mml:mtext>A</mml:mtext></mml:msub><mml:mo>)</mml:mo></mml:mrow></mml:math></inline-formula> (hPa K<inline-formula><mml:math display="inline"><mml:msup><mml:mi/><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:msup></mml:math></inline-formula>), estimated according to Mallick et al. (2015)</oasis:entry>

       </oasis:row>
       <oasis:row>

         <oasis:entry colname="col1" morerows="1"><inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>s</mml:mi><mml:mn mathvariant="normal">3</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula></oasis:entry>

         <oasis:entry colname="col2">Slope of the saturation vapor pressure and temperature between (<inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>T</mml:mi><mml:mtext>R</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> <inline-formula><mml:math display="inline"><mml:mo>-</mml:mo></mml:math></inline-formula> <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>T</mml:mi><mml:mtext>SD</mml:mtext></mml:msub><mml:mo>)</mml:mo></mml:mrow></mml:math></inline-formula></oasis:entry>

       </oasis:row>
       <oasis:row>

         <oasis:entry colname="col2">vs. (<inline-formula><mml:math display="inline"><mml:mrow><mml:msubsup><mml:mi>e</mml:mi><mml:mtext>S</mml:mtext><mml:mo>*</mml:mo></mml:msubsup></mml:mrow></mml:math></inline-formula> <inline-formula><mml:math display="inline"><mml:mo>-</mml:mo></mml:math></inline-formula> <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>e</mml:mi><mml:mtext>S</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula>) (approximated at <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>T</mml:mi><mml:mtext>R</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula>) (hPa K<inline-formula><mml:math display="inline"><mml:msup><mml:mi/><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:msup></mml:math></inline-formula>)</oasis:entry>

       </oasis:row>
       <oasis:row>

         <oasis:entry colname="col1"><inline-formula><mml:math display="inline"><mml:mi>k</mml:mi></mml:math></inline-formula></oasis:entry>

         <oasis:entry colname="col2">Ratio between (<inline-formula><mml:math display="inline"><mml:mrow><mml:msubsup><mml:mi>e</mml:mi><mml:mn mathvariant="normal">0</mml:mn><mml:mo>*</mml:mo></mml:msubsup></mml:mrow></mml:math></inline-formula> <inline-formula><mml:math display="inline"><mml:mo>-</mml:mo></mml:math></inline-formula> <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>e</mml:mi><mml:mtext>A</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula>) and (<inline-formula><mml:math display="inline"><mml:mrow><mml:msubsup><mml:mi>e</mml:mi><mml:mtext>S</mml:mtext><mml:mo>*</mml:mo></mml:msubsup></mml:mrow></mml:math></inline-formula> <inline-formula><mml:math display="inline"><mml:mo>-</mml:mo></mml:math></inline-formula> <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>e</mml:mi><mml:mtext>A</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula>)</oasis:entry>

       </oasis:row>
       <oasis:row>

         <oasis:entry colname="col1"><inline-formula><mml:math display="inline"><mml:mi mathvariant="italic">λ</mml:mi></mml:math></inline-formula></oasis:entry>

         <oasis:entry colname="col2">Latent heat of vaporization of water (J kg<inline-formula><mml:math display="inline"><mml:msup><mml:mi/><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:msup></mml:math></inline-formula> K<inline-formula><mml:math display="inline"><mml:msup><mml:mi/><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:msup></mml:math></inline-formula>)</oasis:entry>

       </oasis:row>
       <oasis:row>

         <oasis:entry colname="col1"><inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>z</mml:mi><mml:mtext>R</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula></oasis:entry>

         <oasis:entry colname="col2">Reference height (m)</oasis:entry>

       </oasis:row>
     </oasis:tbody>
   </oasis:tgroup></oasis:table></table-wrap>

<?xmltex \hack{\addtocounter{table}{-1}}?><?xmltex \floatpos{t}?><table-wrap id="Ch1.T2"><caption><p>Continued.</p></caption><oasis:table frame="topbot"><oasis:tgroup cols="2">
     <oasis:colspec colnum="1" colname="col1" align="left"/>
     <oasis:colspec colnum="2" colname="col2" align="left"/>
     <oasis:thead>
       <oasis:row>  
         <oasis:entry colname="col1">Variables</oasis:entry>  
         <oasis:entry colname="col2">Description</oasis:entry>
       </oasis:row>
       <oasis:row>  
         <oasis:entry colname="col1">and</oasis:entry>  
         <oasis:entry colname="col2"/>
       </oasis:row>
       <oasis:row rowsep="1">  
         <oasis:entry colname="col1">symbols</oasis:entry>  
         <oasis:entry colname="col2"/>
       </oasis:row>
     </oasis:thead>
     <oasis:tbody>
       <oasis:row>  
         <oasis:entry colname="col1"><inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>z</mml:mi><mml:mtext>M</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula></oasis:entry>  
         <oasis:entry colname="col2">Effective source–sink height of momentum (m)</oasis:entry>
       </oasis:row>
       <oasis:row>  
         <oasis:entry colname="col1"><inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>z</mml:mi><mml:mn mathvariant="normal">0</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula></oasis:entry>  
         <oasis:entry colname="col2">Roughness length (m)</oasis:entry>
       </oasis:row>
       <oasis:row>  
         <oasis:entry colname="col1"><inline-formula><mml:math display="inline"><mml:mi>d</mml:mi></mml:math></inline-formula></oasis:entry>  
         <oasis:entry colname="col2">Displacement height (m)</oasis:entry>
       </oasis:row>
       <oasis:row>  
         <oasis:entry colname="col1"><inline-formula><mml:math display="inline"><mml:mi mathvariant="italic">γ</mml:mi></mml:math></inline-formula></oasis:entry>  
         <oasis:entry colname="col2">Psychrometric constant (hPa K<inline-formula><mml:math display="inline"><mml:msup><mml:mi/><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:msup></mml:math></inline-formula>)</oasis:entry>
       </oasis:row>
       <oasis:row>  
         <oasis:entry colname="col1"><inline-formula><mml:math display="inline"><mml:mi mathvariant="italic">ρ</mml:mi></mml:math></inline-formula></oasis:entry>  
         <oasis:entry colname="col2">Density of air (kg m<inline-formula><mml:math display="inline"><mml:msup><mml:mi/><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">3</mml:mn></mml:mrow></mml:msup></mml:math></inline-formula>)</oasis:entry>
       </oasis:row>
       <oasis:row>  
         <oasis:entry colname="col1"><inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>c</mml:mi><mml:mi>p</mml:mi></mml:msub></mml:mrow></mml:math></inline-formula></oasis:entry>  
         <oasis:entry colname="col2">Specific heat of dry air (MJ kg<inline-formula><mml:math display="inline"><mml:msup><mml:mi/><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:msup></mml:math></inline-formula> K<inline-formula><mml:math display="inline"><mml:msup><mml:mi/><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:msup></mml:math></inline-formula>)</oasis:entry>
       </oasis:row>
       <oasis:row>  
         <oasis:entry colname="col1"><inline-formula><mml:math display="inline"><mml:mi mathvariant="normal">Λ</mml:mi></mml:math></inline-formula></oasis:entry>  
         <oasis:entry colname="col2">Evaporative fraction (unitless)</oasis:entry>
       </oasis:row>
       <oasis:row>  
         <oasis:entry colname="col1"><inline-formula><mml:math display="inline"><mml:mi mathvariant="italic">β</mml:mi></mml:math></inline-formula></oasis:entry>  
         <oasis:entry colname="col2">Bowen ratio (unitless)</oasis:entry>
       </oasis:row>
       <oasis:row>  
         <oasis:entry colname="col1"><inline-formula><mml:math display="inline"><mml:mi mathvariant="italic">α</mml:mi></mml:math></inline-formula></oasis:entry>  
         <oasis:entry colname="col2">Priestley–Taylor parameter (unitless)</oasis:entry>
       </oasis:row>
       <oasis:row>  
         <oasis:entry colname="col1"><inline-formula><mml:math display="inline"><mml:mi mathvariant="normal">Ω</mml:mi></mml:math></inline-formula></oasis:entry>  
         <oasis:entry colname="col2">Decoupling coefficient (unitless)</oasis:entry>
       </oasis:row>
       <oasis:row>  
         <oasis:entry colname="col1"><italic>Sc</italic></oasis:entry>  
         <oasis:entry colname="col2">Schmidt number (unitless)</oasis:entry>
       </oasis:row>
       <oasis:row>  
         <oasis:entry colname="col1"><italic>Pr</italic></oasis:entry>  
         <oasis:entry colname="col2">Prandtl number (unitless)</oasis:entry>
       </oasis:row>
       <oasis:row>  
         <oasis:entry colname="col1"><inline-formula><mml:math display="inline"><mml:mi mathvariant="italic">κ</mml:mi></mml:math></inline-formula></oasis:entry>  
         <oasis:entry colname="col2">von Kármán constant (0.4)</oasis:entry>
       </oasis:row>
     </oasis:tbody>
   </oasis:tgroup></oasis:table></table-wrap>

      <p>The foundation of the development of STIC is based on the goal of finding an
analytical solution of the two unobserved “state variables” (<inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>g</mml:mi><mml:mtext>A</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula>
and <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>g</mml:mi><mml:mtext>C</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula>) in the PM equation while exploiting the radiative
(<inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>R</mml:mi><mml:mtext>N</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> and <inline-formula><mml:math display="inline"><mml:mrow><mml:mi>G</mml:mi><mml:mo>)</mml:mo></mml:mrow></mml:math></inline-formula>, meteorological (<inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>T</mml:mi><mml:mtext>A</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula>, <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>R</mml:mi><mml:mtext>H</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula>), and radiometric
surface temperature (<inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>T</mml:mi><mml:mtext>R</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula>) as external inputs. The fundamental
assumption in STIC is the first-order dependence of <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>g</mml:mi><mml:mtext>A</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> and
<inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>g</mml:mi><mml:mtext>C</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> on the aerodynamic temperature (<inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>T</mml:mi><mml:mn mathvariant="normal">0</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula>) and soil moisture
(through <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>T</mml:mi><mml:mtext>R</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula>). This assumption allows a direct integration of
<inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>T</mml:mi><mml:mtext>R</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> into the PM equation while simultaneously constraining the
conductances through <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>T</mml:mi><mml:mtext>R</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula>. Although the <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>T</mml:mi><mml:mtext>R</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> signal is
implicit in <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>R</mml:mi><mml:mtext>N</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula>, which appears in the numerator of the PM equation
(Eq. 1), it may be noted that <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>R</mml:mi><mml:mtext>N</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> has a relatively weak dependence
on <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>T</mml:mi><mml:mtext>R</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> (compared to the sensitivity of <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>T</mml:mi><mml:mtext>R</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> to soil moisture
and <inline-formula><mml:math display="inline"><mml:mrow><mml:mi mathvariant="italic">λ</mml:mi><mml:mi>E</mml:mi></mml:mrow></mml:math></inline-formula>). Given that <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>T</mml:mi><mml:mtext>R</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> is a direct signature of the soil
moisture availability, inclusion of <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>T</mml:mi><mml:mtext>R</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> in the PM equation also
works to add water-stress controls in <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>g</mml:mi><mml:mtext>C</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula>. Until now the explicit
use of <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>T</mml:mi><mml:mtext>R</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> in the PM model was hindered due to the unavailability of
any direct method to integrate <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>T</mml:mi><mml:mtext>R</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> into this model, and,
furthermore, due to the lack of physical models expressing biophysical states
of vegetation as a function of <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>T</mml:mi><mml:mtext>R</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula>. Therefore, the majority of the
PM-based <inline-formula><mml:math display="inline"><mml:mrow><mml:mi mathvariant="italic">λ</mml:mi><mml:mi>E</mml:mi></mml:mrow></mml:math></inline-formula> modeling approaches strongly rely on surface
reflectance and meteorology while exploiting the empirical leaf-scale
parameterizations of the biophysical conductances (Prihodko et al., 2008;
Bonan et al., 2014; Ershadi et al., 2015).</p>
      <p>The PM equation is commonly expressed as

                <disp-formula id="Ch1.E1" content-type="numbered"><mml:math display="block"><mml:mrow><mml:mi mathvariant="italic">λ</mml:mi><mml:mi>E</mml:mi><mml:mo>=</mml:mo><mml:mstyle displaystyle="true"><mml:mfrac style="display"><mml:mrow><mml:mi>s</mml:mi><mml:mi mathvariant="italic">ϕ</mml:mi><mml:mo>+</mml:mo><mml:mi mathvariant="italic">ρ</mml:mi><mml:mspace linebreak="nobreak" width="0.125em"/><mml:msub><mml:mi>c</mml:mi><mml:mi>P</mml:mi></mml:msub><mml:mspace width="0.125em" linebreak="nobreak"/><mml:msub><mml:mi>g</mml:mi><mml:mtext>A</mml:mtext></mml:msub><mml:msub><mml:mi>D</mml:mi><mml:mtext>A</mml:mtext></mml:msub></mml:mrow><mml:mrow><mml:mi>s</mml:mi><mml:mo>+</mml:mo><mml:mi mathvariant="italic">γ</mml:mi><mml:mfenced open="(" close=")"><mml:mn mathvariant="normal">1</mml:mn><mml:mo>+</mml:mo><mml:mstyle displaystyle="false"><mml:mfrac style="text"><mml:mrow><mml:msub><mml:mi>g</mml:mi><mml:mtext>A</mml:mtext></mml:msub></mml:mrow><mml:mrow><mml:msub><mml:mi>g</mml:mi><mml:mtext>C</mml:mtext></mml:msub></mml:mrow></mml:mfrac></mml:mstyle></mml:mfenced></mml:mrow></mml:mfrac></mml:mstyle><mml:mo>,</mml:mo></mml:mrow></mml:math></disp-formula>

          where <inline-formula><mml:math display="inline"><mml:mi mathvariant="italic">ρ</mml:mi></mml:math></inline-formula> is the air density (kg m<inline-formula><mml:math display="inline"><mml:msup><mml:mi/><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">3</mml:mn></mml:mrow></mml:msup></mml:math></inline-formula>), <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>c</mml:mi><mml:mi>P</mml:mi></mml:msub></mml:mrow></mml:math></inline-formula> is the specific heat of
air (J kg<inline-formula><mml:math display="inline"><mml:msup><mml:mi/><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:msup></mml:math></inline-formula> K<inline-formula><mml:math display="inline"><mml:msup><mml:mi/><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:msup></mml:math></inline-formula>), <inline-formula><mml:math display="inline"><mml:mi mathvariant="italic">γ</mml:mi></mml:math></inline-formula> is the psychrometric constant
(hPa K<inline-formula><mml:math display="inline"><mml:msup><mml:mi/><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:msup></mml:math></inline-formula>), <inline-formula><mml:math display="inline"><mml:mi>s</mml:mi></mml:math></inline-formula> is the slope of the saturation vapor pressure vs. air
temperature (hPa K<inline-formula><mml:math display="inline"><mml:msup><mml:mi/><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:msup></mml:math></inline-formula>), <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>D</mml:mi><mml:mtext>A</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> is the saturation deficit of the
air (hPa) or vapor pressure deficit at the reference level, and <inline-formula><mml:math display="inline"><mml:mi mathvariant="italic">ϕ</mml:mi></mml:math></inline-formula> is the
net available energy (W m<inline-formula><mml:math display="inline"><mml:msup><mml:mi/><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">2</mml:mn></mml:mrow></mml:msup></mml:math></inline-formula>) (the difference between <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>R</mml:mi><mml:mtext>N</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> and
<inline-formula><mml:math display="inline"><mml:mi>G</mml:mi></mml:math></inline-formula>). The units of all the surface fluxes and conductances are in W m<inline-formula><mml:math display="inline"><mml:msup><mml:mi/><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">2</mml:mn></mml:mrow></mml:msup></mml:math></inline-formula>
and m s<inline-formula><mml:math display="inline"><mml:msup><mml:mi/><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:msup></mml:math></inline-formula>, respectively. For a dense canopy, <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>g</mml:mi><mml:mtext>C</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> in the PM
equation represents the canopy surface conductance. Although it is not equal
to the canopy stomatal conductance, it contains integrated information on the
stomata. For a heterogeneous landscape, <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>g</mml:mi><mml:mtext>C</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> in the PM equation is an
aggregated surface conductance containing information on both canopy and
soil. Traditionally, the two unknown “state variables” in Eq. (1) are
<inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>g</mml:mi><mml:mtext>A</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> and <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>g</mml:mi><mml:mtext>C</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula>, and the STIC methodology is based on
formulating “state equations” for these conductances that satisfy the PM
model (Mallick et al., 2014, 2015). The PM equation is “closed” upon the
availability of canopy-scale measurements of the two unobserved biophysical
conductances, and if we assume the empirical models of <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>g</mml:mi><mml:mtext>A</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> and
<inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>g</mml:mi><mml:mtext>C</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> to be reliable. However, neither <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>g</mml:mi><mml:mtext>A</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> nor <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>g</mml:mi><mml:mtext>C</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula>
can be measured at the canopy scale or at larger spatial scales. Furthermore,
as shown by some recent studies (Matheny et al., 2014; Van Dijk et al.,
2015), a more appropriate <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>g</mml:mi><mml:mtext>A</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> and <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>g</mml:mi><mml:mtext>C</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> model is currently
not available. This implies that a true “closure” of the PM equation is
only possible through an analytical estimation of the conductances.</p>
</sec>
<sec id="Ch1.S2.SS2">
  <title>State equations</title>
      <p>By integrating <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>T</mml:mi><mml:mtext>R</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> with standard surface energy balance (SEB) theory
and vegetation biophysical principles, STIC formulates multiple “state
equations” that eliminate the need for exogenous parametric submodels for
<inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>g</mml:mi><mml:mtext>A</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> and <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>g</mml:mi><mml:mtext>C</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula>, associated aerodynamic variables, and
land–atmosphere coupling. The state equations of STIC are as follows and
their detailed derivations are described in Appendix A1.

                <disp-formula specific-use="align" content-type="numbered"><mml:math display="block"><mml:mtable displaystyle="true"><mml:mlabeledtr id="Ch1.E2"><mml:mtd/><mml:mtd/><mml:mtd><mml:mrow><mml:msub><mml:mi>g</mml:mi><mml:mtext>A</mml:mtext></mml:msub><mml:mo>=</mml:mo><mml:mstyle displaystyle="true"><mml:mfrac style="display"><mml:mi mathvariant="italic">ϕ</mml:mi><mml:mrow><mml:mi mathvariant="italic">ρ</mml:mi><mml:msub><mml:mi>c</mml:mi><mml:mi>P</mml:mi></mml:msub><mml:mfenced close="]" open="["><mml:mfenced close=")" open="("><mml:msub><mml:mi>T</mml:mi><mml:mn mathvariant="normal">0</mml:mn></mml:msub><mml:mo>-</mml:mo><mml:msub><mml:mi>T</mml:mi><mml:mtext>A</mml:mtext></mml:msub></mml:mfenced><mml:mo>+</mml:mo><mml:mfenced close=")" open="("><mml:mstyle displaystyle="false"><mml:mfrac style="text"><mml:mrow><mml:msub><mml:mi>e</mml:mi><mml:mn mathvariant="normal">0</mml:mn></mml:msub><mml:mo>-</mml:mo><mml:msub><mml:mi>e</mml:mi><mml:mtext>A</mml:mtext></mml:msub></mml:mrow><mml:mi mathvariant="italic">γ</mml:mi></mml:mfrac></mml:mstyle></mml:mfenced></mml:mfenced></mml:mrow></mml:mfrac></mml:mstyle></mml:mrow></mml:mtd></mml:mlabeledtr><mml:mlabeledtr id="Ch1.E3"><mml:mtd/><mml:mtd/><mml:mtd><mml:mrow><mml:msub><mml:mi>g</mml:mi><mml:mtext>C</mml:mtext></mml:msub><mml:mo>=</mml:mo><mml:msub><mml:mi>g</mml:mi><mml:mtext>A</mml:mtext></mml:msub><mml:mstyle displaystyle="true"><mml:mfrac style="display"><mml:mrow><mml:mfenced open="(" close=")"><mml:msub><mml:mi>e</mml:mi><mml:mn mathvariant="normal">0</mml:mn></mml:msub><mml:mo>-</mml:mo><mml:msub><mml:mi>e</mml:mi><mml:mtext>A</mml:mtext></mml:msub></mml:mfenced></mml:mrow><mml:mrow><mml:mfenced open="(" close=")"><mml:msubsup><mml:mi>e</mml:mi><mml:mn mathvariant="normal">0</mml:mn><mml:mo>*</mml:mo></mml:msubsup><mml:mo>-</mml:mo><mml:msub><mml:mi>e</mml:mi><mml:mn mathvariant="normal">0</mml:mn></mml:msub></mml:mfenced></mml:mrow></mml:mfrac></mml:mstyle></mml:mrow></mml:mtd></mml:mlabeledtr><mml:mlabeledtr id="Ch1.E4"><mml:mtd/><mml:mtd/><mml:mtd><mml:mrow><mml:msub><mml:mi>T</mml:mi><mml:mn mathvariant="normal">0</mml:mn></mml:msub><mml:mo>=</mml:mo><mml:msub><mml:mi>T</mml:mi><mml:mtext>A</mml:mtext></mml:msub><mml:mo>+</mml:mo><mml:mfenced close=")" open="("><mml:mstyle displaystyle="true"><mml:mfrac style="display"><mml:mrow><mml:msub><mml:mi>e</mml:mi><mml:mn mathvariant="normal">0</mml:mn></mml:msub><mml:mo>-</mml:mo><mml:msub><mml:mi>e</mml:mi><mml:mtext>A</mml:mtext></mml:msub></mml:mrow><mml:mi mathvariant="italic">γ</mml:mi></mml:mfrac></mml:mstyle></mml:mfenced><mml:mfenced close=")" open="("><mml:mstyle displaystyle="true"><mml:mfrac style="display"><mml:mrow><mml:mn mathvariant="normal">1</mml:mn><mml:mo>-</mml:mo><mml:mi mathvariant="normal">Λ</mml:mi></mml:mrow><mml:mi mathvariant="normal">Λ</mml:mi></mml:mfrac></mml:mstyle></mml:mfenced></mml:mrow></mml:mtd></mml:mlabeledtr><mml:mlabeledtr id="Ch1.E5"><mml:mtd/><mml:mtd/><mml:mtd><mml:mrow><mml:mi mathvariant="normal">Λ</mml:mi><mml:mo>=</mml:mo><mml:mstyle displaystyle="true"><mml:mfrac style="display"><mml:mrow><mml:mn mathvariant="normal">2</mml:mn><mml:mi mathvariant="italic">α</mml:mi><mml:mi>s</mml:mi></mml:mrow><mml:mrow><mml:mn mathvariant="normal">2</mml:mn><mml:mi>s</mml:mi><mml:mo>+</mml:mo><mml:mn mathvariant="normal">2</mml:mn><mml:mi mathvariant="italic">γ</mml:mi><mml:mo>+</mml:mo><mml:mi mathvariant="italic">γ</mml:mi><mml:mstyle displaystyle="false"><mml:mfrac style="text"><mml:mrow><mml:msub><mml:mi>g</mml:mi><mml:mtext>A</mml:mtext></mml:msub></mml:mrow><mml:mrow><mml:msub><mml:mi>g</mml:mi><mml:mtext>C</mml:mtext></mml:msub></mml:mrow></mml:mfrac></mml:mstyle><mml:mo>(</mml:mo><mml:mn mathvariant="normal">1</mml:mn><mml:mo>+</mml:mo><mml:mi>M</mml:mi><mml:mo>)</mml:mo></mml:mrow></mml:mfrac></mml:mstyle></mml:mrow></mml:mtd></mml:mlabeledtr></mml:mtable></mml:math></disp-formula>

            Here, <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>T</mml:mi><mml:mn mathvariant="normal">0</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> is the temperature (<inline-formula><mml:math display="inline"><mml:msup><mml:mi/><mml:mo>∘</mml:mo></mml:msup></mml:math></inline-formula>C) at the source/sink height (or
at the roughness length (<inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>z</mml:mi><mml:mn mathvariant="normal">0</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula>) or in-canopy air stream), <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>e</mml:mi><mml:mn mathvariant="normal">0</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> is the
atmospheric vapor pressure (hPa) at the source/sink height, <inline-formula><mml:math display="inline"><mml:mrow><mml:msubsup><mml:mi>e</mml:mi><mml:mn mathvariant="normal">0</mml:mn><mml:mo>*</mml:mo></mml:msubsup></mml:mrow></mml:math></inline-formula> is
the saturation vapor pressure (hPa) at the source/sink height, <inline-formula><mml:math display="inline"><mml:mi mathvariant="normal">Λ</mml:mi></mml:math></inline-formula> is
the evaporative fraction (the ratio of <inline-formula><mml:math display="inline"><mml:mrow><mml:mi mathvariant="italic">λ</mml:mi><mml:mi>E</mml:mi></mml:mrow></mml:math></inline-formula> and <inline-formula><mml:math display="inline"><mml:mi mathvariant="italic">ϕ</mml:mi></mml:math></inline-formula>), <inline-formula><mml:math display="inline"><mml:mi mathvariant="italic">α</mml:mi></mml:math></inline-formula> is
the Priestley–Taylor parameter (unitless) (Priestley and Taylor, 1972), and
<inline-formula><mml:math display="inline"><mml:mi>M</mml:mi></mml:math></inline-formula> is a unitless quantity that describes the relative wetness (or moisture
availability) of the surface. <inline-formula><mml:math display="inline"><mml:mi>M</mml:mi></mml:math></inline-formula> controls the transition from potential to
actual evaporation and hence is critical for providing a constraint against
which the conductances can be estimated (<inline-formula><mml:math display="inline"><mml:mi>M</mml:mi></mml:math></inline-formula> estimation is explained in
Appendix A2). Given values of <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>R</mml:mi><mml:mtext>N</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula>, <inline-formula><mml:math display="inline"><mml:mi>G</mml:mi></mml:math></inline-formula>, <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>T</mml:mi><mml:mtext>A</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula>, and <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>R</mml:mi><mml:mtext>H</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> or
<inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>e</mml:mi><mml:mtext>A</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula>, the four state equations (Eqs. 2–5) can be solved
simultaneously to derive analytical solutions for the four state variables.
This also produces a “closure” of the PM model, which is independent of
empirical parameterizations for both <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>g</mml:mi><mml:mtext>A</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> and <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>g</mml:mi><mml:mtext>C</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula>. However,
the analytical solutions to the above state equations have four accompanying
unknowns, <inline-formula><mml:math display="inline"><mml:mi>M</mml:mi></mml:math></inline-formula> (surface moisture availability), <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>e</mml:mi><mml:mn mathvariant="normal">0</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> (vapor pressure at the
source/sink height), <inline-formula><mml:math display="inline"><mml:mrow><mml:msubsup><mml:mi>e</mml:mi><mml:mn mathvariant="normal">0</mml:mn><mml:mo>*</mml:mo></mml:msubsup></mml:mrow></mml:math></inline-formula> (saturation vapor pressure at the
source/sink height), and the Priestley–Taylor coefficient (<inline-formula><mml:math display="inline"><mml:mi mathvariant="italic">α</mml:mi></mml:math></inline-formula>), and as
a result there are four equations with eight unknowns. Consequently an
iterative solution is needed to determine the four unknown variables (as
described in Appendix A2), which is a further modification of the STIC1.1
framework (Mallick et al., 2015). The present version of STIC is designated
as STIC1.2 and its uniqueness is the physical integration of <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>T</mml:mi><mml:mtext>R</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula>
into a combined structure of the PM and Shuttleworth–Wallace (SW, hereafter)
(Shuttleworth and Wallace, 1985) models to estimate the source/sink height
vapor pressures (Appendix A2). In addition to physically integrating
<inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>T</mml:mi><mml:mtext>R</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> observations into a combined PM–SW framework, STIC1.2 also
establishes a feedback loop describing the relationship between <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>T</mml:mi><mml:mtext>R</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula>
and <inline-formula><mml:math display="inline"><mml:mrow><mml:mi mathvariant="italic">λ</mml:mi><mml:mi>E</mml:mi></mml:mrow></mml:math></inline-formula>, coupled with canopy–atmosphere components relating
<inline-formula><mml:math display="inline"><mml:mrow><mml:mi mathvariant="italic">λ</mml:mi><mml:mi>E</mml:mi></mml:mrow></mml:math></inline-formula> to <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>T</mml:mi><mml:mn mathvariant="normal">0</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> and <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>e</mml:mi><mml:mn mathvariant="normal">0</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula>. To estimate <inline-formula><mml:math display="inline"><mml:mi>M</mml:mi></mml:math></inline-formula>, the radiometric surface
temperature (<inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>T</mml:mi><mml:mtext>R</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula>) is extensively used in a physical retrieval
framework, thus treating <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>T</mml:mi><mml:mtext>R</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> as an external input. In Eq. (5), the
Priestley–Taylor coefficient (<inline-formula><mml:math display="inline"><mml:mi mathvariant="italic">α</mml:mi></mml:math></inline-formula>) appeared due to the use of the
advection–aridity (AA) hypothesis (Brutsaert and Stricker, 1979) for
deriving the state equation of <inline-formula><mml:math display="inline"><mml:mi mathvariant="normal">Λ</mml:mi></mml:math></inline-formula> (Supplement S1). However, instead of
optimizing <inline-formula><mml:math display="inline"><mml:mi mathvariant="italic">α</mml:mi></mml:math></inline-formula> as a “fixed parameter”, we have developed a physical
equation of <inline-formula><mml:math display="inline"><mml:mi mathvariant="italic">α</mml:mi></mml:math></inline-formula> (Eq. A15) and numerically estimated <inline-formula><mml:math display="inline"><mml:mi mathvariant="italic">α</mml:mi></mml:math></inline-formula> as a
“variable”. The derivation of the equation for <inline-formula><mml:math display="inline"><mml:mi mathvariant="italic">α</mml:mi></mml:math></inline-formula> is described in
Appendix A2. The fundamental differences between STIC1.2 and earlier versions
are described in Table A1.</p>
      <p>In STIC1.2, <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>T</mml:mi><mml:mn mathvariant="normal">0</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> is a function of <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>T</mml:mi><mml:mtext>R</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula>, and they are not assumed
equal (<inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>T</mml:mi><mml:mn mathvariant="normal">0</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> <inline-formula><mml:math display="inline"><mml:mo>≠</mml:mo></mml:math></inline-formula> <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>T</mml:mi><mml:mtext>R</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula>). The analytical expression of <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>T</mml:mi><mml:mn mathvariant="normal">0</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> is
dependent on <inline-formula><mml:math display="inline"><mml:mi>M</mml:mi></mml:math></inline-formula> and the estimation of <inline-formula><mml:math display="inline"><mml:mi>M</mml:mi></mml:math></inline-formula> is based on <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>T</mml:mi><mml:mtext>R</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula>. To
further elaborate this point on the inequality of <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>T</mml:mi><mml:mn mathvariant="normal">0</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> and <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>T</mml:mi><mml:mtext>R</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula>,
we show an intercomparison of retrieved <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>T</mml:mi><mml:mn mathvariant="normal">0</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> vs. <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>T</mml:mi><mml:mtext>R</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> for forest
and pasture (Fig. A2). This indicates the distinct difference of the
retrieved <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>T</mml:mi><mml:mn mathvariant="normal">0</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> from <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>T</mml:mi><mml:mtext>R</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> for the two different biomes.</p>
</sec>
<sec id="Ch1.S2.SS3">
  <?xmltex \opttitle{Partitioning $\lambda{E}$}?><title>Partitioning <inline-formula><mml:math display="inline"><mml:mrow><mml:mi mathvariant="italic">λ</mml:mi><mml:mi>E</mml:mi></mml:mrow></mml:math></inline-formula></title>
      <p>The terrestrial latent heat flux is an aggregate of both
transpiration (<inline-formula><mml:math display="inline"><mml:mrow><mml:mi mathvariant="italic">λ</mml:mi><mml:msub><mml:mi>E</mml:mi><mml:mtext>T</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula>) and evaporation (<inline-formula><mml:math display="inline"><mml:mrow><mml:mi mathvariant="italic">λ</mml:mi><mml:msub><mml:mi>E</mml:mi><mml:mtext>E</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula>)
(sum of soil evaporation and interception evaporation from the canopy).
During rain events the land surface becomes wet and <inline-formula><mml:math display="inline"><mml:mrow><mml:mi mathvariant="italic">λ</mml:mi><mml:mi>E</mml:mi></mml:mrow></mml:math></inline-formula> tends to
approach the potential evaporation (<inline-formula><mml:math display="inline"><mml:mrow><mml:mi mathvariant="italic">λ</mml:mi><mml:msup><mml:mi>E</mml:mi><mml:mo>*</mml:mo></mml:msup></mml:mrow></mml:math></inline-formula>), while surface drying
after rainfall causes <inline-formula><mml:math display="inline"><mml:mrow><mml:mi mathvariant="italic">λ</mml:mi><mml:mi>E</mml:mi></mml:mrow></mml:math></inline-formula> to approach the potential transpiration
rate (<inline-formula><mml:math display="inline"><mml:mrow><mml:mi mathvariant="italic">λ</mml:mi><mml:msubsup><mml:mi>E</mml:mi><mml:mtext>T</mml:mtext><mml:mo>*</mml:mo></mml:msubsup></mml:mrow></mml:math></inline-formula>) in the presence of vegetation, or zero
without any vegetation. Hence, <inline-formula><mml:math display="inline"><mml:mrow><mml:mi mathvariant="italic">λ</mml:mi><mml:mi>E</mml:mi></mml:mrow></mml:math></inline-formula> at any time is a mixture of these
two end-member conditions depending on the degree of surface moisture
availability or wetness (<inline-formula><mml:math display="inline"><mml:mi>M</mml:mi></mml:math></inline-formula>) (Bosveld and Bouten, 2003; Loescher et al.,
2005). Considering the general case of evaporation from an unsaturated
surface at a rate less than the potential, <inline-formula><mml:math display="inline"><mml:mi>M</mml:mi></mml:math></inline-formula> is the ratio of the actual to
potential evaporation rate and is considered as an index of evaporation
efficiency during a given time interval (Boulet et al., 2015). Partitioning
of <inline-formula><mml:math display="inline"><mml:mrow><mml:mi mathvariant="italic">λ</mml:mi><mml:mi>E</mml:mi></mml:mrow></mml:math></inline-formula> into <inline-formula><mml:math display="inline"><mml:mrow><mml:mi mathvariant="italic">λ</mml:mi><mml:msub><mml:mi>E</mml:mi><mml:mtext>E</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> and <inline-formula><mml:math display="inline"><mml:mrow><mml:mi mathvariant="italic">λ</mml:mi><mml:msub><mml:mi>E</mml:mi><mml:mtext>T</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> was
performed according to Mallick et al. (2014) as follows:

                <disp-formula id="Ch1.E6" content-type="numbered"><mml:math display="block"><mml:mrow><mml:mi mathvariant="italic">λ</mml:mi><mml:mi>E</mml:mi><mml:mo>=</mml:mo><mml:mi mathvariant="italic">λ</mml:mi><mml:msub><mml:mi>E</mml:mi><mml:mtext>E</mml:mtext></mml:msub><mml:mo>+</mml:mo><mml:mi mathvariant="italic">λ</mml:mi><mml:msub><mml:mi>E</mml:mi><mml:mtext>T</mml:mtext></mml:msub><mml:mo>=</mml:mo><mml:mi>M</mml:mi><mml:mi mathvariant="italic">λ</mml:mi><mml:msup><mml:mi>E</mml:mi><mml:mo>*</mml:mo></mml:msup><mml:mo>+</mml:mo><mml:mo>(</mml:mo><mml:mn mathvariant="normal">1</mml:mn><mml:mo>-</mml:mo><mml:mi>M</mml:mi><mml:mo>)</mml:mo><mml:mi mathvariant="italic">λ</mml:mi><mml:msubsup><mml:mi>E</mml:mi><mml:mtext>T</mml:mtext><mml:mo>*</mml:mo></mml:msubsup><mml:mo>.</mml:mo></mml:mrow></mml:math></disp-formula>

          The estimates of <inline-formula><mml:math display="inline"><mml:mrow><mml:mi mathvariant="italic">λ</mml:mi><mml:msub><mml:mi>E</mml:mi><mml:mtext>E</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> in the current method consist of an
aggregated contribution from both interception and soil evaporation, and no
further attempt is made to separate these two components. In the Amazon
forest, soil evaporation has a negligible contribution, while the
interception evaporation contributes substantially to the total evaporative
fluxes, and therefore the partitioning of <inline-formula><mml:math display="inline"><mml:mrow><mml:mi mathvariant="italic">λ</mml:mi><mml:mi>E</mml:mi></mml:mrow></mml:math></inline-formula> into
<inline-formula><mml:math display="inline"><mml:mrow><mml:mi mathvariant="italic">λ</mml:mi><mml:msub><mml:mi>E</mml:mi><mml:mtext>E</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> and <inline-formula><mml:math display="inline"><mml:mrow><mml:mi mathvariant="italic">λ</mml:mi><mml:msub><mml:mi>E</mml:mi><mml:mtext>T</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> is crucial. After estimating
<inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>g</mml:mi><mml:mtext>A</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula>, <inline-formula><mml:math display="inline"><mml:mrow><mml:mi mathvariant="italic">λ</mml:mi><mml:msup><mml:mi>E</mml:mi><mml:mo>*</mml:mo></mml:msup></mml:mrow></mml:math></inline-formula> was estimated according to the Penman equation
(Penman, 1948) and <inline-formula><mml:math display="inline"><mml:mrow><mml:mi mathvariant="italic">λ</mml:mi><mml:msub><mml:mi>E</mml:mi><mml:mtext>T</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> was estimated as the residual in
Eq. (6).</p>
      <p>In this study, we use the term “canopy conductance” instead of “stomatal
conductance” given that the term “stomata” is applicable at the leaf scale
only. As stated earlier, for a heterogeneous surface, <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>g</mml:mi><mml:mtext>C</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> should
principally be a mixture of the canopy surface (integrated stomatal
information) and soil conductances. However, given the high vegetation
density of the Amazon Basin, the soil surface exposure is negligible, and
hence we assume <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>g</mml:mi><mml:mtext>C</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> to be the canopy-scale aggregate of the stomatal
conductance. Similarly, a different <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>g</mml:mi><mml:mtext>A</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> exists for soil–canopy,
sun–shade, and dry–wet conditions (Leuning, 1995), which are currently
integrated into a lumped <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>g</mml:mi><mml:mtext>A</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> (given the big-leaf nature of STIC).
From the big-leaf perspective, it is generally assumed that the aerodynamic
conductance of water vapor and heat are equal (Raupach, 1998). However, to
obtain partitioned aerodynamic conductances, explicit partitioning of
<inline-formula><mml:math display="inline"><mml:mrow><mml:mi mathvariant="italic">λ</mml:mi><mml:mi>E</mml:mi></mml:mrow></mml:math></inline-formula> is needed, which is beyond the scope of the current paper.</p>
</sec>
<sec id="Ch1.S2.SS4">
  <?xmltex \opttitle{Evaluating $g_{\text{A}}$ and $g_{\text{C}}$}?><title>Evaluating <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>g</mml:mi><mml:mtext>A</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> and <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>g</mml:mi><mml:mtext>C</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula></title>
      <p>Due to the lack of direct canopy-scale <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>g</mml:mi><mml:mtext>A</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> measurements, a rigorous
evaluation of <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>g</mml:mi><mml:mtext>A</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> cannot be performed. To evaluate the STIC
retrievals of <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>g</mml:mi><mml:mtext>A</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> (<inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>g</mml:mi><mml:mtext>A-STIC</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula>), we adopted three different
methods.
<list list-type="custom"><list-item><label>a.</label>
      <p>By using the measured friction velocity (<inline-formula><mml:math display="inline"><mml:mrow><mml:msup><mml:mi>u</mml:mi><mml:mo>*</mml:mo></mml:msup></mml:mrow></mml:math></inline-formula>) and wind speed (<inline-formula><mml:math display="inline"><mml:mi>u</mml:mi></mml:math></inline-formula>)
at the EC towers and using the equation of Baldocchi and Ma (2013)
(<inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>g</mml:mi><mml:mtext>A-BM13</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula>) in which <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>g</mml:mi><mml:mtext>A</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> was expressed as the sum of
turbulent conductance and canopy (quasi-laminar) boundary-layer conductance
as<disp-formula id="Ch1.E7" content-type="numbered"><mml:math display="block"><mml:mrow><mml:msub><mml:mi>g</mml:mi><mml:mtext>A-BM13</mml:mtext></mml:msub><mml:mo>=</mml:mo><mml:msup><mml:mfenced close="]" open="["><mml:mfenced close=")" open="("><mml:mi>u</mml:mi><mml:mo>/</mml:mo><mml:msup><mml:mi>u</mml:mi><mml:mrow><mml:msup><mml:mo>*</mml:mo><mml:mn mathvariant="normal">2</mml:mn></mml:msup></mml:mrow></mml:msup></mml:mfenced><mml:mo>+</mml:mo><mml:mfenced open="(" close=")"><mml:mn mathvariant="normal">2</mml:mn><mml:mo>/</mml:mo><mml:mi>k</mml:mi><mml:msup><mml:mi>u</mml:mi><mml:mrow><mml:msup><mml:mo>*</mml:mo><mml:mn mathvariant="normal">2</mml:mn></mml:msup></mml:mrow></mml:msup></mml:mfenced><mml:mo>(</mml:mo><mml:mtext mathvariant="italic">Sc</mml:mtext><mml:mo>/</mml:mo><mml:mtext mathvariant="italic">Pr</mml:mtext><mml:msup><mml:mo>)</mml:mo><mml:mn>0.67</mml:mn></mml:msup></mml:mfenced><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:msup><mml:mo>,</mml:mo></mml:mrow></mml:math></disp-formula>where <inline-formula><mml:math display="inline"><mml:mi mathvariant="italic">κ</mml:mi></mml:math></inline-formula> is the von Kármán constant, 0.4; <italic>Sc</italic> is the
Schmidt number; <italic>Pr</italic> is the Prandtl number, and their ratio is
generally considered to be unity. Here the conductances of momentum,
sensible, and latent heat fluxes are assumed to be identical (Raupach, 1998).</p></list-item><list-item><label>b.</label>
      <p>By inverting <inline-formula><mml:math display="inline"><mml:mrow><mml:mi mathvariant="italic">λ</mml:mi><mml:mi>E</mml:mi></mml:mrow></mml:math></inline-formula> observations for wet conditions, hence assuming
<inline-formula><mml:math display="inline"><mml:mrow><mml:mi mathvariant="italic">λ</mml:mi><mml:mi>E</mml:mi></mml:mrow></mml:math></inline-formula> <inline-formula><mml:math display="inline"><mml:mo>≅</mml:mo></mml:math></inline-formula> <inline-formula><mml:math display="inline"><mml:mrow><mml:mi mathvariant="italic">λ</mml:mi><mml:msup><mml:mi>E</mml:mi><mml:mo>*</mml:mo></mml:msup></mml:mrow></mml:math></inline-formula> and estimating <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>g</mml:mi><mml:mtext>A</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula>
(<inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>g</mml:mi><mml:mtext>A-INV</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula>) as<disp-formula id="Ch1.E8" content-type="numbered"><mml:math display="block"><mml:mrow><mml:msub><mml:mi>g</mml:mi><mml:mtext>A-INV</mml:mtext></mml:msub><mml:mo>=</mml:mo><mml:mi mathvariant="italic">γ</mml:mi><mml:mi mathvariant="italic">λ</mml:mi><mml:mi>E</mml:mi><mml:mo>/</mml:mo><mml:mi mathvariant="italic">ρ</mml:mi><mml:msub><mml:mi>c</mml:mi><mml:mi>P</mml:mi></mml:msub><mml:msub><mml:mi>D</mml:mi><mml:mtext>A</mml:mtext></mml:msub><mml:mo>.</mml:mo></mml:mrow></mml:math></disp-formula></p></list-item><list-item><label>c.</label>
      <p>By inverting the aerodynamic equation of <inline-formula><mml:math display="inline"><mml:mi>H</mml:mi></mml:math></inline-formula> and estimating a hybrid
<inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>g</mml:mi><mml:mtext>A</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> (<inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>g</mml:mi><mml:mtext>A-HYB</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula>) from observed <inline-formula><mml:math display="inline"><mml:mi>H</mml:mi></mml:math></inline-formula> and STIC <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>T</mml:mi><mml:mn mathvariant="normal">0</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> as (<inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>T</mml:mi><mml:mtext>0-STIC</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula>),<disp-formula id="Ch1.E9" content-type="numbered"><mml:math display="block"><mml:mrow><mml:msub><mml:mi>g</mml:mi><mml:mtext>A-HYB</mml:mtext></mml:msub><mml:mo>=</mml:mo><mml:mi>H</mml:mi><mml:mo>/</mml:mo><mml:mi mathvariant="italic">ρ</mml:mi><mml:msub><mml:mi>c</mml:mi><mml:mi>P</mml:mi></mml:msub><mml:mfenced close=")" open="("><mml:msub><mml:mi>T</mml:mi><mml:mtext>0-STIC</mml:mtext></mml:msub><mml:mo>-</mml:mo><mml:msub><mml:mi>T</mml:mi><mml:mtext>A</mml:mtext></mml:msub></mml:mfenced><mml:mo>.</mml:mo></mml:mrow></mml:math></disp-formula>Like <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>g</mml:mi><mml:mtext>A-STIC</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula>, direct verification of STIC <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>g</mml:mi><mml:mtext>C</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula>
(<inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>g</mml:mi><mml:mtext>C-STIC</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula>) could not be performed, as canopy-scale <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>g</mml:mi><mml:mtext>C</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula>
observations are not possible with current measurement techniques. Although
leaf-scale <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>g</mml:mi><mml:mtext>C</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> measurements are relatively straightforward, these
values are not comparable to values retrieved at the canopy scale. However,
assuming <inline-formula><mml:math display="inline"><mml:mrow><mml:msup><mml:mi>u</mml:mi><mml:mo>*</mml:mo></mml:msup></mml:mrow></mml:math></inline-formula>-based <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>g</mml:mi><mml:mtext>A</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> as the baseline aerodynamic conductance,
we have estimated canopy-scale <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>g</mml:mi><mml:mtext>C</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> by inverting the PM equation
(<inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>g</mml:mi><mml:mtext>C-INV</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula>) (Monteith, 1995) to evaluate <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>g</mml:mi><mml:mtext>C-STIC</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> by
exploiting <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>g</mml:mi><mml:mtext>A-BM13</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> in conjunction with the available <inline-formula><mml:math display="inline"><mml:mi mathvariant="italic">ϕ</mml:mi></mml:math></inline-formula>,
<inline-formula><mml:math display="inline"><mml:mrow><mml:mi mathvariant="italic">λ</mml:mi><mml:mi>E</mml:mi></mml:mrow></mml:math></inline-formula>, <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>T</mml:mi><mml:mtext>A</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula>, and <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>D</mml:mi><mml:mtext>A</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> measurements from the EC towers.</p></list-item></list></p>
</sec>
<sec id="Ch1.S2.SS5">
  <title>Decoupling coefficient and biophysical controls</title>
      <p>The decoupling coefficient or “Omega” (<inline-formula><mml:math display="inline"><mml:mi mathvariant="normal">Ω</mml:mi></mml:math></inline-formula>) is a dimensionless
coefficient ranging from 0.0 to 1.0 (Jarvis and McNaughton, 1986) and is
considered as an index of the degree of stomatal control on transpiration
relative to the environment. The equation of <inline-formula><mml:math display="inline"><mml:mi mathvariant="normal">Ω</mml:mi></mml:math></inline-formula> is as follows:

                <disp-formula id="Ch1.E10" content-type="numbered"><mml:math display="block"><mml:mrow><mml:mi mathvariant="normal">Ω</mml:mi><mml:mo>=</mml:mo><mml:mstyle displaystyle="true"><mml:mfrac style="display"><mml:mrow><mml:mstyle displaystyle="false"><mml:mfrac style="text"><mml:mi>s</mml:mi><mml:mi mathvariant="italic">γ</mml:mi></mml:mfrac></mml:mstyle><mml:mo>+</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow><mml:mrow><mml:mstyle displaystyle="false"><mml:mfrac style="text"><mml:mi>s</mml:mi><mml:mi mathvariant="italic">γ</mml:mi></mml:mfrac></mml:mstyle><mml:mo>+</mml:mo><mml:mn mathvariant="normal">1</mml:mn><mml:mo>+</mml:mo><mml:mstyle displaystyle="false"><mml:mfrac style="text"><mml:mrow><mml:msub><mml:mi>g</mml:mi><mml:mtext>A</mml:mtext></mml:msub></mml:mrow><mml:mrow><mml:msub><mml:mi>g</mml:mi><mml:mtext>C</mml:mtext></mml:msub></mml:mrow></mml:mfrac></mml:mstyle></mml:mrow></mml:mfrac></mml:mstyle><mml:mo>.</mml:mo></mml:mrow></mml:math></disp-formula>

          Introducing <inline-formula><mml:math display="inline"><mml:mi mathvariant="normal">Ω</mml:mi></mml:math></inline-formula> into the Penman–Monteith (PM) equation for <inline-formula><mml:math display="inline"><mml:mrow><mml:mi mathvariant="italic">λ</mml:mi><mml:mi>E</mml:mi></mml:mrow></mml:math></inline-formula>
results in

                <disp-formula specific-use="align" content-type="numbered"><mml:math display="block"><mml:mtable displaystyle="true"><mml:mlabeledtr id="Ch1.E11"><mml:mtd/><mml:mtd/><mml:mtd><mml:mrow><mml:mi mathvariant="italic">λ</mml:mi><mml:mi>E</mml:mi><mml:mo>=</mml:mo><mml:mi mathvariant="normal">Ω</mml:mi><mml:mi mathvariant="italic">λ</mml:mi><mml:msub><mml:mi>E</mml:mi><mml:mtext>eq</mml:mtext></mml:msub><mml:mo>+</mml:mo><mml:mo>(</mml:mo><mml:mn mathvariant="normal">1</mml:mn><mml:mo>-</mml:mo><mml:mi mathvariant="normal">Ω</mml:mi><mml:mo>)</mml:mo><mml:mi mathvariant="italic">λ</mml:mi><mml:msub><mml:mi>E</mml:mi><mml:mtext>imp</mml:mtext></mml:msub><mml:mo>,</mml:mo></mml:mrow></mml:mtd></mml:mlabeledtr><mml:mlabeledtr id="Ch1.E12"><mml:mtd/><mml:mtd/><mml:mtd><mml:mrow><mml:mi mathvariant="italic">λ</mml:mi><mml:msub><mml:mi>E</mml:mi><mml:mtext>eq</mml:mtext></mml:msub><mml:mo>=</mml:mo><mml:mstyle displaystyle="true"><mml:mfrac style="display"><mml:mrow><mml:mi>s</mml:mi><mml:mi mathvariant="italic">ϕ</mml:mi></mml:mrow><mml:mrow><mml:mi>s</mml:mi><mml:mo>+</mml:mo><mml:mi mathvariant="italic">γ</mml:mi></mml:mrow></mml:mfrac></mml:mstyle><mml:mo>,</mml:mo></mml:mrow></mml:mtd></mml:mlabeledtr><mml:mlabeledtr id="Ch1.E13"><mml:mtd/><mml:mtd/><mml:mtd><mml:mrow><mml:mi mathvariant="italic">λ</mml:mi><mml:msub><mml:mi>E</mml:mi><mml:mtext>imp</mml:mtext></mml:msub><mml:mo>=</mml:mo><mml:mstyle displaystyle="true"><mml:mfrac style="display"><mml:mrow><mml:mi mathvariant="italic">ρ</mml:mi><mml:msub><mml:mi>c</mml:mi><mml:mi>P</mml:mi></mml:msub></mml:mrow><mml:mi mathvariant="italic">γ</mml:mi></mml:mfrac></mml:mstyle><mml:msub><mml:mi>g</mml:mi><mml:mtext>C</mml:mtext></mml:msub><mml:msub><mml:mi>D</mml:mi><mml:mtext>A</mml:mtext></mml:msub><mml:mo>,</mml:mo></mml:mrow></mml:mtd></mml:mlabeledtr></mml:mtable></mml:math></disp-formula>

            where <inline-formula><mml:math display="inline"><mml:mrow><mml:mi mathvariant="italic">λ</mml:mi><mml:msub><mml:mi>E</mml:mi><mml:mtext>eq</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> is the equilibrium latent heat flux, which
depends only on <inline-formula><mml:math display="inline"><mml:mi mathvariant="italic">ϕ</mml:mi></mml:math></inline-formula> and would be obtained over an extensive surface of
uniform moisture availability (Jarvis and McNaughton, 1986; Kumagai et al.,
2004). <inline-formula><mml:math display="inline"><mml:mrow><mml:mi mathvariant="italic">λ</mml:mi><mml:msub><mml:mi>E</mml:mi><mml:mtext>imp</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> is the imposed latent heat flux, which is
“imposed” by the atmosphere on the vegetation surface through the effects
of vapor pressure deficit (triggered under limited soil moisture
availability), and <inline-formula><mml:math display="inline"><mml:mrow><mml:mi mathvariant="italic">λ</mml:mi><mml:mi>E</mml:mi></mml:mrow></mml:math></inline-formula> becomes proportional to <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>g</mml:mi><mml:mtext>C</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula>.</p>
      <p>When the <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>g</mml:mi><mml:mtext>C</mml:mtext></mml:msub><mml:mo>/</mml:mo><mml:msub><mml:mi>g</mml:mi><mml:mtext>A</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> ratio is very small (i.e., water-stress
conditions), stomata principally control the water loss, and a change in
<inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>g</mml:mi><mml:mtext>C</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> will result in a nearly proportional change in transpiration.
Such conditions trigger a strong biophysical control on transpiration. In
this case the <inline-formula><mml:math display="inline"><mml:mi mathvariant="normal">Ω</mml:mi></mml:math></inline-formula> value approaches zero and vegetation is believed to be
fully coupled to the atmosphere. In contrast, for a high
<inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>g</mml:mi><mml:mtext>C</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> / <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>g</mml:mi><mml:mtext>A</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> ratio (i.e., high water availability), changes
in <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>g</mml:mi><mml:mtext>C</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> will have little effect on the transpiration rate, and
transpiration is predominantly controlled by <inline-formula><mml:math display="inline"><mml:mi mathvariant="italic">ϕ</mml:mi></mml:math></inline-formula>. In this case the
<inline-formula><mml:math display="inline"><mml:mi mathvariant="normal">Ω</mml:mi></mml:math></inline-formula> value approaches unity, and vegetation is considered to be poorly
coupled to the atmosphere.</p>
      <p>Given that both <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>g</mml:mi><mml:mtext>A</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> and <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>g</mml:mi><mml:mtext>C</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> are the independent estimates
in STIC1.2, the concept of <inline-formula><mml:math display="inline"><mml:mi mathvariant="normal">Ω</mml:mi></mml:math></inline-formula> was used to understand the degree of
biophysical control on <inline-formula><mml:math display="inline"><mml:mrow><mml:mi mathvariant="italic">λ</mml:mi><mml:msub><mml:mi>E</mml:mi><mml:mtext>T</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula>, which indicates the extent to
which the transpiration fluxes are approaching the equilibrium limit.
However, the biophysical characterization of <inline-formula><mml:math display="inline"><mml:mrow><mml:mi mathvariant="italic">λ</mml:mi><mml:msub><mml:mi>E</mml:mi><mml:mtext>T</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> and
<inline-formula><mml:math display="inline"><mml:mrow><mml:mi mathvariant="italic">λ</mml:mi><mml:msub><mml:mi>E</mml:mi><mml:mtext>E</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> through STIC1.2 significantly differs from previous
approaches (Ma et al., 2015; Chen et al., 2011; Kumagai et al., 2004), and
the fundamental differences are centered on the specifications of
<inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>g</mml:mi><mml:mtext>A</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> and <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>g</mml:mi><mml:mtext>C</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> (as described in Table A2). While the
estimation of <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>g</mml:mi><mml:mtext>A</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> in previous approaches was based on <inline-formula><mml:math display="inline"><mml:mi>u</mml:mi></mml:math></inline-formula> and
<inline-formula><mml:math display="inline"><mml:mrow><mml:msup><mml:mi>u</mml:mi><mml:mo>*</mml:mo></mml:msup></mml:mrow></mml:math></inline-formula>, the estimation of <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>g</mml:mi><mml:mtext>C</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> was based on inversion of observed
<inline-formula><mml:math display="inline"><mml:mrow><mml:mi mathvariant="italic">λ</mml:mi><mml:mi>E</mml:mi></mml:mrow></mml:math></inline-formula> based on the PM equation (e.g., Stella et al., 2013). However,
none of these approaches allow independent quantification of biophysical
controls of <inline-formula><mml:math display="inline"><mml:mrow><mml:mi mathvariant="italic">λ</mml:mi><mml:mi>E</mml:mi></mml:mrow></mml:math></inline-formula>, as <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>g</mml:mi><mml:mtext>C</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> is constrained by
<inline-formula><mml:math display="inline"><mml:mrow><mml:mi mathvariant="italic">λ</mml:mi><mml:mi>E</mml:mi></mml:mrow></mml:math></inline-formula> itself.</p>
</sec>
</sec>
<sec id="Ch1.S3">
  <title>Datasets</title>
<sec id="Ch1.S3.SSx1" specific-use="unnumbered">
  <title>Eddy covariance and meteorological quantities</title>
      <p>We used the LBA (Large-Scale Biosphere-Atmosphere Experiment in Amazonia)
data for quantifying the biophysical controls on the evaporative flux
components. LBA was an international research initiative conducted during
1995–2005 to study how Amazonia functions as a regional entity within the
larger Earth system, and how changes in land use and climate will affect the
hydrological and biogeochemical functioning of the Amazon ecosystem (Andreae
et al., 2002).</p>

<?xmltex \floatpos{t}?><table-wrap id="Ch1.T3" specific-use="star"><caption><p>Overview of the LBA tower sites. Here, (–) refers to (S) and (W) for
latitude and longitude, respectively.</p></caption><oasis:table frame="topbot"><oasis:tgroup cols="9">
     <oasis:colspec colnum="1" colname="col1" align="left"/>
     <oasis:colspec colnum="2" colname="col2" align="left"/>
     <oasis:colspec colnum="3" colname="col3" align="left"/>
     <oasis:colspec colnum="4" colname="col4" align="left"/>
     <oasis:colspec colnum="5" colname="col5" align="left"/>
     <oasis:colspec colnum="6" colname="col6" align="right"/>
     <oasis:colspec colnum="7" colname="col7" align="center"/>
     <oasis:colspec colnum="8" colname="col8" align="center"/>
     <oasis:colspec colnum="9" colname="col9" align="center"/>
     <oasis:thead>
       <oasis:row>  
         <oasis:entry colname="col1">Biome</oasis:entry>  
         <oasis:entry colname="col2">PFT</oasis:entry>  
         <oasis:entry colname="col3">Site</oasis:entry>  
         <oasis:entry colname="col4">LBA</oasis:entry>  
         <oasis:entry colname="col5">Data</oasis:entry>  
         <oasis:entry colname="col6">Latitude</oasis:entry>  
         <oasis:entry colname="col7">Longitude</oasis:entry>  
         <oasis:entry colname="col8">Tower</oasis:entry>  
         <oasis:entry colname="col9">Annual</oasis:entry>
       </oasis:row>
       <oasis:row>  
         <oasis:entry colname="col1"/>  
         <oasis:entry colname="col2"/>  
         <oasis:entry colname="col3"/>  
         <oasis:entry colname="col4">code</oasis:entry>  
         <oasis:entry colname="col5">availability</oasis:entry>  
         <oasis:entry colname="col6">(<inline-formula><mml:math display="inline"><mml:msup><mml:mi/><mml:mo>∘</mml:mo></mml:msup></mml:math></inline-formula>)</oasis:entry>  
         <oasis:entry colname="col7">(<inline-formula><mml:math display="inline"><mml:msup><mml:mi/><mml:mo>∘</mml:mo></mml:msup></mml:math></inline-formula>)</oasis:entry>  
         <oasis:entry colname="col8">height</oasis:entry>  
         <oasis:entry colname="col9">rainfall</oasis:entry>
       </oasis:row>
       <oasis:row rowsep="1">  
         <oasis:entry colname="col1"/>  
         <oasis:entry colname="col2"/>  
         <oasis:entry colname="col3"/>  
         <oasis:entry colname="col4"/>  
         <oasis:entry colname="col5">period</oasis:entry>  
         <oasis:entry colname="col6"/>  
         <oasis:entry colname="col7"/>  
         <oasis:entry colname="col8">(m)</oasis:entry>  
         <oasis:entry colname="col9">(mm)</oasis:entry>
       </oasis:row>
     </oasis:thead>
     <oasis:tbody>
       <oasis:row>  
         <oasis:entry colname="col1">Forest</oasis:entry>  
         <oasis:entry colname="col2">Tropical</oasis:entry>  
         <oasis:entry colname="col3">Manaus</oasis:entry>  
         <oasis:entry colname="col4">K34</oasis:entry>  
         <oasis:entry colname="col5">Jun 1999 to</oasis:entry>  
         <oasis:entry colname="col6"><inline-formula><mml:math display="inline"><mml:mo>-</mml:mo></mml:math></inline-formula>2.609</oasis:entry>  
         <oasis:entry colname="col7"><inline-formula><mml:math display="inline"><mml:mo>-</mml:mo></mml:math></inline-formula>60.209</oasis:entry>  
         <oasis:entry colname="col8">50</oasis:entry>  
         <oasis:entry colname="col9">2329</oasis:entry>
       </oasis:row>
       <oasis:row>  
         <oasis:entry colname="col1"/>  
         <oasis:entry colname="col2">rainforest</oasis:entry>  
         <oasis:entry colname="col3">KM34</oasis:entry>  
         <oasis:entry colname="col4"/>  
         <oasis:entry colname="col5">Sep 2006</oasis:entry>  
         <oasis:entry colname="col6"/>  
         <oasis:entry colname="col7"/>  
         <oasis:entry colname="col8"/>  
         <oasis:entry colname="col9"/>
       </oasis:row>
       <oasis:row rowsep="1">  
         <oasis:entry colname="col1"/>  
         <oasis:entry colname="col2">(TRF)</oasis:entry>  
         <oasis:entry colname="col3"/>  
         <oasis:entry colname="col4"/>  
         <oasis:entry colname="col5"/>  
         <oasis:entry colname="col6"/>  
         <oasis:entry colname="col7"/>  
         <oasis:entry colname="col8"/>  
         <oasis:entry colname="col9"/>
       </oasis:row>
       <oasis:row>  
         <oasis:entry colname="col1">Forest</oasis:entry>  
         <oasis:entry colname="col2">Tropical</oasis:entry>  
         <oasis:entry colname="col3">Santarem</oasis:entry>  
         <oasis:entry colname="col4">K67</oasis:entry>  
         <oasis:entry colname="col5">Jan 2002 to</oasis:entry>  
         <oasis:entry colname="col6"><inline-formula><mml:math display="inline"><mml:mo>-</mml:mo></mml:math></inline-formula>2.857</oasis:entry>  
         <oasis:entry colname="col7"><inline-formula><mml:math display="inline"><mml:mo>-</mml:mo></mml:math></inline-formula>54.959</oasis:entry>  
         <oasis:entry colname="col8">63</oasis:entry>  
         <oasis:entry colname="col9">1597</oasis:entry>
       </oasis:row>
       <oasis:row>  
         <oasis:entry colname="col1"/>  
         <oasis:entry colname="col2">moist</oasis:entry>  
         <oasis:entry colname="col3">KM67</oasis:entry>  
         <oasis:entry colname="col4"/>  
         <oasis:entry colname="col5">Jan 2006</oasis:entry>  
         <oasis:entry colname="col6"/>  
         <oasis:entry colname="col7"/>  
         <oasis:entry colname="col8"/>  
         <oasis:entry colname="col9"/>
       </oasis:row>
       <oasis:row>  
         <oasis:entry colname="col1"/>  
         <oasis:entry colname="col2">forest</oasis:entry>  
         <oasis:entry colname="col3"/>  
         <oasis:entry colname="col4"/>  
         <oasis:entry colname="col5"/>  
         <oasis:entry colname="col6"/>  
         <oasis:entry colname="col7"/>  
         <oasis:entry colname="col8"/>  
         <oasis:entry colname="col9"/>
       </oasis:row>
       <oasis:row rowsep="1">  
         <oasis:entry colname="col1"/>  
         <oasis:entry colname="col2">(TMF)</oasis:entry>  
         <oasis:entry colname="col3"/>  
         <oasis:entry colname="col4"/>  
         <oasis:entry colname="col5"/>  
         <oasis:entry colname="col6"/>  
         <oasis:entry colname="col7"/>  
         <oasis:entry colname="col8"/>  
         <oasis:entry colname="col9"/>
       </oasis:row>
       <oasis:row>  
         <oasis:entry colname="col1">Forest</oasis:entry>  
         <oasis:entry colname="col2">Tropical</oasis:entry>  
         <oasis:entry colname="col3">Santarem</oasis:entry>  
         <oasis:entry colname="col4">K83</oasis:entry>  
         <oasis:entry colname="col5">Jul 2000 to</oasis:entry>  
         <oasis:entry colname="col6"><inline-formula><mml:math display="inline"><mml:mo>-</mml:mo></mml:math></inline-formula>3.018</oasis:entry>  
         <oasis:entry colname="col7"><inline-formula><mml:math display="inline"><mml:mo>-</mml:mo></mml:math></inline-formula>54.971</oasis:entry>  
         <oasis:entry colname="col8">64</oasis:entry>  
         <oasis:entry colname="col9">1656</oasis:entry>
       </oasis:row>
       <oasis:row>  
         <oasis:entry colname="col1"/>  
         <oasis:entry colname="col2">moist</oasis:entry>  
         <oasis:entry colname="col3">KM83</oasis:entry>  
         <oasis:entry colname="col4"/>  
         <oasis:entry colname="col5">Dec 2004</oasis:entry>  
         <oasis:entry colname="col6"/>  
         <oasis:entry colname="col7"/>  
         <oasis:entry colname="col8"/>  
         <oasis:entry colname="col9"/>
       </oasis:row>
       <oasis:row>  
         <oasis:entry colname="col1"/>  
         <oasis:entry colname="col2">forest</oasis:entry>  
         <oasis:entry colname="col3"/>  
         <oasis:entry colname="col4"/>  
         <oasis:entry colname="col5"/>  
         <oasis:entry colname="col6"/>  
         <oasis:entry colname="col7"/>  
         <oasis:entry colname="col8"/>  
         <oasis:entry colname="col9"/>
       </oasis:row>
       <oasis:row rowsep="1">  
         <oasis:entry colname="col1"/>  
         <oasis:entry colname="col2">(TMF)</oasis:entry>  
         <oasis:entry colname="col3"/>  
         <oasis:entry colname="col4"/>  
         <oasis:entry colname="col5"/>  
         <oasis:entry colname="col6"/>  
         <oasis:entry colname="col7"/>  
         <oasis:entry colname="col8"/>  
         <oasis:entry colname="col9"/>
       </oasis:row>
       <oasis:row>  
         <oasis:entry colname="col1">Forest</oasis:entry>  
         <oasis:entry colname="col2">Tropical</oasis:entry>  
         <oasis:entry colname="col3">Reserva</oasis:entry>  
         <oasis:entry colname="col4">RJA</oasis:entry>  
         <oasis:entry colname="col5">Mar 1999 to</oasis:entry>  
         <oasis:entry colname="col6"><inline-formula><mml:math display="inline"><mml:mo>-</mml:mo></mml:math></inline-formula>10.083</oasis:entry>  
         <oasis:entry colname="col7"><inline-formula><mml:math display="inline"><mml:mo>-</mml:mo></mml:math></inline-formula>61.931</oasis:entry>  
         <oasis:entry colname="col8">60</oasis:entry>  
         <oasis:entry colname="col9">2354</oasis:entry>
       </oasis:row>
       <oasis:row>  
         <oasis:entry colname="col1"/>  
         <oasis:entry colname="col2">dry forest</oasis:entry>  
         <oasis:entry colname="col3">Biológica</oasis:entry>  
         <oasis:entry colname="col4"/>  
         <oasis:entry colname="col5">Oct 2002</oasis:entry>  
         <oasis:entry colname="col6"/>  
         <oasis:entry colname="col7"/>  
         <oasis:entry colname="col8"/>  
         <oasis:entry colname="col9"/>
       </oasis:row>
       <oasis:row rowsep="1">  
         <oasis:entry colname="col1"/>  
         <oasis:entry colname="col2">(TDF)</oasis:entry>  
         <oasis:entry colname="col3">Jarú</oasis:entry>  
         <oasis:entry colname="col4"/>  
         <oasis:entry colname="col5"/>  
         <oasis:entry colname="col6"/>  
         <oasis:entry colname="col7"/>  
         <oasis:entry colname="col8"/>  
         <oasis:entry colname="col9"/>
       </oasis:row>
       <oasis:row>  
         <oasis:entry colname="col1">Pasture</oasis:entry>  
         <oasis:entry colname="col2">Pasture</oasis:entry>  
         <oasis:entry colname="col3">Santarem</oasis:entry>  
         <oasis:entry colname="col4">K77</oasis:entry>  
         <oasis:entry colname="col5">Jan 2000 to</oasis:entry>  
         <oasis:entry colname="col6"><inline-formula><mml:math display="inline"><mml:mo>-</mml:mo></mml:math></inline-formula>3.012</oasis:entry>  
         <oasis:entry colname="col7"><inline-formula><mml:math display="inline"><mml:mo>-</mml:mo></mml:math></inline-formula>54.536</oasis:entry>  
         <oasis:entry colname="col8">18</oasis:entry>  
         <oasis:entry colname="col9">1597</oasis:entry>
       </oasis:row>
       <oasis:row rowsep="1">  
         <oasis:entry colname="col1"/>  
         <oasis:entry colname="col2">(PAS)</oasis:entry>  
         <oasis:entry colname="col3">KM77</oasis:entry>  
         <oasis:entry colname="col4"/>  
         <oasis:entry colname="col5">Dec 2001</oasis:entry>  
         <oasis:entry colname="col6"/>  
         <oasis:entry colname="col7"/>  
         <oasis:entry colname="col8"/>  
         <oasis:entry colname="col9"/>
       </oasis:row>
       <oasis:row>  
         <oasis:entry colname="col1">Pasture</oasis:entry>  
         <oasis:entry colname="col2">Pasture</oasis:entry>  
         <oasis:entry colname="col3">Fazenda</oasis:entry>  
         <oasis:entry colname="col4">FNS</oasis:entry>  
         <oasis:entry colname="col5">Mar 1999 to</oasis:entry>  
         <oasis:entry colname="col6"><inline-formula><mml:math display="inline"><mml:mo>-</mml:mo></mml:math></inline-formula>10.762</oasis:entry>  
         <oasis:entry colname="col7"><inline-formula><mml:math display="inline"><mml:mo>-</mml:mo></mml:math></inline-formula>62.357</oasis:entry>  
         <oasis:entry colname="col8">8.5</oasis:entry>  
         <oasis:entry colname="col9">1743</oasis:entry>
       </oasis:row>
       <oasis:row>  
         <oasis:entry colname="col1"/>  
         <oasis:entry colname="col2">(PAS)</oasis:entry>  
         <oasis:entry colname="col3">Nossa</oasis:entry>  
         <oasis:entry colname="col4"/>  
         <oasis:entry colname="col5">Oct 2002</oasis:entry>  
         <oasis:entry colname="col6"/>  
         <oasis:entry colname="col7"/>  
         <oasis:entry colname="col8"/>  
         <oasis:entry colname="col9"/>
       </oasis:row>
       <oasis:row>  
         <oasis:entry colname="col1"/>  
         <oasis:entry colname="col2"/>  
         <oasis:entry colname="col3">Senhora</oasis:entry>  
         <oasis:entry colname="col4"/>  
         <oasis:entry colname="col5"/>  
         <oasis:entry colname="col6"/>  
         <oasis:entry colname="col7"/>  
         <oasis:entry colname="col8"/>  
         <oasis:entry colname="col9"/>
       </oasis:row>
     </oasis:tbody>
   </oasis:tgroup></oasis:table></table-wrap>

      <?xmltex \floatpos{t}?><fig id="Ch1.F1" specific-use="star"><caption><p>Examples of monthly averages of the diurnal time series of canopy-scale
<bold>(a)</bold> <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>g</mml:mi><mml:mtext>A</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> and <bold>(b)</bold> <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>g</mml:mi><mml:mtext>C</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> estimated for two different biomes
(forest and pasture) in the Amazon Basin (LBA sites K34 and FNS). The time
series of four different <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>g</mml:mi><mml:mtext>A</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> estimates and their corresponding <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>g</mml:mi><mml:mtext>C</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula>
estimates are shown here.</p></caption>
          <?xmltex \igopts{width=341.433071pt}?><graphic xlink:href="https://hess.copernicus.org/articles/20/4237/2016/hess-20-4237-2016-f01.pdf"/>

        </fig>

      <p>A network of eddy covariance (EC) towers was operational during the LBA
experiment, such that data from nine EC towers were obtained from the ORNL
Distributed Archive Active Centre
(<uri>ftp://daac.ornl.gov/data/lba/carbon_dynamics/CD32_Brazil_Flux_Network/</uri>).
These are the quality-controlled and harmonized surface flux and
meteorological data from the Brazilian Amazon flux network. Time series of
surface fluxes (<inline-formula><mml:math display="inline"><mml:mrow><mml:mi mathvariant="italic">λ</mml:mi><mml:mi>E</mml:mi></mml:mrow></mml:math></inline-formula>, <inline-formula><mml:math display="inline"><mml:mi>H</mml:mi></mml:math></inline-formula>, <inline-formula><mml:math display="inline"><mml:mi>G</mml:mi></mml:math></inline-formula>), radiation (<inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>R</mml:mi><mml:mtext>N</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula>, shortwave
and longwave), thermal (<inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>T</mml:mi><mml:mtext>R</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula>), meteorological quantities
(<inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>T</mml:mi><mml:mtext>A</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula>, <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>R</mml:mi><mml:mtext>H</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula>, wind speed) as well as soil moisture and rainfall were
available from six (out of nine) EC towers. Three of the EC towers had
numerous missing data and were not included in the analysis. The surface
energy balance was closed by applying the Bowen ratio (Bowen, 1926) closure
as described in Chavez et al. (2005) and later adopted by Anderson et
al. (2007) and Mallick et al. (2015). In the absence of <inline-formula><mml:math display="inline"><mml:mi>G</mml:mi></mml:math></inline-formula> measurements,
<inline-formula><mml:math display="inline"><mml:mi mathvariant="italic">ϕ</mml:mi></mml:math></inline-formula> was assumed to be equal to the sum of <inline-formula><mml:math display="inline"><mml:mrow><mml:mi mathvariant="italic">λ</mml:mi><mml:mi>E</mml:mi></mml:mrow></mml:math></inline-formula> and <inline-formula><mml:math display="inline"><mml:mi>H</mml:mi></mml:math></inline-formula> with the
assumption that a dense vegetation canopy restricts the energy incident on
the soil surface, thereby allowing us to assume negligible ground heat flux.
For the present analysis, data from six selected EC towers (Table 2)
represent two different biomes (forest and pasture) covering four different
PFTs, namely, tropical rainforest (TRF), tropical moist forest (TMF),
tropical dry forest (TDF), and pasture (PAS), respectively. A general
description of the datasets can be found in Saleska et al. (2013). For all
sites, monthly averages of the diurnal cycle (hourly time resolution) were
chosen for the present analysis.</p>
</sec>
</sec>
<sec id="Ch1.S4">
  <title>Results</title>
<sec id="Ch1.S4.SS1">
  <?xmltex \opttitle{Evaluating $g_{\text{A}}$, $g_{\text{C}}$, and surface energy balance fluxes}?><title>Evaluating <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>g</mml:mi><mml:mtext>A</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula>, <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>g</mml:mi><mml:mtext>C</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula>, and surface energy balance fluxes</title>
      <p>Examples of monthly averages of the diurnal cycles of the four different
<inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>g</mml:mi><mml:mtext>A</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> estimates and their corresponding <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>g</mml:mi><mml:mtext>C</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> estimates over
two different PFTs (K34 for forest and FNS for pasture) reveal that
<inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>g</mml:mi><mml:mtext>A-STIC</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> and <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>g</mml:mi><mml:mtext>C-STIC</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> tend to be generally higher for the
forest than their counterparts, varying from 0 to 0.06 m s<inline-formula><mml:math display="inline"><mml:msup><mml:mi/><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:msup></mml:math></inline-formula> and 0 to
0.04 m s<inline-formula><mml:math display="inline"><mml:msup><mml:mi/><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:msup></mml:math></inline-formula> respectively (Fig. 1a and b). The magnitude of <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>g</mml:mi><mml:mtext>A-STIC</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> varied between 0 and 0.025 m s<inline-formula><mml:math display="inline"><mml:msup><mml:mi/><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:msup></mml:math></inline-formula> for the pasture
(Fig. 1a), while <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>g</mml:mi><mml:mtext>C-STIC</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> values were less than half of those
estimated over the forest (0–0.01 m s<inline-formula><mml:math display="inline"><mml:msup><mml:mi/><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:msup></mml:math></inline-formula>) (Fig. 1b). The conductances
showed a marked diurnal variation expressing their overall dependence on net
radiation, vapor pressure deficit, and surface temperature. Despite the
absolute differences between the conductances from the different retrieval
methods, their diurnal patterns were comparable.</p>
      <p>The canopy-scale evaluation of <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>g</mml:mi><mml:mtext>A-STIC</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> is illustrated in Fig. 2a
(and Table 3), combining data from the four PFTs. Estimated values range
between zero and 0.1 m s<inline-formula><mml:math display="inline"><mml:msup><mml:mi/><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:msup></mml:math></inline-formula> and show modest correlation
(<inline-formula><mml:math display="inline"><mml:mrow><mml:msup><mml:mi>R</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msup></mml:mrow></mml:math></inline-formula> <inline-formula><mml:math display="inline"><mml:mo>=</mml:mo></mml:math></inline-formula> 0.44) (<inline-formula><mml:math display="inline"><mml:mrow><mml:msup><mml:mi>R</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msup></mml:mrow></mml:math></inline-formula> range between 0.22 [<inline-formula><mml:math display="inline"><mml:mo>±</mml:mo></mml:math></inline-formula>0.18] and
0.55 [<inline-formula><mml:math display="inline"><mml:mo>±</mml:mo></mml:math></inline-formula>0.12]) between <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>g</mml:mi><mml:mtext>A-BM13</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> and <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>g</mml:mi><mml:mtext>A-STIC</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula>, with
regression parameters ranging from 0.81 (<inline-formula><mml:math display="inline"><mml:mo>±</mml:mo></mml:math></inline-formula>0.023) to 1.07 (<inline-formula><mml:math display="inline"><mml:mo>±</mml:mo></mml:math></inline-formula>0.047) for
the slope and 0.0019 (<inline-formula><mml:math display="inline"><mml:mo>±</mml:mo></mml:math></inline-formula>0.0006) to 0.0006 (<inline-formula><mml:math display="inline"><mml:mo>±</mml:mo></mml:math></inline-formula>0.0006) m s<inline-formula><mml:math display="inline"><mml:msup><mml:mi/><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:msup></mml:math></inline-formula> for
the offset (Table 3). The root mean squared deviation (RMSD) varied between
0.007 (TDF) and 0.013 m s<inline-formula><mml:math display="inline"><mml:msup><mml:mi/><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:msup></mml:math></inline-formula> (TRF). Statistical comparisons between
<inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>g</mml:mi><mml:mtext>A-STIC</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> and <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>g</mml:mi><mml:mtext>A-HYB</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> revealed relatively low RMSD and high
correlation between them (RMSD <inline-formula><mml:math display="inline"><mml:mo>=</mml:mo></mml:math></inline-formula> 0.007 m s<inline-formula><mml:math display="inline"><mml:msup><mml:mi/><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:msup></mml:math></inline-formula> and
<inline-formula><mml:math display="inline"><mml:mrow><mml:msup><mml:mi>R</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msup></mml:mrow></mml:math></inline-formula> <inline-formula><mml:math display="inline"><mml:mo>=</mml:mo></mml:math></inline-formula> 0.77) as compared to the error statistics between
<inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>g</mml:mi><mml:mtext>A-STIC</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> and <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>g</mml:mi><mml:mtext>A-INV</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> (RMSD <inline-formula><mml:math display="inline"><mml:mo>=</mml:mo></mml:math></inline-formula> 0.011 m s<inline-formula><mml:math display="inline"><mml:msup><mml:mi/><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:msup></mml:math></inline-formula> and
<inline-formula><mml:math display="inline"><mml:mrow><mml:msup><mml:mi>R</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msup></mml:mrow></mml:math></inline-formula> <inline-formula><mml:math display="inline"><mml:mo>=</mml:mo></mml:math></inline-formula> 0.50) (Fig. 2b and c). The residuals between <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>g</mml:mi><mml:mtext>A-STIC</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula>
and <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>g</mml:mi><mml:mtext>A-BM13</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> are plotted as a function of <inline-formula><mml:math display="inline"><mml:mi>u</mml:mi></mml:math></inline-formula> and <inline-formula><mml:math display="inline"><mml:mrow><mml:msup><mml:mi>u</mml:mi><mml:mo>*</mml:mo></mml:msup></mml:mrow></mml:math></inline-formula> in Fig. 2d
with the aim of ascertaining whether significant biases are introduced by
ignoring wind and shear information within STIC1.2. As illustrated in
Fig. 2d, there appears to be a weak systematic relationship between the
residual <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>g</mml:mi><mml:mtext>A</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> difference with either <inline-formula><mml:math display="inline"><mml:mrow><mml:msup><mml:mi>u</mml:mi><mml:mo>*</mml:mo></mml:msup></mml:mrow></mml:math></inline-formula> or <inline-formula><mml:math display="inline"><mml:mi>u</mml:mi></mml:math></inline-formula>
(<inline-formula><mml:math display="inline"><mml:mi>r</mml:mi></mml:math></inline-formula> <inline-formula><mml:math display="inline"><mml:mo>=</mml:mo></mml:math></inline-formula> <inline-formula><mml:math display="inline"><mml:mo>-</mml:mo></mml:math></inline-formula>0.26 and <inline-formula><mml:math display="inline"><mml:mo>-</mml:mo></mml:math></inline-formula>0.17). However, a considerable relationship was
found between wind- and shear-driven <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>g</mml:mi><mml:mtext>A</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> (i.e., <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>g</mml:mi><mml:mtext>A-BM13</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula>)
vs. <inline-formula><mml:math display="inline"><mml:mi mathvariant="italic">ϕ</mml:mi></mml:math></inline-formula>, <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>T</mml:mi><mml:mtext>R</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula>, and <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>D</mml:mi><mml:mtext>A</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> (<inline-formula><mml:math display="inline"><mml:mi>r</mml:mi></mml:math></inline-formula> <inline-formula><mml:math display="inline"><mml:mo>=</mml:mo></mml:math></inline-formula> 0.83, 0.48, and 0.42)
(Fig. 2e and f), which indicates that these three energy and water
constraints can explain 69, 23, and 17 % variance of <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>g</mml:mi><mml:mtext>A-BM13</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula>,
respectively.</p>
      <p>Canopy-scale evaluation of hourly <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>g</mml:mi><mml:mtext>C</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> is presented in Fig. 3a (and
Table 3), combining data from the four PFTs. Estimated values range between
zero and 0.06 m s<inline-formula><mml:math display="inline"><mml:msup><mml:mi/><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:msup></mml:math></inline-formula> for <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>g</mml:mi><mml:mtext>C-STIC</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> and show reasonable
correlation (<inline-formula><mml:math display="inline"><mml:mrow><mml:msup><mml:mi>R</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msup></mml:mrow></mml:math></inline-formula> <inline-formula><mml:math display="inline"><mml:mo>=</mml:mo></mml:math></inline-formula> 0.39) (<inline-formula><mml:math display="inline"><mml:mrow><mml:msup><mml:mi>R</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msup></mml:mrow></mml:math></inline-formula> range between 0.14 [<inline-formula><mml:math display="inline"><mml:mo>±</mml:mo></mml:math></inline-formula>0.04] and
0.58 [<inline-formula><mml:math display="inline"><mml:mo>±</mml:mo></mml:math></inline-formula>0.12]) between <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>g</mml:mi><mml:mtext>C-STIC</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> and <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>g</mml:mi><mml:mtext>C-INV</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula>, with
regression parameters ranging between 0.30 (<inline-formula><mml:math display="inline"><mml:mo>±</mml:mo></mml:math></inline-formula>0.022) and 0.85 (<inline-formula><mml:math display="inline"><mml:mo>±</mml:mo></mml:math></inline-formula>0.025)
for the slope and between 0.0024 (<inline-formula><mml:math display="inline"><mml:mo>±</mml:mo></mml:math></inline-formula>0.0003) and
0.0097 (<inline-formula><mml:math display="inline"><mml:mo>±</mml:mo></mml:math></inline-formula>0.0007) m s<inline-formula><mml:math display="inline"><mml:msup><mml:mi/><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:msup></mml:math></inline-formula> for the offset (Table 3). The RMSD varied
between 0.007 (PAS) and 0.012 m s<inline-formula><mml:math display="inline"><mml:msup><mml:mi/><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:msup></mml:math></inline-formula> (TRF and TDF). Given that
<inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>g</mml:mi><mml:mtext>A</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> significantly controls <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>g</mml:mi><mml:mtext>C</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula>, we also examined whether
biases in <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>g</mml:mi><mml:mtext>C</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> are introduced by ignoring wind and shear information
within STIC. The scatter plots between the residual <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>g</mml:mi><mml:mtext>C</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> difference
(<inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>g</mml:mi><mml:mtext>C-STIC</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> <inline-formula><mml:math display="inline"><mml:mo>-</mml:mo></mml:math></inline-formula> <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>g</mml:mi><mml:mtext>C-INV</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula>) vs. both <inline-formula><mml:math display="inline"><mml:mi>u</mml:mi></mml:math></inline-formula> and <inline-formula><mml:math display="inline"><mml:mrow><mml:msup><mml:mi>u</mml:mi><mml:mo>*</mml:mo></mml:msup></mml:mrow></mml:math></inline-formula> (Fig. 3b)
showed <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>g</mml:mi><mml:mtext>C</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> residuals to be evenly distributed across the entire
range of <inline-formula><mml:math display="inline"><mml:mi>u</mml:mi></mml:math></inline-formula> and <inline-formula><mml:math display="inline"><mml:mrow><mml:msup><mml:mi>u</mml:mi><mml:mo>*</mml:mo></mml:msup></mml:mrow></mml:math></inline-formula>, and no systematic pattern was evident.</p>

      <?xmltex \floatpos{t}?><fig id="Ch1.F2" specific-use="star"><caption><p><bold>(a)</bold> Comparison between STIC-derived <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>g</mml:mi><mml:mtext>A</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula>
(<inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>g</mml:mi><mml:mtext>A-STIC</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula>) with an estimated aerodynamic conductance based on
friction velocity (<inline-formula><mml:math display="inline"><mml:mrow><mml:msup><mml:mi>u</mml:mi><mml:mo>*</mml:mo></mml:msup></mml:mrow></mml:math></inline-formula>) and wind speed (<inline-formula><mml:math display="inline"><mml:mi>u</mml:mi></mml:math></inline-formula>) according to Baldocchi and
Ma (2013) (<inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>g</mml:mi><mml:mtext>A-BM13</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula>), <bold>(b)</bold> comparison between
<inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>g</mml:mi><mml:mtext>A-STIC</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> with an inverted <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>g</mml:mi><mml:mtext>A</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> (<inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>g</mml:mi><mml:mtext>A-INV</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula>) based on
EC observations of <inline-formula><mml:math display="inline"><mml:mrow><mml:mi mathvariant="italic">λ</mml:mi><mml:mi>E</mml:mi></mml:mrow></mml:math></inline-formula> and <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>D</mml:mi><mml:mtext>A</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula>, <bold>(c)</bold> comparison
between <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>g</mml:mi><mml:mtext>A-STIC</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> with a hybrid <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>g</mml:mi><mml:mtext>A</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> (<inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>g</mml:mi><mml:mtext>A-HYB</mml:mtext></mml:msub><mml:mo>)</mml:mo></mml:mrow></mml:math></inline-formula> based
on EC observations of <inline-formula><mml:math display="inline"><mml:mi>H</mml:mi></mml:math></inline-formula> and estimated <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>T</mml:mi><mml:mn mathvariant="normal">0</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> over the LBA EC sites,
<bold>(d)</bold> comparison between residual <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>g</mml:mi><mml:mtext>A</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> differences vs. <inline-formula><mml:math display="inline"><mml:mi>u</mml:mi></mml:math></inline-formula> and
<inline-formula><mml:math display="inline"><mml:mrow><mml:msup><mml:mi>u</mml:mi><mml:mo>*</mml:mo></mml:msup></mml:mrow></mml:math></inline-formula>, and <bold>(e, f)</bold> relationship between wind- and shear-derived
<inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>g</mml:mi><mml:mtext>A</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> vs. <inline-formula><mml:math display="inline"><mml:mi mathvariant="italic">ϕ</mml:mi></mml:math></inline-formula>, <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>T</mml:mi><mml:mtext>R</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula>, and <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>D</mml:mi><mml:mtext>A</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> over the LBA EC
sites.</p></caption>
          <?xmltex \igopts{width=341.433071pt}?><graphic xlink:href="https://hess.copernicus.org/articles/20/4237/2016/hess-20-4237-2016-f02.pdf"/>

        </fig>

      <?xmltex \floatpos{t}?><fig id="Ch1.F3" specific-use="star"><caption><p><bold>(a)</bold> Comparison between STIC-derived <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>g</mml:mi><mml:mtext>C</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula>
(<inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>g</mml:mi><mml:mtext>C-STIC</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula>) and <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>g</mml:mi><mml:mtext>C</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> computed by inverting the PM model (<inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>g</mml:mi><mml:mtext>C-INV</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula>) over the
LBA EC sites, where <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>g</mml:mi><mml:mtext>A-BM13</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> was used as aerodynamic input in
conjunction with tower measurements of <inline-formula><mml:math display="inline"><mml:mrow><mml:mi mathvariant="italic">λ</mml:mi><mml:mi>E</mml:mi></mml:mrow></mml:math></inline-formula>, radiation and
meteorological variables, and <bold>(b)</bold> residual <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>g</mml:mi><mml:mtext>C</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> differences
vs. wind speed (<inline-formula><mml:math display="inline"><mml:mi>u</mml:mi></mml:math></inline-formula>) and friction velocity (<inline-formula><mml:math display="inline"><mml:mrow><mml:msup><mml:mi>u</mml:mi><mml:mo>*</mml:mo></mml:msup></mml:mrow></mml:math></inline-formula>) over the LBA EC sites.</p></caption>
          <?xmltex \igopts{width=341.433071pt}?><graphic xlink:href="https://hess.copernicus.org/articles/20/4237/2016/hess-20-4237-2016-f03.pdf"/>

        </fig>

      <?xmltex \floatpos{t}?><fig id="Ch1.F4" specific-use="star"><caption><p>Comparison between STIC-derived <bold>(a)</bold> <inline-formula><mml:math display="inline"><mml:mrow><mml:mi mathvariant="italic">λ</mml:mi><mml:mi>E</mml:mi></mml:mrow></mml:math></inline-formula> and
<bold>(b)</bold> <inline-formula><mml:math display="inline"><mml:mi>H</mml:mi></mml:math></inline-formula> over four different PFTs in the Amazon Basin (LBA tower
sites). MAPD is the percent error defined as the mean absolute deviation
between the predicted and observed variables divided by the mean observed
variable.</p></caption>
          <?xmltex \igopts{width=341.433071pt}?><graphic xlink:href="https://hess.copernicus.org/articles/20/4237/2016/hess-20-4237-2016-f04.pdf"/>

        </fig>

      <p>The reliability of STIC1.2-based <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>g</mml:mi><mml:mtext>A</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> and <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>g</mml:mi><mml:mtext>C</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> retrievals was
further verified by evaluating <inline-formula><mml:math display="inline"><mml:mrow><mml:mi mathvariant="italic">λ</mml:mi><mml:mi>E</mml:mi></mml:mrow></mml:math></inline-formula> and <inline-formula><mml:math display="inline"><mml:mi>H</mml:mi></mml:math></inline-formula> estimates (Fig. 4). Both
the predicted <inline-formula><mml:math display="inline"><mml:mrow><mml:mi mathvariant="italic">λ</mml:mi><mml:mi>E</mml:mi></mml:mrow></mml:math></inline-formula> and <inline-formula><mml:math display="inline"><mml:mi>H</mml:mi></mml:math></inline-formula> are generally in good agreement with the
observations, with substantial correlation (<inline-formula><mml:math display="inline"><mml:mi>r</mml:mi></mml:math></inline-formula>) (<inline-formula><mml:math display="inline"><mml:mrow><mml:msup><mml:mi>R</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msup></mml:mrow></mml:math></inline-formula> from 0.61 to 0.94),
reasonable RMSD of 33 and 37 W m<inline-formula><mml:math display="inline"><mml:msup><mml:mi/><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">2</mml:mn></mml:mrow></mml:msup></mml:math></inline-formula>, and mean absolute percent
deviation (MAPD) of 14 and 32 % between the observed and STIC fluxes
(Fig. 4), respectively. Regression parameters varied between
0.96 (<inline-formula><mml:math display="inline"><mml:mo>±</mml:mo></mml:math></inline-formula>0.008) and 1.14 (<inline-formula><mml:math display="inline"><mml:mo>±</mml:mo></mml:math></inline-formula>0.010) for the slope and between
<inline-formula><mml:math display="inline"><mml:mo>-</mml:mo></mml:math></inline-formula>16 (<inline-formula><mml:math display="inline"><mml:mo>±</mml:mo></mml:math></inline-formula>2) and <inline-formula><mml:math display="inline"><mml:mo>-</mml:mo></mml:math></inline-formula>2 (<inline-formula><mml:math display="inline"><mml:mo>±</mml:mo></mml:math></inline-formula>2) W m<inline-formula><mml:math display="inline"><mml:msup><mml:mi/><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">2</mml:mn></mml:mrow></mml:msup></mml:math></inline-formula> for the offset for <inline-formula><mml:math display="inline"><mml:mrow><mml:mi mathvariant="italic">λ</mml:mi><mml:mi>E</mml:mi></mml:mrow></mml:math></inline-formula>
(Table 4), whereas for <inline-formula><mml:math display="inline"><mml:mi>H</mml:mi></mml:math></inline-formula>, these were 0.60 (<inline-formula><mml:math display="inline"><mml:mo>±</mml:mo></mml:math></inline-formula>0.025) to 0.89 (<inline-formula><mml:math display="inline"><mml:mo>±</mml:mo></mml:math></inline-formula>0.035)
for the slope and 9 (<inline-formula><mml:math display="inline"><mml:mo>±</mml:mo></mml:math></inline-formula>1) to 29 (<inline-formula><mml:math display="inline"><mml:mo>±</mml:mo></mml:math></inline-formula>2) W m<inline-formula><mml:math display="inline"><mml:msup><mml:mi/><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">2</mml:mn></mml:mrow></mml:msup></mml:math></inline-formula> for the offset
(Table 3), respectively. The RMSD in <inline-formula><mml:math display="inline"><mml:mrow><mml:mi mathvariant="italic">λ</mml:mi><mml:mi>E</mml:mi></mml:mrow></mml:math></inline-formula> varied from 20 to
31 W m<inline-formula><mml:math display="inline"><mml:msup><mml:mi/><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">2</mml:mn></mml:mrow></mml:msup></mml:math></inline-formula> and from 23 to 34 W m<inline-formula><mml:math display="inline"><mml:msup><mml:mi/><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">2</mml:mn></mml:mrow></mml:msup></mml:math></inline-formula> for <inline-formula><mml:math display="inline"><mml:mi>H</mml:mi></mml:math></inline-formula> (Table 3).</p>
      <p>The evaluation of the conductances and surface energy fluxes indicates some
efficacy for the STIC-derived fluxes and conductance estimates that represent
a weighted average of these variables over the source area around the EC
tower.</p>
</sec>
<sec id="Ch1.S4.SS2">
  <title>Canopy coupling, transpiration, and evaporation</title>
      <p>From Fig. 5a an overall weak to moderate relationship (<inline-formula><mml:math display="inline"><mml:mi>r</mml:mi></mml:math></inline-formula> <inline-formula><mml:math display="inline"><mml:mo>=</mml:mo></mml:math></inline-formula> <inline-formula><mml:math display="inline"><mml:mo>-</mml:mo></mml:math></inline-formula>0.31
to <inline-formula><mml:math display="inline"><mml:mo>-</mml:mo></mml:math></inline-formula>0.42) is apparent between the coupling (i.e., 1 <inline-formula><mml:math display="inline"><mml:mo>-</mml:mo></mml:math></inline-formula> <inline-formula><mml:math display="inline"><mml:mi mathvariant="normal">Ω</mml:mi></mml:math></inline-formula>) and
<inline-formula><mml:math display="inline"><mml:mrow><mml:mi mathvariant="italic">λ</mml:mi><mml:msub><mml:mi>E</mml:mi><mml:mtext>T</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula>, where <inline-formula><mml:math display="inline"><mml:mrow><mml:mi mathvariant="italic">λ</mml:mi><mml:msub><mml:mi>E</mml:mi><mml:mtext>T</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> is negatively related to
the coupling for all the PFTs, thus indicating the influence of weak to
moderate biophysical controls on <inline-formula><mml:math display="inline"><mml:mrow><mml:mi mathvariant="italic">λ</mml:mi><mml:msub><mml:mi>E</mml:mi><mml:mtext>T</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> throughout the year in
addition to radiative controls. The biophysical control was substantially
enhanced in TRF (<inline-formula><mml:math display="inline"><mml:mi>r</mml:mi></mml:math></inline-formula> increased from <inline-formula><mml:math display="inline"><mml:mo>-</mml:mo></mml:math></inline-formula>0.36 to <inline-formula><mml:math display="inline"><mml:mo>-</mml:mo></mml:math></inline-formula>0.53 and <inline-formula><mml:math display="inline"><mml:mo>-</mml:mo></mml:math></inline-formula>0.60) (47 to
67 % increase) and TMF (<inline-formula><mml:math display="inline"><mml:mi>r</mml:mi></mml:math></inline-formula> increased from <inline-formula><mml:math display="inline"><mml:mo>-</mml:mo></mml:math></inline-formula>0.31 to <inline-formula><mml:math display="inline"><mml:mo>-</mml:mo></mml:math></inline-formula>0.53 and <inline-formula><mml:math display="inline"><mml:mo>-</mml:mo></mml:math></inline-formula>0.58)
(70 to 85 % increase) during the dry seasons (July–September) (Fig. 5a). A
profound increase in the biophysical control on <inline-formula><mml:math display="inline"><mml:mrow><mml:mi mathvariant="italic">λ</mml:mi><mml:msub><mml:mi>E</mml:mi><mml:mtext>T</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> during
the dry season was also found in TDF (52 % increase) and PAS (37 %
increase) (Fig. 5a). The negative relationship (<inline-formula><mml:math display="inline"><mml:mi>r</mml:mi></mml:math></inline-formula> <inline-formula><mml:math display="inline"><mml:mo>=</mml:mo></mml:math></inline-formula> <inline-formula><mml:math display="inline"><mml:mo>-</mml:mo></mml:math></inline-formula>0.29 to <inline-formula><mml:math display="inline"><mml:mo>-</mml:mo></mml:math></inline-formula>0.45)
between (1 <inline-formula><mml:math display="inline"><mml:mo>-</mml:mo></mml:math></inline-formula> <inline-formula><mml:math display="inline"><mml:mi mathvariant="normal">Ω</mml:mi></mml:math></inline-formula>) and <inline-formula><mml:math display="inline"><mml:mrow><mml:mi mathvariant="italic">λ</mml:mi><mml:msub><mml:mi>E</mml:mi><mml:mtext>E</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> (Fig. 5b) in all four
PFTs indicated the role of aerodynamic control on <inline-formula><mml:math display="inline"><mml:mrow><mml:mi mathvariant="italic">λ</mml:mi><mml:msub><mml:mi>E</mml:mi><mml:mtext>E</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula>. The
aerodynamic control was also enhanced during the dry seasons, as shown by the
increased negative correlation (<inline-formula><mml:math display="inline"><mml:mi>r</mml:mi></mml:math></inline-formula> <inline-formula><mml:math display="inline"><mml:mo>=</mml:mo></mml:math></inline-formula> <inline-formula><mml:math display="inline"><mml:mo>-</mml:mo></mml:math></inline-formula>0.50 to <inline-formula><mml:math display="inline"><mml:mo>-</mml:mo></mml:math></inline-formula>0.69) (Fig. 5b)
between (1 <inline-formula><mml:math display="inline"><mml:mo>-</mml:mo></mml:math></inline-formula> <inline-formula><mml:math display="inline"><mml:mi mathvariant="normal">Ω</mml:mi></mml:math></inline-formula>) and <inline-formula><mml:math display="inline"><mml:mrow><mml:mi mathvariant="italic">λ</mml:mi><mml:msub><mml:mi>E</mml:mi><mml:mtext>E</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula>.</p>

      <?xmltex \floatpos{t}?><fig id="Ch1.F5" specific-use="star"><caption><p>Correlation of coupling (1 <inline-formula><mml:math display="inline"><mml:mo>-</mml:mo></mml:math></inline-formula> <inline-formula><mml:math display="inline"><mml:mi mathvariant="normal">Ω</mml:mi></mml:math></inline-formula>) with
<bold>(a)</bold> transpiration (<inline-formula><mml:math display="inline"><mml:mrow><mml:mi mathvariant="italic">λ</mml:mi><mml:msub><mml:mi>E</mml:mi><mml:mtext>T</mml:mtext></mml:msub><mml:mo>)</mml:mo></mml:mrow></mml:math></inline-formula> and
<bold>(b)</bold> evaporation (<inline-formula><mml:math display="inline"><mml:mrow><mml:mi mathvariant="italic">λ</mml:mi><mml:msub><mml:mi>E</mml:mi><mml:mtext>E</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula>) and over four different PFTs
by combining data for all the years, only during dry seasons for all the
years, and during drought year 2005. Data for 2005 were not available for TDF
and PAS. <bold>(c)</bold>–<bold>(e)</bold> Examples of the diurnal pattern of
<inline-formula><mml:math display="inline"><mml:mi mathvariant="normal">Ω</mml:mi></mml:math></inline-formula> (black lines), <inline-formula><mml:math display="inline"><mml:mrow><mml:mi mathvariant="italic">λ</mml:mi><mml:msub><mml:mi>E</mml:mi><mml:mtext>E</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> (grey dotted lines) and
<inline-formula><mml:math display="inline"><mml:mrow><mml:mi mathvariant="italic">λ</mml:mi><mml:msub><mml:mi>E</mml:mi><mml:mtext>T</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> (grey solid lines) estimated over two ecohydrologically
contrasting biomes (K34 for forest and FNS for pasture) in the Amazon Basin
(LBA tower sites) during wet and dry seasons.</p></caption>
          <?xmltex \igopts{width=341.433071pt}?><graphic xlink:href="https://hess.copernicus.org/articles/20/4237/2016/hess-20-4237-2016-f05.pdf"/>

        </fig>

      <p>Illustrative examples of the diurnal variations of <inline-formula><mml:math display="inline"><mml:mrow><mml:mi mathvariant="italic">λ</mml:mi><mml:msub><mml:mi>E</mml:mi><mml:mtext>E</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula>,
<inline-formula><mml:math display="inline"><mml:mrow><mml:mi mathvariant="italic">λ</mml:mi><mml:msub><mml:mi>E</mml:mi><mml:mtext>T</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula>, and <inline-formula><mml:math display="inline"><mml:mi mathvariant="normal">Ω</mml:mi></mml:math></inline-formula> for two different PFTs with different
annual rainfall (2329 mm in rainforest, K34, and 1597 mm in pasture, FNS)
for 3 consecutive days during both dry and wet seasons are shown in
Fig. 5c–f. This shows the morning rise of <inline-formula><mml:math display="inline"><mml:mi mathvariant="normal">Ω</mml:mi></mml:math></inline-formula> and a near-constant
afternoon <inline-formula><mml:math display="inline"><mml:mi mathvariant="normal">Ω</mml:mi></mml:math></inline-formula> in the wet season (Fig. 5c and 5d), thus indicating no
biophysical controls on <inline-formula><mml:math display="inline"><mml:mrow><mml:mi mathvariant="italic">λ</mml:mi><mml:msub><mml:mi>E</mml:mi><mml:mtext>E</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> and <inline-formula><mml:math display="inline"><mml:mrow><mml:mi mathvariant="italic">λ</mml:mi><mml:msub><mml:mi>E</mml:mi><mml:mtext>T</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula>
during this season. By contrast, during the dry season, the morning rise
in <inline-formula><mml:math display="inline"><mml:mi mathvariant="normal">Ω</mml:mi></mml:math></inline-formula> is followed by a decrease during noontime (15 to 25 % increase
in coupling in forest and pasture) (Fig. 5e and f) due to dominant
biophysical control, which is further accompanied by a transient increase
from mid-afternoon till late afternoon, and steadily declines thereafter.
Interestingly, coupling was relatively higher in pasture during the dry
seasons, and the reasons are detailed in the following section and
discussion.</p>
</sec>
<sec id="Ch1.S4.SS3">
  <?xmltex \opttitle{$g_{\text{C}}$ and $g_{\text{A}}$ vs.~transpiration and evaporation}?><title><inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>g</mml:mi><mml:mtext>C</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> and <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>g</mml:mi><mml:mtext>A</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> vs. transpiration and evaporation</title>
      <p>Scatter plots between <inline-formula><mml:math display="inline"><mml:mrow><mml:mi mathvariant="italic">λ</mml:mi><mml:msub><mml:mi>E</mml:mi><mml:mtext>T</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> and <inline-formula><mml:math display="inline"><mml:mrow><mml:mi mathvariant="italic">λ</mml:mi><mml:msub><mml:mi>E</mml:mi><mml:mtext>E</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula>
vs. <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>g</mml:mi><mml:mtext>C</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> and <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>g</mml:mi><mml:mtext>A</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> showed a triangular pattern that became
wider with increasing conductances (Fig. 6). To explain this behavior of
<inline-formula><mml:math display="inline"><mml:mrow><mml:mi mathvariant="italic">λ</mml:mi><mml:msub><mml:mi>E</mml:mi><mml:mtext>T</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> vs. <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>g</mml:mi><mml:mtext>C</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> and <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>g</mml:mi><mml:mtext>A</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula>, we further examined
the entire mechanism of conductance–<inline-formula><mml:math display="inline"><mml:mrow><mml:mi mathvariant="italic">λ</mml:mi><mml:msub><mml:mi>E</mml:mi><mml:mtext>T</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> interactions
through two-dimensional scatters between <inline-formula><mml:math display="inline"><mml:mrow><mml:mi mathvariant="italic">λ</mml:mi><mml:msub><mml:mi>E</mml:mi><mml:mtext>T</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> and
conductances for two consecutive diurnal cycles during wet and dry seasons
over rainforest and pasture sites with different annual rainfall (e.g., K34
as a wet site and FNS as a dry site, annual rainfall 2329 and 1597 mm)
(Fig. 7). Our results confirm the occurrence of diurnal hysteresis between
<inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>g</mml:mi><mml:mtext>C</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> <inline-formula><mml:math display="inline"><mml:mo>-</mml:mo></mml:math></inline-formula> <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>g</mml:mi><mml:mtext>A</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> and <inline-formula><mml:math display="inline"><mml:mrow><mml:mi mathvariant="italic">λ</mml:mi><mml:msub><mml:mi>E</mml:mi><mml:mtext>T</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> and explain the
reason for the shape of the curves obtained in Fig. 6. During the wet season,
a distinct environmental control is detectable on <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>g</mml:mi><mml:mtext>C</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> and
<inline-formula><mml:math display="inline"><mml:mrow><mml:mi mathvariant="italic">λ</mml:mi><mml:msub><mml:mi>E</mml:mi><mml:mtext>T</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> in the morning hours (Fig. 7a and b) in both the PFTs
where <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>g</mml:mi><mml:mtext>C</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> and <inline-formula><mml:math display="inline"><mml:mrow><mml:mi mathvariant="italic">λ</mml:mi><mml:msub><mml:mi>E</mml:mi><mml:mtext>T</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> increased as a result of
increasing <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>R</mml:mi><mml:mtext>N</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula>, <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>T</mml:mi><mml:mtext>R</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula>, and <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>D</mml:mi><mml:mtext>A</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula>. From the late
morning to afternoon, a near-constant (forest) or negligible (pasture)
increase in <inline-formula><mml:math display="inline"><mml:mrow><mml:mi mathvariant="italic">λ</mml:mi><mml:msub><mml:mi>E</mml:mi><mml:mtext>T</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> is observed despite substantial reduction
of both <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>g</mml:mi><mml:mtext>C</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> and <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>g</mml:mi><mml:mtext>A</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> (25 to 50 % decrease), after which
<inline-formula><mml:math display="inline"><mml:mrow><mml:mi mathvariant="italic">λ</mml:mi><mml:msub><mml:mi>E</mml:mi><mml:mtext>T</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> starts decreasing. This behavior of
<inline-formula><mml:math display="inline"><mml:mrow><mml:mi mathvariant="italic">λ</mml:mi><mml:msub><mml:mi>E</mml:mi><mml:mtext>T</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> was triggered due to the concurrent changes in
<inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>R</mml:mi><mml:mtext>N</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> (15 to 50 % change), <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>D</mml:mi><mml:mtext>A</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> (20 to 60 % change), and
<inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>T</mml:mi><mml:mtext>R</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> (5 to 14 % change), which indicates the absence of any
dominant biophysical regulation on <inline-formula><mml:math display="inline"><mml:mrow><mml:mi mathvariant="italic">λ</mml:mi><mml:msub><mml:mi>E</mml:mi><mml:mtext>T</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> during the wet
season (Fig. 7a and b). On the contrary, in the dry season, although the
morning rise in <inline-formula><mml:math display="inline"><mml:mrow><mml:mi mathvariant="italic">λ</mml:mi><mml:msub><mml:mi>E</mml:mi><mml:mtext>T</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> is steadily controlled by the
integrated influence of environmental variables, a modest to strong
biophysical control is found for both PFTs during the afternoon, where
<inline-formula><mml:math display="inline"><mml:mrow><mml:mi mathvariant="italic">λ</mml:mi><mml:msub><mml:mi>E</mml:mi><mml:mtext>T</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> substantially decreased with decreasing conductances
(Fig. 7c and d). This decrease in <inline-formula><mml:math display="inline"><mml:mrow><mml:mi mathvariant="italic">λ</mml:mi><mml:msub><mml:mi>E</mml:mi><mml:mtext>T</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> is mainly caused by
the reduction in <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>g</mml:mi><mml:mtext>C</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> as a result of increasing <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>D</mml:mi><mml:mtext>A</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> and
<inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>T</mml:mi><mml:mtext>R</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> (as seen later in Fig. 8a and c). In the dry season, the area
under the hysteretic relationship between <inline-formula><mml:math display="inline"><mml:mrow><mml:mi mathvariant="italic">λ</mml:mi><mml:msub><mml:mi>E</mml:mi><mml:mtext>T</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula>,
<inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>g</mml:mi><mml:mtext>C</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula>, and environmental variables was substantially wider in pasture
(Fig. 7d) than for the rainforest (Fig. 7c), which is attributed to a greater
hysteresis area between <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>R</mml:mi><mml:mtext>N</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> and <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>D</mml:mi><mml:mtext>A</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> in pasture as a result
of reduced water supply. The stronger hysteresis effects in pasture during
the dry season (Fig. 7d) ultimately led to the stronger relationship between
coupling and <inline-formula><mml:math display="inline"><mml:mrow><mml:mi mathvariant="italic">λ</mml:mi><mml:msub><mml:mi>E</mml:mi><mml:mtext>T</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> (as seen in Fig. 5a).</p>

      <?xmltex \floatpos{t}?><fig id="Ch1.F6" specific-use="star"><caption><p>Scatter plots of transpiration (<inline-formula><mml:math display="inline"><mml:mrow><mml:mi mathvariant="italic">λ</mml:mi><mml:msub><mml:mi>E</mml:mi><mml:mtext>T</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula>) and evaporation
(<inline-formula><mml:math display="inline"><mml:mrow><mml:mi mathvariant="italic">λ</mml:mi><mml:msub><mml:mi>E</mml:mi><mml:mtext>E</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula>) vs. <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>g</mml:mi><mml:mtext>C</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> and <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>g</mml:mi><mml:mtext>A</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> over four different
PFTs in the Amazon Basin (LBA tower sites).</p></caption>
          <?xmltex \igopts{width=341.433071pt}?><graphic xlink:href="https://hess.copernicus.org/articles/20/4237/2016/hess-20-4237-2016-f06.pdf"/>

        </fig>

      <?xmltex \floatpos{p}?><fig id="Ch1.F7" specific-use="star"><caption><p>Illustrative examples of the occurrence of diurnal hysteresis of
transpiration (<inline-formula><mml:math display="inline"><mml:mrow><mml:mi mathvariant="italic">λ</mml:mi><mml:msub><mml:mi>E</mml:mi><mml:mtext>T</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula>) during wet and dry seasons
with canopy and environmental controls over two different sites with
different annual rainfall (2329 and 1597 mm, respectively) in the Amazon
Basin (LBA tower sites K34 and FNS).</p></caption>
          <?xmltex \igopts{width=497.923228pt}?><graphic xlink:href="https://hess.copernicus.org/articles/20/4237/2016/hess-20-4237-2016-f07.pdf"/>

        </fig>

      <?xmltex \floatpos{t}?><fig id="Ch1.F8" specific-use="star"><caption><p><bold>(a)</bold> Response of retrieved <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>g</mml:mi><mml:mtext>C</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> to atmospheric vapor
pressure deficit (<inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>D</mml:mi><mml:mtext>A</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula>) for different classes of net
radiation (<inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>R</mml:mi><mml:mtext>N</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula>), <bold>(b)</bold> response of retrieved <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>g</mml:mi><mml:mtext>C</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> to
transpiration for different classes of <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>D</mml:mi><mml:mtext>A</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula>, <bold>(c)</bold> response of
retrieved <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>g</mml:mi><mml:mtext>C</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> to radiometric surface temperature (<inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>T</mml:mi><mml:mtext>R</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula>) for
different classes <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>D</mml:mi><mml:mtext>A</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula>, and <bold>(d)</bold> relationship between
retrieved <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>g</mml:mi><mml:mtext>A</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> and radiometric surface temperature and air
temperature difference (<inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>T</mml:mi><mml:mtext>R</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> <inline-formula><mml:math display="inline"><mml:mo>-</mml:mo></mml:math></inline-formula> <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>T</mml:mi><mml:mtext>A</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula>) in the Amazon Basin
(LBA tower sites).</p></caption>
          <?xmltex \igopts{width=341.433071pt}?><graphic xlink:href="https://hess.copernicus.org/articles/20/4237/2016/hess-20-4237-2016-f08.pdf"/>

        </fig>

</sec>
<sec id="Ch1.S4.SS4">
  <?xmltex \opttitle{Factors affecting variability of $g_{\text{C}}$ and $g_{\text{A}}$}?><title>Factors affecting variability of <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>g</mml:mi><mml:mtext>C</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> and <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>g</mml:mi><mml:mtext>A</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula></title>
      <p>The sensitivity of stomatal conductance to vapor pressure deficit is a key
governing factor of transpiration (Ocheltree et al., 2014; Monteith, 1995).
We examined whether the feedback or feed-forward response hypothesis
(Monteith, 1995; Farquhar, 1987) between <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>g</mml:mi><mml:mtext>C</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula>, <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>D</mml:mi><mml:mtext>A</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula>, and
<inline-formula><mml:math display="inline"><mml:mrow><mml:mi mathvariant="italic">λ</mml:mi><mml:msub><mml:mi>E</mml:mi><mml:mtext>T</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> is reflected in our canopy-scale <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>g</mml:mi><mml:mtext>C</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula>
retrievals. Combining data of all the PFTs, we found an exponential decline
of <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>g</mml:mi><mml:mtext>C</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> in response to increasing <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>D</mml:mi><mml:mtext>A</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> regardless of the
variations of net radiation (Fig. 8a). High <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>g</mml:mi><mml:mtext>C</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> is consistent with
high humidity and low evaporative demand. Five negatively logarithmic
scatters fit the data with <inline-formula><mml:math display="inline"><mml:mi>r</mml:mi></mml:math></inline-formula> values of 0.38
(0 <inline-formula><mml:math display="inline"><mml:mo>&lt;</mml:mo></mml:math></inline-formula> <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>R</mml:mi><mml:mtext>N</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> <inline-formula><mml:math display="inline"><mml:mo>&lt;</mml:mo></mml:math></inline-formula> 150 W m<inline-formula><mml:math display="inline"><mml:msup><mml:mi/><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">2</mml:mn></mml:mrow></mml:msup></mml:math></inline-formula>), 0.63
(150 <inline-formula><mml:math display="inline"><mml:mo>&lt;</mml:mo></mml:math></inline-formula> <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>R</mml:mi><mml:mtext>N</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> <inline-formula><mml:math display="inline"><mml:mo>&lt;</mml:mo></mml:math></inline-formula> 300 W m<inline-formula><mml:math display="inline"><mml:msup><mml:mi/><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">2</mml:mn></mml:mrow></mml:msup></mml:math></inline-formula>), 0.73
(300 <inline-formula><mml:math display="inline"><mml:mo>&lt;</mml:mo></mml:math></inline-formula> <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>R</mml:mi><mml:mtext>N</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> <inline-formula><mml:math display="inline"><mml:mo>&lt;</mml:mo></mml:math></inline-formula> 450 W m<inline-formula><mml:math display="inline"><mml:msup><mml:mi/><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">2</mml:mn></mml:mrow></mml:msup></mml:math></inline-formula>), 0.78
(450 <inline-formula><mml:math display="inline"><mml:mo>&lt;</mml:mo></mml:math></inline-formula> <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>R</mml:mi><mml:mtext>N</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> <inline-formula><mml:math display="inline"><mml:mo>&lt;</mml:mo></mml:math></inline-formula> 600 W m<inline-formula><mml:math display="inline"><mml:msup><mml:mi/><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">2</mml:mn></mml:mrow></mml:msup></mml:math></inline-formula>), and 0.87
(<inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>R</mml:mi><mml:mtext>N</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> <inline-formula><mml:math display="inline"><mml:mo>&gt;</mml:mo></mml:math></inline-formula> 600 W m<inline-formula><mml:math display="inline"><mml:msup><mml:mi/><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">2</mml:mn></mml:mrow></mml:msup></mml:math></inline-formula>). The sensitivity of <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>g</mml:mi><mml:mtext>C</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> to
<inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>D</mml:mi><mml:mtext>A</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> was at the maximum in the high <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>R</mml:mi><mml:mtext>N</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> range beyond
600 W m<inline-formula><mml:math display="inline"><mml:msup><mml:mi/><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">2</mml:mn></mml:mrow></mml:msup></mml:math></inline-formula> and the sensitivity progressively declined with declining
magnitude of <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>R</mml:mi><mml:mtext>N</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> (0–150 W m<inline-formula><mml:math display="inline"><mml:msup><mml:mi/><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">2</mml:mn></mml:mrow></mml:msup></mml:math></inline-formula>).</p>
      <p>Scatter plots between <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>g</mml:mi><mml:mtext>C</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> and <inline-formula><mml:math display="inline"><mml:mrow><mml:mi mathvariant="italic">λ</mml:mi><mml:msub><mml:mi>E</mml:mi><mml:mtext>T</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> for different
levels of <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>D</mml:mi><mml:mtext>A</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> revealed a linear pattern between them for a wide
range of <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>D</mml:mi><mml:mtext>A</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> (20 <inline-formula><mml:math display="inline"><mml:mo>&gt;</mml:mo></mml:math></inline-formula> <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>D</mml:mi><mml:mtext>A</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> <inline-formula><mml:math display="inline"><mml:mo>&gt;</mml:mo></mml:math></inline-formula> 0 hPa) (Fig. 8b).
Following Monteith (1995), isopleths of <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>R</mml:mi><mml:mtext>N</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> are delineated by the
solid lines passing through <inline-formula><mml:math display="inline"><mml:mrow><mml:mi mathvariant="italic">λ</mml:mi><mml:msub><mml:mi>E</mml:mi><mml:mtext>T</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> on the <inline-formula><mml:math display="inline"><mml:mi>x</mml:mi></mml:math></inline-formula> axis and through
<inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>g</mml:mi><mml:mtext>C</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> on the <inline-formula><mml:math display="inline"><mml:mi>y</mml:mi></mml:math></inline-formula> axis. Isobars of <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>D</mml:mi><mml:mtext>A</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> (dotted lines) pass
through the origin because <inline-formula><mml:math display="inline"><mml:mrow><mml:mi mathvariant="italic">λ</mml:mi><mml:msub><mml:mi>E</mml:mi><mml:mtext>T</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> approaches zero as
<inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>g</mml:mi><mml:mtext>C</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> approaches zero. Figure 8b shows substantial reduction of
<inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>g</mml:mi><mml:mtext>C</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> with increasing <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>D</mml:mi><mml:mtext>A</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> without any increase in
<inline-formula><mml:math display="inline"><mml:mrow><mml:mi mathvariant="italic">λ</mml:mi><mml:msub><mml:mi>E</mml:mi><mml:mtext>T</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula>, like an inverse hyperbolic pattern to <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>D</mml:mi><mml:mtext>A</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula>
(Monteith, 1995; Jones, 1998). For all the PFTs, an active biological (i.e.,
stomatal) regulation maintained almost constant <inline-formula><mml:math display="inline"><mml:mrow><mml:mi mathvariant="italic">λ</mml:mi><mml:msub><mml:mi>E</mml:mi><mml:mtext>T</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> when
<inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>D</mml:mi><mml:mtext>A</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> was changed from low to high values (Fig. 8b). At high
<inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>D</mml:mi><mml:mtext>A</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> (above 10 hPa), after an initial increase in
<inline-formula><mml:math display="inline"><mml:mrow><mml:mi mathvariant="italic">λ</mml:mi><mml:msub><mml:mi>E</mml:mi><mml:mtext>T</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> with <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>g</mml:mi><mml:mtext>C</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula>, <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>g</mml:mi><mml:mtext>C</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> approached a maximum
limit and remained nearly independent of <inline-formula><mml:math display="inline"><mml:mrow><mml:mi mathvariant="italic">λ</mml:mi><mml:msub><mml:mi>E</mml:mi><mml:mtext>T</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> (Fig. 8b).
Among all the <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>D</mml:mi><mml:mtext>A</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> levels, the maximum control of <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>g</mml:mi><mml:mtext>C</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> on
<inline-formula><mml:math display="inline"><mml:mrow><mml:mi mathvariant="italic">λ</mml:mi><mml:msub><mml:mi>E</mml:mi><mml:mtext>T</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> variability (62 to 80 %) was found at high
atmospheric water demand (i.e., 30 hPa <inline-formula><mml:math display="inline"><mml:mo>&gt;</mml:mo></mml:math></inline-formula> <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>D</mml:mi><mml:mtext>A</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> <inline-formula><mml:math display="inline"><mml:mo>&gt;</mml:mo></mml:math></inline-formula> 20 hPa).
The scatter plots between <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>g</mml:mi><mml:mtext>C</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> and <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>T</mml:mi><mml:mtext>R</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> (Fig. 8c) for
different levels of <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>D</mml:mi><mml:mtext>A</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> revealed an exponential decline in
<inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>g</mml:mi><mml:mtext>C</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> with increasing <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>T</mml:mi><mml:mtext>R</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> and atmospheric water demand. When
retrieved <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>g</mml:mi><mml:mtext>A</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> was plotted against the radiometric surface
temperature and air temperature difference (<inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>T</mml:mi><mml:mtext>R</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> <inline-formula><mml:math display="inline"><mml:mo>-</mml:mo></mml:math></inline-formula> <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>T</mml:mi><mml:mtext>A</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula>),
an exponential decline in <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>g</mml:mi><mml:mtext>A</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> was found in response to increasing
(<inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>T</mml:mi><mml:mtext>R</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> <inline-formula><mml:math display="inline"><mml:mo>-</mml:mo></mml:math></inline-formula> <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>T</mml:mi><mml:mtext>A</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula>) (Fig. 8d). High <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>g</mml:mi><mml:mtext>A</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> is persistent
with low (<inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>T</mml:mi><mml:mtext>R</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> <inline-formula><mml:math display="inline"><mml:mo>-</mml:mo></mml:math></inline-formula> <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>T</mml:mi><mml:mtext>A</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula>) irrespective of the variations in
<inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>R</mml:mi><mml:mtext>N</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> (with the exception of very low <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>R</mml:mi><mml:mtext>N</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula>). Four negatively
logarithmic scatters fit the <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>g</mml:mi><mml:mtext>A</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula>
vs. (<inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>T</mml:mi><mml:mtext>R</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> <inline-formula><mml:math display="inline"><mml:mo>-</mml:mo></mml:math></inline-formula> <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>T</mml:mi><mml:mtext>A</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula>) relationship with <inline-formula><mml:math display="inline"><mml:mi>r</mml:mi></mml:math></inline-formula> values of 0.28
(150 <inline-formula><mml:math display="inline"><mml:mo>&lt;</mml:mo></mml:math></inline-formula> <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>R</mml:mi><mml:mtext>N</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> <inline-formula><mml:math display="inline"><mml:mo>&lt;</mml:mo></mml:math></inline-formula> 300 W m<inline-formula><mml:math display="inline"><mml:msup><mml:mi/><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">2</mml:mn></mml:mrow></mml:msup></mml:math></inline-formula>), 0.55
(3000 <inline-formula><mml:math display="inline"><mml:mo>&lt;</mml:mo></mml:math></inline-formula> <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>R</mml:mi><mml:mtext>N</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> <inline-formula><mml:math display="inline"><mml:mo>&lt;</mml:mo></mml:math></inline-formula> 450 W m<inline-formula><mml:math display="inline"><mml:msup><mml:mi/><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">2</mml:mn></mml:mrow></mml:msup></mml:math></inline-formula>), 0.64
(450 <inline-formula><mml:math display="inline"><mml:mo>&lt;</mml:mo></mml:math></inline-formula> <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>R</mml:mi><mml:mtext>N</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> <inline-formula><mml:math display="inline"><mml:mo>&lt;</mml:mo></mml:math></inline-formula> 600 W m<inline-formula><mml:math display="inline"><mml:msup><mml:mi/><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">2</mml:mn></mml:mrow></mml:msup></mml:math></inline-formula>), and 0.77
(<inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>R</mml:mi><mml:mtext>N</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> <inline-formula><mml:math display="inline"><mml:mo>&gt;</mml:mo></mml:math></inline-formula> 600 W m<inline-formula><mml:math display="inline"><mml:msup><mml:mi/><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">2</mml:mn></mml:mrow></mml:msup></mml:math></inline-formula>).</p>

      <?xmltex \floatpos{t}?><fig id="Ch1.F9" specific-use="star"><caption><p><bold>(a)</bold> Scatter plots between source/sink height (or in-canopy)
vapor pressure deficit (<inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>D</mml:mi><mml:mn mathvariant="normal">0</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula>) and atmospheric vapor pressure
deficit (<inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>D</mml:mi><mml:mtext>A</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula>) for two different classes of
<inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>g</mml:mi><mml:mtext>C</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> / <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>g</mml:mi><mml:mtext>A</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> ratios over four PFTs, which clearly depicts a
strong coupling between <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>D</mml:mi><mml:mn mathvariant="normal">0</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> and <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>D</mml:mi><mml:mtext>A</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> for low
<inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>g</mml:mi><mml:mtext>C</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> / <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>g</mml:mi><mml:mtext>A</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> ratios. <bold>(b)</bold> Histogram distribution of
<inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>g</mml:mi><mml:mtext>C</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> / <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>g</mml:mi><mml:mtext>A</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> ratios over the four PFTs in the Amazon Basin
(LBA tower sites). <bold>(c)</bold> Scatter plots between
<inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>g</mml:mi><mml:mtext>C</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> / <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>g</mml:mi><mml:mtext>A</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> ratio vs. surface air temperature difference
(<inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>T</mml:mi><mml:mtext>R</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> <inline-formula><mml:math display="inline"><mml:mo>-</mml:mo></mml:math></inline-formula> <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>T</mml:mi><mml:mtext>A</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula>) for the four PFTs during the wet season and
dry season in the Amazon Basin (LBA tower sites).</p></caption>
          <?xmltex \igopts{width=497.923228pt}?><graphic xlink:href="https://hess.copernicus.org/articles/20/4237/2016/hess-20-4237-2016-f09.pdf"/>

        </fig>

</sec>
</sec>
<sec id="Ch1.S5">
  <title>Discussion</title>
<sec id="Ch1.S5.SS1">
  <?xmltex \opttitle{Evaluating $g_{\text{A}}$, $g_{\text{C}}$, and surface energy balance fluxes}?><title>Evaluating <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>g</mml:mi><mml:mtext>A</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula>, <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>g</mml:mi><mml:mtext>C</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula>, and surface energy balance fluxes</title>
      <p>The aerodynamic conductance retrieved with STIC1.2 showed acceptable
correlation and valid estimates of <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>g</mml:mi><mml:mtext>A</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> when compared against an
empirical model that uses <inline-formula><mml:math display="inline"><mml:mrow><mml:msup><mml:mi>u</mml:mi><mml:mo>*</mml:mo></mml:msup></mml:mrow></mml:math></inline-formula> and <inline-formula><mml:math display="inline"><mml:mi>u</mml:mi></mml:math></inline-formula> to derive <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>g</mml:mi><mml:mtext>A</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> (Figs. 1
and 2a) and two other inversion-/hybrid-based <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>g</mml:mi><mml:mtext>A</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> estimates. The
differences between <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>g</mml:mi><mml:mtext>A-STIC</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> and <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>g</mml:mi><mml:mtext>A-BM13</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> were mainly
attributed to the structural differences and empirical nature of the
parameterization for the near-surface boundary-layer conductance
((2/<inline-formula><mml:math display="inline"><mml:mrow><mml:mi>k</mml:mi><mml:msup><mml:mi>u</mml:mi><mml:mrow><mml:msup><mml:mo>*</mml:mo><mml:mn mathvariant="normal">2</mml:mn></mml:msup></mml:mrow></mml:msup></mml:mrow></mml:math></inline-formula>)(<italic>Sc</italic>/<italic>Pr</italic>)<inline-formula><mml:math display="inline"><mml:msup><mml:mi/><mml:mn>0.67</mml:mn></mml:msup></mml:math></inline-formula>) in <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>g</mml:mi><mml:mtext>A-BM13</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula>,
which results in some discrepancies between <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>g</mml:mi><mml:mtext>A-STIC</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> and
<inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>g</mml:mi><mml:mtext>A-BM13</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula>, particularly in the pasture (Fig. 2a). The extent to which
the structural discrepancies between <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>g</mml:mi><mml:mtext>A-STIC</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> and <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>g</mml:mi><mml:mtext>A-BM13</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula>
relate to actual differences in the conductances for momentum vs. heat is
beyond the scope of this paper, and a detailed investigation using data on
atmospheric profiles of wind speed, temperature, etc. are needed to actually
quantify such differences. Momentum transfer is associated with pressure
forces and is not identical to heat and mass transfer (Massman, 1999). In
STIC1.2, <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>g</mml:mi><mml:mtext>A</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> is directly estimated and is a robust representative of
the conductances to heat (and water vapor) transfer, whereas
<inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>g</mml:mi><mml:mtext>A-BM13</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> estimates based on <inline-formula><mml:math display="inline"><mml:mrow><mml:msup><mml:mi>u</mml:mi><mml:mo>*</mml:mo></mml:msup></mml:mrow></mml:math></inline-formula> and <inline-formula><mml:math display="inline"><mml:mi>u</mml:mi></mml:math></inline-formula> are more representative
of the momentum transfer. Therefore, the difference between the two different
<inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>g</mml:mi><mml:mtext>A</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> estimates (Fig. 2) can be largely attributed to the actual
difference in the conductances for momentum and heat (water vapor). The
turbulent conductance equation (<inline-formula><mml:math display="inline"><mml:mrow><mml:msup><mml:mi>u</mml:mi><mml:mrow><mml:msup><mml:mo>*</mml:mo><mml:mn mathvariant="normal">2</mml:mn></mml:msup></mml:mrow></mml:msup></mml:mrow></mml:math></inline-formula>/<inline-formula><mml:math display="inline"><mml:mi>u</mml:mi></mml:math></inline-formula>) in <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>g</mml:mi><mml:mtext>A-BM13</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> is
also very sensitive to the uncertainties in the sonic anemometer measurement
(Contini et al., 2006; Richiardone et al., 2012). However, the evidence of a
weak systematic relationship between the <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>g</mml:mi><mml:mtext>A</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> residuals and <inline-formula><mml:math display="inline"><mml:mi>u</mml:mi></mml:math></inline-formula>
(Fig. 2d) and the capability of the thermal (<inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>T</mml:mi><mml:mtext>R</mml:mtext></mml:msub><mml:mo>)</mml:mo></mml:mrow></mml:math></inline-formula>,
radiative (<inline-formula><mml:math display="inline"><mml:mi mathvariant="italic">ϕ</mml:mi></mml:math></inline-formula>), and meteorological (<inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>T</mml:mi><mml:mtext>A</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula>, <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>D</mml:mi><mml:mtext>A</mml:mtext></mml:msub><mml:mo>)</mml:mo></mml:mrow></mml:math></inline-formula> variables
in capturing the variability of <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>g</mml:mi><mml:mtext>A-BM13</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> (Fig. 2e and f) indicates
the diagnostic potential <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>g</mml:mi><mml:mtext>A-STIC</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> estimates to explain the
wind-driven <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>g</mml:mi><mml:mtext>A</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> variability. Excluding <inline-formula><mml:math display="inline"><mml:mi>u</mml:mi></mml:math></inline-formula> might introduce errors in
cases where wind is the only source of variations in <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>g</mml:mi><mml:mtext>A</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> and surface
fluxes (Mallick et al., 2015). In general, the accuracies in commonly used
parametric <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>g</mml:mi><mml:mtext>A</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> estimates based on <inline-formula><mml:math display="inline"><mml:mi>u</mml:mi></mml:math></inline-formula> and surface roughness
parameters several meters distant from canopy foliage are limited due to the
uncertainties concerning the attenuation of <inline-formula><mml:math display="inline"><mml:mi>u</mml:mi></mml:math></inline-formula> close to the vegetation
surface (Meinzer et al., 1997; Prihodko et al., 2008). The magnitude of <inline-formula><mml:math display="inline"><mml:mi>u</mml:mi></mml:math></inline-formula>
near the foliage can be substantially lower than that measured considerably
away at some reference location above or within the canopy (Meinzer et al.,
1997). Notwithstanding the inequalities of <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>g</mml:mi><mml:mtext>A</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> estimated with
different methods, it is challenging to infer the accuracy of the different
estimates. It is imperative to mention that <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>g</mml:mi><mml:mtext>A</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> is one of the main
anchors in the PM–SW model because it not only appears in the numerator and
denominator of these models, but also provides feedback to <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>g</mml:mi><mml:mtext>C</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula>,
<inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>T</mml:mi><mml:mn mathvariant="normal">0</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula>, and <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>D</mml:mi><mml:mn mathvariant="normal">0</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> (the seminal paper of Jarvis and McNaughton, 1986).
Therefore, the estimates of <inline-formula><mml:math display="inline"><mml:mrow><mml:mi mathvariant="italic">λ</mml:mi><mml:mi>E</mml:mi></mml:mrow></mml:math></inline-formula> in the PM–SW framework are very
sensitive to parameterization of <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>g</mml:mi><mml:mtext>A</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> and stable <inline-formula><mml:math display="inline"><mml:mrow><mml:mi mathvariant="italic">λ</mml:mi><mml:mi>E</mml:mi></mml:mrow></mml:math></inline-formula>
estimates might be possible if <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>g</mml:mi><mml:mtext>A</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> estimation is unambiguous
(Holwerda et al., 2012; Van Dijk et al., 2015). Given the lack of consensus
in the community on the “true” <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>g</mml:mi><mml:mtext>A</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> and from the nature of surface
flux validation results (Fig. 4), it appears that <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>g</mml:mi><mml:mtext>A-STIC</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> tends to
be the appropriate aerodynamic conductance that satisfies the PM–SW
equation. Discrepancies between <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>g</mml:mi><mml:mtext>C-STIC</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> and <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>g</mml:mi><mml:mtext>C-INV</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula>
originated from the differences in <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>g</mml:mi><mml:mtext>A</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> estimates between the two
methods.</p>

<?xmltex \floatpos{t}?><table-wrap id="Ch1.T4" specific-use="star"><caption><p>Comparative statistics for the STIC- and tower-derived hourly
<inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>g</mml:mi><mml:mtext>A</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> and <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>g</mml:mi><mml:mtext>C</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> for a range of PFTs in the Amazon Basin (LBA
tower sites). Values in parentheses are <inline-formula><mml:math display="inline"><mml:mo>±</mml:mo></mml:math></inline-formula>1 standard deviation (standard
error for correlation).</p></caption><oasis:table frame="topbot"><oasis:tgroup cols="11">
     <oasis:colspec colnum="1" colname="col1" align="left"/>
     <oasis:colspec colnum="2" colname="col2" align="center"/>
     <oasis:colspec colnum="3" colname="col3" align="center"/>
     <oasis:colspec colnum="4" colname="col4" align="center"/>
     <oasis:colspec colnum="5" colname="col5" align="center"/>
     <oasis:colspec colnum="6" colname="col6" align="left"/>
     <oasis:colspec colnum="7" colname="col7" align="center"/>
     <oasis:colspec colnum="8" colname="col8" align="center"/>
     <oasis:colspec colnum="9" colname="col9" align="center"/>
     <oasis:colspec colnum="10" colname="col10" align="center" colsep="1"/>
     <oasis:colspec colnum="11" colname="col11" align="center"/>
     <oasis:thead>
       <oasis:row>  
         <oasis:entry colname="col1"/>  
         <oasis:entry rowsep="1" namest="col2" nameend="col5"><inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>g</mml:mi><mml:mtext>A-STIC</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> vs. <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>g</mml:mi><mml:mtext>A-BM13</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula></oasis:entry>  
         <oasis:entry colname="col6"/>  
         <oasis:entry rowsep="1" namest="col7" nameend="col10" colsep="1"><inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>g</mml:mi><mml:mtext>C-STIC</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> vs. <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>g</mml:mi><mml:mtext>C-INV</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula></oasis:entry>  
         <oasis:entry colname="col11"/>
       </oasis:row>
       <oasis:row>  
         <oasis:entry colname="col1">PFTs</oasis:entry>  
         <oasis:entry colname="col2">RMSD</oasis:entry>  
         <oasis:entry colname="col3"><inline-formula><mml:math display="inline"><mml:mrow><mml:msup><mml:mi>R</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msup></mml:mrow></mml:math></inline-formula></oasis:entry>  
         <oasis:entry colname="col4">Slope</oasis:entry>  
         <oasis:entry colname="col5">Offset</oasis:entry>  
         <oasis:entry colname="col6"/>  
         <oasis:entry colname="col7">RMSD</oasis:entry>  
         <oasis:entry colname="col8"><inline-formula><mml:math display="inline"><mml:mrow><mml:msup><mml:mi>R</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msup></mml:mrow></mml:math></inline-formula></oasis:entry>  
         <oasis:entry colname="col9">Slope</oasis:entry>  
         <oasis:entry colname="col10">Offset</oasis:entry>  
         <oasis:entry colname="col11"><inline-formula><mml:math display="inline"><mml:mi>N</mml:mi></mml:math></inline-formula></oasis:entry>
       </oasis:row>
       <oasis:row rowsep="1">  
         <oasis:entry colname="col1"/>  
         <oasis:entry colname="col2">(m s<inline-formula><mml:math display="inline"><mml:msup><mml:mi/><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:msup></mml:math></inline-formula>)</oasis:entry>  
         <oasis:entry colname="col3"/>  
         <oasis:entry colname="col4"/>  
         <oasis:entry colname="col5">(m s<inline-formula><mml:math display="inline"><mml:msup><mml:mi/><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:msup></mml:math></inline-formula>)</oasis:entry>  
         <oasis:entry colname="col6"/>  
         <oasis:entry colname="col7">(m s<inline-formula><mml:math display="inline"><mml:msup><mml:mi/><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:msup></mml:math></inline-formula>)</oasis:entry>  
         <oasis:entry colname="col8"/>  
         <oasis:entry colname="col9"/>  
         <oasis:entry colname="col10">(m s<inline-formula><mml:math display="inline"><mml:msup><mml:mi/><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:msup></mml:math></inline-formula>)</oasis:entry>  
         <oasis:entry colname="col11"/>
       </oasis:row>
     </oasis:thead>
     <oasis:tbody>
       <oasis:row>  
         <oasis:entry colname="col1">TRF</oasis:entry>  
         <oasis:entry colname="col2">0.013</oasis:entry>  
         <oasis:entry colname="col3">0.41</oasis:entry>  
         <oasis:entry colname="col4">1.07</oasis:entry>  
         <oasis:entry colname="col5">0.0031</oasis:entry>  
         <oasis:entry colname="col6"/>  
         <oasis:entry colname="col7">0.012</oasis:entry>  
         <oasis:entry colname="col8">0.14</oasis:entry>  
         <oasis:entry colname="col9">0.39</oasis:entry>  
         <oasis:entry colname="col10">0.0097</oasis:entry>  
         <oasis:entry colname="col11">1159</oasis:entry>
       </oasis:row>
       <oasis:row rowsep="1">  
         <oasis:entry colname="col1"/>  
         <oasis:entry colname="col2"/>  
         <oasis:entry colname="col3">(<inline-formula><mml:math display="inline"><mml:mo>±</mml:mo></mml:math></inline-formula>0.03)</oasis:entry>  
         <oasis:entry colname="col4">(<inline-formula><mml:math display="inline"><mml:mo>±</mml:mo></mml:math></inline-formula>0.047)</oasis:entry>  
         <oasis:entry colname="col5">(<inline-formula><mml:math display="inline"><mml:mo>±</mml:mo></mml:math></inline-formula>0.0008)</oasis:entry>  
         <oasis:entry colname="col6"/>  
         <oasis:entry colname="col7"/>  
         <oasis:entry colname="col8">(<inline-formula><mml:math display="inline"><mml:mo>±</mml:mo></mml:math></inline-formula>0.04)</oasis:entry>  
         <oasis:entry colname="col9">(<inline-formula><mml:math display="inline"><mml:mo>±</mml:mo></mml:math></inline-formula>0.039)</oasis:entry>  
         <oasis:entry colname="col10">(<inline-formula><mml:math display="inline"><mml:mo>±</mml:mo></mml:math></inline-formula>0.0007)</oasis:entry>  
         <oasis:entry colname="col11"/>
       </oasis:row>
       <oasis:row>  
         <oasis:entry colname="col1">TMF</oasis:entry>  
         <oasis:entry colname="col2">0.012</oasis:entry>  
         <oasis:entry colname="col3">0.55</oasis:entry>  
         <oasis:entry colname="col4">0.81</oasis:entry>  
         <oasis:entry colname="col5">0.0006</oasis:entry>  
         <oasis:entry colname="col6"/>  
         <oasis:entry colname="col7">0.009</oasis:entry>  
         <oasis:entry colname="col8">0.55</oasis:entry>  
         <oasis:entry colname="col9">0.85</oasis:entry>  
         <oasis:entry colname="col10">0.0032</oasis:entry>  
         <oasis:entry colname="col11">1927</oasis:entry>
       </oasis:row>
       <oasis:row rowsep="1">  
         <oasis:entry colname="col1"/>  
         <oasis:entry colname="col2"/>  
         <oasis:entry colname="col3">(<inline-formula><mml:math display="inline"><mml:mo>±</mml:mo></mml:math></inline-formula>0.12)</oasis:entry>  
         <oasis:entry colname="col4">(<inline-formula><mml:math display="inline"><mml:mo>±</mml:mo></mml:math></inline-formula>0.023)</oasis:entry>  
         <oasis:entry colname="col5">(<inline-formula><mml:math display="inline"><mml:mo>±</mml:mo></mml:math></inline-formula>0.0006)</oasis:entry>  
         <oasis:entry colname="col6"/>  
         <oasis:entry colname="col7"/>  
         <oasis:entry colname="col8">(<inline-formula><mml:math display="inline"><mml:mo>±</mml:mo></mml:math></inline-formula>0.12)</oasis:entry>  
         <oasis:entry colname="col9">(<inline-formula><mml:math display="inline"><mml:mo>±</mml:mo></mml:math></inline-formula>0.025)</oasis:entry>  
         <oasis:entry colname="col10">(<inline-formula><mml:math display="inline"><mml:mo>±</mml:mo></mml:math></inline-formula>0.0005)</oasis:entry>  
         <oasis:entry colname="col11"/>
       </oasis:row>
       <oasis:row>  
         <oasis:entry colname="col1">TDF</oasis:entry>  
         <oasis:entry colname="col2">0.007</oasis:entry>  
         <oasis:entry colname="col3">0.49</oasis:entry>  
         <oasis:entry colname="col4">0.89</oasis:entry>  
         <oasis:entry colname="col5">0.0019</oasis:entry>  
         <oasis:entry colname="col6"/>  
         <oasis:entry colname="col7">0.012</oasis:entry>  
         <oasis:entry colname="col8">0.33</oasis:entry>  
         <oasis:entry colname="col9">0.30</oasis:entry>  
         <oasis:entry colname="col10">0.0050</oasis:entry>  
         <oasis:entry colname="col11">787</oasis:entry>
       </oasis:row>
       <oasis:row rowsep="1">  
         <oasis:entry colname="col1"/>  
         <oasis:entry colname="col2"/>  
         <oasis:entry colname="col3">(<inline-formula><mml:math display="inline"><mml:mo>±</mml:mo></mml:math></inline-formula>0.15)</oasis:entry>  
         <oasis:entry colname="col4">(<inline-formula><mml:math display="inline"><mml:mo>±</mml:mo></mml:math></inline-formula>0.041)</oasis:entry>  
         <oasis:entry colname="col5">(<inline-formula><mml:math display="inline"><mml:mo>±</mml:mo></mml:math></inline-formula>0.0006)</oasis:entry>  
         <oasis:entry colname="col6"/>  
         <oasis:entry colname="col7"/>  
         <oasis:entry colname="col8">(<inline-formula><mml:math display="inline"><mml:mo>±</mml:mo></mml:math></inline-formula>0.19)</oasis:entry>  
         <oasis:entry colname="col9">(<inline-formula><mml:math display="inline"><mml:mo>±</mml:mo></mml:math></inline-formula>0.022)</oasis:entry>  
         <oasis:entry colname="col10">(<inline-formula><mml:math display="inline"><mml:mo>±</mml:mo></mml:math></inline-formula>0.0005)</oasis:entry>  
         <oasis:entry colname="col11"/>
       </oasis:row>
       <oasis:row>  
         <oasis:entry colname="col1">PAS</oasis:entry>  
         <oasis:entry colname="col2">0.012</oasis:entry>  
         <oasis:entry colname="col3">0.22</oasis:entry>  
         <oasis:entry colname="col4">1.03</oasis:entry>  
         <oasis:entry colname="col5">0.0059</oasis:entry>  
         <oasis:entry colname="col6"/>  
         <oasis:entry colname="col7">0.007</oasis:entry>  
         <oasis:entry colname="col8">0.58</oasis:entry>  
         <oasis:entry colname="col9">0.65</oasis:entry>  
         <oasis:entry colname="col10">0.0024</oasis:entry>  
         <oasis:entry colname="col11">288</oasis:entry>
       </oasis:row>
       <oasis:row rowsep="1">  
         <oasis:entry colname="col1"/>  
         <oasis:entry colname="col2"/>  
         <oasis:entry colname="col3">(<inline-formula><mml:math display="inline"><mml:mo>±</mml:mo></mml:math></inline-formula>0.18)</oasis:entry>  
         <oasis:entry colname="col4">(<inline-formula><mml:math display="inline"><mml:mo>±</mml:mo></mml:math></inline-formula>0.083)</oasis:entry>  
         <oasis:entry colname="col5">(<inline-formula><mml:math display="inline"><mml:mo>±</mml:mo></mml:math></inline-formula>0.0007)</oasis:entry>  
         <oasis:entry colname="col6"/>  
         <oasis:entry colname="col7"/>  
         <oasis:entry colname="col8">(<inline-formula><mml:math display="inline"><mml:mo>±</mml:mo></mml:math></inline-formula>0.12)</oasis:entry>  
         <oasis:entry colname="col9">(<inline-formula><mml:math display="inline"><mml:mo>±</mml:mo></mml:math></inline-formula>0.025)</oasis:entry>  
         <oasis:entry colname="col10">(<inline-formula><mml:math display="inline"><mml:mo>±</mml:mo></mml:math></inline-formula>0.0003)</oasis:entry>  
         <oasis:entry colname="col11"/>
       </oasis:row>
       <oasis:row>  
         <oasis:entry colname="col1"><bold>Mean</bold></oasis:entry>  
         <oasis:entry colname="col2"><bold>0.012</bold></oasis:entry>  
         <oasis:entry colname="col3"><bold>0.44</bold></oasis:entry>  
         <oasis:entry colname="col4"><bold>0.76</bold></oasis:entry>  
         <oasis:entry colname="col5"><bold>0.0047</bold></oasis:entry>  
         <oasis:entry colname="col6"/>  
         <oasis:entry colname="col7"><bold>0.010</bold></oasis:entry>  
         <oasis:entry colname="col8"><bold>0.39</bold></oasis:entry>  
         <oasis:entry colname="col9"><bold>0.63</bold></oasis:entry>  
         <oasis:entry colname="col10"><bold>0.0046</bold></oasis:entry>  
         <oasis:entry colname="col11"><bold>4161</bold></oasis:entry>
       </oasis:row>
       <oasis:row>  
         <oasis:entry colname="col1"/>  
         <oasis:entry colname="col2"/>  
         <oasis:entry colname="col3">(<inline-formula><mml:math display="inline"><mml:mo mathvariant="bold">±</mml:mo></mml:math></inline-formula><bold>0.10</bold>)</oasis:entry>  
         <oasis:entry colname="col4">(<inline-formula><mml:math display="inline"><mml:mo mathvariant="bold">±</mml:mo></mml:math></inline-formula><bold>0.016</bold>)</oasis:entry>  
         <oasis:entry colname="col5">(<inline-formula><mml:math display="inline"><mml:mo mathvariant="bold">±</mml:mo></mml:math></inline-formula><bold>0.003</bold>)</oasis:entry>  
         <oasis:entry colname="col6"/>  
         <oasis:entry colname="col7"/>  
         <oasis:entry colname="col8">(<inline-formula><mml:math display="inline"><mml:mo mathvariant="bold">±</mml:mo></mml:math></inline-formula><bold>0.08</bold>)</oasis:entry>  
         <oasis:entry colname="col9">(<inline-formula><mml:math display="inline"><mml:mo mathvariant="bold">±</mml:mo></mml:math></inline-formula><bold>0.016</bold>)</oasis:entry>  
         <oasis:entry colname="col10">(<inline-formula><mml:math display="inline"><mml:mo mathvariant="bold">±</mml:mo></mml:math></inline-formula><bold>0.0003</bold>)</oasis:entry>  
         <oasis:entry colname="col11"/>
       </oasis:row>
     </oasis:tbody>
   </oasis:tgroup></oasis:table><table-wrap-foot><p><inline-formula><mml:math display="inline"><mml:mi>N</mml:mi></mml:math></inline-formula>: number of data points; RMSD: root mean square deviation
between predicted (<inline-formula><mml:math display="inline"><mml:mi>P</mml:mi></mml:math></inline-formula>) and observed (<inline-formula><mml:math display="inline"><mml:mi>O</mml:mi></mml:math></inline-formula>)
variables <inline-formula><mml:math display="inline"><mml:mrow><mml:mo>=</mml:mo><mml:msup><mml:mfenced open="[" close="]"><mml:mstyle displaystyle="false"><mml:mfrac style="text"><mml:mn mathvariant="normal">1</mml:mn><mml:mi>N</mml:mi></mml:mfrac></mml:mstyle><mml:mspace linebreak="nobreak" width="0.125em"/><mml:munderover><mml:mo movablelimits="false">∑</mml:mo><mml:mrow><mml:mi>i</mml:mi><mml:mo>=</mml:mo><mml:mn mathvariant="normal">0</mml:mn></mml:mrow><mml:mi>N</mml:mi></mml:munderover><mml:msup><mml:mfenced open="(" close=")"><mml:msub><mml:mi>P</mml:mi><mml:mi>i</mml:mi></mml:msub><mml:mo>-</mml:mo><mml:msub><mml:mi>O</mml:mi><mml:mi>i</mml:mi></mml:msub></mml:mfenced><mml:mn mathvariant="normal">2</mml:mn></mml:msup></mml:mfenced><mml:mn mathvariant="normal">2</mml:mn></mml:msup></mml:mrow></mml:math></inline-formula>.</p></table-wrap-foot></table-wrap>

<?xmltex \floatpos{t}?><table-wrap id="Ch1.T5" specific-use="star"><caption><p>Comparative statistics for the STIC- and tower-derived hourly
<inline-formula><mml:math display="inline"><mml:mrow><mml:mi mathvariant="italic">λ</mml:mi><mml:mi>E</mml:mi></mml:mrow></mml:math></inline-formula> and <inline-formula><mml:math display="inline"><mml:mi>H</mml:mi></mml:math></inline-formula> for a range of PFTs in the Amazon Basin (LBA tower
sites). Values in parentheses are <inline-formula><mml:math display="inline"><mml:mo>±</mml:mo></mml:math></inline-formula>1 standard deviation (standard error
for correlation).</p></caption><oasis:table frame="topbot"><oasis:tgroup cols="11">
     <oasis:colspec colnum="1" colname="col1" align="left"/>
     <oasis:colspec colnum="2" colname="col2" align="center"/>
     <oasis:colspec colnum="3" colname="col3" align="center"/>
     <oasis:colspec colnum="4" colname="col4" align="center"/>
     <oasis:colspec colnum="5" colname="col5" align="center"/>
     <oasis:colspec colnum="6" colname="col6" align="left"/>
     <oasis:colspec colnum="7" colname="col7" align="center"/>
     <oasis:colspec colnum="8" colname="col8" align="center"/>
     <oasis:colspec colnum="9" colname="col9" align="center"/>
     <oasis:colspec colnum="10" colname="col10" align="center" colsep="1"/>
     <oasis:colspec colnum="11" colname="col11" align="center"/>
     <oasis:thead>
       <oasis:row>  
         <oasis:entry colname="col1"/>  
         <oasis:entry rowsep="1" namest="col2" nameend="col5"><inline-formula><mml:math display="inline"><mml:mrow><mml:mi mathvariant="italic">λ</mml:mi><mml:mi>E</mml:mi></mml:mrow></mml:math></inline-formula></oasis:entry>  
         <oasis:entry colname="col6"/>  
         <oasis:entry rowsep="1" namest="col7" nameend="col10" colsep="1"><inline-formula><mml:math display="inline"><mml:mi>H</mml:mi></mml:math></inline-formula></oasis:entry>  
         <oasis:entry colname="col11"/>
       </oasis:row>
       <oasis:row>  
         <oasis:entry colname="col1">PFTs</oasis:entry>  
         <oasis:entry colname="col2">RMSD</oasis:entry>  
         <oasis:entry colname="col3"><inline-formula><mml:math display="inline"><mml:mrow><mml:msup><mml:mi>R</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msup></mml:mrow></mml:math></inline-formula></oasis:entry>  
         <oasis:entry colname="col4">Slope</oasis:entry>  
         <oasis:entry colname="col5">Offset</oasis:entry>  
         <oasis:entry colname="col6"/>  
         <oasis:entry colname="col7">RMSD</oasis:entry>  
         <oasis:entry colname="col8"><inline-formula><mml:math display="inline"><mml:mrow><mml:msup><mml:mi>R</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msup></mml:mrow></mml:math></inline-formula></oasis:entry>  
         <oasis:entry colname="col9">Slope</oasis:entry>  
         <oasis:entry colname="col10">Offset</oasis:entry>  
         <oasis:entry colname="col11"><inline-formula><mml:math display="inline"><mml:mi>N</mml:mi></mml:math></inline-formula></oasis:entry>
       </oasis:row>
       <oasis:row rowsep="1">  
         <oasis:entry colname="col1"/>  
         <oasis:entry colname="col2">(W m<inline-formula><mml:math display="inline"><mml:msup><mml:mi/><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">2</mml:mn></mml:mrow></mml:msup></mml:math></inline-formula>)</oasis:entry>  
         <oasis:entry colname="col3"/>  
         <oasis:entry colname="col4"/>  
         <oasis:entry colname="col5">(W m<inline-formula><mml:math display="inline"><mml:msup><mml:mi/><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">2</mml:mn></mml:mrow></mml:msup></mml:math></inline-formula>)</oasis:entry>  
         <oasis:entry colname="col6"/>  
         <oasis:entry colname="col7">(W m<inline-formula><mml:math display="inline"><mml:msup><mml:mi/><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">2</mml:mn></mml:mrow></mml:msup></mml:math></inline-formula>)</oasis:entry>  
         <oasis:entry colname="col8"/>  
         <oasis:entry colname="col9"/>  
         <oasis:entry colname="col10">(W m<inline-formula><mml:math display="inline"><mml:msup><mml:mi/><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">2</mml:mn></mml:mrow></mml:msup></mml:math></inline-formula>)</oasis:entry>  
         <oasis:entry colname="col11"/>
       </oasis:row>
     </oasis:thead>
     <oasis:tbody>
       <oasis:row>  
         <oasis:entry colname="col1">TRF</oasis:entry>  
         <oasis:entry colname="col2">28</oasis:entry>  
         <oasis:entry colname="col3">0.96</oasis:entry>  
         <oasis:entry colname="col4">1.10</oasis:entry>  
         <oasis:entry colname="col5"><inline-formula><mml:math display="inline"><mml:mo>-</mml:mo></mml:math></inline-formula>16</oasis:entry>  
         <oasis:entry colname="col6"/>  
         <oasis:entry colname="col7">34</oasis:entry>  
         <oasis:entry colname="col8">0.52</oasis:entry>  
         <oasis:entry colname="col9">0.60</oasis:entry>  
         <oasis:entry colname="col10">29</oasis:entry>  
         <oasis:entry colname="col11">1159</oasis:entry>
       </oasis:row>
       <oasis:row rowsep="1">  
         <oasis:entry colname="col1"/>  
         <oasis:entry colname="col2"/>  
         <oasis:entry colname="col3">(<inline-formula><mml:math display="inline"><mml:mo>±</mml:mo></mml:math></inline-formula>0.007)</oasis:entry>  
         <oasis:entry colname="col4">(<inline-formula><mml:math display="inline"><mml:mo>±</mml:mo></mml:math></inline-formula>0.008)</oasis:entry>  
         <oasis:entry colname="col5">(<inline-formula><mml:math display="inline"><mml:mo>±</mml:mo></mml:math></inline-formula>2)</oasis:entry>  
         <oasis:entry colname="col6"/>  
         <oasis:entry colname="col7"/>  
         <oasis:entry colname="col8">(<inline-formula><mml:math display="inline"><mml:mo>±</mml:mo></mml:math></inline-formula>0.030)</oasis:entry>  
         <oasis:entry colname="col9">(<inline-formula><mml:math display="inline"><mml:mo>±</mml:mo></mml:math></inline-formula>0.025)</oasis:entry>  
         <oasis:entry colname="col10">(<inline-formula><mml:math display="inline"><mml:mo>±</mml:mo></mml:math></inline-formula>2)</oasis:entry>  
         <oasis:entry colname="col11"/>
       </oasis:row>
       <oasis:row>  
         <oasis:entry colname="col1">TMF</oasis:entry>  
         <oasis:entry colname="col2">20</oasis:entry>  
         <oasis:entry colname="col3">0.98</oasis:entry>  
         <oasis:entry colname="col4">1.08</oasis:entry>  
         <oasis:entry colname="col5"><inline-formula><mml:math display="inline"><mml:mo>-</mml:mo></mml:math></inline-formula>11</oasis:entry>  
         <oasis:entry colname="col6"/>  
         <oasis:entry colname="col7">23</oasis:entry>  
         <oasis:entry colname="col8">0.71</oasis:entry>  
         <oasis:entry colname="col9">0.61</oasis:entry>  
         <oasis:entry colname="col10">20</oasis:entry>  
         <oasis:entry colname="col11">1927</oasis:entry>
       </oasis:row>
       <oasis:row rowsep="1">  
         <oasis:entry colname="col1"/>  
         <oasis:entry colname="col2"/>  
         <oasis:entry colname="col3">(<inline-formula><mml:math display="inline"><mml:mo>±</mml:mo></mml:math></inline-formula>0.004)</oasis:entry>  
         <oasis:entry colname="col4">(<inline-formula><mml:math display="inline"><mml:mo>±</mml:mo></mml:math></inline-formula>0.004)</oasis:entry>  
         <oasis:entry colname="col5">(<inline-formula><mml:math display="inline"><mml:mo>±</mml:mo></mml:math></inline-formula>1)</oasis:entry>  
         <oasis:entry colname="col6"/>  
         <oasis:entry colname="col7"/>  
         <oasis:entry colname="col8">(<inline-formula><mml:math display="inline"><mml:mo>±</mml:mo></mml:math></inline-formula>0.019)</oasis:entry>  
         <oasis:entry colname="col9">(<inline-formula><mml:math display="inline"><mml:mo>±</mml:mo></mml:math></inline-formula>0.014)</oasis:entry>  
         <oasis:entry colname="col10">(<inline-formula><mml:math display="inline"><mml:mo>±</mml:mo></mml:math></inline-formula>1)</oasis:entry>  
         <oasis:entry colname="col11"/>
       </oasis:row>
       <oasis:row>  
         <oasis:entry colname="col1">TDF</oasis:entry>  
         <oasis:entry colname="col2">26</oasis:entry>  
         <oasis:entry colname="col3">0.96</oasis:entry>  
         <oasis:entry colname="col4">0.96</oasis:entry>  
         <oasis:entry colname="col5"><inline-formula><mml:math display="inline"><mml:mo>-</mml:mo></mml:math></inline-formula>7</oasis:entry>  
         <oasis:entry colname="col6"/>  
         <oasis:entry colname="col7">30</oasis:entry>  
         <oasis:entry colname="col8">0.66</oasis:entry>  
         <oasis:entry colname="col9">0.89</oasis:entry>  
         <oasis:entry colname="col10">20</oasis:entry>  
         <oasis:entry colname="col11">787</oasis:entry>
       </oasis:row>
       <oasis:row rowsep="1">  
         <oasis:entry colname="col1"/>  
         <oasis:entry colname="col2"/>  
         <oasis:entry colname="col3">(<inline-formula><mml:math display="inline"><mml:mo>±</mml:mo></mml:math></inline-formula>0.009)</oasis:entry>  
         <oasis:entry colname="col4">(<inline-formula><mml:math display="inline"><mml:mo>±</mml:mo></mml:math></inline-formula>0.008)</oasis:entry>  
         <oasis:entry colname="col5">(<inline-formula><mml:math display="inline"><mml:mo>±</mml:mo></mml:math></inline-formula>2)</oasis:entry>  
         <oasis:entry colname="col6"/>  
         <oasis:entry colname="col7"/>  
         <oasis:entry colname="col8">(<inline-formula><mml:math display="inline"><mml:mo>±</mml:mo></mml:math></inline-formula>0.032)</oasis:entry>  
         <oasis:entry colname="col9">(<inline-formula><mml:math display="inline"><mml:mo>±</mml:mo></mml:math></inline-formula>0.035)</oasis:entry>  
         <oasis:entry colname="col10">(<inline-formula><mml:math display="inline"><mml:mo>±</mml:mo></mml:math></inline-formula>3)</oasis:entry>  
         <oasis:entry colname="col11"/>
       </oasis:row>
       <oasis:row>  
         <oasis:entry colname="col1">PAS</oasis:entry>  
         <oasis:entry colname="col2">31</oasis:entry>  
         <oasis:entry colname="col3">0.96</oasis:entry>  
         <oasis:entry colname="col4">1.14</oasis:entry>  
         <oasis:entry colname="col5"><inline-formula><mml:math display="inline"><mml:mo>-</mml:mo></mml:math></inline-formula>2</oasis:entry>  
         <oasis:entry colname="col6"/>  
         <oasis:entry colname="col7">33</oasis:entry>  
         <oasis:entry colname="col8">0.88</oasis:entry>  
         <oasis:entry colname="col9">0.67</oasis:entry>  
         <oasis:entry colname="col10">9</oasis:entry>  
         <oasis:entry colname="col11">288</oasis:entry>
       </oasis:row>
       <oasis:row rowsep="1">  
         <oasis:entry colname="col1"/>  
         <oasis:entry colname="col2"/>  
         <oasis:entry colname="col3">(<inline-formula><mml:math display="inline"><mml:mo>±</mml:mo></mml:math></inline-formula>0.009)</oasis:entry>  
         <oasis:entry colname="col4">(<inline-formula><mml:math display="inline"><mml:mo>±</mml:mo></mml:math></inline-formula>0.010)</oasis:entry>  
         <oasis:entry colname="col5">(<inline-formula><mml:math display="inline"><mml:mo>±</mml:mo></mml:math></inline-formula>2)</oasis:entry>  
         <oasis:entry colname="col6"/>  
         <oasis:entry colname="col7"/>  
         <oasis:entry colname="col8">(<inline-formula><mml:math display="inline"><mml:mo>±</mml:mo></mml:math></inline-formula>0.016)</oasis:entry>  
         <oasis:entry colname="col9">(<inline-formula><mml:math display="inline"><mml:mo>±</mml:mo></mml:math></inline-formula>0.011)</oasis:entry>  
         <oasis:entry colname="col10">(<inline-formula><mml:math display="inline"><mml:mo>±</mml:mo></mml:math></inline-formula>1)</oasis:entry>  
         <oasis:entry colname="col11"/>
       </oasis:row>
       <oasis:row>  
         <oasis:entry colname="col1"><bold>Mean</bold></oasis:entry>  
         <oasis:entry colname="col2"><bold>33</bold></oasis:entry>  
         <oasis:entry colname="col3"><bold>0.94</bold></oasis:entry>  
         <oasis:entry colname="col4"><bold>1.04</bold></oasis:entry>  
         <oasis:entry colname="col5"><inline-formula><mml:math display="inline"><mml:mo>-</mml:mo></mml:math></inline-formula><bold>1</bold></oasis:entry>  
         <oasis:entry colname="col6"/>  
         <oasis:entry colname="col7"><bold>37</bold></oasis:entry>  
         <oasis:entry colname="col8"><bold>0.61</bold></oasis:entry>  
         <oasis:entry colname="col9"><bold>0.58</bold></oasis:entry>  
         <oasis:entry colname="col10"><bold>24</bold></oasis:entry>  
         <oasis:entry colname="col11"><bold>4161</bold></oasis:entry>
       </oasis:row>
       <oasis:row>  
         <oasis:entry colname="col1"/>  
         <oasis:entry colname="col2"/>  
         <oasis:entry colname="col3">(<inline-formula><mml:math display="inline"><mml:mo mathvariant="bold">±</mml:mo></mml:math></inline-formula><bold>0.005</bold>)</oasis:entry>  
         <oasis:entry colname="col4">(<inline-formula><mml:math display="inline"><mml:mo mathvariant="bold">±</mml:mo></mml:math></inline-formula><bold>0.005</bold>)</oasis:entry>  
         <oasis:entry colname="col5">(<inline-formula><mml:math display="inline"><mml:mo mathvariant="bold">±</mml:mo></mml:math></inline-formula><bold>1</bold>)</oasis:entry>  
         <oasis:entry colname="col6"/>  
         <oasis:entry colname="col7"/>  
         <oasis:entry colname="col8">(<inline-formula><mml:math display="inline"><mml:mo mathvariant="bold">±</mml:mo></mml:math></inline-formula><bold>0.021</bold>)</oasis:entry>  
         <oasis:entry colname="col9">(<inline-formula><mml:math display="inline"><mml:mo mathvariant="bold">±</mml:mo></mml:math></inline-formula><bold>0.009</bold>)</oasis:entry>  
         <oasis:entry colname="col10">(<inline-formula><mml:math display="inline"><mml:mo mathvariant="bold">±</mml:mo></mml:math></inline-formula><bold>2</bold>)</oasis:entry>  
         <oasis:entry colname="col11"/>
       </oasis:row>
     </oasis:tbody>
   </oasis:tgroup></oasis:table></table-wrap>

      <p>Despite the good agreement between the measured and predicted <inline-formula><mml:math display="inline"><mml:mrow><mml:mi mathvariant="italic">λ</mml:mi><mml:mi>E</mml:mi></mml:mrow></mml:math></inline-formula>
and <inline-formula><mml:math display="inline"><mml:mi>H</mml:mi></mml:math></inline-formula> (Fig. 4, Table 4), the larger error in <inline-formula><mml:math display="inline"><mml:mi>H</mml:mi></mml:math></inline-formula> was associated with the
higher sensitivity of <inline-formula><mml:math display="inline"><mml:mi>H</mml:mi></mml:math></inline-formula> to the errors in <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>T</mml:mi><mml:mtext>R</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> (due to poor
emissivity correction) (Mallick et al., 2015). Since the difference between
<inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>T</mml:mi><mml:mtext>R</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> and <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>T</mml:mi><mml:mtext>A</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> is considered to be the primary driving force
of <inline-formula><mml:math display="inline"><mml:mi>H</mml:mi></mml:math></inline-formula> (van der Tol et al., 2009), the modeled errors in <inline-formula><mml:math display="inline"><mml:mi>H</mml:mi></mml:math></inline-formula> are expected to
arise due to the uncertainties associated with <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>T</mml:mi><mml:mtext>R</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula>.</p>
</sec>
<sec id="Ch1.S5.SS2">
  <?xmltex \opttitle{Canopy coupling, $g_{\text{C}}$, and $g_{\text{A}}$ vs.~transpiration and evaporation}?><title>Canopy coupling, <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>g</mml:mi><mml:mtext>C</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula>, and <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>g</mml:mi><mml:mtext>A</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> vs. transpiration and evaporation</title>
      <p>The correlation analysis between 1 <inline-formula><mml:math display="inline"><mml:mo>-</mml:mo></mml:math></inline-formula> <inline-formula><mml:math display="inline"><mml:mi mathvariant="normal">Ω</mml:mi></mml:math></inline-formula> and <inline-formula><mml:math display="inline"><mml:mrow><mml:mi mathvariant="italic">λ</mml:mi><mml:msub><mml:mi>E</mml:mi><mml:mtext>T</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula>
revealed the extent of biophysical and radiative controls on
<inline-formula><mml:math display="inline"><mml:mrow><mml:mi mathvariant="italic">λ</mml:mi><mml:msub><mml:mi>E</mml:mi><mml:mtext>T</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> (Fig. 5). The degree of biophysical control is a
function of the ratio of <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>g</mml:mi><mml:mtext>C</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> to <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>g</mml:mi><mml:mtext>A</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula>. Minor biophysical
control on <inline-formula><mml:math display="inline"><mml:mrow><mml:mi mathvariant="italic">λ</mml:mi><mml:msub><mml:mi>E</mml:mi><mml:mtext>T</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> was apparent for forest and pasture during
the wet seasons (Fig. 5c and d) as a result of a high
<inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>g</mml:mi><mml:mtext>C</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> / <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>g</mml:mi><mml:mtext>A</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> ratio along with increasing
<inline-formula><mml:math display="inline"><mml:mrow><mml:mi mathvariant="italic">λ</mml:mi><mml:msub><mml:mi>E</mml:mi><mml:mtext>T</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula>. Such conditions stimulate local humidification of air
surrounding the canopy and uncoupling of the in-canopy vapor pressure
deficit (<inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>D</mml:mi><mml:mn mathvariant="normal">0</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula>) from that in the air above (i.e.,
<inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>D</mml:mi><mml:mn mathvariant="normal">0</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> <inline-formula><mml:math display="inline"><mml:mo>&lt;</mml:mo></mml:math></inline-formula> <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>D</mml:mi><mml:mtext>A</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula>) (Meinzer et al., 1997; Motzer et al., 2005)
(Fig. 9a), which implies that <inline-formula><mml:math display="inline"><mml:mrow><mml:mi mathvariant="italic">λ</mml:mi><mml:msub><mml:mi>E</mml:mi><mml:mtext>T</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> becomes largely
independent of <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>g</mml:mi><mml:mtext>C</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula>. By contrast, an enhanced biophysical control on
<inline-formula><mml:math display="inline"><mml:mrow><mml:mi mathvariant="italic">λ</mml:mi><mml:msub><mml:mi>E</mml:mi><mml:mtext>T</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> was apparent during the dry season and drought
year 2005 during the period of reduced water supply, particularly over PAS
(Figs. 5e, f, and 7). Such a condition leads to a relatively dry canopy
surface and substantially high <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>g</mml:mi><mml:mtext>A</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> compared to <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>g</mml:mi><mml:mtext>C</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula>, thus
resulting in low <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>g</mml:mi><mml:mtext>C</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula>/<inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>g</mml:mi><mml:mtext>A</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> ratios regardless of their
absolute values (Meinzer et al., 1993; McNaughton and Jarvis, 1991). Here, a
fractional change in <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>g</mml:mi><mml:mtext>C</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> results in an equivalent fractional change
in <inline-formula><mml:math display="inline"><mml:mrow><mml:mi mathvariant="italic">λ</mml:mi><mml:msub><mml:mi>E</mml:mi><mml:mtext>T</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula>. This impedes transpiration from promoting local
equilibrium of <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>D</mml:mi><mml:mn mathvariant="normal">0</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> and minimizing (or maximizing) the gradient between
<inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>D</mml:mi><mml:mn mathvariant="normal">0</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> and atmospheric vapor pressure deficit (<inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>D</mml:mi><mml:mtext>A</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula>) (i.e.,
<inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>D</mml:mi><mml:mn mathvariant="normal">0</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> <inline-formula><mml:math display="inline"><mml:mo>≅</mml:mo></mml:math></inline-formula> <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>D</mml:mi><mml:mtext>A</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> or <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>D</mml:mi><mml:mn mathvariant="normal">0</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> <inline-formula><mml:math display="inline"><mml:mo>&gt;</mml:mo></mml:math></inline-formula> <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>D</mml:mi><mml:mtext>A</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula>) (Eq. A10)
(Fig. 9a), thereby resulting in strong coupling between <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>D</mml:mi><mml:mn mathvariant="normal">0</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> and
<inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>D</mml:mi><mml:mtext>A</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> (Meinzer et al., 1993; Jarvis and McNaughton, 1986). Besides, a
supplemental biophysical control on <inline-formula><mml:math display="inline"><mml:mrow><mml:mi mathvariant="italic">λ</mml:mi><mml:msub><mml:mi>E</mml:mi><mml:mtext>T</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> might have been
imposed as a consequence of a direct negative feedback of <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>D</mml:mi><mml:mtext>A</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> and
<inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>D</mml:mi><mml:mn mathvariant="normal">0</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> on <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>g</mml:mi><mml:mtext>C</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> (McNaughton and Jarvis, 1991; Jarvis, 1986). An
increase in <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>D</mml:mi><mml:mtext>A</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> (or <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>D</mml:mi><mml:mn mathvariant="normal">0</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula>) beyond a certain limit decreases
<inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>g</mml:mi><mml:mtext>C</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> (Figs. 7 and 8), resulting in a low and narrow increase in
<inline-formula><mml:math display="inline"><mml:mrow><mml:mi mathvariant="italic">λ</mml:mi><mml:msub><mml:mi>E</mml:mi><mml:mtext>T</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula>, despite a steady increase in <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>g</mml:mi><mml:mtext>A</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> and
<inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>R</mml:mi><mml:mtext>N</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula>. The combination of a negative feedback response between
<inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>D</mml:mi><mml:mtext>A</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> and <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>g</mml:mi><mml:mtext>C</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> with the overall radiative–aerodynamic
coupling significantly dampens the variation of transpiration in PAS and TDF
in the dry season, thus featuring increased biophysical control in these
PFTs. These results are in agreement with von Randow et al. (2012), who found
enhanced biophysical control on <inline-formula><mml:math display="inline"><mml:mrow><mml:mi mathvariant="italic">λ</mml:mi><mml:msub><mml:mi>E</mml:mi><mml:mtext>T</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> for the pasture during
the dry season. For the wet season, evidence of minor biophysical control
indicates the dominance of <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>R</mml:mi><mml:mtext>N</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula>-driven equilibrium evaporation in
these PFTs (Hasler and Avissar, 2007; da Rocha et al., 2009; Costa et al.,
2010). In the TRF and TMF, 94 and 99 % of the
retrieved <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>g</mml:mi><mml:mtext>C</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> / <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>g</mml:mi><mml:mtext>A</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> ratios fall above 0.5, and only 1 and
6 % of the retrieved <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>g</mml:mi><mml:mtext>C</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> / <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>g</mml:mi><mml:mtext>A</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> ratios fall below the
0.5 range (Fig. 9b). In contrast, 90 and 73 % of the
<inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>g</mml:mi><mml:mtext>C</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> / <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>g</mml:mi><mml:mtext>A</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> ratios range above 0.5, and 10 to 27 % of the
<inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>g</mml:mi><mml:mtext>C</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> / <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>g</mml:mi><mml:mtext>A</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> ratios were below 0.5 for TDF and PAS,
respectively (Fig. 9b). This shows that, although radiation control is
prevailing in all the sites, biophysical control is relatively stronger in
TDF and PAS as compared to the other sites. For large
<inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>g</mml:mi><mml:mtext>C</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> / <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>g</mml:mi><mml:mtext>A</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> ratios, the conditions within the planetary
boundary layer (PBL) become decoupled from the synoptic scale (McNaughton and
Jarvis, 1991) and the net radiative energy becomes the important regulator of
transpiration. For small <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>g</mml:mi><mml:mtext>C</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> / <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>g</mml:mi><mml:mtext>A</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> ratios (e.g., in the
dry season), the conditions within the PBL are strongly coupled to the
atmosphere above by rapid entrainment of air from the capping inversion and
by some ancillary effects of sensible heat flux on the entrainment
(McNaughton and Jarvis, 1991). These findings substantiate the earlier theory
of McNaughton and Jarvis (1991), who postulated that large
<inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>g</mml:mi><mml:mtext>C</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> / <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>g</mml:mi><mml:mtext>A</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> ratios result in minor biophysical control on
canopy transpiration due to the negative feedback on the canopy from the PBL.
The negative relationship between 1 <inline-formula><mml:math display="inline"><mml:mo>-</mml:mo></mml:math></inline-formula> <inline-formula><mml:math display="inline"><mml:mi mathvariant="normal">Ω</mml:mi></mml:math></inline-formula> and <inline-formula><mml:math display="inline"><mml:mrow><mml:mi mathvariant="italic">λ</mml:mi><mml:msub><mml:mi>E</mml:mi><mml:mtext>E</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula>
(Fig. 5b) over all the PFTs is due to the feedback of <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>g</mml:mi><mml:mtext>A</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> on
<inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>g</mml:mi><mml:mtext>C</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula>. However, over all the PFTs, a combined control of <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>g</mml:mi><mml:mtext>A</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula>
and environmental variables on <inline-formula><mml:math display="inline"><mml:mrow><mml:mi mathvariant="italic">λ</mml:mi><mml:msub><mml:mi>E</mml:mi><mml:mtext>E</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> again highlighted the
impact of realistically estimated <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>g</mml:mi><mml:mtext>A</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> on <inline-formula><mml:math display="inline"><mml:mrow><mml:mi mathvariant="italic">λ</mml:mi><mml:msub><mml:mi>E</mml:mi><mml:mtext>E</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula>
(Holwerda et al., 2012).</p>
      <p>It is important to mention that forests are generally expected to be better
coupled to the atmosphere as compared to the pastures, which is related to
generally higher <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>g</mml:mi><mml:mtext>A</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> of the forests (due to high surface roughness).
This implies that forests exhibit stronger biophysical control on
<inline-formula><mml:math display="inline"><mml:mrow><mml:mi mathvariant="italic">λ</mml:mi><mml:msub><mml:mi>E</mml:mi><mml:mtext>T</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula>. However, due to the broad leaves of the rainforests
(larger leaf area index) and higher surface wetness (due to higher rainfall
amounts), the wet surface area is much larger in the forests than in the
pastures. This results in much higher <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>g</mml:mi><mml:mtext>C</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> values for forests than
for pastures during the wet season (<inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>g</mml:mi><mml:mtext>C</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> <inline-formula><mml:math display="inline"><mml:mo>≈</mml:mo></mml:math></inline-formula> <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>g</mml:mi><mml:mtext>A</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula>),
and <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>g</mml:mi><mml:mtext>C</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> / <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>g</mml:mi><mml:mtext>A</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> <inline-formula><mml:math display="inline"><mml:mo>→</mml:mo></mml:math></inline-formula> 1. Consequently, no significant
difference in coupling was found between them during the wet season (Fig. 5c
and d). Despite the absolute differences in <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>g</mml:mi><mml:mtext>A</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> and <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>g</mml:mi><mml:mtext>C</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula>
between forest and pasture, the high surface wetness is largely offsetting
the expected <inline-formula><mml:math display="inline"><mml:mi mathvariant="normal">Ω</mml:mi></mml:math></inline-formula> difference between them. Although the surface wetness
is substantially lower during the dry season, the high water availability in
the forests due to the deeper root systems helps in maintaining a relatively
high <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>g</mml:mi><mml:mtext>C</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> compared to the pastures. Hence, despite <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>g</mml:mi><mml:mtext>A</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula>
(forest) <inline-formula><mml:math display="inline"><mml:mo>&gt;</mml:mo></mml:math></inline-formula> <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>g</mml:mi><mml:mtext>A</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> (pasture) during the dry season, substantially
lower <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>g</mml:mi><mml:mtext>C</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> values for the pasture result in a lower
<inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>g</mml:mi><mml:mtext>C</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> / <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>g</mml:mi><mml:mtext>A</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> ratio for the pasture compared to the forest,
thus causing more biophysical control on <inline-formula><mml:math display="inline"><mml:mrow><mml:mi mathvariant="italic">λ</mml:mi><mml:msub><mml:mi>E</mml:mi><mml:mtext>T</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> during the dry
season. The relatively better relationship between coupling
vs. <inline-formula><mml:math display="inline"><mml:mrow><mml:mi mathvariant="italic">λ</mml:mi><mml:msub><mml:mi>E</mml:mi><mml:mtext>T</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> in PAS and TDF during the dry season was also
attributed to high surface air temperature differences
(<inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>T</mml:mi><mml:mtext>R</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> <inline-formula><mml:math display="inline"><mml:mo>-</mml:mo></mml:math></inline-formula> <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>T</mml:mi><mml:mtext>A</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula>) in these PFTs that resulted in low
<inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>g</mml:mi><mml:mtext>C</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> / <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>g</mml:mi><mml:mtext>A</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> ratios (Fig. 9c).</p>
</sec>
<sec id="Ch1.S5.SS3">
  <?xmltex \opttitle{Factors affecting $g_{\text{C}}$ and $g_{\text{A}}$ variability}?><title>Factors affecting <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>g</mml:mi><mml:mtext>C</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> and <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>g</mml:mi><mml:mtext>A</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> variability</title>
      <p>The stomatal feedback-response hypothesis (Monteith, 1995) also became
apparent at the canopy scale (Fig. 8a and b), which states that a
decrease in <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>g</mml:mi><mml:mtext>C</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> with increasing <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>D</mml:mi><mml:mtext>A</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> is caused by a direct
increase in <inline-formula><mml:math display="inline"><mml:mrow><mml:mi mathvariant="italic">λ</mml:mi><mml:msub><mml:mi>E</mml:mi><mml:mtext>T</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> (Monteith, 1995; Matzner and Comstock,
2001; Streck, 2003), and <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>g</mml:mi><mml:mtext>C</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> responds to the changes in the air
humidity by sensing <inline-formula><mml:math display="inline"><mml:mrow><mml:mi mathvariant="italic">λ</mml:mi><mml:msub><mml:mi>E</mml:mi><mml:mtext>T</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> rather than <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>D</mml:mi><mml:mtext>A</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula>. This
feedback mechanism is found because of the influence of <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>D</mml:mi><mml:mtext>A</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> on both
<inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>g</mml:mi><mml:mtext>C</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> and <inline-formula><mml:math display="inline"><mml:mrow><mml:mi mathvariant="italic">λ</mml:mi><mml:msub><mml:mi>E</mml:mi><mml:mtext>T</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula>, which in turn changes <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>D</mml:mi><mml:mtext>A</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> by
influencing the air humidity (Monteith, 1995). The change in <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>g</mml:mi><mml:mtext>C</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> is
dominated by an increase in the net available energy, which is partially
offset by an increase in <inline-formula><mml:math display="inline"><mml:mrow><mml:mi mathvariant="italic">λ</mml:mi><mml:msub><mml:mi>E</mml:mi><mml:mtext>T</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula>. After the net energy input in
the canopy exceeds a certain threshold, <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>g</mml:mi><mml:mtext>C</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> starts decreasing even
if <inline-formula><mml:math display="inline"><mml:mrow><mml:mi mathvariant="italic">λ</mml:mi><mml:msub><mml:mi>E</mml:mi><mml:mtext>T</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> increases. High <inline-formula><mml:math display="inline"><mml:mrow><mml:mi mathvariant="italic">λ</mml:mi><mml:msub><mml:mi>E</mml:mi><mml:mtext>T</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> increases the
water potential gradient between guard cells and other epidermal cells or
reduces the bulk leaf water potential, thus causing stomatal closure
(Monteith, 1995; Jones, 1998; Streck, 2003). The control of soil water on
transpiration also became evident from the scatter plots between <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>g</mml:mi><mml:mtext>C</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula>
vs. <inline-formula><mml:math display="inline"><mml:mrow><mml:mi mathvariant="italic">λ</mml:mi><mml:msub><mml:mi>E</mml:mi><mml:mtext>T</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> and <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>T</mml:mi><mml:mtext>R</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> for different <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>D</mml:mi><mml:mtext>A</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> levels
(Figs. 8b, c, and 7). Denmead and Shaw (1962) hypothesized that reduced
<inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>g</mml:mi><mml:mtext>C</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> and stomatal closure occurs at moderate to higher levels of soil
moisture (high <inline-formula><mml:math display="inline"><mml:mrow><mml:mi mathvariant="italic">λ</mml:mi><mml:msub><mml:mi>E</mml:mi><mml:mtext>T</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula>) when the atmospheric demand of water
vapor increases (high <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>D</mml:mi><mml:mtext>A</mml:mtext></mml:msub><mml:mo>)</mml:mo></mml:mrow></mml:math></inline-formula>. The water content in the immediate
vicinity of the plant root depletes rapidly at high <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>D</mml:mi><mml:mtext>A</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula>, which
decreases the hydraulic conductivity of soil, and the soil is unable to
efficiently supply water under these conditions. For a given evaporative
demand and available energy, transpiration is determined by the
<inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>g</mml:mi><mml:mtext>C</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> / <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>g</mml:mi><mml:mtext>A</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> ratio, which is further modulated by the soil
water availability. These combined effects tend to strengthen the biophysical
control on transpiration (Leuzinger and Kirner, 2010; Migletta et al., 2011).
The complex interaction between <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>g</mml:mi><mml:mtext>C</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula>, <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>T</mml:mi><mml:mtext>R</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula>, and <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>D</mml:mi><mml:mtext>A</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula>
(Fig. 8c) explains why different parametric <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>g</mml:mi><mml:mtext>C</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> models produce
divergent results.</p>
      <p>Although <inline-formula><mml:math display="inline"><mml:mrow><mml:mi mathvariant="italic">λ</mml:mi><mml:msub><mml:mi>E</mml:mi><mml:mtext>T</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> and <inline-formula><mml:math display="inline"><mml:mrow><mml:mi mathvariant="italic">λ</mml:mi><mml:msub><mml:mi>E</mml:mi><mml:mtext>E</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> estimates are
interdependent on <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>g</mml:mi><mml:mtext>C</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> and <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>g</mml:mi><mml:mtext>A</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> (as shown in Figs. 6–8), the
figures reflect the credibility of the conductances as well as transpiration
estimates by realistically capturing the hysteretic behavior between
biophysical conductances and water vapor fluxes, which is frequently observed
in natural ecosystems (Zhang et al., 2014; Renner et al., 2016) (also Zuecco
et al., 2016). These results are also compliant with the theories postulated
earlier from observations that the magnitude of hysteresis depends on the
radiation–vapor pressure deficit time lag, while the soil moisture
availability is a key factor modulating the hysteretic transpiration–vapor
pressure deficit relation as soil moisture declines (Zhang et al., 2014;
O'Grady et al., 1999; Jarvis and McNaughton, 1986). This shows that despite
being independent of any predefined hysteretic function, the interdependent
conductance–transpiration hysteresis is still captured in STIC1.2.</p>
      <p>Figure 8d is in accordance with the existing theory that under conditions of
extremely high atmospheric turbulence (i.e., high <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>g</mml:mi><mml:mtext>A</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula>), a close
coupling exists between the surface and the atmosphere, which causes
<inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>T</mml:mi><mml:mtext>R</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> and <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>T</mml:mi><mml:mtext>A</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> to converge (i.e.,
<inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>T</mml:mi><mml:mtext>R</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> <inline-formula><mml:math display="inline"><mml:mo>-</mml:mo></mml:math></inline-formula> <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>T</mml:mi><mml:mtext>A</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> <inline-formula><mml:math display="inline"><mml:mo>→</mml:mo></mml:math></inline-formula> 0). When <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>g</mml:mi><mml:mtext>A</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> is low, the
difference between <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>T</mml:mi><mml:mtext>R</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> and <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>T</mml:mi><mml:mtext>A</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> increases due to poor
vertical mixing of the air.</p>
</sec>
</sec>
<sec id="Ch1.S6" sec-type="conclusions">
  <title>Conclusions</title>
      <p>By integrating the radiometric surface
temperature (<inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>T</mml:mi><mml:mtext>R</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula>) into a combined structure of the PM–SW model, we
have estimated the canopy-scale biophysical conductances and quantified their
control on the terrestrial evapotranspiration components in a simplified SEB
modeling perspective that treats the vegetation canopy as “big-leaf”. The
STIC1.2 biophysical modeling scheme is independent of any leaf-scale
empirical parameterization for stomata and associated aerodynamic variables.</p>
      <p>Stomata regulate the coupling between terrestrial carbon and water cycles,
which implies that their behavior under global environmental change is
critical to predicting vegetation functioning (Medlyn et al., 2011). The
combination of variability in precipitation (Hilker et al., 2014) and land
cover change (Davidson et al., 2012) in the Amazon Basin is expected to
increase the canopy–atmosphere coupling of pasture or forest systems under
drier conditions by altering the ratio of the biological and aerodynamic
conductances. An increase in biophysical control will most likely be an
indicator of shifting the transpiration from an energy-limited to a
water-limited regime (due to the impact of <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>T</mml:mi><mml:mtext>R</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula>, <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>T</mml:mi><mml:mtext>A</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula>, and
<inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>D</mml:mi><mml:mtext>A</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> on the <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>g</mml:mi><mml:mtext>C</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> / <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>g</mml:mi><mml:mtext>A</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> ratio), with further
consequences for the surface water balance and rainfall recycling. At the
same time, a transition from forest to pasture or agriculture lands will
substantially reduce the contribution of interception evaporation in the
Amazon; hence, it will affect the regional water cycle. This might change the
moisture regime of the Amazonian Basin and affect the moisture transport to
other regions. In this context, STIC1.2 provides a new quantitative and
internally consistent method for interpreting the biophysical conductances
and is able to quantify their controls on the water cycle components in
response to a range of climatic and ecohydrological conditions (excluding
rising atmospheric CO<inline-formula><mml:math display="inline"><mml:msub><mml:mi/><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:math></inline-formula>) across a broad spectrum of PFTs. It could also
provide the basis for improving existing land surface parameterizations for
simulating vegetation water use at large spatial scales.</p>
      <p><?xmltex \hack{\newpage}?>It should also be noted that although the case study described here provides
general insights into the biophysical controls of <inline-formula><mml:math display="inline"><mml:mrow><mml:mi mathvariant="italic">λ</mml:mi><mml:mi>E</mml:mi></mml:mrow></mml:math></inline-formula> and associated
feedback between <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>g</mml:mi><mml:mtext>C</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula>, <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>D</mml:mi><mml:mtext>A</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula>, <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>T</mml:mi><mml:mtext>R</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula>, and
<inline-formula><mml:math display="inline"><mml:mrow><mml:mi mathvariant="italic">λ</mml:mi><mml:msub><mml:mi>E</mml:mi><mml:mtext>T</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> in the framework of the PM–SW equation, there is a
tendency to overestimation of <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>g</mml:mi><mml:mtext>C</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> due to the embedded evaporation
information in the current single-source composition of STIC1.2. For accurate
characterization of canopy conductance, explicit partitioning of <inline-formula><mml:math display="inline"><mml:mrow><mml:mi mathvariant="italic">λ</mml:mi><mml:mi>E</mml:mi></mml:mrow></mml:math></inline-formula>
into transpiration and evaporation (both soil and interception) is one of the
further scopes for improving STIC1.2, and this assumption needs to be tested
further.</p>
</sec>
<sec id="Ch1.S7">
  <title>Data availability</title>
      <p>The LBA eddy covariance datasets are available through
<uri>ftp://daac.ornl.gov/data/lba/carbon_dynamics/CD32_Brazil_Flux_Network/</uri> (Saleska et al., 2013).</p><?xmltex \hack{\clearpage}?>
</sec>

      
      </body>
    <back><app-group>

<app id="App1.Ch1.S1">
  <title>Description of STIC1.2</title>
<sec id="App1.Ch1.S1.SS1">
  <title>Derivation of “state equations” in STIC 1.2</title>
      <p>Neglecting horizontal advection and energy storage, the surface energy
balance equation is written as follows:

                <disp-formula id="App1.Ch1.E1" content-type="numbered"><mml:math display="block"><mml:mrow><mml:mi mathvariant="italic">ϕ</mml:mi><mml:mo>=</mml:mo><mml:mi mathvariant="italic">λ</mml:mi><mml:mi>E</mml:mi><mml:mo>+</mml:mo><mml:mi>H</mml:mi><mml:mo>.</mml:mo></mml:mrow></mml:math></disp-formula>

          Figure A1 shows that, while <inline-formula><mml:math display="inline"><mml:mi>H</mml:mi></mml:math></inline-formula> is controlled by a single aerodynamic
resistance (<inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>r</mml:mi><mml:mtext>A</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula>) (or 1/<inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>g</mml:mi><mml:mtext>A</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula>); <inline-formula><mml:math display="inline"><mml:mrow><mml:mi mathvariant="italic">λ</mml:mi><mml:mi>E</mml:mi></mml:mrow></mml:math></inline-formula> is controlled by two
resistances in series, the surface resistance (<inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>r</mml:mi><mml:mtext>C</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula>) (or 1/<inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>g</mml:mi><mml:mtext>C</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula>) and the
aerodynamic resistance to vapor transfer (<inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>r</mml:mi><mml:mtext>C</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> <inline-formula><mml:math display="inline"><mml:mo>+</mml:mo></mml:math></inline-formula> <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>r</mml:mi><mml:mtext>A</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula>). For
simplicity, it is implicitly assumed that the aerodynamic resistance of
water vapor and heat are equal (Raupach, 1998), and both the fluxes are
transported from the same level from near surface to the atmosphere. The
sensible and latent heat flux can be expressed in the form of aerodynamic
transfer equations (Boegh et al., 2002; Boegh and Soegaard, 2004) as follows:

                <disp-formula specific-use="align" content-type="numbered"><mml:math display="block"><mml:mtable displaystyle="true"><mml:mlabeledtr id="App1.Ch1.E2"><mml:mtd/><mml:mtd/><mml:mtd><mml:mrow><mml:mi>H</mml:mi><mml:mo>=</mml:mo><mml:mi mathvariant="italic">ρ</mml:mi><mml:mspace linebreak="nobreak" width="0.125em"/><mml:msub><mml:mi>c</mml:mi><mml:mi>P</mml:mi></mml:msub><mml:mspace width="0.125em" linebreak="nobreak"/><mml:msub><mml:mi>g</mml:mi><mml:mtext>A</mml:mtext></mml:msub><mml:mfenced open="(" close=")"><mml:msub><mml:mi>T</mml:mi><mml:mn mathvariant="normal">0</mml:mn></mml:msub><mml:mo>-</mml:mo><mml:msub><mml:mi>T</mml:mi><mml:mtext>A</mml:mtext></mml:msub></mml:mfenced></mml:mrow></mml:mtd></mml:mlabeledtr><mml:mlabeledtr id="App1.Ch1.E3"><mml:mtd/><mml:mtd/><mml:mtd><mml:mrow><mml:mi mathvariant="italic">λ</mml:mi><mml:mi>E</mml:mi><mml:mo>=</mml:mo><mml:mstyle displaystyle="true"><mml:mfrac style="display"><mml:mrow><mml:mi mathvariant="italic">ρ</mml:mi><mml:mspace linebreak="nobreak" width="0.125em"/><mml:msub><mml:mi>c</mml:mi><mml:mi>P</mml:mi></mml:msub></mml:mrow><mml:mi mathvariant="italic">γ</mml:mi></mml:mfrac></mml:mstyle><mml:msub><mml:mi>g</mml:mi><mml:mtext>A</mml:mtext></mml:msub><mml:mfenced open="(" close=")"><mml:msub><mml:mi>e</mml:mi><mml:mn mathvariant="normal">0</mml:mn></mml:msub><mml:mo>-</mml:mo><mml:msub><mml:mi>e</mml:mi><mml:mtext>A</mml:mtext></mml:msub></mml:mfenced><mml:mo>=</mml:mo><mml:mstyle displaystyle="true"><mml:mfrac style="display"><mml:mrow><mml:mi mathvariant="italic">ρ</mml:mi><mml:mspace linebreak="nobreak" width="0.125em"/><mml:msub><mml:mi>c</mml:mi><mml:mi>P</mml:mi></mml:msub></mml:mrow><mml:mi mathvariant="italic">γ</mml:mi></mml:mfrac></mml:mstyle><mml:msub><mml:mi>g</mml:mi><mml:mtext>C</mml:mtext></mml:msub><mml:mfenced open="(" close=")"><mml:msubsup><mml:mi>e</mml:mi><mml:mn mathvariant="normal">0</mml:mn><mml:mo>*</mml:mo></mml:msubsup><mml:mo>-</mml:mo><mml:msub><mml:mi>e</mml:mi><mml:mn mathvariant="normal">0</mml:mn></mml:msub></mml:mfenced></mml:mrow></mml:mtd></mml:mlabeledtr></mml:mtable></mml:math></disp-formula>

            where <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>T</mml:mi><mml:mn mathvariant="normal">0</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> and <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>e</mml:mi><mml:mn mathvariant="normal">0</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> are the air temperature and vapor pressure at the
source/sink height (i.e., aerodynamic temperature and vapor pressure) or at
the so-called roughness length (<inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>z</mml:mi><mml:mn mathvariant="normal">0</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula>), where wind speed is zero. They
represent the vapor pressure and temperature of the quasi-laminar boundary
layer in the immediate vicinity of the surface level (Fig. A1), and
<inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>T</mml:mi><mml:mn mathvariant="normal">0</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> can be obtained by extrapolating the logarithmic profile of <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>T</mml:mi><mml:mtext>A</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula>
down to <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>z</mml:mi><mml:mn mathvariant="normal">0</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula>. <inline-formula><mml:math display="inline"><mml:mrow><mml:msubsup><mml:mi>e</mml:mi><mml:mn mathvariant="normal">0</mml:mn><mml:mo>*</mml:mo></mml:msubsup></mml:mrow></mml:math></inline-formula> is the saturation vapor pressure at <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>T</mml:mi><mml:mn mathvariant="normal">0</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> (hPa).</p>
      <p>By combining Eqs. (A1)–(A3) and solving for <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>g</mml:mi><mml:mtext>A</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula>, we get the following equation.

                <disp-formula id="App1.Ch1.E4" content-type="numbered"><mml:math display="block"><mml:mrow><mml:msub><mml:mi>g</mml:mi><mml:mtext>A</mml:mtext></mml:msub><mml:mo>=</mml:mo><mml:mstyle displaystyle="true"><mml:mfrac style="display"><mml:mi mathvariant="italic">ϕ</mml:mi><mml:mrow><mml:mi mathvariant="italic">ρ</mml:mi><mml:msub><mml:mi>c</mml:mi><mml:mi>P</mml:mi></mml:msub></mml:mrow></mml:mfrac></mml:mstyle><mml:mfenced close="]" open="["><mml:mfenced close=")" open="("><mml:msub><mml:mi>T</mml:mi><mml:mn mathvariant="normal">0</mml:mn></mml:msub><mml:mo>-</mml:mo><mml:msub><mml:mi>T</mml:mi><mml:mtext>A</mml:mtext></mml:msub></mml:mfenced><mml:mo>+</mml:mo><mml:mfenced open="(" close=")"><mml:mstyle displaystyle="true"><mml:mfrac style="display"><mml:mrow><mml:msub><mml:mi>e</mml:mi><mml:mn mathvariant="normal">0</mml:mn></mml:msub><mml:mo>-</mml:mo><mml:msub><mml:mi>e</mml:mi><mml:mtext>A</mml:mtext></mml:msub></mml:mrow><mml:mi mathvariant="italic">γ</mml:mi></mml:mfrac></mml:mstyle></mml:mfenced></mml:mfenced></mml:mrow></mml:math></disp-formula></p>
      <p>Combining the aerodynamic expressions of <inline-formula><mml:math display="inline"><mml:mrow><mml:mi mathvariant="italic">λ</mml:mi><mml:mi>E</mml:mi></mml:mrow></mml:math></inline-formula> in Eq. (A3) and solving
for <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>g</mml:mi><mml:mtext>C</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula>, we can express <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>g</mml:mi><mml:mtext>C</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> in terms of <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>g</mml:mi><mml:mtext>A</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula>, <inline-formula><mml:math display="inline"><mml:mrow><mml:msubsup><mml:mi>e</mml:mi><mml:mn mathvariant="normal">0</mml:mn><mml:mo>*</mml:mo></mml:msubsup></mml:mrow></mml:math></inline-formula>,
<inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>e</mml:mi><mml:mn mathvariant="normal">0</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula>, and <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>e</mml:mi><mml:mtext>A</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula>.

                <disp-formula id="App1.Ch1.E5" content-type="numbered"><mml:math display="block"><mml:mrow><mml:msub><mml:mi>g</mml:mi><mml:mtext>C</mml:mtext></mml:msub><mml:mo>=</mml:mo><mml:msub><mml:mi>g</mml:mi><mml:mtext>A</mml:mtext></mml:msub><mml:mstyle displaystyle="true"><mml:mfrac style="display"><mml:mrow><mml:mfenced close=")" open="("><mml:msub><mml:mi>e</mml:mi><mml:mn mathvariant="normal">0</mml:mn></mml:msub><mml:mo>-</mml:mo><mml:msub><mml:mi>e</mml:mi><mml:mtext>A</mml:mtext></mml:msub></mml:mfenced></mml:mrow><mml:mrow><mml:mfenced close=")" open="("><mml:msubsup><mml:mi>e</mml:mi><mml:mn mathvariant="normal">0</mml:mn><mml:mo>*</mml:mo></mml:msubsup><mml:mo>-</mml:mo><mml:msub><mml:mi>e</mml:mi><mml:mn mathvariant="normal">0</mml:mn></mml:msub></mml:mfenced></mml:mrow></mml:mfrac></mml:mstyle></mml:mrow></mml:math></disp-formula></p>
      <p>While deriving the expressions for <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>g</mml:mi><mml:mtext>A</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> and <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>g</mml:mi><mml:mtext>C</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula>, two more unknown
variables are introduced (<inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>e</mml:mi><mml:mn mathvariant="normal">0</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> and <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>T</mml:mi><mml:mn mathvariant="normal">0</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula>), thus there are two equations
and four unknowns. Therefore, two more equations are needed to close the
system of equations.</p>
      <p>An expression for <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>T</mml:mi><mml:mn mathvariant="normal">0</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> is derived from the Bowen ratio (<inline-formula><mml:math display="inline"><mml:mi mathvariant="italic">β</mml:mi></mml:math></inline-formula>) (Bowen,
1926) and evaporative fraction (<inline-formula><mml:math display="inline"><mml:mi mathvariant="normal">Λ</mml:mi></mml:math></inline-formula>) (Shuttleworth et al., 1989) equation.

                <disp-formula specific-use="align" content-type="numbered"><mml:math display="block"><mml:mtable displaystyle="true"><mml:mlabeledtr id="App1.Ch1.E6"><mml:mtd/><mml:mtd/><mml:mtd><mml:mrow><mml:mi mathvariant="italic">β</mml:mi><mml:mo>=</mml:mo><mml:mfenced close=")" open="("><mml:mstyle displaystyle="true"><mml:mfrac style="display"><mml:mrow><mml:mn mathvariant="normal">1</mml:mn><mml:mo>-</mml:mo><mml:mi mathvariant="normal">Λ</mml:mi></mml:mrow><mml:mi mathvariant="normal">Λ</mml:mi></mml:mfrac></mml:mstyle></mml:mfenced><mml:mo>=</mml:mo><mml:mstyle displaystyle="true"><mml:mfrac style="display"><mml:mrow><mml:mi mathvariant="italic">γ</mml:mi><mml:mfenced close=")" open="("><mml:msub><mml:mi>T</mml:mi><mml:mn mathvariant="normal">0</mml:mn></mml:msub><mml:mo>-</mml:mo><mml:msub><mml:mi>T</mml:mi><mml:mtext>A</mml:mtext></mml:msub></mml:mfenced></mml:mrow><mml:mrow><mml:mfenced open="(" close=")"><mml:msub><mml:mi>e</mml:mi><mml:mn mathvariant="normal">0</mml:mn></mml:msub><mml:mo>-</mml:mo><mml:msub><mml:mi>e</mml:mi><mml:mtext>A</mml:mtext></mml:msub></mml:mfenced></mml:mrow></mml:mfrac></mml:mstyle></mml:mrow></mml:mtd></mml:mlabeledtr><mml:mlabeledtr id="App1.Ch1.E7"><mml:mtd/><mml:mtd/><mml:mtd><mml:mrow><mml:msub><mml:mi>T</mml:mi><mml:mn mathvariant="normal">0</mml:mn></mml:msub><mml:mo>=</mml:mo><mml:msub><mml:mi>T</mml:mi><mml:mtext>A</mml:mtext></mml:msub><mml:mo>+</mml:mo><mml:mfenced close=")" open="("><mml:mstyle displaystyle="true"><mml:mfrac style="display"><mml:mrow><mml:msub><mml:mi>e</mml:mi><mml:mn mathvariant="normal">0</mml:mn></mml:msub><mml:mo>-</mml:mo><mml:msub><mml:mi>e</mml:mi><mml:mtext>A</mml:mtext></mml:msub></mml:mrow><mml:mi mathvariant="italic">γ</mml:mi></mml:mfrac></mml:mstyle></mml:mfenced><mml:mfenced open="(" close=")"><mml:mstyle displaystyle="true"><mml:mfrac style="display"><mml:mrow><mml:mn mathvariant="normal">1</mml:mn><mml:mo>-</mml:mo><mml:mi mathvariant="normal">Λ</mml:mi></mml:mrow><mml:mi mathvariant="normal">Λ</mml:mi></mml:mfrac></mml:mstyle></mml:mfenced></mml:mrow></mml:mtd></mml:mlabeledtr></mml:mtable></mml:math></disp-formula></p>

      <?xmltex \floatpos{t}?><fig id="App1.Ch1.F1"><caption><p>Schematic representation of the one-dimensional description of
STIC1.2. In STIC1.2, a feedback is established between the surface-layer
evaporative fluxes and source/sink height mixing and coupling, and the
connection is shown in dotted arrows between <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>e</mml:mi><mml:mn mathvariant="normal">0</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula>, <inline-formula><mml:math display="inline"><mml:mrow><mml:msubsup><mml:mi>e</mml:mi><mml:mn mathvariant="normal">0</mml:mn><mml:mo>*</mml:mo></mml:msubsup></mml:mrow></mml:math></inline-formula>,
<inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>g</mml:mi><mml:mtext>A</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula>, <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>g</mml:mi><mml:mtext>C</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula>, and <inline-formula><mml:math display="inline"><mml:mrow><mml:mi mathvariant="italic">λ</mml:mi><mml:mi>E</mml:mi></mml:mrow></mml:math></inline-formula>. Here, <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>r</mml:mi><mml:mtext>A</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> and
<inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>r</mml:mi><mml:mtext>C</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> are the aerodynamic and canopy (or surface in the case of
partial vegetation cover) resistances, <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>g</mml:mi><mml:mtext>A</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> and <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>g</mml:mi><mml:mtext>C</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> are the
aerodynamic and canopy conductances (reciprocal of resistances),
<inline-formula><mml:math display="inline"><mml:mrow><mml:msubsup><mml:mi>e</mml:mi><mml:mtext>S</mml:mtext><mml:mo>*</mml:mo></mml:msubsup></mml:mrow></mml:math></inline-formula> is the saturation vapor pressure of the surface, <inline-formula><mml:math display="inline"><mml:mrow><mml:msubsup><mml:mi>e</mml:mi><mml:mn mathvariant="normal">0</mml:mn><mml:mo>*</mml:mo></mml:msubsup></mml:mrow></mml:math></inline-formula>
is the saturation vapor pressure at the source/sink height, <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>T</mml:mi><mml:mn mathvariant="normal">0</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> is the
source/sink height temperature (i.e., aerodynamic temperature) that is
responsible for transferring the sensible heat (<inline-formula><mml:math display="inline"><mml:mi>H</mml:mi></mml:math></inline-formula>), <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>e</mml:mi><mml:mn mathvariant="normal">0</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> is the
source/sink height vapor pressure, <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>e</mml:mi><mml:mtext>S</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> is the vapor pressure at the
surface, <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>z</mml:mi><mml:mn mathvariant="normal">0</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> is the roughness length, <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>T</mml:mi><mml:mtext>R</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> is the radiometric
surface temperature, <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>T</mml:mi><mml:mtext>SD</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> is the source/sink height dew-point
temperature, <inline-formula><mml:math display="inline"><mml:mi>M</mml:mi></mml:math></inline-formula> is the surface moisture availability or evaporation
coefficient, <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>R</mml:mi><mml:mtext>N</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> and <inline-formula><mml:math display="inline"><mml:mi>G</mml:mi></mml:math></inline-formula> are net radiation and ground heat flux,
<inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>T</mml:mi><mml:mtext>A</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula>, <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>e</mml:mi><mml:mtext>A</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula>, and <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>D</mml:mi><mml:mtext>A</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> are temperature, vapor pressure,
and vapor pressure deficit at the reference height (<inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>z</mml:mi><mml:mtext>R</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula>),
<inline-formula><mml:math display="inline"><mml:mrow><mml:mi mathvariant="italic">λ</mml:mi><mml:mi>E</mml:mi></mml:mrow></mml:math></inline-formula> is the latent heat flux, and <inline-formula><mml:math display="inline"><mml:mi>H</mml:mi></mml:math></inline-formula> is the sensible heat flux,
respectively.</p></caption>
          <?xmltex \igopts{width=236.157874pt}?><graphic xlink:href="https://hess.copernicus.org/articles/20/4237/2016/hess-20-4237-2016-f10.pdf"/>

        </fig>

      <?xmltex \floatpos{t}?><fig id="App1.Ch1.F2"><caption><p>Aerodynamic temperature obtained from STIC1.2 (<inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>T</mml:mi><mml:mtext>0-STIC</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula>)
vs. radiometric surface temperature (<inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>T</mml:mi><mml:mtext>R</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula>) over two different biomes
in the Amazon Basin. The regression equation of line of best fit is
<inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>T</mml:mi><mml:mtext>0-STIC</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> <inline-formula><mml:math display="inline"><mml:mo>=</mml:mo></mml:math></inline-formula> 0.67 (<inline-formula><mml:math display="inline"><mml:mo>±</mml:mo></mml:math></inline-formula>0.10) <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>T</mml:mi><mml:mtext>R</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> <inline-formula><mml:math display="inline"><mml:mo>+</mml:mo></mml:math></inline-formula> 10.59 (<inline-formula><mml:math display="inline"><mml:mo>±</mml:mo></mml:math></inline-formula>2.79)
with <inline-formula><mml:math display="inline"><mml:mi>r</mml:mi></mml:math></inline-formula> <inline-formula><mml:math display="inline"><mml:mo>=</mml:mo></mml:math></inline-formula> 0.65.</p></caption>
          <?xmltex \igopts{width=199.169291pt}?><graphic xlink:href="https://hess.copernicus.org/articles/20/4237/2016/hess-20-4237-2016-f11.pdf"/>

        </fig>

      <p>This expression for <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>T</mml:mi><mml:mn mathvariant="normal">0</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> introduces another new variable (<inline-formula><mml:math display="inline"><mml:mi mathvariant="normal">Λ</mml:mi></mml:math></inline-formula>);
therefore, one more equation that describes the dependence of <inline-formula><mml:math display="inline"><mml:mi mathvariant="normal">Λ</mml:mi></mml:math></inline-formula> on
the conductances (<inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>g</mml:mi><mml:mtext>A</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> and <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>g</mml:mi><mml:mtext>C</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula>) is needed to close the
system of equations. In order to express <inline-formula><mml:math display="inline"><mml:mi mathvariant="normal">Λ</mml:mi></mml:math></inline-formula> in terms of <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>g</mml:mi><mml:mtext>A</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula>
and <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>g</mml:mi><mml:mtext>C</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula>, we had adopted the advection–aridity (AA) hypothesis
(Brutsaert and Stricker, 1979) with a modification introduced by Mallick et
al. (2015). The AA hypothesis is based on a complementary connection between
the potential evaporation (<inline-formula><mml:math display="inline"><mml:mrow><mml:msup><mml:mi>E</mml:mi><mml:mo>*</mml:mo></mml:msup></mml:mrow></mml:math></inline-formula>), sensible heat flux (<inline-formula><mml:math display="inline"><mml:mi>H</mml:mi></mml:math></inline-formula>), and <inline-formula><mml:math display="inline"><mml:mi>E</mml:mi></mml:math></inline-formula>; and
leads to an assumed link between <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>g</mml:mi><mml:mtext>A</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> and <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>T</mml:mi><mml:mn mathvariant="normal">0</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula>. However, the
effects of surface moisture (or water stress) were not explicit in the AA
equation, and Mallick et al. (2015) implemented a moisture constraint in the
original AA hypothesis while deriving a “state equation” of <inline-formula><mml:math display="inline"><mml:mi mathvariant="normal">Λ</mml:mi></mml:math></inline-formula>
(Eq. A8 below). A detailed derivation of the “state equation” for <inline-formula><mml:math display="inline"><mml:mi mathvariant="normal">Λ</mml:mi></mml:math></inline-formula>
is described in Supplement S1 (also see Mallick et al., 2014, 2015).
Estimation of <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>e</mml:mi><mml:mn mathvariant="normal">0</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula>, <inline-formula><mml:math display="inline"><mml:mrow><mml:msubsup><mml:mi>e</mml:mi><mml:mn mathvariant="normal">0</mml:mn><mml:mo>*</mml:mo></mml:msubsup></mml:mrow></mml:math></inline-formula>, <inline-formula><mml:math display="inline"><mml:mi>M</mml:mi></mml:math></inline-formula>, and <inline-formula><mml:math display="inline"><mml:mi mathvariant="italic">α</mml:mi></mml:math></inline-formula> is described in
Appendix A2.

                <disp-formula id="App1.Ch1.E8" content-type="numbered"><mml:math display="block"><mml:mrow><mml:mi mathvariant="normal">Λ</mml:mi><mml:mo>=</mml:mo><mml:mstyle displaystyle="true"><mml:mfrac style="display"><mml:mrow><mml:mn mathvariant="normal">2</mml:mn><mml:mi mathvariant="italic">α</mml:mi><mml:mi>s</mml:mi></mml:mrow><mml:mrow><mml:mn mathvariant="normal">2</mml:mn><mml:mi>s</mml:mi><mml:mo>+</mml:mo><mml:mn mathvariant="normal">2</mml:mn><mml:mi mathvariant="italic">γ</mml:mi><mml:mo>+</mml:mo><mml:mi mathvariant="italic">γ</mml:mi><mml:mstyle displaystyle="false"><mml:mfrac style="text"><mml:mrow><mml:msub><mml:mi>g</mml:mi><mml:mtext>A</mml:mtext></mml:msub></mml:mrow><mml:mrow><mml:msub><mml:mi>g</mml:mi><mml:mtext>C</mml:mtext></mml:msub></mml:mrow></mml:mfrac></mml:mstyle><mml:mo>(</mml:mo><mml:mn mathvariant="normal">1</mml:mn><mml:mo>+</mml:mo><mml:mi>M</mml:mi><mml:mo>)</mml:mo></mml:mrow></mml:mfrac></mml:mstyle></mml:mrow></mml:math></disp-formula></p>
</sec>
<sec id="App1.Ch1.S1.SS2">
  <?xmltex \opttitle{Iterative solution of $e_{{0}}$, $e_{{0}}^{{*}}$, $M$, and $\alpha$ in STIC~1.2}?><title>Iterative solution of <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>e</mml:mi><mml:mn mathvariant="normal">0</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula>, <inline-formula><mml:math display="inline"><mml:mrow><mml:msubsup><mml:mi>e</mml:mi><mml:mn mathvariant="normal">0</mml:mn><mml:mo>*</mml:mo></mml:msubsup></mml:mrow></mml:math></inline-formula>, <inline-formula><mml:math display="inline"><mml:mi>M</mml:mi></mml:math></inline-formula>, and <inline-formula><mml:math display="inline"><mml:mi mathvariant="italic">α</mml:mi></mml:math></inline-formula> in STIC 1.2</title>
      <p>In STIC1.0 and 1.1 (Mallick et al., 2014, 2015), no distinction was made
between the surface and source/sink height vapor pressures. Therefore,
<inline-formula><mml:math display="inline"><mml:mrow><mml:msubsup><mml:mi>e</mml:mi><mml:mn mathvariant="normal">0</mml:mn><mml:mo>*</mml:mo></mml:msubsup></mml:mrow></mml:math></inline-formula> was approximated as the saturation vapor pressure at <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>T</mml:mi><mml:mtext>R</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula>
and <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>e</mml:mi><mml:mn mathvariant="normal">0</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> was empirically estimated from <inline-formula><mml:math display="inline"><mml:mi>M</mml:mi></mml:math></inline-formula> based on the assumption that
the vapor pressure at the source/sink height ranges between extreme wet–dry
surface conditions. However, the level of <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>e</mml:mi><mml:mn mathvariant="normal">0</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> and <inline-formula><mml:math display="inline"><mml:mrow><mml:msubsup><mml:mi>e</mml:mi><mml:mn mathvariant="normal">0</mml:mn><mml:mo>*</mml:mo></mml:msubsup></mml:mrow></mml:math></inline-formula> should be
consistent with the level of the aerodynamic temperature (<inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>T</mml:mi><mml:mn mathvariant="normal">0</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula>) from which
the sensible heat flux is transferred (Lhomme and Montes, 2014). The
predictive use of the PM model could be hindered by neglecting of the
feedbacks between the surface-layer evaporative fluxes and source/sink height
mixing and coupling (McNaughton and Jarvis, 1984) and their impact on the
canopy-scale conductances. Therefore, in STIC1.2, we have used physical
expressions for estimating <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>e</mml:mi><mml:mn mathvariant="normal">0</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> and <inline-formula><mml:math display="inline"><mml:mrow><mml:msubsup><mml:mi>e</mml:mi><mml:mn mathvariant="normal">0</mml:mn><mml:mo>*</mml:mo></mml:msubsup></mml:mrow></mml:math></inline-formula> followed by estimating
<inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>T</mml:mi><mml:mtext>SD</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> and <inline-formula><mml:math display="inline"><mml:mi>M</mml:mi></mml:math></inline-formula> as described below. The fundamental differences between
the STIC1.0, 1.1, and 1.2 modeling philosophies are described in Table A1.</p>
      <p>An estimate of <inline-formula><mml:math display="inline"><mml:mrow><mml:msubsup><mml:mi>e</mml:mi><mml:mn mathvariant="normal">0</mml:mn><mml:mo>*</mml:mo></mml:msubsup></mml:mrow></mml:math></inline-formula> is obtained by inverting the aerodynamic transfer
equation of <inline-formula><mml:math display="inline"><mml:mrow><mml:mi mathvariant="italic">λ</mml:mi><mml:mi>E</mml:mi></mml:mrow></mml:math></inline-formula>.

                <disp-formula id="App1.Ch1.E9" content-type="numbered"><mml:math display="block"><mml:mrow><mml:msubsup><mml:mi>e</mml:mi><mml:mn mathvariant="normal">0</mml:mn><mml:mo>*</mml:mo></mml:msubsup><mml:mo>=</mml:mo><mml:msub><mml:mi>e</mml:mi><mml:mtext>A</mml:mtext></mml:msub><mml:mo>+</mml:mo><mml:mfenced close="]" open="["><mml:mstyle displaystyle="true"><mml:mfrac style="display"><mml:mrow><mml:mi mathvariant="italic">γ</mml:mi><mml:mi mathvariant="italic">λ</mml:mi><mml:mi>E</mml:mi><mml:mfenced close=")" open="("><mml:msub><mml:mi>g</mml:mi><mml:mtext>A</mml:mtext></mml:msub><mml:mo>+</mml:mo><mml:msub><mml:mi>g</mml:mi><mml:mtext>C</mml:mtext></mml:msub></mml:mfenced></mml:mrow><mml:mrow><mml:mi mathvariant="italic">ρ</mml:mi><mml:msub><mml:mi>c</mml:mi><mml:mi>P</mml:mi></mml:msub><mml:msub><mml:mi>g</mml:mi><mml:mtext>A</mml:mtext></mml:msub><mml:msub><mml:mi>g</mml:mi><mml:mtext>C</mml:mtext></mml:msub></mml:mrow></mml:mfrac></mml:mstyle></mml:mfenced></mml:mrow></mml:math></disp-formula></p>
      <p>Following Shuttleworth and Wallace (1985) (SW), the vapor pressure deficit (<inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>D</mml:mi><mml:mn mathvariant="normal">0</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula>)
(<inline-formula><mml:math display="inline"><mml:mo>=</mml:mo></mml:math></inline-formula> <inline-formula><mml:math display="inline"><mml:mrow><mml:msubsup><mml:mi>e</mml:mi><mml:mn mathvariant="normal">0</mml:mn><mml:mo>*</mml:mo></mml:msubsup></mml:mrow></mml:math></inline-formula> <inline-formula><mml:math display="inline"><mml:mo>-</mml:mo></mml:math></inline-formula> <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>e</mml:mi><mml:mn mathvariant="normal">0</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula>) and vapor pressure (<inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>e</mml:mi><mml:mn mathvariant="normal">0</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula>) at the source/sink
height are expressed as follows.

                <disp-formula specific-use="align" content-type="numbered"><mml:math display="block"><mml:mtable displaystyle="true"><mml:mlabeledtr id="App1.Ch1.E10"><mml:mtd/><mml:mtd/><mml:mtd><mml:mrow><mml:msub><mml:mi>D</mml:mi><mml:mn mathvariant="normal">0</mml:mn></mml:msub><mml:mo>=</mml:mo><mml:msub><mml:mi>D</mml:mi><mml:mtext>A</mml:mtext></mml:msub><mml:mo>+</mml:mo><mml:mfenced open="[" close="]"><mml:mstyle displaystyle="true"><mml:mfrac style="display"><mml:mrow><mml:mo mathvariant="italic">{</mml:mo><mml:mi>s</mml:mi><mml:mi mathvariant="italic">ϕ</mml:mi><mml:mo>-</mml:mo><mml:mo>(</mml:mo><mml:mi>s</mml:mi><mml:mo>+</mml:mo><mml:mi mathvariant="italic">γ</mml:mi><mml:mo>)</mml:mo><mml:mi mathvariant="italic">λ</mml:mi><mml:mi>E</mml:mi><mml:mo mathvariant="italic">}</mml:mo></mml:mrow><mml:mrow><mml:mi mathvariant="italic">ρ</mml:mi><mml:msub><mml:mi>c</mml:mi><mml:mi>P</mml:mi></mml:msub><mml:msub><mml:mi>g</mml:mi><mml:mtext>A</mml:mtext></mml:msub></mml:mrow></mml:mfrac></mml:mstyle></mml:mfenced></mml:mrow></mml:mtd></mml:mlabeledtr><mml:mlabeledtr id="App1.Ch1.E11"><mml:mtd/><mml:mtd/><mml:mtd><mml:mrow><mml:msub><mml:mi>e</mml:mi><mml:mn mathvariant="normal">0</mml:mn></mml:msub><mml:mo>=</mml:mo><mml:msubsup><mml:mi>e</mml:mi><mml:mn mathvariant="normal">0</mml:mn><mml:mo>*</mml:mo></mml:msubsup><mml:mo>-</mml:mo><mml:msub><mml:mi>D</mml:mi><mml:mn mathvariant="normal">0</mml:mn></mml:msub></mml:mrow></mml:mtd></mml:mlabeledtr></mml:mtable></mml:math></disp-formula></p>
      <p>A physical equation of <inline-formula><mml:math display="inline"><mml:mi mathvariant="italic">α</mml:mi></mml:math></inline-formula> is derived by expressing the evaporative
fraction (<inline-formula><mml:math display="inline"><mml:mi mathvariant="normal">Λ</mml:mi></mml:math></inline-formula>) as a function of the aerodynamic equations of <inline-formula><mml:math display="inline"><mml:mi>H</mml:mi></mml:math></inline-formula>
[<inline-formula><mml:math display="inline"><mml:mrow><mml:mi mathvariant="italic">ρ</mml:mi><mml:msub><mml:mi>c</mml:mi><mml:mi>P</mml:mi></mml:msub><mml:mspace linebreak="nobreak" width="0.125em"/><mml:msub><mml:mi>g</mml:mi><mml:mtext>A</mml:mtext></mml:msub><mml:mo>(</mml:mo><mml:msub><mml:mi>T</mml:mi><mml:mn mathvariant="normal">0</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> <inline-formula><mml:math display="inline"><mml:mo>-</mml:mo></mml:math></inline-formula> <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>T</mml:mi><mml:mtext>A</mml:mtext></mml:msub><mml:mo>)</mml:mo></mml:mrow></mml:math></inline-formula>] and <inline-formula><mml:math display="inline"><mml:mrow><mml:mi mathvariant="italic">λ</mml:mi><mml:mi>E</mml:mi></mml:mrow></mml:math></inline-formula>
[<inline-formula><mml:math display="inline"><mml:mrow><mml:mstyle displaystyle="false"><mml:mfrac style="text"><mml:mrow><mml:mi mathvariant="italic">ρ</mml:mi><mml:msub><mml:mi>c</mml:mi><mml:mi>P</mml:mi></mml:msub></mml:mrow><mml:mi mathvariant="italic">γ</mml:mi></mml:mfrac></mml:mstyle><mml:mspace linebreak="nobreak" width="0.125em"/><mml:mstyle displaystyle="false"><mml:mfrac style="text"><mml:mrow><mml:msub><mml:mi>g</mml:mi><mml:mtext>A</mml:mtext></mml:msub><mml:msub><mml:mi>g</mml:mi><mml:mtext>C</mml:mtext></mml:msub></mml:mrow><mml:mrow><mml:msub><mml:mi>g</mml:mi><mml:mtext>A</mml:mtext></mml:msub><mml:mo>+</mml:mo><mml:msub><mml:mi>g</mml:mi><mml:mtext>C</mml:mtext></mml:msub></mml:mrow></mml:mfrac></mml:mstyle><mml:mo>(</mml:mo><mml:msubsup><mml:mi>e</mml:mi><mml:mn mathvariant="normal">0</mml:mn><mml:mo>*</mml:mo></mml:msubsup></mml:mrow></mml:math></inline-formula> <inline-formula><mml:math display="inline"><mml:mo>-</mml:mo></mml:math></inline-formula> <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>e</mml:mi><mml:mtext>A</mml:mtext></mml:msub><mml:mo>)</mml:mo></mml:mrow></mml:math></inline-formula>]
as follows.

                <disp-formula specific-use="align" content-type="numbered"><mml:math display="block"><mml:mtable displaystyle="true"><mml:mlabeledtr id="App1.Ch1.E12"><mml:mtd/><mml:mtd><mml:mrow><mml:mi mathvariant="normal">Λ</mml:mi></mml:mrow></mml:mtd><mml:mtd><mml:mrow><mml:mo>=</mml:mo><mml:mstyle displaystyle="true"><mml:mfrac style="display"><mml:mrow><mml:mi mathvariant="italic">λ</mml:mi><mml:mi>E</mml:mi></mml:mrow><mml:mrow><mml:mi>H</mml:mi><mml:mo>+</mml:mo><mml:mi mathvariant="italic">λ</mml:mi><mml:mi>E</mml:mi></mml:mrow></mml:mfrac></mml:mstyle></mml:mrow></mml:mtd></mml:mlabeledtr><mml:mlabeledtr id="App1.Ch1.E13"><mml:mtd/><mml:mtd/><mml:mtd><mml:mrow><mml:mo>=</mml:mo><mml:mstyle displaystyle="true"><mml:mfrac style="display"><mml:mrow><mml:mstyle displaystyle="false"><mml:mfrac style="text"><mml:mrow><mml:mi mathvariant="italic">ρ</mml:mi><mml:msub><mml:mi>c</mml:mi><mml:mi>P</mml:mi></mml:msub></mml:mrow><mml:mi mathvariant="italic">γ</mml:mi></mml:mfrac></mml:mstyle><mml:mstyle displaystyle="false"><mml:mfrac style="text"><mml:mrow><mml:msub><mml:mi>g</mml:mi><mml:mtext>A</mml:mtext></mml:msub><mml:msub><mml:mi>g</mml:mi><mml:mtext>C</mml:mtext></mml:msub></mml:mrow><mml:mrow><mml:msub><mml:mi>g</mml:mi><mml:mtext>A</mml:mtext></mml:msub><mml:mo>+</mml:mo><mml:msub><mml:mi>g</mml:mi><mml:mtext>C</mml:mtext></mml:msub></mml:mrow></mml:mfrac></mml:mstyle><mml:mfenced close=")" open="("><mml:msubsup><mml:mi>e</mml:mi><mml:mn mathvariant="normal">0</mml:mn><mml:mo>*</mml:mo></mml:msubsup><mml:mo>-</mml:mo><mml:msub><mml:mi>e</mml:mi><mml:mtext>A</mml:mtext></mml:msub></mml:mfenced></mml:mrow><mml:mrow><mml:mi mathvariant="italic">ρ</mml:mi><mml:msub><mml:mi>c</mml:mi><mml:mi>P</mml:mi></mml:msub><mml:msub><mml:mi>g</mml:mi><mml:mtext>A</mml:mtext></mml:msub><mml:mfenced open="(" close=")"><mml:msub><mml:mi>T</mml:mi><mml:mn mathvariant="normal">0</mml:mn></mml:msub><mml:mo>-</mml:mo><mml:msub><mml:mi>T</mml:mi><mml:mtext>A</mml:mtext></mml:msub></mml:mfenced><mml:mo>+</mml:mo><mml:mstyle displaystyle="false"><mml:mfrac style="text"><mml:mrow><mml:mi mathvariant="italic">ρ</mml:mi><mml:msub><mml:mi>c</mml:mi><mml:mi>P</mml:mi></mml:msub></mml:mrow><mml:mi mathvariant="italic">γ</mml:mi></mml:mfrac></mml:mstyle><mml:mstyle displaystyle="false"><mml:mfrac style="text"><mml:mrow><mml:msub><mml:mi>g</mml:mi><mml:mtext>A</mml:mtext></mml:msub><mml:msub><mml:mi>g</mml:mi><mml:mtext>C</mml:mtext></mml:msub></mml:mrow><mml:mrow><mml:msub><mml:mi>g</mml:mi><mml:mtext>A</mml:mtext></mml:msub><mml:mo>+</mml:mo><mml:msub><mml:mi>g</mml:mi><mml:mtext>C</mml:mtext></mml:msub></mml:mrow></mml:mfrac></mml:mstyle><mml:mfenced open="(" close=")"><mml:msubsup><mml:mi>e</mml:mi><mml:mn mathvariant="normal">0</mml:mn><mml:mo>*</mml:mo></mml:msubsup><mml:mo>-</mml:mo><mml:msub><mml:mi>e</mml:mi><mml:mtext>A</mml:mtext></mml:msub></mml:mfenced></mml:mrow></mml:mfrac></mml:mstyle></mml:mrow></mml:mtd></mml:mlabeledtr><mml:mlabeledtr id="App1.Ch1.E14"><mml:mtd/><mml:mtd/><mml:mtd><mml:mrow><mml:mo>=</mml:mo><mml:mstyle displaystyle="true"><mml:mfrac style="display"><mml:mrow><mml:msub><mml:mi>g</mml:mi><mml:mtext>C</mml:mtext></mml:msub><mml:mfenced close=")" open="("><mml:msubsup><mml:mi>e</mml:mi><mml:mn mathvariant="normal">0</mml:mn><mml:mo>*</mml:mo></mml:msubsup><mml:mo>-</mml:mo><mml:msub><mml:mi>e</mml:mi><mml:mtext>A</mml:mtext></mml:msub></mml:mfenced></mml:mrow><mml:mrow><mml:mfenced open="[" close="]"><mml:mi mathvariant="italic">γ</mml:mi><mml:mfenced close=")" open="("><mml:msub><mml:mi>T</mml:mi><mml:mn mathvariant="normal">0</mml:mn></mml:msub><mml:mo>-</mml:mo><mml:msub><mml:mi>T</mml:mi><mml:mtext>A</mml:mtext></mml:msub></mml:mfenced><mml:mfenced open="(" close=")"><mml:msub><mml:mi>g</mml:mi><mml:mtext>A</mml:mtext></mml:msub><mml:mo>+</mml:mo><mml:msub><mml:mi>g</mml:mi><mml:mtext>C</mml:mtext></mml:msub></mml:mfenced><mml:mo>+</mml:mo><mml:msub><mml:mi>g</mml:mi><mml:mtext>C</mml:mtext></mml:msub><mml:mfenced open="(" close=")"><mml:msubsup><mml:mi>e</mml:mi><mml:mn mathvariant="normal">0</mml:mn><mml:mo>*</mml:mo></mml:msubsup><mml:mo>-</mml:mo><mml:msub><mml:mi>e</mml:mi><mml:mtext>A</mml:mtext></mml:msub></mml:mfenced></mml:mfenced></mml:mrow></mml:mfrac></mml:mstyle></mml:mrow></mml:mtd></mml:mlabeledtr></mml:mtable></mml:math></disp-formula></p>
      <p>Combining Eqs. (A14) and (A8) (eliminating <inline-formula><mml:math display="inline"><mml:mi mathvariant="normal">Λ</mml:mi></mml:math></inline-formula>), we can derive a physical
equation of <inline-formula><mml:math display="inline"><mml:mi mathvariant="italic">α</mml:mi></mml:math></inline-formula>.

                <disp-formula id="App1.Ch1.E15" content-type="numbered"><mml:math display="block"><mml:mrow><mml:mi mathvariant="italic">α</mml:mi><mml:mo>=</mml:mo><mml:mstyle displaystyle="true"><mml:mfrac style="display"><mml:mrow><mml:msub><mml:mi>g</mml:mi><mml:mtext>C</mml:mtext></mml:msub><mml:mfenced open="(" close=")"><mml:msubsup><mml:mi>e</mml:mi><mml:mn mathvariant="normal">0</mml:mn><mml:mo>*</mml:mo></mml:msubsup><mml:mo>-</mml:mo><mml:msub><mml:mi>e</mml:mi><mml:mtext>A</mml:mtext></mml:msub></mml:mfenced><mml:mfenced open="[" close="]"><mml:mn mathvariant="normal">2</mml:mn><mml:mi>s</mml:mi><mml:mo>+</mml:mo><mml:mn mathvariant="normal">2</mml:mn><mml:mi mathvariant="italic">γ</mml:mi><mml:mo>+</mml:mo><mml:mi mathvariant="italic">γ</mml:mi><mml:mstyle displaystyle="false"><mml:mfrac style="text"><mml:mrow><mml:msub><mml:mi>g</mml:mi><mml:mtext>A</mml:mtext></mml:msub></mml:mrow><mml:mrow><mml:msub><mml:mi>g</mml:mi><mml:mtext>C</mml:mtext></mml:msub></mml:mrow></mml:mfrac></mml:mstyle><mml:mo>(</mml:mo><mml:mn mathvariant="normal">1</mml:mn><mml:mo>+</mml:mo><mml:mi>M</mml:mi><mml:mo>)</mml:mo></mml:mfenced></mml:mrow><mml:mrow><mml:mn mathvariant="normal">2</mml:mn><mml:mi>s</mml:mi><mml:mfenced open="[" close="]"><mml:mi mathvariant="italic">γ</mml:mi><mml:mfenced close=")" open="("><mml:msub><mml:mi>T</mml:mi><mml:mn mathvariant="normal">0</mml:mn></mml:msub><mml:mo>-</mml:mo><mml:msub><mml:mi>T</mml:mi><mml:mtext>A</mml:mtext></mml:msub></mml:mfenced><mml:mfenced open="(" close=")"><mml:msub><mml:mi>g</mml:mi><mml:mtext>A</mml:mtext></mml:msub><mml:mo>+</mml:mo><mml:msub><mml:mi>g</mml:mi><mml:mtext>C</mml:mtext></mml:msub></mml:mfenced><mml:mo>+</mml:mo><mml:msub><mml:mi>g</mml:mi><mml:mtext>C</mml:mtext></mml:msub><mml:mfenced open="(" close=")"><mml:msubsup><mml:mi>e</mml:mi><mml:mn mathvariant="normal">0</mml:mn><mml:mo>*</mml:mo></mml:msubsup><mml:mo>-</mml:mo><mml:msub><mml:mi>e</mml:mi><mml:mtext>A</mml:mtext></mml:msub></mml:mfenced></mml:mfenced></mml:mrow></mml:mfrac></mml:mstyle></mml:mrow></mml:math></disp-formula></p>
      <p>Following Venturini et al. (2008), <inline-formula><mml:math display="inline"><mml:mi>M</mml:mi></mml:math></inline-formula> can be expressed as the ratio of the
vapor pressure difference to the vapor press deficit between the surface and
atmosphere as follows.

                <disp-formula id="App1.Ch1.E16" content-type="numbered"><mml:math display="block"><mml:mrow><mml:mi>M</mml:mi><mml:mo>=</mml:mo><mml:mstyle displaystyle="true"><mml:mfrac style="display"><mml:mrow><mml:mfenced open="(" close=")"><mml:msub><mml:mi>e</mml:mi><mml:mn mathvariant="normal">0</mml:mn></mml:msub><mml:mo>-</mml:mo><mml:msub><mml:mi>e</mml:mi><mml:mtext>A</mml:mtext></mml:msub></mml:mfenced></mml:mrow><mml:mrow><mml:mfenced close=")" open="("><mml:msubsup><mml:mi>e</mml:mi><mml:mn mathvariant="normal">0</mml:mn><mml:mo>*</mml:mo></mml:msubsup><mml:mo>-</mml:mo><mml:msub><mml:mi>e</mml:mi><mml:mtext>A</mml:mtext></mml:msub></mml:mfenced></mml:mrow></mml:mfrac></mml:mstyle><mml:mo>=</mml:mo><mml:mstyle displaystyle="true"><mml:mfrac style="display"><mml:mrow><mml:mfenced close=")" open="("><mml:msub><mml:mi>e</mml:mi><mml:mn mathvariant="normal">0</mml:mn></mml:msub><mml:mo>-</mml:mo><mml:msub><mml:mi>e</mml:mi><mml:mtext>A</mml:mtext></mml:msub></mml:mfenced></mml:mrow><mml:mrow><mml:mi>k</mml:mi><mml:mfenced open="(" close=")"><mml:msubsup><mml:mi>e</mml:mi><mml:mtext>S</mml:mtext><mml:mo>*</mml:mo></mml:msubsup><mml:mo>-</mml:mo><mml:msub><mml:mi>e</mml:mi><mml:mtext>A</mml:mtext></mml:msub></mml:mfenced></mml:mrow></mml:mfrac></mml:mstyle><mml:mo>=</mml:mo><mml:mstyle displaystyle="true"><mml:mfrac style="display"><mml:mrow><mml:msub><mml:mi>s</mml:mi><mml:mn mathvariant="normal">1</mml:mn></mml:msub><mml:mfenced close=")" open="("><mml:msub><mml:mi>T</mml:mi><mml:mtext>SD</mml:mtext></mml:msub><mml:mo>-</mml:mo><mml:msub><mml:mi>T</mml:mi><mml:mtext>D</mml:mtext></mml:msub></mml:mfenced></mml:mrow><mml:mrow><mml:mi>k</mml:mi><mml:msub><mml:mi>s</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub><mml:mfenced open="(" close=")"><mml:msub><mml:mi>T</mml:mi><mml:mtext>R</mml:mtext></mml:msub><mml:mo>-</mml:mo><mml:msub><mml:mi>T</mml:mi><mml:mtext>D</mml:mtext></mml:msub></mml:mfenced></mml:mrow></mml:mfrac></mml:mstyle><mml:mo>,</mml:mo></mml:mrow></mml:math></disp-formula>

          where <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>T</mml:mi><mml:mtext>SD</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> is the dew-point temperature at source/sink height and
<inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>T</mml:mi><mml:mtext>D</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> is the air dew-point temperature; <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>s</mml:mi><mml:mn mathvariant="normal">1</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> and <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>s</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> are the
psychrometric slopes of the saturation vapor pressure and temperature between
the (<inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>T</mml:mi><mml:mtext>SD</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> <inline-formula><mml:math display="inline"><mml:mo>-</mml:mo></mml:math></inline-formula> <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>T</mml:mi><mml:mtext>D</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula>) vs. (<inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>e</mml:mi><mml:mn mathvariant="normal">0</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> <inline-formula><mml:math display="inline"><mml:mo>-</mml:mo></mml:math></inline-formula> <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>e</mml:mi><mml:mtext>A</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula>) and
(<inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>T</mml:mi><mml:mtext>R</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> <inline-formula><mml:math display="inline"><mml:mo>-</mml:mo></mml:math></inline-formula> <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>T</mml:mi><mml:mtext>D</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula>) vs. (<inline-formula><mml:math display="inline"><mml:mrow><mml:msubsup><mml:mi>e</mml:mi><mml:mtext>S</mml:mtext><mml:mo>*</mml:mo></mml:msubsup></mml:mrow></mml:math></inline-formula> <inline-formula><mml:math display="inline"><mml:mo>-</mml:mo></mml:math></inline-formula> <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>e</mml:mi><mml:mtext>A</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula>)
relationship (Venturini et al., 2008), and <inline-formula><mml:math display="inline"><mml:mi>k</mml:mi></mml:math></inline-formula> is the ratio between
(<inline-formula><mml:math display="inline"><mml:mrow><mml:msubsup><mml:mi>e</mml:mi><mml:mn mathvariant="normal">0</mml:mn><mml:mo>*</mml:mo></mml:msubsup></mml:mrow></mml:math></inline-formula> <inline-formula><mml:math display="inline"><mml:mo>-</mml:mo></mml:math></inline-formula> <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>e</mml:mi><mml:mtext>A</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula>) and (<inline-formula><mml:math display="inline"><mml:mrow><mml:msubsup><mml:mi>e</mml:mi><mml:mtext>S</mml:mtext><mml:mo>*</mml:mo></mml:msubsup></mml:mrow></mml:math></inline-formula> <inline-formula><mml:math display="inline"><mml:mo>-</mml:mo></mml:math></inline-formula> <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>e</mml:mi><mml:mtext>A</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula>).
Despite <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>T</mml:mi><mml:mn mathvariant="normal">0</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> driving the sensible heat flux, the comprehensive dry–wet
signature of the underlying surface due to soil moisture variations is
directly reflected in <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>T</mml:mi><mml:mtext>R</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> (Kustas and Anderson, 2009). Therefore,
using <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>T</mml:mi><mml:mtext>R</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> in the denominator of Eq. (A16) tends to give a direct
signature of the surface moisture availability (<inline-formula><mml:math display="inline"><mml:mi>M</mml:mi></mml:math></inline-formula>). In Eq. (A16),
<inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>T</mml:mi><mml:mtext>SD</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> computation is challenging because both <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>e</mml:mi><mml:mn mathvariant="normal">0</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> and <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>s</mml:mi><mml:mn mathvariant="normal">1</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> are
unknown. By decomposing the aerodynamic equation of <inline-formula><mml:math display="inline"><mml:mrow><mml:mi mathvariant="italic">λ</mml:mi><mml:mi>E</mml:mi></mml:mrow></mml:math></inline-formula>,
<inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>T</mml:mi><mml:mtext>SD</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> can be expressed as follows.

                <disp-formula specific-use="align" content-type="numbered"><mml:math display="block"><mml:mtable displaystyle="true"><mml:mlabeledtr id="App1.Ch1.E17"><mml:mtd/><mml:mtd/><mml:mtd><mml:mrow><mml:mi mathvariant="italic">λ</mml:mi><mml:mi>E</mml:mi><mml:mo>=</mml:mo><mml:mstyle displaystyle="true"><mml:mfrac style="display"><mml:mrow><mml:mi mathvariant="italic">ρ</mml:mi><mml:msub><mml:mi>c</mml:mi><mml:mi>P</mml:mi></mml:msub></mml:mrow><mml:mi mathvariant="italic">γ</mml:mi></mml:mfrac></mml:mstyle><mml:msub><mml:mi>g</mml:mi><mml:mtext>A</mml:mtext></mml:msub><mml:mfenced close=")" open="("><mml:msub><mml:mi>e</mml:mi><mml:mn mathvariant="normal">0</mml:mn></mml:msub><mml:mo>-</mml:mo><mml:msub><mml:mi>e</mml:mi><mml:mtext>A</mml:mtext></mml:msub></mml:mfenced><mml:mo>=</mml:mo><mml:mstyle displaystyle="true"><mml:mfrac style="display"><mml:mrow><mml:mi mathvariant="italic">ρ</mml:mi><mml:msub><mml:mi>c</mml:mi><mml:mi>P</mml:mi></mml:msub></mml:mrow><mml:mi mathvariant="italic">γ</mml:mi></mml:mfrac></mml:mstyle><mml:msub><mml:mi>g</mml:mi><mml:mtext>A</mml:mtext></mml:msub><mml:msub><mml:mi>s</mml:mi><mml:mn mathvariant="normal">1</mml:mn></mml:msub><mml:mfenced close=")" open="("><mml:msub><mml:mi>T</mml:mi><mml:mtext>SD</mml:mtext></mml:msub><mml:mo>-</mml:mo><mml:msub><mml:mi>T</mml:mi><mml:mtext>D</mml:mtext></mml:msub></mml:mfenced></mml:mrow></mml:mtd></mml:mlabeledtr><mml:mlabeledtr id="App1.Ch1.E18"><mml:mtd/><mml:mtd/><mml:mtd><mml:mrow><mml:msub><mml:mi>T</mml:mi><mml:mtext>SD</mml:mtext></mml:msub><mml:mo>=</mml:mo><mml:msub><mml:mi>T</mml:mi><mml:mtext>D</mml:mtext></mml:msub><mml:mo>+</mml:mo><mml:mstyle displaystyle="true"><mml:mfrac style="display"><mml:mrow><mml:mi mathvariant="italic">γ</mml:mi><mml:mi mathvariant="italic">λ</mml:mi><mml:mi>E</mml:mi></mml:mrow><mml:mrow><mml:mi mathvariant="italic">ρ</mml:mi><mml:msub><mml:mi>c</mml:mi><mml:mi>P</mml:mi></mml:msub><mml:msub><mml:mi>g</mml:mi><mml:mtext>A</mml:mtext></mml:msub><mml:msub><mml:mi>s</mml:mi><mml:mn mathvariant="normal">1</mml:mn></mml:msub></mml:mrow></mml:mfrac></mml:mstyle></mml:mrow></mml:mtd></mml:mlabeledtr></mml:mtable></mml:math></disp-formula></p>
      <p>In the earlier STIC versions, <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>s</mml:mi><mml:mn mathvariant="normal">1</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> was approximated at <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>T</mml:mi><mml:mtext>D</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula>,
<inline-formula><mml:math display="inline"><mml:mrow><mml:msubsup><mml:mi>e</mml:mi><mml:mn mathvariant="normal">0</mml:mn><mml:mo>*</mml:mo></mml:msubsup></mml:mrow></mml:math></inline-formula> was approximated at <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>T</mml:mi><mml:mtext>R</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula>, <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>T</mml:mi><mml:mtext>SD</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> was estimated
from <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>s</mml:mi><mml:mn mathvariant="normal">1</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula>, <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>T</mml:mi><mml:mtext>D</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula>, <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>T</mml:mi><mml:mtext>R</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula>, and related saturation vapor
pressures (Mallick et al., 2014, 2015), and <inline-formula><mml:math display="inline"><mml:mi>M</mml:mi></mml:math></inline-formula> was estimated from Eq. (A16)
(estimation of <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>T</mml:mi><mml:mtext>SD</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> and <inline-formula><mml:math display="inline"><mml:mi>M</mml:mi></mml:math></inline-formula> was stand-alone earlier). However, since
<inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>T</mml:mi><mml:mtext>SD</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> depends on <inline-formula><mml:math display="inline"><mml:mrow><mml:mi mathvariant="italic">λ</mml:mi><mml:mi>E</mml:mi></mml:mrow></mml:math></inline-formula> and <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>g</mml:mi><mml:mtext>A</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula>, an iterative
procedure is applied to estimate <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>T</mml:mi><mml:mtext>SD</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> and <inline-formula><mml:math display="inline"><mml:mi>M</mml:mi></mml:math></inline-formula> as described in the
following paragraph.</p>

      <?xmltex \floatpos{t}?><fig id="App1.Ch1.F3"><caption><p><bold>(a)</bold> Convergence of the iteration method for retrieving the
source/sink height (or in-canopy) vapor pressures (<inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>e</mml:mi><mml:mn mathvariant="normal">0</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> and <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>D</mml:mi><mml:mn mathvariant="normal">0</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula>) and
Priestley–Taylor coefficient (<inline-formula><mml:math display="inline"><mml:mi mathvariant="italic">α</mml:mi></mml:math></inline-formula>). <bold>(b)</bold> Convergence of the
iteration method for retrieving the surface wetness (<inline-formula><mml:math display="inline"><mml:mi>M</mml:mi></mml:math></inline-formula>) and source/sink
height dew-point temperature (<inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>T</mml:mi><mml:mtext>SD</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula>). The initial values of
<inline-formula><mml:math display="inline"><mml:mrow><mml:mi mathvariant="italic">λ</mml:mi><mml:mi>E</mml:mi><mml:mo>,</mml:mo><mml:msub><mml:mi>g</mml:mi><mml:mtext>A</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula>, <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>g</mml:mi><mml:mtext>C</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula>, and <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>T</mml:mi><mml:mn mathvariant="normal">0</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> were determined with
<inline-formula><mml:math display="inline"><mml:mi mathvariant="italic">α</mml:mi></mml:math></inline-formula> <inline-formula><mml:math display="inline"><mml:mo>=</mml:mo></mml:math></inline-formula> 1.26. The process is then iterated by updating <inline-formula><mml:math display="inline"><mml:mrow><mml:mi mathvariant="italic">λ</mml:mi><mml:mi>E</mml:mi></mml:mrow></mml:math></inline-formula>,
<inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>e</mml:mi><mml:mn mathvariant="normal">0</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula>, <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>D</mml:mi><mml:mn mathvariant="normal">0</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula>, <inline-formula><mml:math display="inline"><mml:mi>M</mml:mi></mml:math></inline-formula>, <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>T</mml:mi><mml:mtext>SD</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula>, and <inline-formula><mml:math display="inline"><mml:mi mathvariant="italic">α</mml:mi></mml:math></inline-formula> in subsequent iterations
with the previous estimates of <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>g</mml:mi><mml:mtext>A</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula>, <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>g</mml:mi><mml:mtext>C</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula>, and <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>T</mml:mi><mml:mn mathvariant="normal">0</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula>.</p></caption>
          <?xmltex \igopts{width=199.169291pt}?><graphic xlink:href="https://hess.copernicus.org/articles/20/4237/2016/hess-20-4237-2016-f12.pdf"/>

        </fig>

      <p><?xmltex \hack{\newpage}?>In STIC1.2, an initial value of <inline-formula><mml:math display="inline"><mml:mi mathvariant="italic">α</mml:mi></mml:math></inline-formula> is assigned as 1.26 and initial
estimates of <inline-formula><mml:math display="inline"><mml:mrow><mml:msubsup><mml:mi>e</mml:mi><mml:mn mathvariant="normal">0</mml:mn><mml:mo>*</mml:mo></mml:msubsup></mml:mrow></mml:math></inline-formula> and <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>e</mml:mi><mml:mn mathvariant="normal">0</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> are obtained from <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>T</mml:mi><mml:mtext>R</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> and <inline-formula><mml:math display="inline"><mml:mi>M</mml:mi></mml:math></inline-formula>
as
<inline-formula><mml:math display="inline"><mml:mrow><mml:msubsup><mml:mi>e</mml:mi><mml:mn mathvariant="normal">0</mml:mn><mml:mo>*</mml:mo></mml:msubsup></mml:mrow></mml:math></inline-formula> <inline-formula><mml:math display="inline"><mml:mo>=</mml:mo></mml:math></inline-formula> 6.13753<inline-formula><mml:math display="inline"><mml:mrow><mml:msup><mml:mi>e</mml:mi><mml:mfrac><mml:mrow><mml:mn>17.27</mml:mn><mml:msub><mml:mi>T</mml:mi><mml:mtext>R</mml:mtext></mml:msub></mml:mrow><mml:mrow><mml:mfenced open="(" close=")"><mml:msub><mml:mi>T</mml:mi><mml:mtext>R</mml:mtext></mml:msub><mml:mo>+</mml:mo><mml:mn>237.3</mml:mn></mml:mfenced></mml:mrow></mml:mfrac></mml:msup></mml:mrow></mml:math></inline-formula>
and <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>e</mml:mi><mml:mn mathvariant="normal">0</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> <inline-formula><mml:math display="inline"><mml:mo>=</mml:mo></mml:math></inline-formula> <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>e</mml:mi><mml:mtext>A</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> <inline-formula><mml:math display="inline"><mml:mo>+</mml:mo></mml:math></inline-formula> <inline-formula><mml:math display="inline"><mml:mrow><mml:mi>M</mml:mi><mml:mo>(</mml:mo><mml:msubsup><mml:mi>e</mml:mi><mml:mn mathvariant="normal">0</mml:mn><mml:mo>*</mml:mo></mml:msubsup></mml:mrow></mml:math></inline-formula> <inline-formula><mml:math display="inline"><mml:mo>-</mml:mo></mml:math></inline-formula> <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>e</mml:mi><mml:mtext>A</mml:mtext></mml:msub><mml:mo>)</mml:mo></mml:mrow></mml:math></inline-formula>.
Initial <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>T</mml:mi><mml:mtext>SD</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> and <inline-formula><mml:math display="inline"><mml:mi>M</mml:mi></mml:math></inline-formula> were estimated as described in Mallick et
al. (2014, 2015). With the initial estimates of these variables, first
estimates of the conductances, <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>T</mml:mi><mml:mn mathvariant="normal">0</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula>, <inline-formula><mml:math display="inline"><mml:mi mathvariant="normal">Λ</mml:mi></mml:math></inline-formula>, and <inline-formula><mml:math display="inline"><mml:mrow><mml:mi mathvariant="italic">λ</mml:mi><mml:mi>E</mml:mi></mml:mrow></mml:math></inline-formula> are
obtained. The process is then iterated by updating <inline-formula><mml:math display="inline"><mml:mrow><mml:msubsup><mml:mi>e</mml:mi><mml:mn mathvariant="normal">0</mml:mn><mml:mo>*</mml:mo></mml:msubsup></mml:mrow></mml:math></inline-formula> (using
Eq. A9), <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>D</mml:mi><mml:mn mathvariant="normal">0</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> (using Eq. A10), <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>e</mml:mi><mml:mn mathvariant="normal">0</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> (using Eq. A11), <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>T</mml:mi><mml:mtext>SD</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula>
(using Eq. A17 with <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>s</mml:mi><mml:mn mathvariant="normal">1</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> estimated at <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>T</mml:mi><mml:mtext>D</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula>), <inline-formula><mml:math display="inline"><mml:mi>M</mml:mi></mml:math></inline-formula> (using Eq. A16),
and <inline-formula><mml:math display="inline"><mml:mi mathvariant="italic">α</mml:mi></mml:math></inline-formula> (using Eq. A15), with the first estimates of <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>g</mml:mi><mml:mtext>C</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula>,
<inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>g</mml:mi><mml:mtext>A</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula>, and <inline-formula><mml:math display="inline"><mml:mrow><mml:mi mathvariant="italic">λ</mml:mi><mml:mi>E</mml:mi></mml:mrow></mml:math></inline-formula>, and recomputing <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>g</mml:mi><mml:mtext>C</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula>, <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>g</mml:mi><mml:mtext>A</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula>,
<inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>T</mml:mi><mml:mn mathvariant="normal">0</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula>, <inline-formula><mml:math display="inline"><mml:mi mathvariant="normal">Λ</mml:mi></mml:math></inline-formula>, and <inline-formula><mml:math display="inline"><mml:mrow><mml:mi mathvariant="italic">λ</mml:mi><mml:mi>E</mml:mi></mml:mrow></mml:math></inline-formula> in the subsequent iterations with the
previous estimates of <inline-formula><mml:math display="inline"><mml:mrow><mml:msubsup><mml:mi>e</mml:mi><mml:mn mathvariant="normal">0</mml:mn><mml:mo>*</mml:mo></mml:msubsup></mml:mrow></mml:math></inline-formula>, <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>e</mml:mi><mml:mn mathvariant="normal">0</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula>, <inline-formula><mml:math display="inline"><mml:mi>M</mml:mi></mml:math></inline-formula>, and <inline-formula><mml:math display="inline"><mml:mi mathvariant="italic">α</mml:mi></mml:math></inline-formula> until the
convergence of <inline-formula><mml:math display="inline"><mml:mrow><mml:mi mathvariant="italic">λ</mml:mi><mml:mi>E</mml:mi></mml:mrow></mml:math></inline-formula> is achieved. Stable values of <inline-formula><mml:math display="inline"><mml:mrow><mml:mi mathvariant="italic">λ</mml:mi><mml:mi>E</mml:mi></mml:mrow></mml:math></inline-formula>,
<inline-formula><mml:math display="inline"><mml:mrow><mml:msubsup><mml:mi>e</mml:mi><mml:mn mathvariant="normal">0</mml:mn><mml:mo>*</mml:mo></mml:msubsup></mml:mrow></mml:math></inline-formula>, <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>e</mml:mi><mml:mn mathvariant="normal">0</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula>, <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>T</mml:mi><mml:mtext>SD</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula>, <inline-formula><mml:math display="inline"><mml:mi>M</mml:mi></mml:math></inline-formula>, and <inline-formula><mml:math display="inline"><mml:mi mathvariant="italic">α</mml:mi></mml:math></inline-formula> are obtained within
<inline-formula><mml:math display="inline"><mml:mo>∼</mml:mo></mml:math></inline-formula> 25 iterations. Illustrative examples of the convergence of
<inline-formula><mml:math display="inline"><mml:mrow><mml:msubsup><mml:mi>e</mml:mi><mml:mn mathvariant="normal">0</mml:mn><mml:mo>*</mml:mo></mml:msubsup></mml:mrow></mml:math></inline-formula>, <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>e</mml:mi><mml:mn mathvariant="normal">0</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula>, <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>T</mml:mi><mml:mtext>SD</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula>, <inline-formula><mml:math display="inline"><mml:mi>M</mml:mi></mml:math></inline-formula>, and <inline-formula><mml:math display="inline"><mml:mi mathvariant="italic">α</mml:mi></mml:math></inline-formula> are shown in Fig. A3.</p>
      <p>To summarize, the computational steps of the conductances and evaporative
fluxes in STIC are
<list list-type="bullet"><list-item>
      <p>Step 1: analytical solution of the conductances, <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>T</mml:mi><mml:mn mathvariant="normal">0</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> and <inline-formula><mml:math display="inline"><mml:mi mathvariant="normal">Λ</mml:mi></mml:math></inline-formula>,
by solving the “state equations” (Eqs. 2–5);</p></list-item><list-item>
      <p>Step 2: initial estimates of the conductances (<inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>g</mml:mi><mml:mtext>C</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> and <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>g</mml:mi><mml:mtext>A</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula>),
<inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>T</mml:mi><mml:mn mathvariant="normal">0</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula>, <inline-formula><mml:math display="inline"><mml:mi mathvariant="normal">Λ</mml:mi></mml:math></inline-formula>, <inline-formula><mml:math display="inline"><mml:mrow><mml:mi mathvariant="italic">λ</mml:mi><mml:mi>E</mml:mi></mml:mrow></mml:math></inline-formula>, and <inline-formula><mml:math display="inline"><mml:mi>H</mml:mi></mml:math></inline-formula>;</p></list-item><list-item>
      <p>Step 3: simultaneous iteration of <inline-formula><mml:math display="inline"><mml:mrow><mml:mi mathvariant="italic">λ</mml:mi><mml:mi>E</mml:mi></mml:mrow></mml:math></inline-formula>, <inline-formula><mml:math display="inline"><mml:mrow><mml:msubsup><mml:mi>e</mml:mi><mml:mn mathvariant="normal">0</mml:mn><mml:mo>*</mml:mo></mml:msubsup></mml:mrow></mml:math></inline-formula>, <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>e</mml:mi><mml:mn mathvariant="normal">0</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula>,
<inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>T</mml:mi><mml:mtext>SD</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula>, <inline-formula><mml:math display="inline"><mml:mi>M</mml:mi></mml:math></inline-formula>, and <inline-formula><mml:math display="inline"><mml:mi mathvariant="italic">α</mml:mi></mml:math></inline-formula>, and final estimation of the conductances
(<inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>g</mml:mi><mml:mtext>C</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> and <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>g</mml:mi><mml:mtext>A</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula>), <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>T</mml:mi><mml:mn mathvariant="normal">0</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula>, <inline-formula><mml:math display="inline"><mml:mi mathvariant="normal">Λ</mml:mi></mml:math></inline-formula>, <inline-formula><mml:math display="inline"><mml:mrow><mml:mi mathvariant="italic">λ</mml:mi><mml:mi>E</mml:mi></mml:mrow></mml:math></inline-formula>, and <inline-formula><mml:math display="inline"><mml:mi>H</mml:mi></mml:math></inline-formula>;
and</p></list-item><list-item>
      <p>Step 4: partitioning <inline-formula><mml:math display="inline"><mml:mrow><mml:mi mathvariant="italic">λ</mml:mi><mml:mi>E</mml:mi></mml:mrow></mml:math></inline-formula> into <inline-formula><mml:math display="inline"><mml:mrow><mml:mi mathvariant="italic">λ</mml:mi><mml:msub><mml:mi>E</mml:mi><mml:mtext>T</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> and <inline-formula><mml:math display="inline"><mml:mrow><mml:mi mathvariant="italic">λ</mml:mi><mml:msub><mml:mi>E</mml:mi><mml:mtext>E</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula>.</p></list-item></list></p><?xmltex \hack{\clearpage}?><?xmltex \floatpos{h!}?><table-wrap id="App1.Ch1.T1"><?xmltex \hack{\hsize\textwidth}?><caption><p>Differences in the modeling philosophies of
source/sink height vapor pressures (<inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>e</mml:mi><mml:mn mathvariant="normal">0</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula>, <inline-formula><mml:math display="inline"><mml:mrow><mml:msubsup><mml:mi>e</mml:mi><mml:mn mathvariant="normal">0</mml:mn><mml:mo>*</mml:mo></mml:msubsup></mml:mrow></mml:math></inline-formula>) and dew-point
temperature (<inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>T</mml:mi><mml:mtext>SD</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula>), surface wetness (<inline-formula><mml:math display="inline"><mml:mi>M</mml:mi></mml:math></inline-formula>), and <inline-formula><mml:math display="inline"><mml:mi mathvariant="italic">α</mml:mi></mml:math></inline-formula> between
STIC1.0, STIC1.1, and STIC1.2.</p></caption><oasis:table frame="topbot"><oasis:tgroup cols="4">
     <oasis:colspec colnum="1" colname="col1" align="left"/>
     <oasis:colspec colnum="2" colname="col2" align="left"/>
     <oasis:colspec colnum="3" colname="col3" align="left"/>
     <oasis:colspec colnum="4" colname="col4" align="left"/>
     <oasis:thead>
       <oasis:row>  
         <oasis:entry colname="col1">Variable</oasis:entry>  
         <oasis:entry rowsep="1" namest="col2" nameend="col4" align="center">Principles </oasis:entry>
       </oasis:row>
       <oasis:row>  
         <oasis:entry colname="col1">estimation</oasis:entry>  
         <oasis:entry colname="col2">STIC1.0</oasis:entry>  
         <oasis:entry colname="col3">STIC1.1</oasis:entry>  
         <oasis:entry colname="col4">STIC1.2</oasis:entry>
       </oasis:row>
       <oasis:row rowsep="1">  
         <oasis:entry colname="col1"/>  
         <oasis:entry colname="col2">(Mallick et al., 2014)</oasis:entry>  
         <oasis:entry colname="col3">(Mallick et al., 2015)</oasis:entry>  
         <oasis:entry colname="col4">(this study – Mallick et al., 2016)</oasis:entry>
       </oasis:row>
     </oasis:thead>
     <oasis:tbody>
       <oasis:row>  
         <oasis:entry colname="col1">Saturation</oasis:entry>  
         <oasis:entry colname="col2"><inline-formula><mml:math display="inline"><mml:mrow><mml:msubsup><mml:mi>e</mml:mi><mml:mn mathvariant="normal">0</mml:mn><mml:mo>*</mml:mo></mml:msubsup></mml:mrow></mml:math></inline-formula> was approximated as the</oasis:entry>  
         <oasis:entry colname="col3">Same as STIC1.0</oasis:entry>  
         <oasis:entry colname="col4"><inline-formula><mml:math display="inline"><mml:mrow><mml:msubsup><mml:mi>e</mml:mi><mml:mn mathvariant="normal">0</mml:mn><mml:mo>*</mml:mo></mml:msubsup></mml:mrow></mml:math></inline-formula> is estimated through numerical</oasis:entry>
       </oasis:row>
       <oasis:row>  
         <oasis:entry colname="col1">vapor</oasis:entry>  
         <oasis:entry colname="col2">saturation vapor pressure at</oasis:entry>  
         <oasis:entry colname="col3"/>  
         <oasis:entry colname="col4">iteration by inverting the aerodynamic</oasis:entry>
       </oasis:row>
       <oasis:row>  
         <oasis:entry colname="col1">pressure at</oasis:entry>  
         <oasis:entry colname="col2"><inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>T</mml:mi><mml:mtext>R</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula>.</oasis:entry>  
         <oasis:entry colname="col3"/>  
         <oasis:entry colname="col4">equation of <inline-formula><mml:math display="inline"><mml:mrow><mml:mi mathvariant="italic">λ</mml:mi><mml:mi>E</mml:mi></mml:mrow></mml:math></inline-formula> (as described in Appendix A2).</oasis:entry>
       </oasis:row>
       <oasis:row>  
         <oasis:entry colname="col1">source/sink</oasis:entry>  
         <oasis:entry colname="col2"/>  
         <oasis:entry colname="col3"/>  
         <oasis:entry colname="col4"><inline-formula><mml:math display="inline"><mml:mrow><mml:msubsup><mml:mi>e</mml:mi><mml:mn mathvariant="normal">0</mml:mn><mml:mo>*</mml:mo></mml:msubsup></mml:mrow></mml:math></inline-formula> <inline-formula><mml:math display="inline"><mml:mo>=</mml:mo></mml:math></inline-formula> <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>e</mml:mi><mml:mtext>A</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> <inline-formula><mml:math display="inline"><mml:mo>+</mml:mo></mml:math></inline-formula> <inline-formula><mml:math display="inline"><mml:mrow><mml:mfenced open="[" close="]"><mml:mstyle displaystyle="false"><mml:mfrac style="text"><mml:mrow><mml:mi mathvariant="italic">γ</mml:mi><mml:mi mathvariant="italic">λ</mml:mi><mml:mi>E</mml:mi><mml:mfenced open="(" close=")"><mml:msub><mml:mi>g</mml:mi><mml:mtext>A</mml:mtext></mml:msub><mml:mo>+</mml:mo><mml:msub><mml:mi>g</mml:mi><mml:mtext>C</mml:mtext></mml:msub></mml:mfenced></mml:mrow><mml:mrow><mml:mi mathvariant="italic">ρ</mml:mi><mml:msub><mml:mi>c</mml:mi><mml:mi>P</mml:mi></mml:msub><mml:msub><mml:mi>g</mml:mi><mml:mtext>A</mml:mtext></mml:msub><mml:msub><mml:mi>g</mml:mi><mml:mtext>C</mml:mtext></mml:msub></mml:mrow></mml:mfrac></mml:mstyle></mml:mfenced></mml:mrow></mml:math></inline-formula></oasis:entry>
       </oasis:row>
       <oasis:row rowsep="1">  
         <oasis:entry colname="col1">height (<inline-formula><mml:math display="inline"><mml:mrow><mml:msubsup><mml:mi>e</mml:mi><mml:mn mathvariant="normal">0</mml:mn><mml:mo>*</mml:mo></mml:msubsup></mml:mrow></mml:math></inline-formula>)</oasis:entry>  
         <oasis:entry colname="col2"/>  
         <oasis:entry colname="col3"/>  
         <oasis:entry colname="col4"/>
       </oasis:row>
       <oasis:row>  
         <oasis:entry colname="col1">Actual vapor</oasis:entry>  
         <oasis:entry colname="col2"><inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>e</mml:mi><mml:mn mathvariant="normal">0</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> was empirically estimated</oasis:entry>  
         <oasis:entry colname="col3">Same as STIC1.0</oasis:entry>  
         <oasis:entry colname="col4"><inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>e</mml:mi><mml:mn mathvariant="normal">0</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> is estimated as <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>e</mml:mi><mml:mn mathvariant="normal">0</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> <inline-formula><mml:math display="inline"><mml:mo>=</mml:mo></mml:math></inline-formula> <inline-formula><mml:math display="inline"><mml:mrow><mml:msubsup><mml:mi>e</mml:mi><mml:mn mathvariant="normal">0</mml:mn><mml:mo>*</mml:mo></mml:msubsup></mml:mrow></mml:math></inline-formula> <inline-formula><mml:math display="inline"><mml:mo>-</mml:mo></mml:math></inline-formula> <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>D</mml:mi><mml:mn mathvariant="normal">0</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula>, where <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>D</mml:mi><mml:mn mathvariant="normal">0</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula></oasis:entry>
       </oasis:row>
       <oasis:row>  
         <oasis:entry colname="col1">pressure at</oasis:entry>  
         <oasis:entry colname="col2">from <inline-formula><mml:math display="inline"><mml:mi>M</mml:mi></mml:math></inline-formula> based on the</oasis:entry>  
         <oasis:entry colname="col3"/>  
         <oasis:entry colname="col4">was iteratively estimated by combining</oasis:entry>
       </oasis:row>
       <oasis:row>  
         <oasis:entry colname="col1">source/sink</oasis:entry>  
         <oasis:entry colname="col2">assumption that the vapor</oasis:entry>  
         <oasis:entry colname="col3"/>  
         <oasis:entry colname="col4">PM with the Shuttleworth–Wallace</oasis:entry>
       </oasis:row>
       <oasis:row>  
         <oasis:entry colname="col1">height (<inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>e</mml:mi><mml:mn mathvariant="normal">0</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula>)</oasis:entry>  
         <oasis:entry colname="col2">pressure at the source/sink</oasis:entry>  
         <oasis:entry colname="col3"/>  
         <oasis:entry colname="col4">approximation (as described in Appendix A2).</oasis:entry>
       </oasis:row>
       <oasis:row>  
         <oasis:entry colname="col1"/>  
         <oasis:entry colname="col2">height ranges between</oasis:entry>  
         <oasis:entry colname="col3"/>  
         <oasis:entry colname="col4"><inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>D</mml:mi><mml:mn mathvariant="normal">0</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> <inline-formula><mml:math display="inline"><mml:mo>=</mml:mo></mml:math></inline-formula> <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>D</mml:mi><mml:mtext>A</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> <inline-formula><mml:math display="inline"><mml:mo>+</mml:mo></mml:math></inline-formula> <inline-formula><mml:math display="inline"><mml:mrow><mml:mfenced close="]" open="["><mml:mstyle displaystyle="false"><mml:mfrac style="text"><mml:mrow><mml:mo mathvariant="italic">{</mml:mo><mml:mi>s</mml:mi><mml:mi mathvariant="italic">ϕ</mml:mi><mml:mo>-</mml:mo><mml:mo>(</mml:mo><mml:mi>s</mml:mi><mml:mo>+</mml:mo><mml:mi mathvariant="italic">γ</mml:mi><mml:mo>)</mml:mo><mml:mi mathvariant="italic">λ</mml:mi><mml:mi>E</mml:mi><mml:mo mathvariant="italic">}</mml:mo></mml:mrow><mml:mrow><mml:mi mathvariant="italic">ρ</mml:mi><mml:msub><mml:mi>c</mml:mi><mml:mi>P</mml:mi></mml:msub><mml:msub><mml:mi>g</mml:mi><mml:mtext>A</mml:mtext></mml:msub></mml:mrow></mml:mfrac></mml:mstyle></mml:mfenced></mml:mrow></mml:math></inline-formula></oasis:entry>
       </oasis:row>
       <oasis:row>  
         <oasis:entry colname="col1"/>  
         <oasis:entry colname="col2">extreme wet–dry surface</oasis:entry>  
         <oasis:entry colname="col3"/>  
         <oasis:entry colname="col4"/>
       </oasis:row>
       <oasis:row rowsep="1">  
         <oasis:entry colname="col1"/>  
         <oasis:entry colname="col2">conditions.</oasis:entry>  
         <oasis:entry colname="col3"/>  
         <oasis:entry colname="col4"/>
       </oasis:row>
       <oasis:row>  
         <oasis:entry colname="col1">Dew-point</oasis:entry>  
         <oasis:entry colname="col2"><inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>T</mml:mi><mml:mtext>SD</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> <inline-formula><mml:math display="inline"><mml:mo>=</mml:mo></mml:math></inline-formula> <inline-formula><mml:math display="inline"><mml:mstyle displaystyle="false"><mml:mfrac style="text"><mml:mrow><mml:mfenced open="(" close=")"><mml:msubsup><mml:mi>e</mml:mi><mml:mtext>S</mml:mtext><mml:mo>*</mml:mo></mml:msubsup><mml:mo>-</mml:mo><mml:msub><mml:mi>e</mml:mi><mml:mtext>A</mml:mtext></mml:msub></mml:mfenced><mml:mo>-</mml:mo><mml:msub><mml:mi>s</mml:mi><mml:mn mathvariant="normal">3</mml:mn></mml:msub><mml:msub><mml:mi>T</mml:mi><mml:mtext>R</mml:mtext></mml:msub><mml:mo>+</mml:mo><mml:msub><mml:mi>s</mml:mi><mml:mn mathvariant="normal">1</mml:mn></mml:msub><mml:msub><mml:mi>T</mml:mi><mml:mtext>D</mml:mtext></mml:msub></mml:mrow><mml:mrow><mml:mfenced open="(" close=")"><mml:msub><mml:mi>s</mml:mi><mml:mn mathvariant="normal">1</mml:mn></mml:msub><mml:mo>-</mml:mo><mml:msub><mml:mi>s</mml:mi><mml:mn mathvariant="normal">3</mml:mn></mml:msub></mml:mfenced></mml:mrow></mml:mfrac></mml:mstyle></mml:math></inline-formula></oasis:entry>  
         <oasis:entry colname="col3">Same as STIC1.0</oasis:entry>  
         <oasis:entry colname="col4"><inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>T</mml:mi><mml:mtext>SD</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> is estimated through numerical</oasis:entry>
       </oasis:row>
       <oasis:row>  
         <oasis:entry colname="col1">temperature at</oasis:entry>  
         <oasis:entry colname="col2"><inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>s</mml:mi><mml:mn mathvariant="normal">1</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> and <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>s</mml:mi><mml:mn mathvariant="normal">3</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> are the slopes of</oasis:entry>  
         <oasis:entry colname="col3"/>  
         <oasis:entry colname="col4">iteration by inverting the aerodynamic</oasis:entry>
       </oasis:row>
       <oasis:row>  
         <oasis:entry colname="col1">source/sink</oasis:entry>  
         <oasis:entry colname="col2">saturation vapor pressures at</oasis:entry>  
         <oasis:entry colname="col3"/>  
         <oasis:entry colname="col4">equation of <inline-formula><mml:math display="inline"><mml:mrow><mml:mi mathvariant="italic">λ</mml:mi><mml:mi>E</mml:mi></mml:mrow></mml:math></inline-formula> (as described in Appendix A2).</oasis:entry>
       </oasis:row>
       <oasis:row>  
         <oasis:entry colname="col1">height (<inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>T</mml:mi><mml:mtext>SD</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula>)</oasis:entry>  
         <oasis:entry colname="col2">temperatures, approximated at</oasis:entry>  
         <oasis:entry colname="col3"/>  
         <oasis:entry colname="col4"><inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>T</mml:mi><mml:mtext>SD</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> <inline-formula><mml:math display="inline"><mml:mo>=</mml:mo></mml:math></inline-formula> <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>T</mml:mi><mml:mtext>D</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> <inline-formula><mml:math display="inline"><mml:mo>+</mml:mo></mml:math></inline-formula> <inline-formula><mml:math display="inline"><mml:mstyle displaystyle="false"><mml:mfrac style="text"><mml:mrow><mml:mi mathvariant="italic">γ</mml:mi><mml:mi mathvariant="italic">λ</mml:mi><mml:mi>E</mml:mi></mml:mrow><mml:mrow><mml:mi mathvariant="italic">ρ</mml:mi><mml:msub><mml:mi>c</mml:mi><mml:mi>P</mml:mi></mml:msub><mml:msub><mml:mi>g</mml:mi><mml:mtext>A</mml:mtext></mml:msub><mml:msub><mml:mi>s</mml:mi><mml:mn mathvariant="normal">1</mml:mn></mml:msub></mml:mrow></mml:mfrac></mml:mstyle></mml:math></inline-formula></oasis:entry>
       </oasis:row>
       <oasis:row rowsep="1">  
         <oasis:entry colname="col1"/>  
         <oasis:entry colname="col2"><inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>T</mml:mi><mml:mtext>D</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> and <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>T</mml:mi><mml:mtext>R</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula>, respectively.</oasis:entry>  
         <oasis:entry colname="col3"/>  
         <oasis:entry colname="col4"/>
       </oasis:row>
       <oasis:row>  
         <oasis:entry colname="col1">Surface</oasis:entry>  
         <oasis:entry colname="col2">As a stand-alone equation,</oasis:entry>  
         <oasis:entry colname="col3">Same as STIC1.0</oasis:entry>  
         <oasis:entry colname="col4">A feedback of <inline-formula><mml:math display="inline"><mml:mi>M</mml:mi></mml:math></inline-formula> into <inline-formula><mml:math display="inline"><mml:mrow><mml:mi mathvariant="italic">λ</mml:mi><mml:mi>E</mml:mi></mml:mrow></mml:math></inline-formula> is introduced</oasis:entry>
       </oasis:row>
       <oasis:row>  
         <oasis:entry colname="col1">moisture</oasis:entry>  
         <oasis:entry colname="col2">without any feedback to <inline-formula><mml:math display="inline"><mml:mrow><mml:mi mathvariant="italic">λ</mml:mi><mml:mi>E</mml:mi></mml:mrow></mml:math></inline-formula>.</oasis:entry>  
         <oasis:entry colname="col3"/>  
         <oasis:entry colname="col4">and <inline-formula><mml:math display="inline"><mml:mi>M</mml:mi></mml:math></inline-formula> is iteratively estimated after</oasis:entry>
       </oasis:row>
       <oasis:row>  
         <oasis:entry colname="col1">availability</oasis:entry>  
         <oasis:entry colname="col2"/>  
         <oasis:entry colname="col3"/>  
         <oasis:entry colname="col4">estimating <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>T</mml:mi><mml:mtext>SD</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> (as described in Appendix A2).</oasis:entry>
       </oasis:row>
       <oasis:row rowsep="1">  
         <oasis:entry colname="col1">(<inline-formula><mml:math display="inline"><mml:mi>M</mml:mi></mml:math></inline-formula>)</oasis:entry>  
         <oasis:entry colname="col2"/>  
         <oasis:entry colname="col3"/>  
         <oasis:entry colname="col4"/>
       </oasis:row>
       <oasis:row>  
         <oasis:entry colname="col1">Priestley–</oasis:entry>  
         <oasis:entry colname="col2">As fixed parameter (1.26).</oasis:entry>  
         <oasis:entry colname="col3">A physical equation</oasis:entry>  
         <oasis:entry colname="col4">A physical equation of <inline-formula><mml:math display="inline"><mml:mi mathvariant="italic">α</mml:mi></mml:math></inline-formula> is derived as a</oasis:entry>
       </oasis:row>
       <oasis:row>  
         <oasis:entry colname="col1">Taylor</oasis:entry>  
         <oasis:entry colname="col2"/>  
         <oasis:entry colname="col3">of <inline-formula><mml:math display="inline"><mml:mi mathvariant="italic">α</mml:mi></mml:math></inline-formula> is derived as a</oasis:entry>  
         <oasis:entry colname="col4">function of the conductances and <inline-formula><mml:math display="inline"><mml:mi mathvariant="italic">α</mml:mi></mml:math></inline-formula> is</oasis:entry>
       </oasis:row>
       <oasis:row>  
         <oasis:entry colname="col1">parameter (<inline-formula><mml:math display="inline"><mml:mi mathvariant="italic">α</mml:mi></mml:math></inline-formula>)</oasis:entry>  
         <oasis:entry colname="col2"/>  
         <oasis:entry colname="col3">function of the</oasis:entry>  
         <oasis:entry colname="col4">numerically estimated as a variable</oasis:entry>
       </oasis:row>
       <oasis:row>  
         <oasis:entry colname="col1"/>  
         <oasis:entry colname="col2"/>  
         <oasis:entry colname="col3">conductances and <inline-formula><mml:math display="inline"><mml:mi mathvariant="italic">α</mml:mi></mml:math></inline-formula></oasis:entry>  
         <oasis:entry colname="col4">(Eq. A15) (as described in Appendix A2).</oasis:entry>
       </oasis:row>
       <oasis:row>  
         <oasis:entry colname="col1"/>  
         <oasis:entry colname="col2"/>  
         <oasis:entry colname="col3">is numerically</oasis:entry>  
         <oasis:entry colname="col4"/>
       </oasis:row>
       <oasis:row>  
         <oasis:entry colname="col1"/>  
         <oasis:entry colname="col2"/>  
         <oasis:entry colname="col3">estimated as a</oasis:entry>  
         <oasis:entry colname="col4"/>
       </oasis:row>
       <oasis:row>  
         <oasis:entry colname="col1"/>  
         <oasis:entry colname="col2"/>  
         <oasis:entry colname="col3">variable.</oasis:entry>  
         <oasis:entry colname="col4"/>
       </oasis:row>
     </oasis:tbody>
   </oasis:tgroup></oasis:table></table-wrap>

<?xmltex \hack{\clearpage}?><?xmltex \floatpos{h!}?><table-wrap id="App1.Ch1.T2"><?xmltex \hack{\hsize\textwidth}?><caption><p>Fundamental differences in the modeling
principles between STIC1.2 and previous approaches for characterizing the
biophysical controls on <inline-formula><mml:math display="inline"><mml:mrow><mml:mi mathvariant="italic">λ</mml:mi><mml:mi>E</mml:mi></mml:mrow></mml:math></inline-formula> components.</p></caption><oasis:table frame="topbot"><oasis:tgroup cols="3">
     <oasis:colspec colnum="1" colname="col1" align="left"/>
     <oasis:colspec colnum="2" colname="col2" align="left"/>
     <oasis:colspec colnum="3" colname="col3" align="left"/>
     <oasis:thead>
       <oasis:row>  
         <oasis:entry colname="col1">Biophysical</oasis:entry>  
         <oasis:entry rowsep="1" namest="col2" nameend="col3" align="center">Modeling principles </oasis:entry>
       </oasis:row>
       <oasis:row>  
         <oasis:entry colname="col1">states</oasis:entry>  
         <oasis:entry colname="col2">Parametric modeling</oasis:entry>  
         <oasis:entry colname="col3">STIC1.2</oasis:entry>
       </oasis:row>
       <oasis:row>  
         <oasis:entry colname="col1"/>  
         <oasis:entry colname="col2">(Ma et al., 2015; Chen et al., 2011;</oasis:entry>  
         <oasis:entry colname="col3"/>
       </oasis:row>
       <oasis:row rowsep="1">  
         <oasis:entry colname="col1"/>  
         <oasis:entry colname="col2">Kumagai et al., 2004)</oasis:entry>  
         <oasis:entry colname="col3"/>
       </oasis:row>
     </oasis:thead>
     <oasis:tbody>
       <oasis:row>  
         <oasis:entry colname="col1"><inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>g</mml:mi><mml:mtext>A</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula></oasis:entry>  
         <oasis:entry colname="col2">Either <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>g</mml:mi><mml:mtext>A</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> is assumed to be the momentum</oasis:entry>  
         <oasis:entry colname="col3">Analytically retrieved by solving “<inline-formula><mml:math display="inline"><mml:mi>n</mml:mi></mml:math></inline-formula>” state</oasis:entry>
       </oasis:row>
       <oasis:row>  
         <oasis:entry colname="col1"/>  
         <oasis:entry colname="col2">conductance (<inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>g</mml:mi><mml:mtext>M</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula>) or estimated as a sum of <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>g</mml:mi><mml:mtext>M</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> and</oasis:entry>  
         <oasis:entry colname="col3">equations and “<inline-formula><mml:math display="inline"><mml:mi>n</mml:mi></mml:math></inline-formula>” unknowns, with explicit</oasis:entry>
       </oasis:row>
       <oasis:row>  
         <oasis:entry colname="col1"/>  
         <oasis:entry colname="col2">quasi-laminar boundary-layer conductance (<inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>g</mml:mi><mml:mtext>B</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula>).</oasis:entry>  
         <oasis:entry colname="col3">convective feedback and without any wind</oasis:entry>
       </oasis:row>
       <oasis:row>  
         <oasis:entry colname="col1"/>  
         <oasis:entry colname="col2"/>  
         <oasis:entry colname="col3">speed (<inline-formula><mml:math display="inline"><mml:mi>u</mml:mi></mml:math></inline-formula>) information.</oasis:entry>
       </oasis:row>
       <oasis:row>  
         <oasis:entry colname="col1"/>  
         <oasis:entry colname="col2">1/<inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>g</mml:mi><mml:mtext>A</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> <inline-formula><mml:math display="inline"><mml:mo>=</mml:mo></mml:math></inline-formula> 1/<inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>g</mml:mi><mml:mtext>M</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> <inline-formula><mml:math display="inline"><mml:mo>+</mml:mo></mml:math></inline-formula> 1/<inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>g</mml:mi><mml:mtext>B</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula></oasis:entry>  
         <oasis:entry colname="col3">In a hallmark paper by Choudhury and</oasis:entry>
       </oasis:row>
       <oasis:row>  
         <oasis:entry colname="col1"/>  
         <oasis:entry colname="col2"><inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>g</mml:mi><mml:mtext>M</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> <inline-formula><mml:math display="inline"><mml:mo>=</mml:mo></mml:math></inline-formula> <inline-formula><mml:math display="inline"><mml:mrow><mml:mo>(</mml:mo><mml:msup><mml:mi>u</mml:mi><mml:mo>*</mml:mo></mml:msup><mml:msup><mml:mo>)</mml:mo><mml:mn mathvariant="normal">2</mml:mn></mml:msup><mml:mo>/</mml:mo><mml:mi>u</mml:mi></mml:mrow></mml:math></inline-formula></oasis:entry>  
         <oasis:entry colname="col3">Monteith (1986), it is clearly stated that</oasis:entry>
       </oasis:row>
       <oasis:row>  
         <oasis:entry colname="col1"/>  
         <oasis:entry colname="col2"><inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>g</mml:mi><mml:mtext>B</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> <inline-formula><mml:math display="inline"><mml:mo>=</mml:mo></mml:math></inline-formula> <inline-formula><mml:math display="inline"><mml:mi>f</mml:mi></mml:math></inline-formula> <inline-formula><mml:math display="inline"><mml:mo mathvariant="italic">{</mml:mo></mml:math></inline-formula>Nusselt number, leaf dimension, thermal</oasis:entry>  
         <oasis:entry colname="col3">“aerodynamic conductance determined by wind</oasis:entry>
       </oasis:row>
       <oasis:row>  
         <oasis:entry colname="col1"/>  
         <oasis:entry colname="col2">conductivity of air in the boundary layer, <inline-formula><mml:math display="inline"><mml:mi>u</mml:mi></mml:math></inline-formula>, kinematic</oasis:entry>  
         <oasis:entry colname="col3">speed and roughness is assumed to be</oasis:entry>
       </oasis:row>
       <oasis:row>  
         <oasis:entry colname="col1"/>  
         <oasis:entry colname="col2">viscosity, Reynolds number<inline-formula><mml:math display="inline"><mml:mo mathvariant="italic">}</mml:mo></mml:math></inline-formula></oasis:entry>  
         <oasis:entry colname="col3">unaffected by buoyancy. Strictly, the</oasis:entry>
       </oasis:row>
       <oasis:row>  
         <oasis:entry colname="col1"/>  
         <oasis:entry colname="col2"/>  
         <oasis:entry colname="col3">aerodynamic conductance should be replaced</oasis:entry>
       </oasis:row>
       <oasis:row>  
         <oasis:entry colname="col1"/>  
         <oasis:entry colname="col2">If <inline-formula><mml:math display="inline"><mml:mrow><mml:msup><mml:mi>u</mml:mi><mml:mo>*</mml:mo></mml:msup></mml:mrow></mml:math></inline-formula> is available from EC tower, it is directly</oasis:entry>  
         <oasis:entry colname="col3">by a term that accounts for radiative as well</oasis:entry>
       </oasis:row>
       <oasis:row>  
         <oasis:entry colname="col1"/>  
         <oasis:entry colname="col2">used, otherwise <inline-formula><mml:math display="inline"><mml:mrow><mml:msup><mml:mi>u</mml:mi><mml:mo>*</mml:mo></mml:msup></mml:mrow></mml:math></inline-formula> is parametrized using Monin–</oasis:entry>  
         <oasis:entry colname="col3">as convective heat transfer”. The role of <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>g</mml:mi><mml:mtext>A</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> is</oasis:entry>
       </oasis:row>
       <oasis:row>  
         <oasis:entry colname="col1"/>  
         <oasis:entry colname="col2">Obukhov Similarity Theory (MOST).</oasis:entry>  
         <oasis:entry colname="col3">associated with the role of convection</oasis:entry>
       </oasis:row>
       <oasis:row>  
         <oasis:entry colname="col1"/>  
         <oasis:entry colname="col2"/>  
         <oasis:entry colname="col3">(Choudhury and Monteith, 1986) according to</oasis:entry>
       </oasis:row>
       <oasis:row>  
         <oasis:entry colname="col1"/>  
         <oasis:entry colname="col2">Disadvantages: (1) MOST is only valid for an</oasis:entry>  
         <oasis:entry colname="col3">the surface energy balance principle as</oasis:entry>
       </oasis:row>
       <oasis:row>  
         <oasis:entry colname="col1"/>  
         <oasis:entry colname="col2">extended, uniform, and flat surface (Foken,</oasis:entry>  
         <oasis:entry colname="col3">reflected in the derivation of Eq. (A4). Wind</oasis:entry>
       </oasis:row>
       <oasis:row>  
         <oasis:entry colname="col1"/>  
         <oasis:entry colname="col2">2006). MOST tends to fail over rough surfaces</oasis:entry>  
         <oasis:entry colname="col3">is generated as a result of the differences in</oasis:entry>
       </oasis:row>
       <oasis:row>  
         <oasis:entry colname="col1"/>  
         <oasis:entry colname="col2">due to breakdown of the similarity relationships</oasis:entry>  
         <oasis:entry colname="col3">atmospheric pressure that is a result of</oasis:entry>
       </oasis:row>
       <oasis:row>  
         <oasis:entry colname="col1"/>  
         <oasis:entry colname="col2">for heat and water vapor transfer in the roughness</oasis:entry>  
         <oasis:entry colname="col3">uneven surface radiative heating. Therefore,</oasis:entry>
       </oasis:row>
       <oasis:row>  
         <oasis:entry colname="col1"/>  
         <oasis:entry colname="col2">sub-layer, which results in an underestimation of</oasis:entry>  
         <oasis:entry colname="col3">the aerodynamic conductance (and wind as</oasis:entry>
       </oasis:row>
       <oasis:row>  
         <oasis:entry colname="col1"/>  
         <oasis:entry colname="col2">the “true” <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>g</mml:mi><mml:mtext>A</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> by a factor of 1–3 (Thom et al., 1975;</oasis:entry>  
         <oasis:entry colname="col3">well) is an effect of net radiative heating and</oasis:entry>
       </oasis:row>
       <oasis:row>  
         <oasis:entry colname="col1"/>  
         <oasis:entry colname="col2">Chen and Schwerdtfeger, 1989; Simpson et al.,</oasis:entry>  
         <oasis:entry colname="col3">there should be a physical relationship between</oasis:entry>
       </oasis:row>
       <oasis:row>  
         <oasis:entry colname="col1"/>  
         <oasis:entry colname="col2">1998; Holwerda et al., 2012). (2) In the state-of-the-</oasis:entry>  
         <oasis:entry colname="col3">these two.</oasis:entry>
       </oasis:row>
       <oasis:row>  
         <oasis:entry colname="col1"/>  
         <oasis:entry colname="col2">art <inline-formula><mml:math display="inline"><mml:mrow><mml:mi mathvariant="italic">λ</mml:mi><mml:mi>E</mml:mi></mml:mrow></mml:math></inline-formula> modeling, the parametric <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>g</mml:mi><mml:mtext>A</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> sub-models</oasis:entry>  
         <oasis:entry colname="col3"/>
       </oasis:row>
       <oasis:row>  
         <oasis:entry colname="col1"/>  
         <oasis:entry colname="col2">are stand-alone and empirical, and do not provide</oasis:entry>  
         <oasis:entry colname="col3">Advantages: (1) STIC1.2 consists of a</oasis:entry>
       </oasis:row>
       <oasis:row>  
         <oasis:entry colname="col1"/>  
         <oasis:entry colname="col2">any feedback to <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>g</mml:mi><mml:mtext>C</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula>, aerodynamic temperature</oasis:entry>  
         <oasis:entry colname="col3">feedback describing the relationship between</oasis:entry>
       </oasis:row>
       <oasis:row>  
         <oasis:entry colname="col1"/>  
         <oasis:entry colname="col2">(<inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>T</mml:mi><mml:mn mathvariant="normal">0</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula>), and aerodynamic vapor pressures (<inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>e</mml:mi><mml:mn mathvariant="normal">0</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> and</oasis:entry>  
         <oasis:entry colname="col3"><inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>T</mml:mi><mml:mtext>R</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> and <inline-formula><mml:math display="inline"><mml:mrow><mml:mi mathvariant="italic">λ</mml:mi><mml:mi>E</mml:mi></mml:mrow></mml:math></inline-formula>, coupled with canopy–atmosphere</oasis:entry>
       </oasis:row>
       <oasis:row>  
         <oasis:entry colname="col1"/>  
         <oasis:entry colname="col2"><inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>D</mml:mi><mml:mn mathvariant="normal">0</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula>). (3) Additional challenges in grid-scale or</oasis:entry>  
         <oasis:entry colname="col3">components relating <inline-formula><mml:math display="inline"><mml:mrow><mml:mi mathvariant="italic">λ</mml:mi><mml:mi>E</mml:mi></mml:mrow></mml:math></inline-formula> to <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>T</mml:mi><mml:mn mathvariant="normal">0</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> and <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>e</mml:mi><mml:mn mathvariant="normal">0</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula>.</oasis:entry>
       </oasis:row>
       <oasis:row>  
         <oasis:entry colname="col1"/>  
         <oasis:entry colname="col2">spatial-scale <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>g</mml:mi><mml:mtext>A</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> estimation are the requirements</oasis:entry>  
         <oasis:entry colname="col3">(2) Supports the findings of Villani et al. (2003)</oasis:entry>
       </oasis:row>
       <oasis:row>  
         <oasis:entry colname="col1"/>  
         <oasis:entry colname="col2">of numerous site-specific parameters (e.g.,</oasis:entry>  
         <oasis:entry colname="col3">which stated that during unstable surface-layer</oasis:entry>
       </oasis:row>
       <oasis:row>  
         <oasis:entry colname="col1"/>  
         <oasis:entry colname="col2">vegetation height, measurement height,</oasis:entry>  
         <oasis:entry colname="col3">conditions the major source of net available</oasis:entry>
       </oasis:row>
       <oasis:row>  
         <oasis:entry colname="col1"/>  
         <oasis:entry colname="col2">vegetation roughness, leaf size, soil roughness),</oasis:entry>  
         <oasis:entry colname="col3">energy is located at the canopy top and drives</oasis:entry>
       </oasis:row>
       <oasis:row>  
         <oasis:entry colname="col1"/>  
         <oasis:entry colname="col2">and coefficients needed to correct the</oasis:entry>  
         <oasis:entry colname="col3">the convective motion in the layers above.</oasis:entry>
       </oasis:row>
       <oasis:row>  
         <oasis:entry colname="col1"/>  
         <oasis:entry colname="col2">atmospheric stability conditions (Raupach,</oasis:entry>  
         <oasis:entry colname="col3"/>
       </oasis:row>
       <oasis:row rowsep="1">  
         <oasis:entry colname="col1"/>  
         <oasis:entry colname="col2">1998).</oasis:entry>  
         <oasis:entry colname="col3"/>
       </oasis:row>
       <oasis:row>  
         <oasis:entry colname="col1"><inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>g</mml:mi><mml:mtext>C</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula></oasis:entry>  
         <oasis:entry colname="col2">(a) If <inline-formula><mml:math display="inline"><mml:mrow><mml:mi mathvariant="italic">λ</mml:mi><mml:mi>E</mml:mi></mml:mrow></mml:math></inline-formula> measurements are available from the EC</oasis:entry>  
         <oasis:entry colname="col3">Analytically retrieved by solving “<inline-formula><mml:math display="inline"><mml:mi>n</mml:mi></mml:math></inline-formula>” state</oasis:entry>
       </oasis:row>
       <oasis:row>  
         <oasis:entry colname="col1"/>  
         <oasis:entry colname="col2">towers, <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>g</mml:mi><mml:mtext>C</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> is estimated by inverting the PM</oasis:entry>  
         <oasis:entry colname="col3">equations and “<inline-formula><mml:math display="inline"><mml:mi>n</mml:mi></mml:math></inline-formula>” unknowns where physical</oasis:entry>
       </oasis:row>
       <oasis:row>  
         <oasis:entry colname="col1"/>  
         <oasis:entry colname="col2">equation. None of these approaches allow</oasis:entry>  
         <oasis:entry colname="col3">feedbacks of <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>g</mml:mi><mml:mtext>A</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula>, soil moisture, and vapor</oasis:entry>
       </oasis:row>
       <oasis:row>  
         <oasis:entry colname="col1"/>  
         <oasis:entry colname="col2">independent quantification of biophysical</oasis:entry>  
         <oasis:entry colname="col3">pressure deficit are embedded (as explained in</oasis:entry>
       </oasis:row>
       <oasis:row>  
         <oasis:entry colname="col1"/>  
         <oasis:entry colname="col2">controls of <inline-formula><mml:math display="inline"><mml:mrow><mml:mi mathvariant="italic">λ</mml:mi><mml:mi>E</mml:mi></mml:mrow></mml:math></inline-formula> as <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>g</mml:mi><mml:mtext>C</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> is constrained by <inline-formula><mml:math display="inline"><mml:mrow><mml:mi mathvariant="italic">λ</mml:mi><mml:mi>E</mml:mi></mml:mrow></mml:math></inline-formula> itself.</oasis:entry>  
         <oasis:entry colname="col3">STIC1.2 equations in the Appendix).</oasis:entry>
       </oasis:row>
       <oasis:row>  
         <oasis:entry colname="col1"/>  
         <oasis:entry colname="col2">(b) Sometimes <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>g</mml:mi><mml:mtext>C</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> is modeled either by coupled</oasis:entry>  
         <oasis:entry colname="col3"/>
       </oasis:row>
       <oasis:row>  
         <oasis:entry colname="col1"/>  
         <oasis:entry colname="col2">leaf-scale photosynthesis models (Ball et al.,</oasis:entry>  
         <oasis:entry colname="col3"/>
       </oasis:row>
       <oasis:row>  
         <oasis:entry colname="col1"/>  
         <oasis:entry colname="col2">1987; Leuning, 1995) or <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>g</mml:mi><mml:mtext>C</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> is estimated from</oasis:entry>  
         <oasis:entry colname="col3"/>
       </oasis:row>
       <oasis:row>  
         <oasis:entry colname="col1"/>  
         <oasis:entry colname="col2">stand-alone empirical models (Jarvis, 1976)</oasis:entry>  
         <oasis:entry colname="col3"/>
       </oasis:row>
     </oasis:tbody>
   </oasis:tgroup></oasis:table></table-wrap>

<?xmltex \hack{\clearpage}?><supplementary-material position="anchor"><p><bold>The Supplement related to this article is available online at <inline-supplementary-material xlink:href="http://dx.doi.org/10.5194/hess-20-4237-2016-supplement" xlink:title="pdf">doi:10.5194/hess-20-4237-2016-supplement</inline-supplementary-material>.</bold><?xmltex \hack{\vspace*{-6mm}}?></p></supplementary-material>
</sec>
</app>
  </app-group><ack><title>Acknowledgements</title><p>This study was funded by the Luxembourg Institute of Science and Technology
(LIST). The developed modeling framework contributes to the Catchments As
Organized Systems (CAOS) Phase-2 research group (FOR 1598) funded by the
German Science Foundation (DFG) and to the HiWET (High-resolution modelling
and monitoring of Water and Energy Transfers in wetland ecosystems)
consortium funded by BELSPO and FNR. We sincerely thank Andrew Jarvis
(Lancaster University, UK), Monica Garcia (Technical University of Denmark,
Denmark), and Georg Wohlfahrt (University of Innsbruck, Austria) for very
helpful discussions and edits of the manuscript. We are grateful to all
Brazilian and international collaborators and all the funding agencies that
have contributed to the Large-scale Biosphere Atmosphere Experiment in
Amazônia (LBA). The authors are indebted to Pavel Kabat,
Antônio Ocimar Manzi, David R. Fitzjarrald, Julio Tota,
Humberto Ribeiro da Rocha, Michael Goulden, Maarten J. Waterloo, and
Luiz Martinelli for planning, coordinating, conducting, and evaluating the
eddy covariance, meteorological, and leaf–gas exchange measurements at the
LBA sites. We are particularly grateful to all field technicians whose hard
work was the key ingredient to establishing the quality of the datasets used
in this paper. The authors declare no conflict of interest. Darren T. Drewry
acknowledges the support of the Jet Propulsion Laboratory, California
Institute of Technology, under a contract with the National Aeronautics and
Space Administration. <?xmltex \hack{\newline}?><?xmltex \hack{\newline}?> Edited by: P. Saco
<?xmltex \hack{\newline}?> Reviewed by: four anonymous referees</p></ack><ref-list>
    <title>References</title>

      <ref id="bib1.bib1"><label>1</label><mixed-citation>Anderson, M. C., Norman, J. M., Kustas, W. P., Li, F., Prueger, J. H., and
Mecikalski, J. R.: A climatological study of evapotranspiration and moisture
stress across the continental United States: 1. Model formulation,
J. Geophys. Res., 112, D11112, <ext-link xlink:href="http://dx.doi.org/10.1029/2006JD007507" ext-link-type="DOI">10.1029/2006JD007507</ext-link>, 2007.</mixed-citation></ref>
      <ref id="bib1.bib2"><label>2</label><mixed-citation>Andreae, M. O., Artaxo, P., Brandao, C., Carswell, F. E., Ciccioli, P.,
da Costa, A. L., Culf, A. D., Esteves, J. L., Gash, J. H. C., Grace, J.,
Kabat, P., Lelieveld, J., Malhi, Y., Manzi, A. O., Meixner, F. X., Nobre,
A. D., Nobre, C., Ruivo, M. d. L. P., Silva-Dias, M. A., Stefani, P.,
Valentini, R., von Jouanne, J., and Waterloo, M. J.: Biogeochemical cycling
of carbon, water, energy, trace gases, and aerosols in Amazonia: The
LBA-EUSTACH experiments, J. Geophys. Res., 107, D208066,
<ext-link xlink:href="http://dx.doi.org/10.1029/2001JD000524" ext-link-type="DOI">10.1029/2001JD000524</ext-link>, 2002.</mixed-citation></ref>
      <ref id="bib1.bib3"><label>3</label><mixed-citation>
Baker, I. T., Harper, A. B., da Rocha, H. R., Denning, A. S., Araújo,
A. C., Borma, L. S., Freitas, H. C., Goulden, M. L., Manzi, A. O., Miller,
S. D., Nobre, A. D., Restrepo-Coupe, N., Saleska, S. R., Stöckli, R.,
von Randow, C., and Wofsy, S. C.: Surface ecophysiological behavior across
vegetation and moisture gradients in tropical South America, Agr. Forest
Meteorol., 182–183, 177–188, 2013.</mixed-citation></ref>
      <ref id="bib1.bib4"><label>4</label><mixed-citation>Baldocchi, D. D. and Ma, S.: How will land use affect air temperature in the
surface boundary layer? Lessons learned from a comparative study on the
energy balance of an oak savanna and annual grassland in California, USA,
Tellus B, 65, 19994, <ext-link xlink:href="http://dx.doi.org/10.3402/tellusb.v65i0.19994" ext-link-type="DOI">10.3402/tellusb.v65i0.19994</ext-link>, 2013.</mixed-citation></ref>
      <ref id="bib1.bib5"><label>5</label><mixed-citation>
Baldocchi, D. D., Wilson, K., and Gu, L.: How the environment, canopy
structure and canopy physiological functioning influence carbon, water and
energy fluxes of a temperate broad-leaved deciduous forest-An assessment with
the biophysical model CANOAK, Tree Phys., 22, 1065, 2002.</mixed-citation></ref>
      <ref id="bib1.bib6"><label>6</label><mixed-citation>
Ball, J. T., Woodrow, I. E., and Berry, J. A.: A model predicting stomatal
conductance and its contribution to the control of photosynthesis under
different environmental conditions, in: Progress in Photosynthesis Research,
edited by: Biggins, J. and Nijhoff, M., Dordrecht, Martinus–Nijhoff Publishers,
Dordrecht, the Netherlands, 5.221–5.224, 1987.</mixed-citation></ref>
      <ref id="bib1.bib7"><label>7</label><mixed-citation>Blyth, E., Gash, J., Lloyd, A., Pryor, M., Weedon, G. P., and Shuttleworth,
W. J.: Evaluating the JULES Land Surface Model Energy Fluxes Using FLUXNET
Data, J. Hydrometeorol., 11, 509–519, <ext-link xlink:href="http://dx.doi.org/10.1175/2009JHM1183.1" ext-link-type="DOI">10.1175/2009JHM1183.1</ext-link>, 2010.</mixed-citation></ref>
      <ref id="bib1.bib8"><label>8</label><mixed-citation>
Boegh, E. and Soegaard, H.: Remote sensing based estimation of evapotranspiration
rates, Int. J. Remote Sens., 25, 2535–2551, 2004.</mixed-citation></ref>
      <ref id="bib1.bib9"><label>9</label><mixed-citation>
Boegh, E., Soegaard, H., and Thomsen, A.: Evaluating evapotranspiration rates
and surface conditions using Landsat TM to estimate atmospheric resistance and
surface resistance, Remote Sens. Environ., 79, 329–343, 2002.</mixed-citation></ref>
      <ref id="bib1.bib10"><label>10</label><mixed-citation>Bonan, G. B., Williams, M., Fisher, R. A., and Oleson, K. W.: Modeling
stomatal conductance in the earth system: linking leaf water-use efficiency
and water transport along the soil–plant–atmosphere continuum, Geosci.
Model Dev., 7, 2193–2222, <ext-link xlink:href="http://dx.doi.org/10.5194/gmd-7-2193-2014" ext-link-type="DOI">10.5194/gmd-7-2193-2014</ext-link>, 2014.</mixed-citation></ref>
      <ref id="bib1.bib11"><label>11</label><mixed-citation>
Bosveld, F. C. and Bouten, W.: Evaluating a model of evaporation and
transpiration with observations in a partially wet Douglas-fir forest,
Bound.-Lay. Meteorol., 108, 365–396, 2003.</mixed-citation></ref>
      <ref id="bib1.bib12"><label>12</label><mixed-citation>Boulet, G., Mougenot, B., Lhomme, J.-P., Fanise, P., Lili-Chabaane, Z., Olioso,
A., Bahir, M., Rivalland, V., Jarlan, L., Merlin, O., Coudert, B., Er-Raki, S.,
and Lagouarde, J.-P.: The SPARSE model for the prediction of water stress and
evapotranspiration components from thermal infra-red data and its evaluation
over irrigated and rainfed wheat, Hydrol. Earth Syst. Sci., 19, 4653–4672,
<ext-link xlink:href="http://dx.doi.org/10.5194/hess-19-4653-2015" ext-link-type="DOI">10.5194/hess-19-4653-2015</ext-link>, 2015.</mixed-citation></ref>
      <ref id="bib1.bib13"><label>13</label><mixed-citation>
Bowen, I. S.: The ratio of heat losses by conduction and by evaporation from
any water surface, Phys. Rev., 27, 779–787, 1926.</mixed-citation></ref>
      <ref id="bib1.bib14"><label>14</label><mixed-citation>
Brutsaert, W. and Stricker, H.: An advection-aridity approach to estimate
actual regional evapotranspiration, Water Resour. Res., 15, 443– 450, 1979.</mixed-citation></ref>
      <ref id="bib1.bib15"><label>15</label><mixed-citation>
Chen, F. and Schwerdtfeger, P.: Flux-gradient relationships for momentum and
heat over a rough natural surface, Q. J. Roy. Meteorol. Soc., 115, 335–352, 1989.</mixed-citation></ref>
      <ref id="bib1.bib16"><label>16</label><mixed-citation>
Chen, L., Zhang, Z., Li, Z., Tang, J., Caldwell, P., and Zhang, W.:
Biophysical control of whole tree transpiration under an urban environment in
Northern China, J. Hydrol., 402, 388–400, 2011.</mixed-citation></ref>
      <ref id="bib1.bib17"><label>17</label><mixed-citation>
Choudhury, B. J. and Monteith, J. L.: Implications of stomatal response to
saturation deficit for the heat balance of vegetation, Agr. Forest Meteorol.,
36, 215–225, 1986.</mixed-citation></ref>
      <ref id="bib1.bib18"><label>18</label><mixed-citation>
Christoffersena, B. O., Restrepo-Coup, N., Arain, M. A., Baker, I. T.,
Cestaro, B. P., Ciais, P., Fisher, J. B., Galbraith, D., Guan, X., Gulden,
L., van den Hurk, B., Ichii, K., Imbuzeiro, H., Jain, A., Levine, N.,
Miguez-Macho, G., Poulter, B., Roberti, D. R., Sakaguchi, K., Sahoo, A.,
Schaefer, K., Shi, M., Verbeeck, H., Yang, Z. -L., Araújox, A. C.,
Kruijt, B., and Manzi, A. O.: Mechanisms of water supply and vegetation
demand govern the seasonality and magnitude of evapotranspiration in Amazonia
and Cerrado, Agr. Forest Meteorol., 191, 33–50, 2014.</mixed-citation></ref>
      <ref id="bib1.bib19"><label>19</label><mixed-citation>
Colaizzi, P. D., Kustas, W. P., Anderson, M. C., Agam, N., Tolk, J. A.,
Evett, S. R., Howell, T. A., Gowda, P. H., and O'Shaughnessya, S. A.:
Two-source energy balance model estimates of evapotranspiration using
component and composite surface temperatures, Adv. Water Resour., 50,
134–151, 2012.</mixed-citation></ref>
      <ref id="bib1.bib20"><label>20</label><mixed-citation>Contini, D., Donateo, A., and Belosi, F.: Accuracy of Measurements of Turbulent
Phenomena in the Surface Layer with an Ultrasonic Anemometer, J. Atmos. Ocean.
Tech., 23, 785–801, <ext-link xlink:href="http://dx.doi.org/10.1175/JTECH1881.1" ext-link-type="DOI">10.1175/JTECH1881.1</ext-link>, 2006.</mixed-citation></ref>
      <ref id="bib1.bib21"><label>21</label><mixed-citation>Costa, M. H., Biajoli, M. C., Sanches, L., Malhado, A. C. M., Hutyra, L. R.,
da Rocha, H. R., Aguiar, R. G., and de Araújo, A. C.: Atmospheric versus
vegetation controls of Amazonian tropical rain forest evapotranspiration: Are
the wet and seasonally dry rain forests any different?, J. Geophys. Res.,
115, G04021, <ext-link xlink:href="http://dx.doi.org/10.1029/2009JG001179" ext-link-type="DOI">10.1029/2009JG001179</ext-link>, 2010.</mixed-citation></ref>
      <ref id="bib1.bib22"><label>22</label><mixed-citation>
Cox, P. M., Betts, R. A., Jones, C. D., Spall, S. A., and Totterdell, I. J.:
Acceleration of global warming due to carbon-cycle feedbacks in a coupled
climate model, Nature, 408, 184–187, 2000.</mixed-citation></ref>
      <ref id="bib1.bib23"><label>23</label><mixed-citation>
da Rocha, H. R., Goulden, M., Miller, S., Menton, M., Pinto, L., Freitas, H.,
and Figueira, A. S.: Seasonality of water and heat fluxes over a tropical forest
in eastern Amazonia, Ecol. Appl., 14, 22–32, 2004.</mixed-citation></ref>
      <ref id="bib1.bib24"><label>24</label><mixed-citation>da Rocha, H. R., Manzi, A. O., Cabral, O. M., Miller, S. D., Goulden, M. L.,
Saleska, S. R., Retro-Coupe, N., Wofsy, S. C., Borma, L. S., Artaxo, P.,
Vourlitis, G., Nogueira, J. S., Cardoso, F. L., Nobre, A. D., Kruijt, B.,
Freitas, H. C., von Randow, C., Aguiar, R. G., and Maia, J. F.: Patterns of
water and heat flux across a biome gradient from tropical forest to savanna
in Brazil, J. Geophys. Res., 114, G00B12, <ext-link xlink:href="http://dx.doi.org/10.1029/2007JG000640" ext-link-type="DOI">10.1029/2007JG000640</ext-link>, 2009.</mixed-citation></ref>
      <ref id="bib1.bib25"><label>25</label><mixed-citation>
Davidson, E. A., de Araújo, A. C., Artaxo, P., Balch, J. K., Brown,
I. F., Bustamante, M. M. C., Coe, M. T., DeFries, R. S., Keller, M., Longo,
M., Munger, J. W., Schroeder, W., Soares-Filho, B. S., Souza, C. M., and
Wofsy, S. C.: The Amazon basin in transition, Nature, 481, 321–328, 2012.</mixed-citation></ref>
      <ref id="bib1.bib26"><label>26</label><mixed-citation>
de Goncalves, L. G. G., Borak, J. S., Costa, M. H., Saleska, S. R., Baker,
I., Restrepo-Coupe, N., Muza, M. N., Poulter, B., Verbeeck, H., Fisher,
J. B., Arain, M. A., Arkin, P., Cestaro, B. P., Christoffersen, B.,
Galbraith, D., Guan, X., van den Hurk, B. J. J. M., Ichii, K., Imbuzeiro,
H. M. A., Jain, A. K., Levine, N., Lu, C., Miguez-Macho, G., Roberti, D. R.,
Sahoo, A., Sakaguchi, K., Schaefer, K., Shi, M., Shuttleworth, W. J., Tian,
H., Yang, Z.-L., and Zeng, X. : Overview of the Large-Scale
Biosphere–Atmosphere Experiment in Amazonia Data Model Intercomparison
Project (LBA-DMIP), Agr. Forest Meteorol., 182–183, 111–127, 2013.</mixed-citation></ref>
      <ref id="bib1.bib27"><label>27</label><mixed-citation>
Denmead, O. T. and Shaw, R. H.: Availability of soil water to plants as
affected by soil moisture content and meteorological conditions, Agron. J.,
54, 385–390, 1962.</mixed-citation></ref>
      <ref id="bib1.bib28"><label>28</label><mixed-citation>Dolman, A. J., Miralles, D. G., and de Jeu, R. A. M.: Fifty years since
Monteith's 1965 seminal paper: the emergence of global ecohydrology,
Ecohydrology, 7, 897–902, <ext-link xlink:href="http://dx.doi.org/10.1002/eco.1505" ext-link-type="DOI">10.1002/eco.1505</ext-link>, 2014.</mixed-citation></ref>
      <ref id="bib1.bib29"><label>29</label><mixed-citation>Drewry, D. T., Kumar, P., Long, S., Bernacchi, C., Liang, X. Z., and
Sivapalan, M.: Ecohydrological responses of dense canopies to environmental
variability: 1. Interplay between vertical structure and photosynthetic
pathway, J. Geophys. Res.-Biogeo., 115, G04022, <ext-link xlink:href="http://dx.doi.org/10.1029/2010JG001340" ext-link-type="DOI">10.1029/2010JG001340</ext-link>,
2010.</mixed-citation></ref>
      <ref id="bib1.bib30"><label>30</label><mixed-citation>
Ershadi, A., McCabe, M. F., Evans, J. P., and Wood, E. F.: Impact of model
structure and parameterization on Penman–Monteith type evaporation models,
J. Hydrol., 525, 521–535, 2015.</mixed-citation></ref>
      <ref id="bib1.bib31"><label>31</label><mixed-citation>
Farquhar, G. D.: Feedforward responses of stomata to humidity, Aust. J. Plant
Physiol., 5, 787-800, 1978.</mixed-citation></ref>
      <ref id="bib1.bib32"><label>32</label><mixed-citation>
Foken, T.: 50 years of the Monin–Obukhov similarity theory, Bound.-Lay.
Meteorol., 2, 7–29, 2006.</mixed-citation></ref>
      <ref id="bib1.bib33"><label>33</label><mixed-citation>Gatti, L. V., Gloor, M., Miller, J. B., Doughty, C. E., Malhi, Y., Domingues,
L. G., Basso, L. S., Martinewski, A., Correia, C. S. C., Borges, V. F.,
Freitas, S., Braz, R., Anderson, L. O., Rocha, H., Grace, J., Phillips,
O. L., and Lloyd, J.: Drought sensitivity of Amazonian carbon balance
revealed by atmospheric measurements, Nature, 506, 76–80,
<ext-link xlink:href="http://dx.doi.org/10.1038/nature12957" ext-link-type="DOI">10.1038/nature12957</ext-link>, 2014.</mixed-citation></ref>
      <ref id="bib1.bib34"><label>34</label><mixed-citation>Gibson, L. A., Münch, Z., and Engelbrecht, J.: Particular uncertainties
encountered in using a pre-packaged SEBS model to derive evapotranspiration
in a heterogeneous study area in South Africa, Hydrol. Earth Syst. Sci., 15,
295–310, <ext-link xlink:href="http://dx.doi.org/10.5194/hess-15-295-2011" ext-link-type="DOI">10.5194/hess-15-295-2011</ext-link>, 2011.</mixed-citation></ref>
      <ref id="bib1.bib35"><label>35</label><mixed-citation>
Gloor, M., Brienen, R. J. W., Galbraith, D., Feldpausch, T. R.,
Schöngart, J., Guyot, J.-L., Espinoza, J. C., Lloyd, J., and Phillips,
O. L.: Intensification of the Amazon hydrological cycle over the last two
decades, Geophys. Res. Lett., 40, 1729–1733, 2013.</mixed-citation></ref>
      <ref id="bib1.bib36"><label>36</label><mixed-citation>Harper, A., Baker, I. T., Denning, A. S., Randall, D. A., Dazlich, D., and
Branson, M.: Impact of evapotranspiration on dry season climate in the Amazon
Forest, J. Climate, 27, 574–591, <ext-link xlink:href="http://dx.doi.org/10.1175/JCLI-D-13-00074.1" ext-link-type="DOI">10.1175/JCLI-D-13-00074.1</ext-link>, 2014.</mixed-citation></ref>
      <ref id="bib1.bib37"><label>37</label><mixed-citation>Hasler, N. and Avissar, R.: What controls evapotranspiration in the Amazon
Basin, J. Hydrometeorol., 8, 380–395, <ext-link xlink:href="http://dx.doi.org/10.1175/JHM587.1" ext-link-type="DOI">10.1175/JHM587.1</ext-link>, 2007.</mixed-citation></ref>
      <ref id="bib1.bib38"><label>38</label><mixed-citation>Hilker, T., Lyapustin, A. I., Tucker, C. J., Hall, F. G., Myneni, R. B., Wang,
Y., Bi, J., de Moura, Y. M., and Sellers, P. J.: Vegetation dynamics and
rainfall sensitivity of the Amazon, P. Natl. Acad. Sci. USA, 111,
16041–16046, <ext-link xlink:href="http://dx.doi.org/10.1073/pnas.1404870111" ext-link-type="DOI">10.1073/pnas.1404870111</ext-link>, 2014.</mixed-citation></ref>
      <ref id="bib1.bib39"><label>39</label><mixed-citation>
Holwerda, F., Bruijnzeela, L. A., Scatenac, F. N., Vugtsa, H. F., and Meestersa,
A. G. C. A.: Wet canopy evaporation from a Puerto Rican lower montane rain forest:
the importance of realistically estimated aerodynamic conductance, J. Hydrol.,
414–415, 1–15, 2012.</mixed-citation></ref>
      <ref id="bib1.bib40"><label>40</label><mixed-citation>
Huntingford, C., Fisher, R. A., Mercado, L., Booth, B. B., Sitch, S., Harris,
P. P., Cox, P. M., Jones, C. D., Betts, R. A., Malhi, Y., Harris, G. R.,
Collins, M., and Moorcroft, P.: Towards quantifying uncertainty in
predictions of Amazon 'dieback', Philos. T. Roy. Soc. Lond. B, 363,
1857–1864, 2008.</mixed-citation></ref>
      <ref id="bib1.bib41"><label>41</label><mixed-citation>
Jarvis, P. G.: The interpretation of leaf water potential and stomatal conductance
found in canopies in the field, Philos. T. Roy. Soc. Lond. B, 273, 593–610, 1976.</mixed-citation></ref>
      <ref id="bib1.bib42"><label>42</label><mixed-citation>
Jarvis, P. G.: Transpiration and assimilation of trees and agricultural crops:
the 'omega' factor, in: Attributes of Trees and Crop Plants, edited by: Cannell,
M. G. R. and Jackson, J. E., Institute of terrestrial Ecology, Edinburg,
UK, 460–480, 1986.</mixed-citation></ref>
      <ref id="bib1.bib43"><label>43</label><mixed-citation>
Jarvis, P. G. and McNaughton, K. G.: Stomatal control of transpiration: scaling
up from leaf to region, Adv. Ecol. Res., 15, 1–49, 1986.</mixed-citation></ref>
      <ref id="bib1.bib44"><label>44</label><mixed-citation>
Jones, H. G.: Stomatal control of photosynthesis and transpiration, J. Exp. Bot.,
49, 387–398, 1998.</mixed-citation></ref>
      <ref id="bib1.bib45"><label>45</label><mixed-citation>
Kumagai, T., Saitoh, T. M., Sato, Y., Morooka, T., Manfroi, O. J., Kuraji,
K., and Suzuki, M.: Transpiration, canopy conductance and the decoupling
coefficient of a lowland mixed dipterocarp forest in Sarawak, Borneo: dry
spell effects, J. Hydrol., 287, 237–251, 2004.</mixed-citation></ref>
      <ref id="bib1.bib46"><label>46</label><mixed-citation>
Kustas, W. P. and Anderson, M. C.: Advances in thermal infrared remote sensing
for land surface modeling, Agr. Forest Meteorol., 149, 2071–2081, 2009.</mixed-citation></ref>
      <ref id="bib1.bib47"><label>47</label><mixed-citation>Lawrence, D. and Vandecar, K.: Effects of tropical deforestation on climate
and agriculture, Nat. Clim. Change, 5, 27–36, <ext-link xlink:href="http://dx.doi.org/10.1038/nclimate2430" ext-link-type="DOI">10.1038/nclimate2430</ext-link>, 2015.</mixed-citation></ref>
      <ref id="bib1.bib48"><label>48</label><mixed-citation>
Leuning, R.: A critical appraisal of a combined stomatal – photosynthesis
model for C3 plants, Plant Cell Environ., 18, 339–355, 1995.</mixed-citation></ref>
      <ref id="bib1.bib49"><label>49</label><mixed-citation>Leuzinger, S. and Kirner, C.: Rainfall distribution is the main driver of runoff
under future CO<inline-formula><mml:math display="inline"><mml:msub><mml:mi/><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:math></inline-formula>-concentration in a temperate deciduous forest, Global
Change Biol., 16, 246–254, 2010.</mixed-citation></ref>
      <ref id="bib1.bib50"><label>50</label><mixed-citation>Lhomme, J. P. and Montes, C.: Generalized combination equations for canopy
evaporation under dry and wet conditions, Hydrol. Earth Syst. Sci., 18, 1137–1149,
<ext-link xlink:href="http://dx.doi.org/10.5194/hess-18-1137-2014" ext-link-type="DOI">10.5194/hess-18-1137-2014</ext-link>, 2014.</mixed-citation></ref>
      <ref id="bib1.bib51"><label>51</label><mixed-citation>
Loescher, H. W., Gholz, H. L., Jacobs, J. M., and Oberbauer, S. F.: Energy
dynamics and modeled evapotranspiration from a wet tropical forest in Costa
Rica, J. Hydrol., 315, 274–294, 2005.</mixed-citation></ref>
      <ref id="bib1.bib52"><label>52</label><mixed-citation>
Ma, N., Zhang, Y., Guo, Y., Gao, H., Zhang, H., and Wang, Y.: Environmental
and biophysical controls on the evapotranspiration over the highest alpine
steppe, J. Hydrol., 529, 980–992, 2015.</mixed-citation></ref>
      <ref id="bib1.bib53"><label>53</label><mixed-citation>
Malhi, Y.: The productivity, metabolism and carbon cycle of tropical forest
vegetation, J. Ecol., 100, 65–75, 2012.</mixed-citation></ref>
      <ref id="bib1.bib54"><label>54</label><mixed-citation>Malhi, Y., Pegoraro, E., Nobre, A. D., Pereira, M. G. P., Grace, J., Culf,
A. D., and Clement, R.: The energy and water dynamics of a central Amazonian
rain forest, J. Geophys. Res., 107, 8061, <ext-link xlink:href="http://dx.doi.org/10.1029/2001JD000623" ext-link-type="DOI">10.1029/2001JD000623</ext-link>, 2002.</mixed-citation></ref>
      <ref id="bib1.bib55"><label>55</label><mixed-citation>
Mallick, K., Jarvis, A. J., Boegh, E., Fisher, J. B., Drewry, D. T., Tu,
K. P., Hook, S. J., Hulley, G., Ardö, J., Beringer, J., Arain, A., and
Niyogi, D.: A surface temperature initiated closure (STIC) for surface energy
balance fluxes, Remote Sens. Environ., 141, 243–261, 2014.</mixed-citation></ref>
      <ref id="bib1.bib56"><label>56</label><mixed-citation>Mallick, K., Boegh, E., Trebs, I., Alfieri, J. G., Kustas, W. P., Prueger,
J. H., Niyogi, D., Das, N., Drewry, D. T., Hoffmann, L., and Jarvis, A. J.:
Reintroducing radiometric surface temperature into the Penman–Monteith
formulation, Water Resour. Res., 51, 6214–6243, <ext-link xlink:href="http://dx.doi.org/10.1002/2014WR016106" ext-link-type="DOI">10.1002/2014WR016106</ext-link>,
2015.</mixed-citation></ref>
      <ref id="bib1.bib57"><label>57</label><mixed-citation>Massman, W. J.: A model study of kB<inline-formula><mml:math display="inline"><mml:mrow><mml:msubsup><mml:mi/><mml:mi>H</mml:mi><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:msubsup></mml:mrow></mml:math></inline-formula> for vegetated surfaces using
'localized near-field' Lagrangian theory, J. Hydrol., 223, 27–43, 1999.</mixed-citation></ref>
      <ref id="bib1.bib58"><label>58</label><mixed-citation>Matheny, A. M., Bohrer, G., Stoy, P., Baker, I. T., Black, A. T., Desai,
A. R., Dietze, M. C., Gough, C. M., Ivanov, V. Y., Jassal, R. S., Novick,
K. A., Schäfer, K. V. R., and Verbeeck, H.: Characterizing the diurnal
patterns of errors in the prediction of evapotranspiration by several
land-surface models: An NACP analysis, J. Geophys. Res.-Biogeo., 119,
1458–1473, <ext-link xlink:href="http://dx.doi.org/10.1002/2014JG002623" ext-link-type="DOI">10.1002/2014JG002623</ext-link>, 2014.</mixed-citation></ref>
      <ref id="bib1.bib59"><label>59</label><mixed-citation>
Matzner, S. and Comstock, J.: The temperature dependence of shoot hydraulic
resistance: implications for stomatal behaviour and hydraulic limitation,
Plant Cell Environ., 24, 1299–1307, 2001.</mixed-citation></ref>
      <ref id="bib1.bib60"><label>60</label><mixed-citation>
McNaughton, K. G. and Jarvis, P. G.: Using the Penman–Monteith equation predictively,
Agr. Water Manage., 8, 263–278, 1984.</mixed-citation></ref>
      <ref id="bib1.bib61"><label>61</label><mixed-citation>
McNaughton, K. G. and Jarvis, P. G.: Effects of spatial scale on stomatal control
of transpiration, Agr. Forest Meteorol., 54, 279–301, 1991.</mixed-citation></ref>
      <ref id="bib1.bib62"><label>62</label><mixed-citation>Medlyn, B. E., Duursma, R. A., Eamus, D., Ellsworth, D. S., Prentice, I. C.,
Bartons, C. V. M., Crous, K. Y., de Angelis, P., Freeman, M., and Wingate, L.:
Reconciling the optimal and empirical approaches to modelling stomatal
conductance, Global Change Biol., 17, 2134–2144,
<ext-link xlink:href="http://dx.doi.org/10.1111/j.1365-2486.2010.02375.x" ext-link-type="DOI">10.1111/j.1365-2486.2010.02375.x</ext-link>, 2011.</mixed-citation></ref>
      <ref id="bib1.bib63"><label>63</label><mixed-citation>
Meinzer, F. C., Goldstein, G., Holbrook, N. M., Jackson, P., and Cavelier, J.:
Stomatal and environmental control of transpiration in a lowland tropical forest
site, Plant Cell Environ., 16, 429–436, 1993.</mixed-citation></ref>
      <ref id="bib1.bib64"><label>64</label><mixed-citation>
Meinzer, F. C., Andrade, J. L., Goldstein, G., Holbrook, N. M., Cavelier, J.,
and Jackson, P.: Control of transpiration from upper canopy of a tropical forest:
the role of stomatal, boundary layer and hydraulic architecture components,
Plant Cell Environ., 20, 1242–1252, 1997.</mixed-citation></ref>
      <ref id="bib1.bib65"><label>65</label><mixed-citation>Mercado, L. M., Lloyd, J., Dolman, A. J., Sitch, S., and Pati, S.: Modelling
basin-wide variations in Amazon forest productivity – Part 1: Model calibration,
evaluation and upscaling functions for canopy photosynthesis, Biogeosciences,
6, 1247–1272, <ext-link xlink:href="http://dx.doi.org/10.5194/bg-6-1247-2009" ext-link-type="DOI">10.5194/bg-6-1247-2009</ext-link>, 2009.</mixed-citation></ref>
      <ref id="bib1.bib66"><label>66</label><mixed-citation>
Miglietta, F., Peressotti, A., Viola, R., Körner, C., and Amthor, J. S.:
Stomatal numbers, leaf and canopy conductance, and the control of
transpiration, P. Natl. Acad. Sci. USA, 108, E275–E275, 2011.</mixed-citation></ref>
      <ref id="bib1.bib67"><label>67</label><mixed-citation>
Monteith, J. L.: Evaporation and environment, in: Symposium of the Society for
Experimental Biology, The State and Movement of Water in Living Organisms, edited
by: Fogg, G. E., Academic Press, Inc., NY, 205–234, 1965.</mixed-citation></ref>
      <ref id="bib1.bib68"><label>68</label><mixed-citation>
Monteith, J. L.: Evaporation and surface temperature, Q. J. Roy. Meteorol. Soc.,
107, 1–27, 1981.</mixed-citation></ref>
      <ref id="bib1.bib69"><label>69</label><mixed-citation>
Monteith, J. L.: Accommodation between transpiring vegetation and the convective
boundary layer, J. Hydrol., 166, 251–263, 1995.</mixed-citation></ref>
      <ref id="bib1.bib70"><label>70</label><mixed-citation>
Monteith, J. L. and Unsworth, M. H.: Principles of Environmental Physics,
Elsevier, Amsterdam, 2008.</mixed-citation></ref>
      <ref id="bib1.bib71"><label>71</label><mixed-citation>
Motzer, T., Munz, N., Kuppers, M., Schmitt, D., and Anhuf, D.: Stomatal
conductance, transpiration and sap flow of tropical montane rain forest trees
in the southern Ecuadorian Andes, Tree Physiol., 25, 1283–1293, 2005.</mixed-citation></ref>
      <ref id="bib1.bib72"><label>72</label><mixed-citation>
Ocheltree, T. W., Nippert, J. B., and Prasad, P. V. V.: Stomatal responses to
changes in vapor pressure deficit reflect tissue-specific differences in
hydraulic conductance, Plant Cell Environ., 37, 132–139, 2014.</mixed-citation></ref>
      <ref id="bib1.bib73"><label>73</label><mixed-citation>
O'Grady, A. P., Eamus, D., and Hutley, L. B.: Transpiration increases during
the dry season: patterns of tree water use in eucalypt open-forests of northern
Australia, Tree Physiol., 19, 591—597, 1999.</mixed-citation></ref>
      <ref id="bib1.bib74"><label>74</label><mixed-citation>
Penman, H. L.: Natural evaporation from open water, bare soil, and grass, P.
Roy. Soc. Lond. A, 193, 120–146, 1948.</mixed-citation></ref>
      <ref id="bib1.bib75"><label>75</label><mixed-citation>Priante-Filho, N., Vourlitis, G. L., Hayashi, M. M. S., De Souza Nogueira,
J., Campelo Jr., J. H., Nunes, P. C., E Souza, L. S., Couto, E. G., Hoeger,
W., Raiter, F., Trienweiler, J. L., Miranda, E. J., Priante, P. C., Fritzen,
C. L., Lacerda, M., Pereira, L. C., Biudes, M. S., Suli, G. S., Shiraiwa, S.,
Do Paulo, S. R., and Silveira, M.: Comparison of the mass and energy
exchange of a pasture and a mature transitional tropical forest of the
southern Amazon Basin during a seasonal transition, Global Change Biol., 10,
863–876, <ext-link xlink:href="http://dx.doi.org/10.1111/j.1529-8817.2003.00775.x" ext-link-type="DOI">10.1111/j.1529-8817.2003.00775.x</ext-link>, 2004.</mixed-citation></ref>
      <ref id="bib1.bib76"><label>76</label><mixed-citation>
Priestley, C. H. B. and Taylor, R. J.: On the assessment of surface heat flux
and evaporation using large scale parameters, Mon. Weather Rev., 100, 81–92, 1972.</mixed-citation></ref>
      <ref id="bib1.bib77"><label>77</label><mixed-citation>
Prihodko, L., Denning, A. S., Hanan, N. P., Baker, I. T., and Davis, K.:
Sensitivity, uncertainty and time dependence of parameters in a complex land
surface model, Agr. Forest Meteorol., 148, 268–287, 2008.</mixed-citation></ref>
      <ref id="bib1.bib78"><label>78</label><mixed-citation>
Raupach, M. R.: Vegetation-atmosphere interaction and surface conductance at
leaf, canopy and regional scales, Agr. Forest Meteorol., 73, 151-179, 1995.</mixed-citation></ref>
      <ref id="bib1.bib79"><label>79</label><mixed-citation>
Raupach, M. R.: Influence of local feedbacks on land-air exchanges of energy
and carbon, Global Change Biol., 4, 477–494, 1998.</mixed-citation></ref>
      <ref id="bib1.bib80"><label>80</label><mixed-citation>
Raupach, M. R. and Finnigan, J. J.: Scale issues in boundary-layer
meteorology: surface energy balance in heterogeneous terrain, Hydrol.
Process., 9, 589–612, 1995.</mixed-citation></ref>
      <ref id="bib1.bib81"><label>81</label><mixed-citation>Renner, M., Hassler, S. K., Blume, T., Weiler, M., Hildebrandt, A., Guderle,
M., Schymanski, S. J., and Kleidon, A.: Dominant controls of transpiration
along a hillslope transect inferred from ecohydrological measurements and
thermodynamic limits, Hydrol. Earth Syst. Sci., 20, 2063–2083,
<ext-link xlink:href="http://dx.doi.org/10.5194/hess-20-2063-2016" ext-link-type="DOI">10.5194/hess-20-2063-2016</ext-link>, 2016.</mixed-citation></ref>
      <ref id="bib1.bib82"><label>82</label><mixed-citation>
Restrepo-Coupe, N., da Rocha, H. R., Hutyra, L. R., da Araujo, A. C., Borma,
L. S., Christoffersen, B., Cabral, O. M. R., de Camargo, P. B., Cardoso,
F. L., da Costa, A. C. L., Fitzjarrald, D. R., Goulden, M. L., Kruijt, B.,
Maiai, J. M. F., Malhi, Y. S., Manzi, A. O., Miller, S. D., Nobre, A. D.,
von Randow, C., Ság, L. D. A., Sakai, R. K., Tota, J., Wofsy, S. C., and
Zanchi, F. B.: What drives the seasonality of photosynthesis across the
Amazon basin? A cross-site analysis of eddy flux tower measurements from the
Brasil flux network, Agr. Forest Meteorol., 182–183, 128–144, 2013.</mixed-citation></ref>
      <ref id="bib1.bib83"><label>83</label><mixed-citation>
Richiardone, R., Manfrin, M., Ferrarese, S., Francone, C., Fernicola, V.,
Gavioso, R. M., and Mortarini, L.: Influence of the Sonic Anemometer
Temperature Calibration on Turbulent Heat-Flux Measurements, Bound.-Lay.
Meteorol., 142, 425–442, 2012.</mixed-citation></ref>
      <ref id="bib1.bib84"><label>84</label><mixed-citation>Roy, S. B. and Avissar, R.: Impact of land use/land cover change on regional
hydrometeorology in Amazonia, J. Geophys. Res., 107, 2156–2202,
<ext-link xlink:href="http://dx.doi.org/10.1029/2000JD000266" ext-link-type="DOI">10.1029/2000JD000266</ext-link>, 2002.</mixed-citation></ref>
      <ref id="bib1.bib85"><label>85</label><mixed-citation>Saleska, S. R., da Rocha, H. R., Huete, A. R., Nobre, A. D., Artaxo, P., and
Shimabukuro, Y. E.: LBA-ECO CD-32 Flux Tower Network Data Compilation,
Brazilian Amazon: 1999–2006, Data set, available at:
<uri>http://daac.ornl.gov</uri> from Oak Ridge National Laboratory Distributed
Active Archive Center, Oak Ridge, Tennessee, USA,
<ext-link xlink:href="http://dx.doi.org/10.3334/ORNLDAAC/1174" ext-link-type="DOI">10.3334/ORNLDAAC/1174</ext-link>, 2013.</mixed-citation></ref>
      <ref id="bib1.bib86"><label>86</label><mixed-citation>
Shuttleworth, W. J., Gurney, R. J., Hsu, A. Y., and Ormsby, J. P.: FIFE: The
variation in energy partition at surface flux sites, in Remote Sensing and
Large Scale Processes, in: Proceedings of the IAHS Third International Assembly,
vol. 186, edited by: Rango, A., IAHS Publ., Baltimore, Md, 67–74, 1989.</mixed-citation></ref>
      <ref id="bib1.bib87"><label>87</label><mixed-citation>
Shuttleworth, W. J.: Micrometeorology of temperate and tropical forest, Philos.
T. Roy. Soc. Lond. B, 324, 299–334, 1989.</mixed-citation></ref>
      <ref id="bib1.bib88"><label>88</label><mixed-citation>Shuttleworth, W. J.: Putting the “vap” into evaporation. Hydrol. Earth Syst.
Sci., 11, 210–244, <ext-link xlink:href="http://dx.doi.org/10.5194/hess-11-210-2007" ext-link-type="DOI">10.5194/hess-11-210-2007</ext-link>, 2007.</mixed-citation></ref>
      <ref id="bib1.bib89"><label>89</label><mixed-citation>
Shuttleworth, W. J. and Wallace, J. S.: Evaporation from sparse crops – an
energy combination theory, Q. J. Roy. Meteorol. Soc., 111, 839–855, 1985.</mixed-citation></ref>
      <ref id="bib1.bib90"><label>90</label><mixed-citation>
Simpson, I. J., Thurtell, G. W., Nuemann, H. H., den Hartog, G., and Edwards,
G. C.: The validity of similarity theory in the roughness sublayer above forests,
Bound.-Lay. Meteorol., 87, 69–99, 1998.</mixed-citation></ref>
      <ref id="bib1.bib91"><label>91</label><mixed-citation>Stella, P., Kortner, M., Ammann, C., Foken, T., Meixner, F. X., and Trebs, I.:
Measurements of nitrogen oxides and ozone fluxes by eddy covariance at a meadow:
evidence for an internal leaf resistance to NO<inline-formula><mml:math display="inline"><mml:msub><mml:mi/><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:math></inline-formula>, Biogeosciences, 10, 5997–6017,
<ext-link xlink:href="http://dx.doi.org/10.5194/bg-10-5997-2013" ext-link-type="DOI">10.5194/bg-10-5997-2013</ext-link>, 2013.</mixed-citation></ref>
      <ref id="bib1.bib92"><label>92</label><mixed-citation>
Streck, N. A.: Stomatal response to water vapor pressure deficit: an unsolved
issue, Revista Brasil, Agrociên, 9, 317–322, 2003.</mixed-citation></ref>
      <ref id="bib1.bib93"><label>93</label><mixed-citation>
Thom, A. S., Stewart, J. B., Oliver, H. R., and Gash, J. H. C.: Comparison of
aerodynamic and energy budget estimates of fluxes over a pine forest, Q. J. Roy.
Meteorol. Soc., 101, 93–105, 1975.</mixed-citation></ref>
      <ref id="bib1.bib94"><label>94</label><mixed-citation>
Tuzet, A., Perrier, A., and Leuning, R.: A coupled model of stomatal conductance,
photosynthesis and transpiration, Plant Cell Environ., 26, 1097–1116, 2003.</mixed-citation></ref>
      <ref id="bib1.bib95"><label>95</label><mixed-citation>van der Tol, C., van der Tol, S., Verhoef, A., Su, B., Timmermans, J., Houldcroft,
C., and Gieske, A.: A Bayesian approach to estimate sensible and latent heat
over vegetated land surface, Hydrol. Earth Syst. Sci., 13, 749–758,
<ext-link xlink:href="http://dx.doi.org/10.5194/hess-13-749-2009" ext-link-type="DOI">10.5194/hess-13-749-2009</ext-link>, 2009.</mixed-citation></ref>
      <ref id="bib1.bib96"><label>96</label><mixed-citation>
van Dijk, A. I. J. M., Gash, J. H., van Gorsel, E., Blanken, P. D., Cescatti,
A., Emmel, C., Gieleng, B., Harman, I. N., Kiely, G., Merbold, L.,
Montagnani, L., Moors, E., Sottocornola, M., Varlagin, A., Williams, C. A.,
and Wohlfahrt, G.: : Rainfall interception and the couple surface water and
energy balance, Agr. Forest Meteorol., 214–215, 402–415, 2015.</mixed-citation></ref>
      <ref id="bib1.bib97"><label>97</label><mixed-citation>
Venturini, V., Islam, S., and Rodriguez, L.: Estimation of evaporative fraction
and evapotranspiration from MODIS products using a complementary based model,
Remote Sens. Environ., 112, 132–141, 2008.</mixed-citation></ref>
      <ref id="bib1.bib98"><label>98</label><mixed-citation>
Villagarcía, L., Were, A., García, M., and Domingo, F.: Sensitivity of
a clumped model of evapotranspiration to surface resistance parameterisations:
Application in a semi-arid environment, Agr. Forest Meteorol., 150, 1065–1078, 2010.</mixed-citation></ref>
      <ref id="bib1.bib99"><label>99</label><mixed-citation>
Villani, M. G., Schmid, H. P., Su, H. B., Hutton, J. L., and Vogel, C. S.:
Turbulence statistics measurements in a northern hardwood forest, Bound.-Lay.
Meteorol., 108, 343–364, 2003.</mixed-citation></ref>
      <ref id="bib1.bib100"><label>100</label><mixed-citation>von Randow, R. C. S., von Randow, C., Hutjes, R. W. A., Tomasella, J., and
Kruijt, B.: Evapotranspiration of deforested areas in central and southwestern
Amazonia, Theor. Appl. Climatol., 109, 205–220, <ext-link xlink:href="http://dx.doi.org/10.1007/s00704-011-0570-1" ext-link-type="DOI">10.1007/s00704-011-0570-1</ext-link>, 2012.</mixed-citation></ref>
      <ref id="bib1.bib101"><label>101</label><mixed-citation>Zhang, Q., Manzoni, S., Katul, G., Porporato, A., and Yang, D.: The hysteretic
evapotranspiration-vapor pressure deficit relation, J. Geophys. Res.-Biogeo.,
119, 125–140, <ext-link xlink:href="http://dx.doi.org/10.1002/2013JG002484" ext-link-type="DOI">10.1002/2013JG002484</ext-link>, 2014.</mixed-citation></ref>
      <ref id="bib1.bib102"><label>102</label><mixed-citation>Zuecco, G., Penna, D., Borga, M., and van Meerveld, H. J.: A versatile index
to characterize hysteresis between hydrological variables at the runoff
event timescale, Hydrol. Process., 30, 1449–1466, <ext-link xlink:href="http://dx.doi.org/10.1002/hyp.10681" ext-link-type="DOI">10.1002/hyp.10681</ext-link>, 2016.</mixed-citation></ref>

  </ref-list><app-group content-type="float"><app><title/>

    </app></app-group></back>
    <!--<article-title-html>Canopy-scale biophysical controls of transpiration  and evaporation in the Amazon Basin</article-title-html>
<abstract-html><p class="p">Canopy and aerodynamic conductances (<i>g</i><sub>C</sub> and <i>g</i><sub>A</sub>) are two
of the key land surface biophysical variables that control the land surface
response of land surface schemes in climate models. Their representation is
crucial for predicting transpiration
(<img src="" width="" height="" class="graphics" alt=""/><i>E</i><sub>T</sub>) and evaporation
(<i>λ</i><i>E</i><sub>E</sub>) flux components of the terrestrial latent heat
flux (<i>λ</i><i>E</i>), which has important implications for global climate
change and water resource management. By physical integration of radiometric
surface temperature (<i>T</i><sub>R</sub>) into an integrated framework of the
Penman–Monteith and Shuttleworth–Wallace models, we present a novel
approach to directly quantify the canopy-scale biophysical controls on
<i>λ</i><i>E</i><sub>T</sub> and <i>λ</i><i>E</i><sub>E</sub> over multiple plant
functional types (PFTs) in the Amazon Basin. Combining data from six LBA
(Large-scale Biosphere-Atmosphere Experiment in Amazonia) eddy covariance
tower sites and a <i>T</i><sub>R</sub>-driven physically based modeling approach, we
identified the canopy-scale feedback-response mechanism between <i>g</i><sub>C</sub>,
<i>λ</i><i>E</i><sub>T</sub>, and atmospheric vapor pressure deficit (<i>D</i><sub>A</sub>),
without using any leaf-scale empirical parameterizations for the modeling.
The <i>T</i><sub>R</sub>-based model shows minor biophysical control on
<i>λ</i><i>E</i><sub>T</sub> during the wet (rainy) seasons where
<i>λ</i><i>E</i><sub>T</sub> becomes predominantly radiation driven and net
radiation (<i>R</i><sub>N</sub>) determines 75 to 80 % of the variances of
<i>λ</i><i>E</i><sub>T</sub>. However, biophysical control on <i>λ</i><i>E</i><sub>T</sub>
is dramatically increased during the dry seasons, and particularly the
2005 drought year, explaining 50 to 65 % of the variances of
<i>λ</i><i>E</i><sub>T</sub>, and indicates <i>λ</i><i>E</i><sub>T</sub> to be
substantially soil moisture driven during the rainfall deficit phase. Despite
substantial differences in <i>g</i><sub>A</sub> between forests and pastures, very
similar canopy–atmosphere “coupling” was found in these two biomes due to
soil moisture-induced decrease in <i>g</i><sub>C</sub> in the pasture. This revealed
the pragmatic aspect of the <i>T</i><sub>R</sub>-driven model behavior that exhibits
a high sensitivity of <i>g</i><sub>C</sub> to per unit change in wetness as opposed
to <i>g</i><sub>A</sub> that is marginally sensitive to surface wetness variability.
Our results reveal the occurrence of a significant hysteresis between
<i>λ</i><i>E</i><sub>T</sub> and <i>g</i><sub>C</sub> during the dry season for the pasture
sites, which is attributed to relatively low soil water availability as
compared to the rainforests, likely due to differences in rooting depth
between the two systems. Evaporation was significantly influenced by
<i>g</i><sub>A</sub> for all the PFTs and across all wetness conditions. Our
analytical framework logically captures the responses of <i>g</i><sub>C</sub> and
<i>g</i><sub>A</sub> to changes in atmospheric radiation, <i>D</i><sub>A</sub>, and surface
radiometric temperature, and thus appears to be promising for the improvement
of existing land–surface–atmosphere exchange parameterizations across a
range of spatial scales.</p></abstract-html>
<ref-html id="bib1.bib1"><label>1</label><mixed-citation>
Anderson, M. C., Norman, J. M., Kustas, W. P., Li, F., Prueger, J. H., and
Mecikalski, J. R.: A climatological study of evapotranspiration and moisture
stress across the continental United States: 1. Model formulation,
J. Geophys. Res., 112, D11112, <a href="http://dx.doi.org/10.1029/2006JD007507" target="_blank">doi:10.1029/2006JD007507</a>, 2007.
</mixed-citation></ref-html>
<ref-html id="bib1.bib2"><label>2</label><mixed-citation>
Andreae, M. O., Artaxo, P., Brandao, C., Carswell, F. E., Ciccioli, P.,
da Costa, A. L., Culf, A. D., Esteves, J. L., Gash, J. H. C., Grace, J.,
Kabat, P., Lelieveld, J., Malhi, Y., Manzi, A. O., Meixner, F. X., Nobre,
A. D., Nobre, C., Ruivo, M. d. L. P., Silva-Dias, M. A., Stefani, P.,
Valentini, R., von Jouanne, J., and Waterloo, M. J.: Biogeochemical cycling
of carbon, water, energy, trace gases, and aerosols in Amazonia: The
LBA-EUSTACH experiments, J. Geophys. Res., 107, D208066,
<a href="http://dx.doi.org/10.1029/2001JD000524" target="_blank">doi:10.1029/2001JD000524</a>, 2002.
</mixed-citation></ref-html>
<ref-html id="bib1.bib3"><label>3</label><mixed-citation>
Baker, I. T., Harper, A. B., da Rocha, H. R., Denning, A. S., Araújo,
A. C., Borma, L. S., Freitas, H. C., Goulden, M. L., Manzi, A. O., Miller,
S. D., Nobre, A. D., Restrepo-Coupe, N., Saleska, S. R., Stöckli, R.,
von Randow, C., and Wofsy, S. C.: Surface ecophysiological behavior across
vegetation and moisture gradients in tropical South America, Agr. Forest
Meteorol., 182–183, 177–188, 2013.
</mixed-citation></ref-html>
<ref-html id="bib1.bib4"><label>4</label><mixed-citation>
Baldocchi, D. D. and Ma, S.: How will land use affect air temperature in the
surface boundary layer? Lessons learned from a comparative study on the
energy balance of an oak savanna and annual grassland in California, USA,
Tellus B, 65, 19994, <a href="http://dx.doi.org/10.3402/tellusb.v65i0.19994" target="_blank">doi:10.3402/tellusb.v65i0.19994</a>, 2013.
</mixed-citation></ref-html>
<ref-html id="bib1.bib5"><label>5</label><mixed-citation>
Baldocchi, D. D., Wilson, K., and Gu, L.: How the environment, canopy
structure and canopy physiological functioning influence carbon, water and
energy fluxes of a temperate broad-leaved deciduous forest-An assessment with
the biophysical model CANOAK, Tree Phys., 22, 1065, 2002.
</mixed-citation></ref-html>
<ref-html id="bib1.bib6"><label>6</label><mixed-citation>
Ball, J. T., Woodrow, I. E., and Berry, J. A.: A model predicting stomatal
conductance and its contribution to the control of photosynthesis under
different environmental conditions, in: Progress in Photosynthesis Research,
edited by: Biggins, J. and Nijhoff, M., Dordrecht, Martinus–Nijhoff Publishers,
Dordrecht, the Netherlands, 5.221–5.224, 1987.
</mixed-citation></ref-html>
<ref-html id="bib1.bib7"><label>7</label><mixed-citation>
Blyth, E., Gash, J., Lloyd, A., Pryor, M., Weedon, G. P., and Shuttleworth,
W. J.: Evaluating the JULES Land Surface Model Energy Fluxes Using FLUXNET
Data, J. Hydrometeorol., 11, 509–519, <a href="http://dx.doi.org/10.1175/2009JHM1183.1" target="_blank">doi:10.1175/2009JHM1183.1</a>, 2010.
</mixed-citation></ref-html>
<ref-html id="bib1.bib8"><label>8</label><mixed-citation>
Boegh, E. and Soegaard, H.: Remote sensing based estimation of evapotranspiration
rates, Int. J. Remote Sens., 25, 2535–2551, 2004.
</mixed-citation></ref-html>
<ref-html id="bib1.bib9"><label>9</label><mixed-citation>
Boegh, E., Soegaard, H., and Thomsen, A.: Evaluating evapotranspiration rates
and surface conditions using Landsat TM to estimate atmospheric resistance and
surface resistance, Remote Sens. Environ., 79, 329–343, 2002.
</mixed-citation></ref-html>
<ref-html id="bib1.bib10"><label>10</label><mixed-citation>
Bonan, G. B., Williams, M., Fisher, R. A., and Oleson, K. W.: Modeling
stomatal conductance in the earth system: linking leaf water-use efficiency
and water transport along the soil–plant–atmosphere continuum, Geosci.
Model Dev., 7, 2193–2222, <a href="http://dx.doi.org/10.5194/gmd-7-2193-2014" target="_blank">doi:10.5194/gmd-7-2193-2014</a>, 2014.
</mixed-citation></ref-html>
<ref-html id="bib1.bib11"><label>11</label><mixed-citation>
Bosveld, F. C. and Bouten, W.: Evaluating a model of evaporation and
transpiration with observations in a partially wet Douglas-fir forest,
Bound.-Lay. Meteorol., 108, 365–396, 2003.
</mixed-citation></ref-html>
<ref-html id="bib1.bib12"><label>12</label><mixed-citation>
Boulet, G., Mougenot, B., Lhomme, J.-P., Fanise, P., Lili-Chabaane, Z., Olioso,
A., Bahir, M., Rivalland, V., Jarlan, L., Merlin, O., Coudert, B., Er-Raki, S.,
and Lagouarde, J.-P.: The SPARSE model for the prediction of water stress and
evapotranspiration components from thermal infra-red data and its evaluation
over irrigated and rainfed wheat, Hydrol. Earth Syst. Sci., 19, 4653–4672,
<a href="http://dx.doi.org/10.5194/hess-19-4653-2015" target="_blank">doi:10.5194/hess-19-4653-2015</a>, 2015.
</mixed-citation></ref-html>
<ref-html id="bib1.bib13"><label>13</label><mixed-citation>
Bowen, I. S.: The ratio of heat losses by conduction and by evaporation from
any water surface, Phys. Rev., 27, 779–787, 1926.
</mixed-citation></ref-html>
<ref-html id="bib1.bib14"><label>14</label><mixed-citation>
Brutsaert, W. and Stricker, H.: An advection-aridity approach to estimate
actual regional evapotranspiration, Water Resour. Res., 15, 443– 450, 1979.
</mixed-citation></ref-html>
<ref-html id="bib1.bib15"><label>15</label><mixed-citation>
Chen, F. and Schwerdtfeger, P.: Flux-gradient relationships for momentum and
heat over a rough natural surface, Q. J. Roy. Meteorol. Soc., 115, 335–352, 1989.
</mixed-citation></ref-html>
<ref-html id="bib1.bib16"><label>16</label><mixed-citation>
Chen, L., Zhang, Z., Li, Z., Tang, J., Caldwell, P., and Zhang, W.:
Biophysical control of whole tree transpiration under an urban environment in
Northern China, J. Hydrol., 402, 388–400, 2011.
</mixed-citation></ref-html>
<ref-html id="bib1.bib17"><label>17</label><mixed-citation>
Choudhury, B. J. and Monteith, J. L.: Implications of stomatal response to
saturation deficit for the heat balance of vegetation, Agr. Forest Meteorol.,
36, 215–225, 1986.
</mixed-citation></ref-html>
<ref-html id="bib1.bib18"><label>18</label><mixed-citation>
Christoffersena, B. O., Restrepo-Coup, N., Arain, M. A., Baker, I. T.,
Cestaro, B. P., Ciais, P., Fisher, J. B., Galbraith, D., Guan, X., Gulden,
L., van den Hurk, B., Ichii, K., Imbuzeiro, H., Jain, A., Levine, N.,
Miguez-Macho, G., Poulter, B., Roberti, D. R., Sakaguchi, K., Sahoo, A.,
Schaefer, K., Shi, M., Verbeeck, H., Yang, Z. -L., Araújox, A. C.,
Kruijt, B., and Manzi, A. O.: Mechanisms of water supply and vegetation
demand govern the seasonality and magnitude of evapotranspiration in Amazonia
and Cerrado, Agr. Forest Meteorol., 191, 33–50, 2014.
</mixed-citation></ref-html>
<ref-html id="bib1.bib19"><label>19</label><mixed-citation>
Colaizzi, P. D., Kustas, W. P., Anderson, M. C., Agam, N., Tolk, J. A.,
Evett, S. R., Howell, T. A., Gowda, P. H., and O'Shaughnessya, S. A.:
Two-source energy balance model estimates of evapotranspiration using
component and composite surface temperatures, Adv. Water Resour., 50,
134–151, 2012.
</mixed-citation></ref-html>
<ref-html id="bib1.bib20"><label>20</label><mixed-citation>
Contini, D., Donateo, A., and Belosi, F.: Accuracy of Measurements of Turbulent
Phenomena in the Surface Layer with an Ultrasonic Anemometer, J. Atmos. Ocean.
Tech., 23, 785–801, <a href="http://dx.doi.org/10.1175/JTECH1881.1" target="_blank">doi:10.1175/JTECH1881.1</a>, 2006.
</mixed-citation></ref-html>
<ref-html id="bib1.bib21"><label>21</label><mixed-citation>
Costa, M. H., Biajoli, M. C., Sanches, L., Malhado, A. C. M., Hutyra, L. R.,
da Rocha, H. R., Aguiar, R. G., and de Araújo, A. C.: Atmospheric versus
vegetation controls of Amazonian tropical rain forest evapotranspiration: Are
the wet and seasonally dry rain forests any different?, J. Geophys. Res.,
115, G04021, <a href="http://dx.doi.org/10.1029/2009JG001179" target="_blank">doi:10.1029/2009JG001179</a>, 2010.
</mixed-citation></ref-html>
<ref-html id="bib1.bib22"><label>22</label><mixed-citation>
Cox, P. M., Betts, R. A., Jones, C. D., Spall, S. A., and Totterdell, I. J.:
Acceleration of global warming due to carbon-cycle feedbacks in a coupled
climate model, Nature, 408, 184–187, 2000.
</mixed-citation></ref-html>
<ref-html id="bib1.bib23"><label>23</label><mixed-citation>
da Rocha, H. R., Goulden, M., Miller, S., Menton, M., Pinto, L., Freitas, H.,
and Figueira, A. S.: Seasonality of water and heat fluxes over a tropical forest
in eastern Amazonia, Ecol. Appl., 14, 22–32, 2004.
</mixed-citation></ref-html>
<ref-html id="bib1.bib24"><label>24</label><mixed-citation>
da Rocha, H. R., Manzi, A. O., Cabral, O. M., Miller, S. D., Goulden, M. L.,
Saleska, S. R., Retro-Coupe, N., Wofsy, S. C., Borma, L. S., Artaxo, P.,
Vourlitis, G., Nogueira, J. S., Cardoso, F. L., Nobre, A. D., Kruijt, B.,
Freitas, H. C., von Randow, C., Aguiar, R. G., and Maia, J. F.: Patterns of
water and heat flux across a biome gradient from tropical forest to savanna
in Brazil, J. Geophys. Res., 114, G00B12, <a href="http://dx.doi.org/10.1029/2007JG000640" target="_blank">doi:10.1029/2007JG000640</a>, 2009.
</mixed-citation></ref-html>
<ref-html id="bib1.bib25"><label>25</label><mixed-citation>
Davidson, E. A., de Araújo, A. C., Artaxo, P., Balch, J. K., Brown,
I. F., Bustamante, M. M. C., Coe, M. T., DeFries, R. S., Keller, M., Longo,
M., Munger, J. W., Schroeder, W., Soares-Filho, B. S., Souza, C. M., and
Wofsy, S. C.: The Amazon basin in transition, Nature, 481, 321–328, 2012.
</mixed-citation></ref-html>
<ref-html id="bib1.bib26"><label>26</label><mixed-citation>
de Goncalves, L. G. G., Borak, J. S., Costa, M. H., Saleska, S. R., Baker,
I., Restrepo-Coupe, N., Muza, M. N., Poulter, B., Verbeeck, H., Fisher,
J. B., Arain, M. A., Arkin, P., Cestaro, B. P., Christoffersen, B.,
Galbraith, D., Guan, X., van den Hurk, B. J. J. M., Ichii, K., Imbuzeiro,
H. M. A., Jain, A. K., Levine, N., Lu, C., Miguez-Macho, G., Roberti, D. R.,
Sahoo, A., Sakaguchi, K., Schaefer, K., Shi, M., Shuttleworth, W. J., Tian,
H., Yang, Z.-L., and Zeng, X. : Overview of the Large-Scale
Biosphere–Atmosphere Experiment in Amazonia Data Model Intercomparison
Project (LBA-DMIP), Agr. Forest Meteorol., 182–183, 111–127, 2013.
</mixed-citation></ref-html>
<ref-html id="bib1.bib27"><label>27</label><mixed-citation>
Denmead, O. T. and Shaw, R. H.: Availability of soil water to plants as
affected by soil moisture content and meteorological conditions, Agron. J.,
54, 385–390, 1962.
</mixed-citation></ref-html>
<ref-html id="bib1.bib28"><label>28</label><mixed-citation>
Dolman, A. J., Miralles, D. G., and de Jeu, R. A. M.: Fifty years since
Monteith's 1965 seminal paper: the emergence of global ecohydrology,
Ecohydrology, 7, 897–902, <a href="http://dx.doi.org/10.1002/eco.1505" target="_blank">doi:10.1002/eco.1505</a>, 2014.
</mixed-citation></ref-html>
<ref-html id="bib1.bib29"><label>29</label><mixed-citation>
Drewry, D. T., Kumar, P., Long, S., Bernacchi, C., Liang, X. Z., and
Sivapalan, M.: Ecohydrological responses of dense canopies to environmental
variability: 1. Interplay between vertical structure and photosynthetic
pathway, J. Geophys. Res.-Biogeo., 115, G04022, <a href="http://dx.doi.org/10.1029/2010JG001340" target="_blank">doi:10.1029/2010JG001340</a>,
2010.
</mixed-citation></ref-html>
<ref-html id="bib1.bib30"><label>30</label><mixed-citation>
Ershadi, A., McCabe, M. F., Evans, J. P., and Wood, E. F.: Impact of model
structure and parameterization on Penman–Monteith type evaporation models,
J. Hydrol., 525, 521–535, 2015.
</mixed-citation></ref-html>
<ref-html id="bib1.bib31"><label>31</label><mixed-citation>
Farquhar, G. D.: Feedforward responses of stomata to humidity, Aust. J. Plant
Physiol., 5, 787-800, 1978.
</mixed-citation></ref-html>
<ref-html id="bib1.bib32"><label>32</label><mixed-citation>
Foken, T.: 50 years of the Monin–Obukhov similarity theory, Bound.-Lay.
Meteorol., 2, 7–29, 2006.
</mixed-citation></ref-html>
<ref-html id="bib1.bib33"><label>33</label><mixed-citation>
Gatti, L. V., Gloor, M., Miller, J. B., Doughty, C. E., Malhi, Y., Domingues,
L. G., Basso, L. S., Martinewski, A., Correia, C. S. C., Borges, V. F.,
Freitas, S., Braz, R., Anderson, L. O., Rocha, H., Grace, J., Phillips,
O. L., and Lloyd, J.: Drought sensitivity of Amazonian carbon balance
revealed by atmospheric measurements, Nature, 506, 76–80,
<a href="http://dx.doi.org/10.1038/nature12957" target="_blank">doi:10.1038/nature12957</a>, 2014.
</mixed-citation></ref-html>
<ref-html id="bib1.bib34"><label>34</label><mixed-citation>
Gibson, L. A., Münch, Z., and Engelbrecht, J.: Particular uncertainties
encountered in using a pre-packaged SEBS model to derive evapotranspiration
in a heterogeneous study area in South Africa, Hydrol. Earth Syst. Sci., 15,
295–310, <a href="http://dx.doi.org/10.5194/hess-15-295-2011" target="_blank">doi:10.5194/hess-15-295-2011</a>, 2011.
</mixed-citation></ref-html>
<ref-html id="bib1.bib35"><label>35</label><mixed-citation>
Gloor, M., Brienen, R. J. W., Galbraith, D., Feldpausch, T. R.,
Schöngart, J., Guyot, J.-L., Espinoza, J. C., Lloyd, J., and Phillips,
O. L.: Intensification of the Amazon hydrological cycle over the last two
decades, Geophys. Res. Lett., 40, 1729–1733, 2013.
</mixed-citation></ref-html>
<ref-html id="bib1.bib36"><label>36</label><mixed-citation>
Harper, A., Baker, I. T., Denning, A. S., Randall, D. A., Dazlich, D., and
Branson, M.: Impact of evapotranspiration on dry season climate in the Amazon
Forest, J. Climate, 27, 574–591, <a href="http://dx.doi.org/10.1175/JCLI-D-13-00074.1" target="_blank">doi:10.1175/JCLI-D-13-00074.1</a>, 2014.
</mixed-citation></ref-html>
<ref-html id="bib1.bib37"><label>37</label><mixed-citation>
Hasler, N. and Avissar, R.: What controls evapotranspiration in the Amazon
Basin, J. Hydrometeorol., 8, 380–395, <a href="http://dx.doi.org/10.1175/JHM587.1" target="_blank">doi:10.1175/JHM587.1</a>, 2007.
</mixed-citation></ref-html>
<ref-html id="bib1.bib38"><label>38</label><mixed-citation>
Hilker, T., Lyapustin, A. I., Tucker, C. J., Hall, F. G., Myneni, R. B., Wang,
Y., Bi, J., de Moura, Y. M., and Sellers, P. J.: Vegetation dynamics and
rainfall sensitivity of the Amazon, P. Natl. Acad. Sci. USA, 111,
16041–16046, <a href="http://dx.doi.org/10.1073/pnas.1404870111" target="_blank">doi:10.1073/pnas.1404870111</a>, 2014.
</mixed-citation></ref-html>
<ref-html id="bib1.bib39"><label>39</label><mixed-citation>
Holwerda, F., Bruijnzeela, L. A., Scatenac, F. N., Vugtsa, H. F., and Meestersa,
A. G. C. A.: Wet canopy evaporation from a Puerto Rican lower montane rain forest:
the importance of realistically estimated aerodynamic conductance, J. Hydrol.,
414–415, 1–15, 2012.
</mixed-citation></ref-html>
<ref-html id="bib1.bib40"><label>40</label><mixed-citation>
Huntingford, C., Fisher, R. A., Mercado, L., Booth, B. B., Sitch, S., Harris,
P. P., Cox, P. M., Jones, C. D., Betts, R. A., Malhi, Y., Harris, G. R.,
Collins, M., and Moorcroft, P.: Towards quantifying uncertainty in
predictions of Amazon 'dieback', Philos. T. Roy. Soc. Lond. B, 363,
1857–1864, 2008.
</mixed-citation></ref-html>
<ref-html id="bib1.bib41"><label>41</label><mixed-citation>
Jarvis, P. G.: The interpretation of leaf water potential and stomatal conductance
found in canopies in the field, Philos. T. Roy. Soc. Lond. B, 273, 593–610, 1976.
</mixed-citation></ref-html>
<ref-html id="bib1.bib42"><label>42</label><mixed-citation>
Jarvis, P. G.: Transpiration and assimilation of trees and agricultural crops:
the 'omega' factor, in: Attributes of Trees and Crop Plants, edited by: Cannell,
M. G. R. and Jackson, J. E., Institute of terrestrial Ecology, Edinburg,
UK, 460–480, 1986.
</mixed-citation></ref-html>
<ref-html id="bib1.bib43"><label>43</label><mixed-citation>
Jarvis, P. G. and McNaughton, K. G.: Stomatal control of transpiration: scaling
up from leaf to region, Adv. Ecol. Res., 15, 1–49, 1986.
</mixed-citation></ref-html>
<ref-html id="bib1.bib44"><label>44</label><mixed-citation>
Jones, H. G.: Stomatal control of photosynthesis and transpiration, J. Exp. Bot.,
49, 387–398, 1998.
</mixed-citation></ref-html>
<ref-html id="bib1.bib45"><label>45</label><mixed-citation>
Kumagai, T., Saitoh, T. M., Sato, Y., Morooka, T., Manfroi, O. J., Kuraji,
K., and Suzuki, M.: Transpiration, canopy conductance and the decoupling
coefficient of a lowland mixed dipterocarp forest in Sarawak, Borneo: dry
spell effects, J. Hydrol., 287, 237–251, 2004.
</mixed-citation></ref-html>
<ref-html id="bib1.bib46"><label>46</label><mixed-citation>
Kustas, W. P. and Anderson, M. C.: Advances in thermal infrared remote sensing
for land surface modeling, Agr. Forest Meteorol., 149, 2071–2081, 2009.
</mixed-citation></ref-html>
<ref-html id="bib1.bib47"><label>47</label><mixed-citation>
Lawrence, D. and Vandecar, K.: Effects of tropical deforestation on climate
and agriculture, Nat. Clim. Change, 5, 27–36, <a href="http://dx.doi.org/10.1038/nclimate2430" target="_blank">doi:10.1038/nclimate2430</a>, 2015.
</mixed-citation></ref-html>
<ref-html id="bib1.bib48"><label>48</label><mixed-citation>
Leuning, R.: A critical appraisal of a combined stomatal – photosynthesis
model for C3 plants, Plant Cell Environ., 18, 339–355, 1995.
</mixed-citation></ref-html>
<ref-html id="bib1.bib49"><label>49</label><mixed-citation>
Leuzinger, S. and Kirner, C.: Rainfall distribution is the main driver of runoff
under future CO<sub>2</sub>-concentration in a temperate deciduous forest, Global
Change Biol., 16, 246–254, 2010.
</mixed-citation></ref-html>
<ref-html id="bib1.bib50"><label>50</label><mixed-citation>
Lhomme, J. P. and Montes, C.: Generalized combination equations for canopy
evaporation under dry and wet conditions, Hydrol. Earth Syst. Sci., 18, 1137–1149,
<a href="http://dx.doi.org/10.5194/hess-18-1137-2014" target="_blank">doi:10.5194/hess-18-1137-2014</a>, 2014.
</mixed-citation></ref-html>
<ref-html id="bib1.bib51"><label>51</label><mixed-citation>
Loescher, H. W., Gholz, H. L., Jacobs, J. M., and Oberbauer, S. F.: Energy
dynamics and modeled evapotranspiration from a wet tropical forest in Costa
Rica, J. Hydrol., 315, 274–294, 2005.
</mixed-citation></ref-html>
<ref-html id="bib1.bib52"><label>52</label><mixed-citation>
Ma, N., Zhang, Y., Guo, Y., Gao, H., Zhang, H., and Wang, Y.: Environmental
and biophysical controls on the evapotranspiration over the highest alpine
steppe, J. Hydrol., 529, 980–992, 2015.
</mixed-citation></ref-html>
<ref-html id="bib1.bib53"><label>53</label><mixed-citation>
Malhi, Y.: The productivity, metabolism and carbon cycle of tropical forest
vegetation, J. Ecol., 100, 65–75, 2012.
</mixed-citation></ref-html>
<ref-html id="bib1.bib54"><label>54</label><mixed-citation>
Malhi, Y., Pegoraro, E., Nobre, A. D., Pereira, M. G. P., Grace, J., Culf,
A. D., and Clement, R.: The energy and water dynamics of a central Amazonian
rain forest, J. Geophys. Res., 107, 8061, <a href="http://dx.doi.org/10.1029/2001JD000623" target="_blank">doi:10.1029/2001JD000623</a>, 2002.
</mixed-citation></ref-html>
<ref-html id="bib1.bib55"><label>55</label><mixed-citation>
Mallick, K., Jarvis, A. J., Boegh, E., Fisher, J. B., Drewry, D. T., Tu,
K. P., Hook, S. J., Hulley, G., Ardö, J., Beringer, J., Arain, A., and
Niyogi, D.: A surface temperature initiated closure (STIC) for surface energy
balance fluxes, Remote Sens. Environ., 141, 243–261, 2014.
</mixed-citation></ref-html>
<ref-html id="bib1.bib56"><label>56</label><mixed-citation>
Mallick, K., Boegh, E., Trebs, I., Alfieri, J. G., Kustas, W. P., Prueger,
J. H., Niyogi, D., Das, N., Drewry, D. T., Hoffmann, L., and Jarvis, A. J.:
Reintroducing radiometric surface temperature into the Penman–Monteith
formulation, Water Resour. Res., 51, 6214–6243, <a href="http://dx.doi.org/10.1002/2014WR016106" target="_blank">doi:10.1002/2014WR016106</a>,
2015.
</mixed-citation></ref-html>
<ref-html id="bib1.bib57"><label>57</label><mixed-citation>
Massman, W. J.: A model study of kB<sub><i>H</i></sub><sup>−1</sup> for vegetated surfaces using
'localized near-field' Lagrangian theory, J. Hydrol., 223, 27–43, 1999.
</mixed-citation></ref-html>
<ref-html id="bib1.bib58"><label>58</label><mixed-citation>
Matheny, A. M., Bohrer, G., Stoy, P., Baker, I. T., Black, A. T., Desai,
A. R., Dietze, M. C., Gough, C. M., Ivanov, V. Y., Jassal, R. S., Novick,
K. A., Schäfer, K. V. R., and Verbeeck, H.: Characterizing the diurnal
patterns of errors in the prediction of evapotranspiration by several
land-surface models: An NACP analysis, J. Geophys. Res.-Biogeo., 119,
1458–1473, <a href="http://dx.doi.org/10.1002/2014JG002623" target="_blank">doi:10.1002/2014JG002623</a>, 2014.
</mixed-citation></ref-html>
<ref-html id="bib1.bib59"><label>59</label><mixed-citation>
Matzner, S. and Comstock, J.: The temperature dependence of shoot hydraulic
resistance: implications for stomatal behaviour and hydraulic limitation,
Plant Cell Environ., 24, 1299–1307, 2001.
</mixed-citation></ref-html>
<ref-html id="bib1.bib60"><label>60</label><mixed-citation>
McNaughton, K. G. and Jarvis, P. G.: Using the Penman–Monteith equation predictively,
Agr. Water Manage., 8, 263–278, 1984.
</mixed-citation></ref-html>
<ref-html id="bib1.bib61"><label>61</label><mixed-citation>
McNaughton, K. G. and Jarvis, P. G.: Effects of spatial scale on stomatal control
of transpiration, Agr. Forest Meteorol., 54, 279–301, 1991.
</mixed-citation></ref-html>
<ref-html id="bib1.bib62"><label>62</label><mixed-citation>
Medlyn, B. E., Duursma, R. A., Eamus, D., Ellsworth, D. S., Prentice, I. C.,
Bartons, C. V. M., Crous, K. Y., de Angelis, P., Freeman, M., and Wingate, L.:
Reconciling the optimal and empirical approaches to modelling stomatal
conductance, Global Change Biol., 17, 2134–2144,
<a href="http://dx.doi.org/10.1111/j.1365-2486.2010.02375.x" target="_blank">doi:10.1111/j.1365-2486.2010.02375.x</a>, 2011.
</mixed-citation></ref-html>
<ref-html id="bib1.bib63"><label>63</label><mixed-citation>
Meinzer, F. C., Goldstein, G., Holbrook, N. M., Jackson, P., and Cavelier, J.:
Stomatal and environmental control of transpiration in a lowland tropical forest
site, Plant Cell Environ., 16, 429–436, 1993.
</mixed-citation></ref-html>
<ref-html id="bib1.bib64"><label>64</label><mixed-citation>
Meinzer, F. C., Andrade, J. L., Goldstein, G., Holbrook, N. M., Cavelier, J.,
and Jackson, P.: Control of transpiration from upper canopy of a tropical forest:
the role of stomatal, boundary layer and hydraulic architecture components,
Plant Cell Environ., 20, 1242–1252, 1997.
</mixed-citation></ref-html>
<ref-html id="bib1.bib65"><label>65</label><mixed-citation>
Mercado, L. M., Lloyd, J., Dolman, A. J., Sitch, S., and Pati, S.: Modelling
basin-wide variations in Amazon forest productivity – Part 1: Model calibration,
evaluation and upscaling functions for canopy photosynthesis, Biogeosciences,
6, 1247–1272, <a href="http://dx.doi.org/10.5194/bg-6-1247-2009" target="_blank">doi:10.5194/bg-6-1247-2009</a>, 2009.
</mixed-citation></ref-html>
<ref-html id="bib1.bib66"><label>66</label><mixed-citation>
Miglietta, F., Peressotti, A., Viola, R., Körner, C., and Amthor, J. S.:
Stomatal numbers, leaf and canopy conductance, and the control of
transpiration, P. Natl. Acad. Sci. USA, 108, E275–E275, 2011.
</mixed-citation></ref-html>
<ref-html id="bib1.bib67"><label>67</label><mixed-citation>
Monteith, J. L.: Evaporation and environment, in: Symposium of the Society for
Experimental Biology, The State and Movement of Water in Living Organisms, edited
by: Fogg, G. E., Academic Press, Inc., NY, 205–234, 1965.
</mixed-citation></ref-html>
<ref-html id="bib1.bib68"><label>68</label><mixed-citation>
Monteith, J. L.: Evaporation and surface temperature, Q. J. Roy. Meteorol. Soc.,
107, 1–27, 1981.
</mixed-citation></ref-html>
<ref-html id="bib1.bib69"><label>69</label><mixed-citation>
Monteith, J. L.: Accommodation between transpiring vegetation and the convective
boundary layer, J. Hydrol., 166, 251–263, 1995.
</mixed-citation></ref-html>
<ref-html id="bib1.bib70"><label>70</label><mixed-citation>
Monteith, J. L. and Unsworth, M. H.: Principles of Environmental Physics,
Elsevier, Amsterdam, 2008.
</mixed-citation></ref-html>
<ref-html id="bib1.bib71"><label>71</label><mixed-citation>
Motzer, T., Munz, N., Kuppers, M., Schmitt, D., and Anhuf, D.: Stomatal
conductance, transpiration and sap flow of tropical montane rain forest trees
in the southern Ecuadorian Andes, Tree Physiol., 25, 1283–1293, 2005.
</mixed-citation></ref-html>
<ref-html id="bib1.bib72"><label>72</label><mixed-citation>
Ocheltree, T. W., Nippert, J. B., and Prasad, P. V. V.: Stomatal responses to
changes in vapor pressure deficit reflect tissue-specific differences in
hydraulic conductance, Plant Cell Environ., 37, 132–139, 2014.
</mixed-citation></ref-html>
<ref-html id="bib1.bib73"><label>73</label><mixed-citation>
O'Grady, A. P., Eamus, D., and Hutley, L. B.: Transpiration increases during
the dry season: patterns of tree water use in eucalypt open-forests of northern
Australia, Tree Physiol., 19, 591—597, 1999.
</mixed-citation></ref-html>
<ref-html id="bib1.bib74"><label>74</label><mixed-citation>
Penman, H. L.: Natural evaporation from open water, bare soil, and grass, P.
Roy. Soc. Lond. A, 193, 120–146, 1948.
</mixed-citation></ref-html>
<ref-html id="bib1.bib75"><label>75</label><mixed-citation>
Priante-Filho, N., Vourlitis, G. L., Hayashi, M. M. S., De Souza Nogueira,
J., Campelo Jr., J. H., Nunes, P. C., E Souza, L. S., Couto, E. G., Hoeger,
W., Raiter, F., Trienweiler, J. L., Miranda, E. J., Priante, P. C., Fritzen,
C. L., Lacerda, M., Pereira, L. C., Biudes, M. S., Suli, G. S., Shiraiwa, S.,
Do Paulo, S. R., and Silveira, M.: Comparison of the mass and energy
exchange of a pasture and a mature transitional tropical forest of the
southern Amazon Basin during a seasonal transition, Global Change Biol., 10,
863–876, <a href="http://dx.doi.org/10.1111/j.1529-8817.2003.00775.x" target="_blank">doi:10.1111/j.1529-8817.2003.00775.x</a>, 2004.
</mixed-citation></ref-html>
<ref-html id="bib1.bib76"><label>76</label><mixed-citation>
Priestley, C. H. B. and Taylor, R. J.: On the assessment of surface heat flux
and evaporation using large scale parameters, Mon. Weather Rev., 100, 81–92, 1972.
</mixed-citation></ref-html>
<ref-html id="bib1.bib77"><label>77</label><mixed-citation>
Prihodko, L., Denning, A. S., Hanan, N. P., Baker, I. T., and Davis, K.:
Sensitivity, uncertainty and time dependence of parameters in a complex land
surface model, Agr. Forest Meteorol., 148, 268–287, 2008.
</mixed-citation></ref-html>
<ref-html id="bib1.bib78"><label>78</label><mixed-citation>
Raupach, M. R.: Vegetation-atmosphere interaction and surface conductance at
leaf, canopy and regional scales, Agr. Forest Meteorol., 73, 151-179, 1995.
</mixed-citation></ref-html>
<ref-html id="bib1.bib79"><label>79</label><mixed-citation>
Raupach, M. R.: Influence of local feedbacks on land-air exchanges of energy
and carbon, Global Change Biol., 4, 477–494, 1998.
</mixed-citation></ref-html>
<ref-html id="bib1.bib80"><label>80</label><mixed-citation>
Raupach, M. R. and Finnigan, J. J.: Scale issues in boundary-layer
meteorology: surface energy balance in heterogeneous terrain, Hydrol.
Process., 9, 589–612, 1995.
</mixed-citation></ref-html>
<ref-html id="bib1.bib81"><label>81</label><mixed-citation>
Renner, M., Hassler, S. K., Blume, T., Weiler, M., Hildebrandt, A., Guderle,
M., Schymanski, S. J., and Kleidon, A.: Dominant controls of transpiration
along a hillslope transect inferred from ecohydrological measurements and
thermodynamic limits, Hydrol. Earth Syst. Sci., 20, 2063–2083,
<a href="http://dx.doi.org/10.5194/hess-20-2063-2016" target="_blank">doi:10.5194/hess-20-2063-2016</a>, 2016.
</mixed-citation></ref-html>
<ref-html id="bib1.bib82"><label>82</label><mixed-citation>
Restrepo-Coupe, N., da Rocha, H. R., Hutyra, L. R., da Araujo, A. C., Borma,
L. S., Christoffersen, B., Cabral, O. M. R., de Camargo, P. B., Cardoso,
F. L., da Costa, A. C. L., Fitzjarrald, D. R., Goulden, M. L., Kruijt, B.,
Maiai, J. M. F., Malhi, Y. S., Manzi, A. O., Miller, S. D., Nobre, A. D.,
von Randow, C., Ság, L. D. A., Sakai, R. K., Tota, J., Wofsy, S. C., and
Zanchi, F. B.: What drives the seasonality of photosynthesis across the
Amazon basin? A cross-site analysis of eddy flux tower measurements from the
Brasil flux network, Agr. Forest Meteorol., 182–183, 128–144, 2013.
</mixed-citation></ref-html>
<ref-html id="bib1.bib83"><label>83</label><mixed-citation>
Richiardone, R., Manfrin, M., Ferrarese, S., Francone, C., Fernicola, V.,
Gavioso, R. M., and Mortarini, L.: Influence of the Sonic Anemometer
Temperature Calibration on Turbulent Heat-Flux Measurements, Bound.-Lay.
Meteorol., 142, 425–442, 2012.
</mixed-citation></ref-html>
<ref-html id="bib1.bib84"><label>84</label><mixed-citation>
Roy, S. B. and Avissar, R.: Impact of land use/land cover change on regional
hydrometeorology in Amazonia, J. Geophys. Res., 107, 2156–2202,
<a href="http://dx.doi.org/10.1029/2000JD000266" target="_blank">doi:10.1029/2000JD000266</a>, 2002.
</mixed-citation></ref-html>
<ref-html id="bib1.bib85"><label>85</label><mixed-citation>
Saleska, S. R., da Rocha, H. R., Huete, A. R., Nobre, A. D., Artaxo, P., and
Shimabukuro, Y. E.: LBA-ECO CD-32 Flux Tower Network Data Compilation,
Brazilian Amazon: 1999–2006, Data set, available at:
<a href="http://daac.ornl.gov" target="_blank">http://daac.ornl.gov</a> from Oak Ridge National Laboratory Distributed
Active Archive Center, Oak Ridge, Tennessee, USA,
<a href="http://dx.doi.org/10.3334/ORNLDAAC/1174" target="_blank">doi:10.3334/ORNLDAAC/1174</a>, 2013.
</mixed-citation></ref-html>
<ref-html id="bib1.bib86"><label>86</label><mixed-citation>
Shuttleworth, W. J., Gurney, R. J., Hsu, A. Y., and Ormsby, J. P.: FIFE: The
variation in energy partition at surface flux sites, in Remote Sensing and
Large Scale Processes, in: Proceedings of the IAHS Third International Assembly,
vol. 186, edited by: Rango, A., IAHS Publ., Baltimore, Md, 67–74, 1989.
</mixed-citation></ref-html>
<ref-html id="bib1.bib87"><label>87</label><mixed-citation>
Shuttleworth, W. J.: Micrometeorology of temperate and tropical forest, Philos.
T. Roy. Soc. Lond. B, 324, 299–334, 1989.
</mixed-citation></ref-html>
<ref-html id="bib1.bib88"><label>88</label><mixed-citation>
Shuttleworth, W. J.: Putting the “vap” into evaporation. Hydrol. Earth Syst.
Sci., 11, 210–244, <a href="http://dx.doi.org/10.5194/hess-11-210-2007" target="_blank">doi:10.5194/hess-11-210-2007</a>, 2007.
</mixed-citation></ref-html>
<ref-html id="bib1.bib89"><label>89</label><mixed-citation>
Shuttleworth, W. J. and Wallace, J. S.: Evaporation from sparse crops – an
energy combination theory, Q. J. Roy. Meteorol. Soc., 111, 839–855, 1985.
</mixed-citation></ref-html>
<ref-html id="bib1.bib90"><label>90</label><mixed-citation>
Simpson, I. J., Thurtell, G. W., Nuemann, H. H., den Hartog, G., and Edwards,
G. C.: The validity of similarity theory in the roughness sublayer above forests,
Bound.-Lay. Meteorol., 87, 69–99, 1998.
</mixed-citation></ref-html>
<ref-html id="bib1.bib91"><label>91</label><mixed-citation>
Stella, P., Kortner, M., Ammann, C., Foken, T., Meixner, F. X., and Trebs, I.:
Measurements of nitrogen oxides and ozone fluxes by eddy covariance at a meadow:
evidence for an internal leaf resistance to NO<sub>2</sub>, Biogeosciences, 10, 5997–6017,
<a href="http://dx.doi.org/10.5194/bg-10-5997-2013" target="_blank">doi:10.5194/bg-10-5997-2013</a>, 2013.
</mixed-citation></ref-html>
<ref-html id="bib1.bib92"><label>92</label><mixed-citation>
Streck, N. A.: Stomatal response to water vapor pressure deficit: an unsolved
issue, Revista Brasil, Agrociên, 9, 317–322, 2003.
</mixed-citation></ref-html>
<ref-html id="bib1.bib93"><label>93</label><mixed-citation>
Thom, A. S., Stewart, J. B., Oliver, H. R., and Gash, J. H. C.: Comparison of
aerodynamic and energy budget estimates of fluxes over a pine forest, Q. J. Roy.
Meteorol. Soc., 101, 93–105, 1975.
</mixed-citation></ref-html>
<ref-html id="bib1.bib94"><label>94</label><mixed-citation>
Tuzet, A., Perrier, A., and Leuning, R.: A coupled model of stomatal conductance,
photosynthesis and transpiration, Plant Cell Environ., 26, 1097–1116, 2003.
</mixed-citation></ref-html>
<ref-html id="bib1.bib95"><label>95</label><mixed-citation>
van der Tol, C., van der Tol, S., Verhoef, A., Su, B., Timmermans, J., Houldcroft,
C., and Gieske, A.: A Bayesian approach to estimate sensible and latent heat
over vegetated land surface, Hydrol. Earth Syst. Sci., 13, 749–758,
<a href="http://dx.doi.org/10.5194/hess-13-749-2009" target="_blank">doi:10.5194/hess-13-749-2009</a>, 2009.
</mixed-citation></ref-html>
<ref-html id="bib1.bib96"><label>96</label><mixed-citation>
van Dijk, A. I. J. M., Gash, J. H., van Gorsel, E., Blanken, P. D., Cescatti,
A., Emmel, C., Gieleng, B., Harman, I. N., Kiely, G., Merbold, L.,
Montagnani, L., Moors, E., Sottocornola, M., Varlagin, A., Williams, C. A.,
and Wohlfahrt, G.: : Rainfall interception and the couple surface water and
energy balance, Agr. Forest Meteorol., 214–215, 402–415, 2015.
</mixed-citation></ref-html>
<ref-html id="bib1.bib97"><label>97</label><mixed-citation>
Venturini, V., Islam, S., and Rodriguez, L.: Estimation of evaporative fraction
and evapotranspiration from MODIS products using a complementary based model,
Remote Sens. Environ., 112, 132–141, 2008.
</mixed-citation></ref-html>
<ref-html id="bib1.bib98"><label>98</label><mixed-citation>
Villagarcía, L., Were, A., García, M., and Domingo, F.: Sensitivity of
a clumped model of evapotranspiration to surface resistance parameterisations:
Application in a semi-arid environment, Agr. Forest Meteorol., 150, 1065–1078, 2010.
</mixed-citation></ref-html>
<ref-html id="bib1.bib99"><label>99</label><mixed-citation>
Villani, M. G., Schmid, H. P., Su, H. B., Hutton, J. L., and Vogel, C. S.:
Turbulence statistics measurements in a northern hardwood forest, Bound.-Lay.
Meteorol., 108, 343–364, 2003.
</mixed-citation></ref-html>
<ref-html id="bib1.bib100"><label>100</label><mixed-citation>
von Randow, R. C. S., von Randow, C., Hutjes, R. W. A., Tomasella, J., and
Kruijt, B.: Evapotranspiration of deforested areas in central and southwestern
Amazonia, Theor. Appl. Climatol., 109, 205–220, <a href="http://dx.doi.org/10.1007/s00704-011-0570-1" target="_blank">doi:10.1007/s00704-011-0570-1</a>, 2012.
</mixed-citation></ref-html>
<ref-html id="bib1.bib101"><label>101</label><mixed-citation>
Zhang, Q., Manzoni, S., Katul, G., Porporato, A., and Yang, D.: The hysteretic
evapotranspiration-vapor pressure deficit relation, J. Geophys. Res.-Biogeo.,
119, 125–140, <a href="http://dx.doi.org/10.1002/2013JG002484" target="_blank">doi:10.1002/2013JG002484</a>, 2014.
</mixed-citation></ref-html>
<ref-html id="bib1.bib102"><label>102</label><mixed-citation>
Zuecco, G., Penna, D., Borga, M., and van Meerveld, H. J.: A versatile index
to characterize hysteresis between hydrological variables at the runoff
event timescale, Hydrol. Process., 30, 1449–1466, <a href="http://dx.doi.org/10.1002/hyp.10681" target="_blank">doi:10.1002/hyp.10681</a>, 2016.
</mixed-citation></ref-html>--></article>
